Schneider LC1F1250MD Contactor - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-Mail: kent@bestcontactor.com

Um Kontakt |

Schneider LC1F1250MD Contactor - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

Schütz/

Schneider LC1F1250MD Contactor

Definition of each part of LC1F1250MD: Segment Description LC Product category code, stands for Schneider Contactor product line 1 Standard single contactor (2 = reversing contactor) F Series code, stands for TeSys F Series (heavy-duty industrial contactor) 1250 Rated current specification: 1250A (actual 1260A under AC-1 @ 440V) M Coil voltage code: 220V (AC or DC distinguished by the ...

  • Produktdetails

Definition of each part of LC1F1250MD:

SegmentBeschreibung
LCProduct category code, steht für Schneider-Schütz product line
1Standard single contactor (2 = reversing contactor)
FSeriencode, stands for TeSys F Series (heavy-duty industrial contactor)
1250Rated current specification: 1250A (actual 1260A under AC-1 @ 440V)
MCoil voltage code: 220V (AC or DC distinguished by the following letter)
DCoil type code: DC coil (M7 = AC coil; MD = DC coil)

Kernunterschied:

LC1F1250MD is fitted with 220VDC coil, while LC1F1250M7 is 220VAC coil. Both share identical main circuit parameters; only the control circuit power supply type differs.

  1. Grundlegende technische Spezifikationen
KategorieParameter
Basic Characteristics• Product Series: TeSys F heavy-duty industrial contactor
• Polen: 3P (3 Stangen)
• Main Contacts: 3NEIN (3 Normalerweise geöffnet)
• Utilization Category: AC-1 (non-inductive / slightly inductive loads such as resistance furnaces)
• Montage: Standardmäßige 35-mm-DIN-Schiene / Bolzenmontage
Main Circuit Ratings• Rated Operational Voltage (Ue): ≤690 V Wechselstrom (50/60Hz) / ≤460V DC
• Rated Insulation Voltage (Ui): 1000V und
• Rated Operational Current (Dh): 1260A (AC-1, 440V, 40°C)
• Conventional Thermal Current (Ith): 1260A
• Short-time Withstand Current (Icw): 25Die / 1s @ 400V
• Contact Resistance: ≤0.12mΩ
Control Circuit Ratings• Coil Type: DC coil
• Rated Coil Voltage (Uc): 220VDC (compatible with 230VDC in practice)
• Coil Power Consumption: Pull-in 140W, Holding 24W
• Pull-in Time: ≤80ms
• Drop-out Time: ≤50ms
• Control Terminals: Screw clamp type
Mechanisch & Umweltfreundlich• Mechanical Life: 1,000,000 Operationen
• Electrical Life (AC-1): 100,000 Operationen
• Max Operating Frequency: 300 Zyklen/Stunde
• Operating Temperature: -5~+40°C (derating required +40~+60°C)
• Storage Temperature: -25~+60°C
• Protection Class: IP20 (nach der Installation)
• Abmessungen (B×H×T): 309×280×181mm
• Gewicht: Ca. 18kg
Zertifizierungen & Standards• Compliance: IEC 60947-4-1, IN 60947-4-1, GB 14048.4
• Approvals: CE, UL, CSA, CCC, UKCA
• Eco Certification: Green Premium (RoHS / REACh compliant)
  1. Zubehörliste

3.1 Standardzubehör

Contactor main unit LC1F1250MD ×1

Mounting fasteners (DIN rail clip / bolts) ×1

Operation Manual (electronic version) ×1

Coil surge suppressor (optional, separate order required)

3.2 Optionales Zubehör (Sold Separately)

ZubehörtypModellbeispielZweck
Auxiliary Contact BlockLAD9F01 / LAD9F10Add 1NO / 1NC auxiliary contacts for control circuit expansion
Mechanical Interlock BlockLA9FF976For reversing circuit (forward/reverse), prevents simultaneous closing of two contactors
Terminal Protection CoverLAD9V6Safety protection for main circuit terminals, electric shock prevention
Power Connection BusbarLAD9B1250High-current main circuit wiring, simplifies installation
Surge SuppressorLAD9R220Protect coil, suppress reverse EMF when DC coil is de-energized
Auxiliary Contact BaseLAD9FMount multiple auxiliary modules; expandable up to 6 auxiliary contacts maximum
  1. Wettbewerber & Cross-Brand Equivalent
MarkeModellNennstromSpulenspannungPolen / KontaktePreisniveauMain Advantages
SchneiderLC1F1250MD1250A220VDC3P / 3NEINHochHeavy-duty design, drawer-type coil, einfache Wartung
Schneider AlternativeLC1G1250MD1250A220VDC3P / 3NEINMittelhochTeSys Giga series, upgraded replacement for LC1F
Siemens3TF5544-0XM01250A220VDC3P / 3NEINHochFull series compatibility, seamless S7 PLC connection
ABBA1450-30-111250A220VDC3P / 3NEINHochModularer Aufbau, flexible auxiliary contact expansion
MitsubishiS-N12501250A220VDC3P / 3NEINMittelhochJapanese quality, cost-performance
EatonDILM1250(220VDC)1250A220VDC3P / 3NEINMitteKompakte Struktur, spart Platz im Schrank
  1. Auswahlrichtlinien & Replacement Solutions

5.1 Core Selection Rules

Lasttyp: AC-1 (resistance furnace, Heizung) → suitable for LC1F1250MD; AC-3 (Motor) → operate with derating or select dedicated AC-3 contactor

Control Supply: 220VDC → choose MD suffix; 220VAC → choose M7 suffix; refer to Schneider coil code table for other voltages

Installationsraum: Width 309mm, reserve sufficient cabinet space; for compact layout adopt LC1G series (smaller dimension)

Hilfskontakte: No built-in auxiliary contacts by default; order LAD9 series auxiliary modules separately

Wartungskomfort: Drawer-type coil structure; coil replacement without disconnecting main circuit wiring, ideal for frequent maintenance scenarios

5.2 Recommended Replacement Models

AnwendungsszenarioEmpfohlenes ModellGrund
Upgrade existing LC1FLC1G1250MDTeSys Giga upgraded series, höhere Leistung, more compact size, fully interchangeable
AC control power supplyLC1F1250M7Same main circuit parameters, 220VAC coil for AC control system
Motorsteuerung (AC-3)LC1F1250MD (derated to 800A)Heavy-duty design, usable for AC-3 after derating; alternatively use LC1F1400
Compact cabinet installationABB A1450-30-11Width 280mm, saves 29mm compared with LC1F1250MD
Budget limitedMitsubishi S-N1250Japanese brand, 15-20% lower price than European brands with reliable performance
DC supply & frequent operationLC1F1250MD + LAD9R220Surge suppressor protects coil and extends service life

5.3 Key Technical Advantages

  1. Heavy-duty Construction: 1260Ein Nennstrom, 25kA short-time withstand capability, suitable for large industrial loads
  2. Drawer-type Coil: Independent coil module; replaceable without removing main circuit wiring, maintenance efficiency improved by 50%
  3. Wide Voltage Compatibility: Main circuit up to 690V AC / 460In DC, adaptable to various industrial power systems
  4. Global Approvals: Full CE/UL/CSA/CCC/UKCA certification for worldwide project deployment
  5. Eco Compliance: Green Premium zertifiziert, meets RoHS/REACh environmental standards for sustainable application

Schneider LC1F1250MD is a TeSys F Series 3-pole 1250A heavy-duty industrial contactor. Its core strengths are drawer-type DC coil design and high short-circuit withstand capability, perfectly suited for AC-1 non-inductive / slightly inductive loads such as resistance furnaces and heating equipment.

Bei der Auswahl, focus on control supply type (220VDC), load category (AC-1 optimal), und Bauraum. For upgrade or replacement, prefer the new-generation TeSys Giga LC1G1250MD, or select LC1F1250M7 (220VAC) according to control power type.

Complete Model List of Schneider TeSys F (LC1F) Schütze (Letzte 2026 Version)

Classified by model naming rule, aktuelle Bewertung, coil code, full model list and selection guide. Covers all LC1F specifications including 3-pole / 4-Pole, Wechselstrom / DC coil, Standard / wide voltage versions for heavy-duty industrial control.

  1. LC1F Model Naming Rule

Format: LC1F[Current Rating][Coil Code][Special Function]

SegmentBeschreibungOptionen & Erläuterung
LCProduct CategoryContactor product line
1Contactor Type1 = Standard single contactor; 2 = Reversing contactor (forward/reverse)
FSeries CodeTeSys F Series heavy-duty type, 115A~2100A
[Current Rating]Nennstrom115/150/185/225/265/330/400/500/630/780/1000/1250/1400/1700/2100
[Coil Code]Spulenspannung & TypFirst letter = voltage level; last letter = coil type (7=AC, D=DC)
[Special Function]Optional FeatureS411 = Wide voltage coil (100-250V AC/DC); Blank = Standard version

Beispiel:

LC1F1250MD → 1250A, 220VDC-Spule

LC1F265M7 → 265A, 220VAC coil

  1. Coil Voltage Code Table (General for Whole Series)
Coil CodeStromspannungCoil TypeAnwendung
B6/B724VWechselstrom (50/60Hz)Safety control circuit, PLC output
C6/C736VWechselstromLow-voltage safety location
E6/E748VWechselstromIndustrial control, small equipment
F6/F7110VWechselstromNordamerika / Japan standard control system
M6/M7220VWechselstromChina / Asia standard general control
P6/P7230VWechselstromEuropean standard general control
Q6/Q7380VWechselstromIndustrial high-voltage control, large equipment
R6/R7400VWechselstromEuropean industrial 3-phase standard
S6/S7415VWechselstromCommonwealth national standard
U6/U7440VWechselstromNorth American industrial standard
BD24VGleichstromDC control, PLC output
CD36VGleichstromDC low-voltage control
ED48VGleichstromDC industrial control
FD110VGleichstromDC control system
MD220VGleichstromGeneral DC control (most widely used)
PD230VGleichstromEuropean DC standard
QD380VGleichstromDC high-voltage control
S411100-250VAC/DC UniversalWide voltage for global projects
  1. LC1F Full Current Ratings & Base Models

3P Standard Type (3P/3NO) for AC-1 resistive load and AC-3 motor load:

Base ModelRated Current AC-1@440V,40°CAC-3 Current@400VMatched Motor Power@400V AC-3Breite (mm)
LC1F115115A115A55KW100
LC1F150150A150A75KW100
LC1F185185A185A90KW125
LC1F225225A225A110KW140
LC1F265265A265A132KW160
LC1F330330A330A160KW180
LC1F400400A400A200KW200
LC1F500500A500A250KW220
LC1F630630A630A315KW250
LC1F780780A780A375KW280
LC1F10001000A1000A450KW300
LC1F12501260A1250A560KW309
LC1F14001400A1400A630KW320
LC1F17001700A1700A750KW340
LC1F21002100A2100A900KW360

4P Extended Type (4P/4NO): Model suffix with 4 (LC1F1154 ~ LC1F21004). Rated current same as 3P version, suitable for 4-wire systems.

  1. Complete LC1F Model List by Current

4.1 115A~265A Medium Power

Vollständiges ModellAktuellCoil SpecPolen
LC1F115B6115A24V und3P
LC1F115B7115A24V und3P
LC1F115BD115A24In DC3P
LC1F115M7115A220V und3P
LC1F115MD115A220In DC3P
LC1F150M7150A220V und3P
LC1F150MD150A220In DC3P
LC1F185M7185A220V und3P
LC1F185MD185A220In DC3P
LC1F225M7225A220V und3P
LC1F225MD225A220In DC3P
LC1F265M7265A220V und3P
LC1F265MD265A220In DC3P
LC1F265S411265A100-250V AC/DC3P

4.2 330A~780A High Power

Vollständiges ModellAktuellCoil SpecPolen
LC1F330M7330A220V und3P
LC1F330MD330A220In DC3P
LC1F400M7400A220V und3P
LC1F400MD400A220In DC3P
LC1F500M7500A220V und3P
LC1F500MD500A220In DC3P
LC1F630M7630A220V und3P
LC1F630MD630A220In DC3P
LC1F780M7780A220V und3P
LC1F780MD780A220In DC3P

4.3 1000A~2100A Super High Power

Vollständiges ModellAktuellCoil SpecPolenBemerkungen
LC1F1000M71000A220V und3P
LC1F1000MD1000A220In DC3P
LC1F1250M71250A220V und3PPopular model
LC1F1250MD1250A220In DC3PPopular model
LC1F1400M71400A220V und3PDrawer coil type
LC1F1400MD1400A220In DC3PDrawer coil type
LC1F1700M71700A220V und3PDrawer coil type
LC1F1700MD1700A220In DC3PDrawer coil type
LC1F2100M72100A220V und3PDrawer coil type
LC1F2100MD2100A220In DC3PDrawer coil type
LC1F2100S411P72100A100-250V und3PWide voltage version

4.4 4-Pole Series (Suffix with 4)

Vollständiges ModellAktuellCoil SpecPolenAnwendung
LC1F1154M7115A220V und4P4-wire system
LC1F1854MD185A220In DC4P3-phase 4-wire
LC1F2654M7265A220V und4PLoad with neutral line
LC1F4004MD400A220In DC4P4-pole protection system
  1. Reversing Contactor Models (LC2F Series)

LC2F = Reversing type for motor forward/reverse control with mechanical interlock to prevent simultaneous closing:

Vollständiges ModellAktuellCoil SpecPolenInterlock Type
LC2F115M7115A220V und3P+3PMechanical interlock
LC2F185MD185A220In DC3P+3PMechanical interlock
LC2F265M7265A220V und3P+3PMechanical interlock
LC2F400MD400A220In DC3P+3PMechanical interlock
  1. Model Replacement & Upgrade Guide
  2. LC1F Upgrade: Replace LC1F with LC1G (TeSys Giga); more compact size, 30% performance improvement, fully interchangeable mounting and wiring.
  3. Coil Replacement: Same current rating different coils are interchangeable (z.B. LC1F1250M7 ↔ LC1F1250MD, only coil module replaced).
  4. Load Application:

AC-1 resistive load: Verwenden 100% Nennstrom

AC-3 motor load: Verwenden 100% Nennstrom (LC1F designed for heavy duty)

AC-4 frequent starting: Derate by 30%

  1. Wide Voltage Requirement: Select S411 suffix model, compatible with 100-250V AC/DC global control power supply.
  2. Quick Selection Chart
AnwendungsszenarioEmpfohlenes ModellKey Reason
55kW motor control @400VLC1F115M7Matched power, kostengünstig
110kW motor control @400VLC1F225M7Heavy-duty design, stable operation
560kW resistance furnaceLC1F1250MD1260Ein Nennstrom, DC control
Global multi-voltage projectLC1F265S411Wide voltage adaption, no coil replacement needed
DC control systemLC1FxxxMDDC coil, starke Anti-Interferenz
4-wire distribution systemLC1Fxxx4M74-pole design for neutral circuit
Frequent maintenance siteLC1F1400MD+Drawer-type coil structure, einfache Wartung

Vorher:

Hinterlassen Sie eine Antwort

Eine Nachricht hinterlassen