Schneider LC1N2501 AC Contactor

LC1N2501 is a 3-pole 25A AC Contactor of Schneider Electric EasyPact D3N Series. It is standard configured with 3 normally open main contacts + 1 normally closed auxiliary contact. It is suitable for 11kW / 380V motor control under AC-3 duty, widely used in industrial automation and motor control circuits, featuring high reliability and flexible ...

  • Produktdetails

LC1N2501 is a 3-pole 25A AC Contactor of Schneider Electric EasyPact D3N Series. It is standard configured with 3 normally open main contacts + 1 normally closed auxiliary contact. It is suitable for 11kW / 380V motor control under AC-3 duty, widely used in industrial automation and motor control circuits, featuring high reliability and flexible installation.

  1. Modellsegmentdefinition
SegmentBedeutungDetaillierte Beschreibung
LC1ProduktseriencodeLC = TeSys series contactor; 1 = Standard AC contactor
NSub-series identifierN = EasyPact D3N Series (replaces the original LC1E Series); economy design for general industrial applications
25BemessungsbetriebsstromMain contact rated current 25A (AC-3 / 440V, 60°C)
1Hilfskontaktkonfiguration0 = 0 Normalerweise geöffnet; 1 = 1 Normalerweise geschlossen, i.e. 1 NC auxiliary contact
[Suffix]Coil voltage codez.B. M5=220V AC 50Hz, B5=24V DC, C5=36V AC, F5=110V AC, Q5=380V AC

Complete Model Examples:

LC1N2501M5N (220V AC coil, 50Hz)、LC1N2501B5N (24V DC coil)

  1. Kernspezifikationsparameter
ParameterkategorieTechnical IndexBemerkungen
Basic Characteristics
Produkttyp3-Pole AC ContactorEasyPact D3N Series, replacement for LC1E2501
MarkeSchneider ElectricBenchmark brand in industrial control
Main Contact Configuration3NEIN (3 Normalerweise geöffnet)Standard AC-3 motor control configuration
Hilfskontaktkonfiguration1NC (1 Normalerweise geschlossen)Expandable up to maximum 4 Hilfskontakte (2NO+2NC)
Nennbetriebsstrom25A (AC-3, 440V, 60°C)Corresponding motor power: 11kW@380V, 15kW@220V
Nennbetriebsspannung≤690 V Wechselstrom (50/60Hz)Maximum working voltage of main circuit
Elektrische Leistung
Rated Insulation Voltage Ui690VKonform mit IEC 60947-4-1
Rated Impulse Withstand Voltage Uimp6kVStrong surge withstand capability
Rated Operating Frequency1200 Zyklen/Stunde (AC-3)Suitable for frequent start-stop operation
Mechanisches Leben≥10 Millionen ZyklenHigh durability design
Elektrisches Leben≥1 million cycles (AC-3, Nennstrom)Meets long-term service requirements
Spulensteuerspannung24V~380V AC/DC optionalStandard: 220V und (M5)
SpulenstromverbrauchPick-up: ca. 100VA; Holding: ca. 10VAGeringer Stromverbrauch, energy-saving & high efficiency
Physikalische Dimensionen
Montagemethode35mm DIN rail or screw mountingTwo mounting options for different cabinet layouts
GesamtdimensionW45mm × H80mm × D85mmKompaktes Design, spart Platz im Schrank
GewichtCa. 170GLightweight for easy installation & handling
TerminaltypHauptstromkreis: Screw type; Steuerkreis: Spring typeMain circuit compatible with 1.5-10mm² wire, tightening torque 1.85N·m
Umgebungsbedingungen
Betriebstemperatur-25°C ~ +60°CWide temperature range, adapts to harsh industrial environments
Lagertemperatur-40°C ~ +85°CWithstands extreme temperature storage
Schutz vor EindringenIP20Protects against finger access and solid foreign objects, suitable for cabinet installation
Humidity Resistance5%~95% RH (nicht kondensierend)Adapts to humid environments
Zertifizierungen & Standards
Main StandardsIEC 60947-4-1, GB14048.4Compliant with international and national standards
Certification MarksCCC, CE, UL, CSAGlobal market access qualifications
  1. Zubehörliste & Mounting Parts
Part ModelNameFunktionAnwendungsszenario
LRN07N-LRN35NThermisches ÜberlastrelaisDirect plug-in with contactor, provides motor overload protectionMotor control circuit requiring overload protection
LANN01N-LANN22NAuxiliary Contact BlockExpand auxiliary contact quantity (max. 2NO+2NC)Complex control circuits requiring more auxiliary contacts
LA9D09978CMechanical Interlock AccessoryInterlocks two contactors to prevent phase-to-phase short circuitReversible motor control (Forward/Reverse)
LA9D0902Mechanisch + Electrical InterlockDual protection of mechanical and electrical interlockReversible control circuits with high safety requirements
Overvoltage Suppression ModuleRC / Varistor Surge SuppressorAbsorbs back EMF generated during coil de-energizationProtects electronic components in control circuit
Mounting Rail35mm Standard DIN RailFixes contactor in positionStandardized installation inside control cabinet
Terminal Protection CoverInsulating Protective ShieldPrevents accidental electric shock and improves safetyProtection for exposed terminals, complies with safety regulations
InstallationshandbuchOperation GuidelineProvides detailed installation procedures and wiring diagramsOn-site installation guidance to ensure correct wiring
  1. Wettbewerber & Cross-Brand Equivalent
MarkeErsatzmodellSimilar FeaturesUnterschiede
Schneider Internal ReplacementLC1D25013-pole 25A, 1NC auxiliary, AC-3 11kWTeSys D series, better performance, higher price
ABBA16-30-013-pole 25A, 1NC auxiliary, 11kW@400VSimilar dimension, slightly higher coil power consumption, comparable price
Siemens3RT2026-1BB403-pole 25A, 1NC auxiliary, 11kW@400VMechanisches Leben 10 million cycles, elektrische Lebensdauer 2 million cycles, slightly higher price
MitsubishiS-N253-pole 25A, 1NC auxiliary, 11kW@400VSmaller size, compact mounting, moderater Preis
ChintCJX2-25013-pole 25A, 1NC auxiliary, 11kW@380VInländische Alternative, hohe Kostenleistung, ähnliche Leistung
LeckerCJX2S-25013-pole 25A, 1NC auxiliary, 11kW@380VInländische Alternative, lower price, suitable for budget-limited projects
  1. Auswahlrichtlinien & Replacement Solutions

5.1 Wichtige Auswahlparameter

ParameterWichtige AuswahlpunkteRecommended Specification
Rated Current MatchingContactor rated current ≥ motor rated current (AC-3-Dienst)25A contactor suitable for ≤11kW/380V motors
HilfskontaktkonfigurationSelect NO/NC quantity according to control circuit demandStandard 01(1NC); Normally Open select 10(1NEIN); More contacts select 22
Coil Voltage SelectionConsistent with control circuit voltageIndustrial common: 220V und(M5); Safety voltage: 24In DC(B5)
MontagemethodeDetermined by control cabinet layoutDIN-Schienenmontage (Standard); Screw mounting for limited space
Protection RequirementNeed for overload protection and interlock functionMotor control must match LRN thermal relay; Reversible control requires interlock accessory
BetriebsfrequenzHigh-frequency start-stop occasion requires high-cycle modelStandard 1200 Zyklen/Stunde; Ultra-high frequency choose LC1D series

5.2 Ersatzempfehlungen

Current rating mismatch:

Motor power ≤7.5kW: Select LC1N1801 (18A)

Motor power 15kW: Select LC1N3201 (32A)

Insufficient auxiliary contacts:

Add LANN series auxiliary contact block, expandable up to 2NO+2NC maximum

Different control voltage:

24V DC control: LC1N2501B5N

380V AC control: LC1N2501Q5N

Higher performance required:

Choose LC1D2501 (TeSys D series), mechanical life 10 million cycles, elektrische Lebensdauer 2 million cycles, stronger vibration resistance

Budget limited:

Adopt domestic alternatives such as Chint CJX2-2501, Delixi CJX2S-2501; similar performance with price reduced by about 30-50%

5.3 Application Precautions

  1. Confirm coil voltage matches control circuit before installation to avoid coil burnout.
  2. Fasten main circuit wiring with recommended torque 1.85N·m to prevent overheating and poor contact.
  3. When directly plugging with LRN series thermal relay, ensure complete latch locking to prevent loosening by vibration.
  4. Reversible control circuit must be equipped with LA9D09978C mechanical interlock to prevent phase-to-phase short circuit.
  5. It is recommended to parallel surge suppressor at both ends of the coil to protect PLC/relay contacts in control circuit.
  6. When ambient temperature exceeds 40°C, derate rated current (10% reduction per additional 10°C rise).
  7. Regularly check contact ablation; replace contactor when main contact wear exceeds 1mm.
  8. Typische Anwendungsszenarien

Direct starting control of three-phase asynchronous motor (≤11kW/380V)

Start-stop control for fans, water pumps and general machinery

Electrical control for compressors, conveyors and industrial equipment

Compressor control for air conditioning and refrigeration systems

Lighting and ventilation system control in building electrical systems

Motor control circuits for automated production lines

Auxiliary motor control for machine tool equipment

Output switching control for photovoltaic inverters and UPS power supplies

Complete Model List of Schneider LC1N Series (EasyPact D3N) Schütze

LC1N Series is Schneider Electric EasyPact D3N 3-pole AC contactor, replacing the original LC1E Series. It is designed for AC-3 motor control, covering current ratings from 6A to 95A, with multiple auxiliary contact configurations and coil voltage options. Supports DIN rail or screw mounting with IP20 ingress protection.

  1. Modellcodierungsregeln
SegmentBedeutungOptional ValueBeschreibung
LC1ProduktserieLC1Schneider TeSys contactor series
NSub-seriesNEasyPact D3N Series (Wirtschaftstyp)
XXNennstrom06/09/12/18/25/

32/38/40/50/65

/80/95

Einheit: A (AC-3/440V, 60°C)
YYHilfskontakt00/01/10/22/1100=No auxiliary; 01=1NC; 10=1NO; 22=2NO+2NC; 11=1NO+1NC
ZCoil Voltage CodeB/E/F/M/Q/B=24V; E=48V; F=110V; M=220V; Q=380V
5月7日Frequenz5月7日5=50Hz; 7=50/60Hz universal
N/COriginN/CN=Standard; C=Made in China

Complete Model Example:

LC1N2501M5N (25A, 1NC, 220V AC 50Hz)

  1. Full Current Rating & Basic Model Matrix

2.1 Standard Auxiliary Configuration (01/10)

NennstromMatched Motor Power(380V)1NC(01)1NEIN(10)Bemerkungen
6A2.2kWLC1N0601LC1N0610Minimum current size
9A3kWLC1N0901LC1N0910
12A4kWLC1N1201LC1N1210
18A7.5kWLC1N1801LC1N1810
25A11kWLC1N2501LC1N2510Most commonly used
32A15kWLC1N3201LC1N3210
38A18.5kWLC1N3801LC1N3810
40A22kWLC1N4001LC1N4010
50A25kWLC1N5001LC1N5010
65A30kWLC1N6501LC1N6510
80A37kWLC1N8001LC1N8010
95A45kWLC1N9501LC1N9510Maximum current size

2.2 Special Auxiliary Configuration (11/22/00)

Nennstrom1NO+1NC(11)2NO+2NC(22)No Auxiliary(00)Anwendungsszenario
6A~38ALC1NXX11LC1NXX22LC1NXX00Complex control circuit requiring multi-contacts
40A~95ALC1NXX11LC1NXX22LC1NXX00High-power motor control requiring contact expansion
  1. Complete Coil Voltage Options

3.1 AC Coil Voltage Code

SpannungscodeSpulenspannungFrequency CodeComplete Model ExampleAnwendungsszenario
B24V und5(50Hz)/7(50/60Hz)LC1N2501B5N / LC1N2501B7NSafety voltage control, PLC output
C36V und5-7LC1N2501C5N / LC1N2501C7NSafety circuit, machine tool control
E48V und5-7LC1N2501E5N / LC1N2501E7NIndustrial control, special equipment
F110V und5-7LC1N2501F5N / LC1N2501F7NNorth American standard, partial equipment
M220V und5-7LC1N2501M5N / LC1N2501M7NChinese industrial standard, most widely used
P230V und5-7LC1N2501P5N / LC1N2501P7NEuropäischer Standard, compatible with 220V
Q380V und5-7LC1N2501Q5N / LC1N2501Q7NHigh-voltage control circuit, direct 380V supply
R400V und5-7LC1N2501R5N / LC1N2501R7NEuropean industrial standard
S415V und5-7LC1N2501S5N / LC1N2501S7NSoutheast Asian standard

3.2 DC Coil Voltage Code

SpannungscodeSpulenspannungComplete Model ExampleAnwendungsszenario
B24In DCLC1N2501B5NSafety control, PLC digital output
L48In DCLC1N2501L5NIndustrial DC system
K110In DCLC1N2501K5NSpecial DC equipment
N220In DCLC1N2501N5NHigh-voltage DC control
  1. Common Complete Model Combinations
Komplettes ModellAktuellHilfskontaktSpulenspannungMatched Motor PowerTypische Anwendung
LC1N2501M5N25A1NC220V AC 50Hz11kWWasserpumpe & Lüftersteuerung
LC1N3210B7N32A1NEIN24V AC 50/60Hz15kWPLC control circuit
LC1N1801F5N18A1NC110V AC 50Hz7.5kWAusrüstung exportieren
LC1N5011M7N50A1NO+1NC220V AC 50/60Hz25kWCompressor control
LC1N6522Q5N65A2NO+2NC380V AC 50Hz30kWLarge fan
LC1N0900B5N9ANo auxiliary24V AC 50Hz3kWSimple control circuit
LC1N9511M7N95A1NO+1NC220V AC 50/60Hz45kWHigh-power motor
  1. Selection Reference Table

5.1 Current Rating vs Motor Power (AC-3/380V)

NennstromMotorleistung(kW)Wire Size(mm)Matching Thermal Relay
6A2.21.5LRN06N
9A31.5LRN06N
12A41.5LRN07N
18A7.52.5LRN10N
25A114LRN14N
32A156LRN21N
38A18.56LRN21N
40A2210LRN25N
50A2510LRN32N
65A3016LRN35N
80A3725LRN35N
95A4535LRN40N

5.2 Auxiliary Contact Expansion Options

Base ModelExpandable AccessoryExpanded Contact ConfigurationAnwendungsszenario
LC1NXX01/10LANN01N(1NEIN)2NEIN / 2NCAdd more control circuit contacts
LC1NXX01/10LANN22N(2NO+2NC)3NO+2NC / 2NO+3NCComplex control logic
LC1NXX00LANN01N+LANN02N1NO+1NCExpand from no auxiliary to standard configuration
  1. Quick Model Selection Guide
  2. Confirm current rating: Select according to motor power (Under AC-3 duty, contactor rated current ≥ motor rated current).
  3. Select auxiliary contacts: 01(1NC) for stop control; 10(1NEIN) for self-locking; 11(1NO+1NC) for reversible control.
  4. Match coil voltage: Consistent with control circuit voltage (220V AC common; 24V DC for safety occasions).
  5. Frequency selection: Domestic standard 50Hz(Code 5); Export equipment use universal 50/60Hz(Code 7).
  6. Accessory configuration: Motor control must match LRN thermal relay; Reversible control requires LA9D mechanical interlock.
  7. Common Model Replacement Table
OriginalmodellErsatzmodellReplacement Reason
LC1E2501LC1N2501EasyPact D3N replaces original EasyPact E Series
LC1D2501LC1N2501Economy model replaces high-performance model, cost reduced by approx. 20%
CJX2-2501LC1N2501Import replaced by domestic, performance improved with similar price

Vorher:

Hinterlassen Sie eine Antwort

Eine Nachricht hinterlassen