ABB 3BSE008508R1 DI810 - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

ABB 3BSE008508R1 DI810 - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

eléctrico/

ABB 3BSE008508R1 DI810

ABB 3BSE008508R1 DI810 Digital Input Module (S800 I/O Series) Part of Model Description 3BSE Product prefix for ABB S800 I/O system modules 8508 Product code for DI810 digital input module R1 Hardware revision number (Revision 1) Core Specifications Parameter Category Details Product Name ABB DI810 Digital Input Module System ABB S800 I/O Distributed Process I/O ...

  • Detalles del producto

ABB 3BSE008508R1 DI810

Digital Input Module (S800 I/O Series)

Part of ModelDescripción
3BSEProduct prefix for ABB S800 I/O system modules
8508Product code for DI810 digital input module
R1Hardware revision number (Revision 1)
  1. Especificaciones principales
Categoría de parámetroDetalles
Product NameABB DI810 Digital Input Module
SystemABB S800 I/O Distributed Process I/O System
Input Channels16 digital input channels, divided into two groups of 8 channels each
Voltaje de entrada24En DC (wide range: 18V–30V DC)
Corriente de entrada6mA per channel, máximo. 150mA total
IsolationGroup isolation (two groups × 8 canales), isolation voltage 500V AC
Tiempo de respuestaStandard mode: ≤1ms; High-speed mode: ≤0.1ms
DiagnosticsChannel status indication, power supply monitoring, wire break detection
Termination UnitTo be used with TU810/TU812/TU814/TU818/TU830 etc.
Clasificación de protecciónIP20 (for indoor cabinet mounting)
Fuente de alimentación24En DC, power consumption approx. 2W.
Dimensiones102mm × 119mm × 45mm (W × H × D)
PesoAprox.. 0.2kilos (exact 0.24kg)
Temperatura de funcionamiento-20°C a +60°C
Temperatura de almacenamiento-40°C to +85°C
Humedad5%–95% RH (non-condensing)
MontajeMontaje en carril DIN estándar, compatible with S800 I/O system racks
  1. Recommended Operating Environment
  2. Industrial Applications: Process automation control systems, petrochemical, power and energy, metallurgy and mining, paper and printing, food and beverage industries
  3. Network Environment: Supports communication with ABB AC 800M controllers, Freelance controllers, and other brand PLCs
  4. Mounting Location: Installed in control cabinets, close to sensors and actuators to reduce wiring costs
  5. Tipos de señal: Suitable for dry contacts, wet contacts, NO/NC switch signals, and digital output signals from sensors
  6. Cross-Brand Model Comparison & Alternativas
MarcaModeloProduct NameParámetros principalesDifferences from DI810
siemens6ES7 131-4BD02-0AB0ET 200S Digital Input Module16 canales, 24En DC, group isolationSystem compatibility (PROFIBUS-DP), differences in diagnostic functions
Rockwell1734-IB8POINT I/O 8-Ch Digital Input Module8 canales, 24En DC, individual isolationHalf the number of channels; expansion module required
SchneiderBMXDDI1602Modicon M340 Digital Input Module16 canales, 24En DC, group isolationCommunication protocol (Modbus TCP), different module dimensions
mitsubishiQX40Q-Series Digital Input Module16 canales, 24En DC, no group isolationDifferent isolation design, different system architecture
OmrónCJ1W-ID211CJ-Series Digital Input Module16 canales, 24En DC, group isolationCommunication interface (DispositivoNet), differences in diagnostic capabilities
  1. Official Ordering Information
Order DetailsDescripción
Official Order Number3BSE008508R1
Packing ListSingle module including installation manual and product certification documents
Warranty12 meses (ABB original factory)
Compatible ControllersABB AC 800M, Freelance, S900, etc..
Modelo de reemplazo3BSE008508R0001 (latest version)
  1. Complete Model List for DI810 Series
ModeloDescripción
3BSE008508R1Standard version, 16-channel 24V DC digital input, group isolation
3BSE008508R0001Latest hardware revision with improved diagnostics
3BSE008508R2Enhanced version supporting high-speed response (≤0.1ms)
3BSE008508R3Wide-temperature version, operating range -40°C to +70°C
  1. Engineering Implementation Notes
  2. Notas de instalación

Module to be mounted on DIN rail and used with termination units (p.ej., TU810)

Maintain at least 5mm clearance between modules for heat dissipation; avoid high-temperature environments

Route input signal cables separately from power cables to reduce electromagnetic interference

  1. Estándares de cableado

Each group of 8 channels shares a common terminal (COM); observe group assignments during wiring

Shielded twisted-pair cable recommended for input signals, with shield grounded at one end

Wire break detection must be enabled in system configuration for monitoring critical signals

  1. System Configuration

Configure module parameters in ABB Control Builder software

Adjustable settings: channel response time, filter time, umbrales de alarma, etc..

Supports online diagnostics and hot-swapping (system-dependent)

  1. Consejos de mantenimiento

Regularly check module status LEDs (fuerza, channel status)

Avoid hot-swapping to prevent electronic component damage

Clean module with a dry soft cloth only; do not use chemical cleaners

ABB 3BSE008508R1 DI810 es un alto rendimiento, Módulo de entrada digital de 16 canales de alta confiabilidad adecuado para varios sistemas de control de automatización industrial. Su diseño de grupo aislado, amplio rango de voltaje de entrada, y sus ricas funciones de diagnóstico lo convierten en una opción ideal para el control de procesos.. Para reemplazo entre marcas, attention must be paid to system compatibility, protocolos de comunicacion, and isolation characteristics.

Complete Model List & Cross-Brand Comparison for ABB S800 I/O Digital Input Modules

Key Overview

System: ABB S800 I/O Distributed Process I/O System, compatible with AC 800M, Freelance, etc..

Classification: By voltage type (24En DC / 48En DC / 120V y), channel count (8/16/32 canales), isolation (group isolation / individual isolation)

Características clave: Intercambiable en caliente, channel diagnostics, wide-temperature operation, DIN rail mountable

  1. Complete Model List of ABB S800 I/O Digital Input Modules

1.1 24V DC Series (Mainstream General-Purpose)

ModeloNúmero de pedido.CanalesInput TypeIsolationTiempo de respuestaCaracterísticas claveAplicaciones
DI8103BSE008508R116Sink/Source2 groups × 8 canales (500V y)Standard ≤1ms; High-speed ≤0.1msClassic general-purpose, group isolation, rich diagnosticsProcess control, automotive manufacturing, automation lines
DI8113BSE008516R116Sink/Source2 groups × 8 canales (500V y)Standard ≤1ms; High-speed ≤0.1ms48V DC compatible, high-density, flexible sensor compatibilityHigh-volume signal acquisition, 48Sistemas V CC
DI8143BSE008519R116Fuente2 groups × 8 canales (500V y)Standard ≤1msSource input, designed for PNP sensorsSensor signal acquisition, equipo de automatización
DI8183BSE008522R132Sink2 groups × 16 canales (500V y)Standard ≤1ms32-channel high-density, ahorra espacio en el gabineteLarge-scale signal monitoring, water treatment systems
DI8203BSE008512R18120V yIndividual channels (250V y)Standard ≤10msAC input, individual isolation, strong anti-interferenceEquipos industriales, motor control, high-voltage signals
DI8213BSE008513R1848En DCIndividual channels (500V y)Standard ≤1msHigh-voltage DC, individual isolation, alta confiabilidadRail transit, sistemas de energía
DI8253BSE008514R11624En DCIndividual channels (500V y)Standard ≤1msIndividual channel isolation, precise diagnosticsSafety systems, critical signal monitoring

1.2 Special Function Series (High-End / Seguridad)

ModeloNúmero de pedido.Características claveAplicaciones
DI8303BSE012291R1SIL3 certified, channel-level redundancy, time stampingSafety Instrumented Systems (SIS), process safety control
DI8313BSE012292R1High-speed response (≤0.05ms), HART compatibleHigh-speed motion control, precision process control
DI8403BSE013234R1Intrinsically safe, for hazardous areas (Ex ia)Petroquímico, minería, flammable and explosive environments

1.3 Model Naming Convention

ParteSignificadoEjemplo (DI810)
DEDigital Input ModuleDI = Digital Input
8S800 I/O Series Identifier8 = S800 Series
10Código de producto (24En DC, 16 canales, group isolation)10 = Basic general-purpose type
R1Hardware revision numberR1 = Initial version
  1. Cross-Brand Model Comparison (By Application Match)

2.1 Siemens Equivalent Models

ABB ModelParámetros principalesSiemens EquivalentSystemDiferencias claveReplacement Advice
DI810 (16DE, 24En DC, group isolation)16 canales, 24En DC, group isolation, 500V AC insulation6ES7131-4BD02-0AB0ET200SCommunication protocol (PROFIBUS vs PROFINET), diagnostic differencesFuncionalmente equivalente; configuration software adjustment required
DI818 (32DE, 24En DC, group isolation)32 canales, 24En DC, group isolation6ES7131-4BF00-0AA0ET200SPDouble channel count, different module sizeTwo ET200SP modules required
DI820 (8DE, 120V y, individual isolation)8 canales, 120V y, individual isolation6ES7131-4FF00-0AB0ET200SRango de voltaje, isolation methodSiemens AC input module required for 120V AC
DI830 (SIL3 certified)Safety-rated, channel redundancy6ES7521-1BH10-0AA0S7-1500FSafety certification level, system architectureMust meet SIL3 certification requirements

2.2 Rockwell Equivalent Models

ABB ModelParámetros principalesRockwell EquivalentSystemDiferencias claveReplacement Advice
DI810 (16DE, 24En DC)16 canales, 24En DC, sink/source compatible1734-IB8 ×2POINT I/OHalf channel count; two modules neededExtra module required, slightly higher cost
DI818 (32DE, 24En DC)32 canales, 24En DC, high-density1756-IB16 ×2ControlLogixCommunication interface (ControlNet vs PROFIBUS)Two modules, flexible expansion
DI820 (8DE, 120V y)8 canales, 120V y1794-IA8Flex I/OVoltage type, terminal styleFunctionally matched; wiring adjustment required

2.3 Schneider Equivalent Models

ABB ModelParámetros principalesSchneider EquivalentSystemDiferencias claveReplacement Advice
DI810 (16DE, 24En DC)16 canales, 24En DC, group isolationBMXDDI1602Modicon M340Communication protocol (Modbus TCP vs PROFIBUS)Funcionalmente equivalente; different software platform
DI818 (32DE, 24En DC)32 canales, 24En DCBMXDDI3202KModicon M580Matching channel count, module dimensionsReemplazo directo; reconfiguration required
DI820 (8DE, 120V y)8 canales, 120V yABE701111Modicon PremiumRango de voltaje, isolation ratingSchneider AC input module required

2.4 Mitsubishi Equivalent Models

ABB ModelParámetros principalesMitsubishi EquivalentSystemDiferencias claveReplacement Advice
DI810 (16DE, 24En DC)16 canales, 24En DC, group isolationQX40Q SeriesCommunication interface (CC-Link vs PROFIBUS), diagnosticsFunctionally matched; bus module replacement required
DI818 (32DE, 24En DC)32 canales, 24En DCQX80Q SeriesChannel count, system architectureTwo QX80 modules required
DI820 (8DE, 120V y)8 canales, 120V yAY11A SeriesVoltage type, module typeMitsubishi AC input module required

2.5 Omron Equivalent Models

ABB ModelParámetros principalesOmron EquivalentSystemDiferencias claveReplacement Advice
DI810 (16DE, 24En DC)16 canales, 24En DC, group isolationCJ1W-ID211CJ SeriesCommunication interface (DeviceNet vs PROFIBUS), terminal styleFuncionalmente equivalente; system configuration adjustment required
DI818 (32DE, 24En DC)32 canales, 24En DCCS1W-ID211CS SeriesChannel count, system performanceTwo modules required, higher cost
DI820 (8DE, 120V y)8 canales, 120V yC200H-ID212C200HRango de voltaje, isolation methodOmron AC input module required
  1. Key Considerations for Replacement Selection

3.1 Core Matching Criteria

  1. Voltaje & Canales: Ensure input voltage and channel count match exactly to avoid signal damage or loss
  2. Isolation Method: Group isolation (ABB standard) vs. individual isolation (some Siemens/Mitsubishi models) affects interference immunity and safety rating
  3. Protocolo de comunicación: PROFINET / PROFIBUS vs. Modbus / CC-Link; must match controller bus
  4. Termination Units: ABB requires TU810/TU812 etc.; cross-brand replacement needs redesigned terminal layout
  5. Diagnostics: ABB channel-level diagnostics vs. module-level diagnostics on other brands, affecting maintenance efficiency

3.2 Engineering Implementation Guidelines

PhaseKey Standards
InstalaciónMust mount on DIN rail; keep ≥30cm from heat-generating devices (inversores); 5mm clearance for cooling
AlambradoUse shielded twisted-pair cable, shield grounded at one end; group common (COM) wiring to prevent short circuits
ConfiguraciónCross-brand replacement requires full project redevelopment; software incompatible (WinCC vs CX-Programmer vs Unity Pro)
MantenimientoRegularly check LED status (power/channel/fault); no hot-swapping for non-hot-swap modules

3.3 Priority Recommended Replacement Solutions

SolicitudPreferred ABB ModelCross-Brand AlternativeReason
Functional EquivalenceDI810 / DI814Siemens 6ES7131-4BD02-0AB0Exact match in channels, Voltaje, and isolation
Optimización de costosDI818 (32 canales)Rockwell 1756-IB16 ×2High density, rentable
Safety SystemsDI830Siemens 6ES7521-1BH10-0AA0SIL3 certified, channel redundancy
Hazardous AreasDI840 (intrinsically safe)Pepperl+Fuchs KFD2-STC4-EX1 + standard DI moduleIntrinsically safe isolation, explosion-proof compliance
  1. & Spare Parts List
  2. Full Range Coverage: ABB S800 I/O digital input modules cover 8–32 channels and 24V DC to 120V AC for all industrial scenarios
  3. Compatibilidad entre marcas: Equivalent models available from major brands; prioritize matching channels + Voltaje + isolation, then protocol and diagnostics
  4. Spare Parts Recommendation: Stock DI810 (propósito general), DI818 (high-density), DI820 (AC input) to cover over 80% of applications

Anterior: