ABB M1M-2TAZ664052R0007 - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

ABB M1M-2TAZ664052R0007 - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

medidor de electricidad/

ABB M1M-2TAZ664052R0007

M1M: ABB M1M Series Motor Protection and Management Unit (Motor Protection Controller) 2TAZ664052R0007: Corresponding ABB original order number / material code Product Type Low-voltage three-phase motor integrated protection relay, used for motor protection, monitoring and basic control. Core Functions Overload, locked-rotor, and underload protection Phase sequence, pérdida de fase, and phase imbalance protection Earth fault / ...

  • Detalles del producto

M1M: ABB M1M Series Motor Protection and Management Unit (Motor Protection Controller)

2TAZ664052R0007: Corresponding ABB original order number / material code

  1. Tipo de producto

Low-voltage three-phase motor integrated protection relay, used for motor protection, monitoring and basic control.

  1. Funciones centrales

Sobrecarga, locked-rotor, and underload protection

Phase sequence, pérdida de fase, and phase imbalance protection

Earth fault / earth leakage protection

Motor operating status monitoring and fault output

  1. Same Series & Modelos alternativos

Same series: Full ABB M1M series (M1M 01/02/03 and other current ratings)

Upgraded alternatives: ABB M102 / M2M series (functionally compatible with enhanced performance)

Cross-brand alternatives: Siemens 3RB series, Schneider EOCR series motor protection relays

  1. Aplicaciones típicas

Protection for three-phase asynchronous motors such as industrial fans, bombas de agua, transportadores, y compresores, as well as automated production lines and factory low-voltage power distribution systems.

ABB M1M Series Digital Multifunction Power Meters

  1. Significado del modelo & Posicionamiento del producto

Desglose del modelo

M1M: ABB System pro M Series Digital Multifunction Power Meters (not motor protectors; please distinguish carefully)

Suffix numbers: Product function level (10/12/15/20/30); higher numbers indicate richer functions

Complete model example: M1M-2TAZ664052R0007 (2TAZ664052R0007 is the ABB original order number / material code)

Posicionamiento del producto

ABB’s new-generation modular DIN-rail mounted multifunction power monitoring meters, used for energy metering, power quality analysis, and electrical parameter monitoring in mediumand low-voltage primary and secondary distribution systems. Supports Modbus communication and is suitable for industrial and building applications.

  1. Full Series Comparison
ModeloFunciones centralesInterfaz de comunicaciónI/OSupply VoltageSample Order No.
M1M 10Basic energy measurement, no displayNingunoNingunoNo auxiliary power required2TAZ661010R2000
M1M 12Basic energy measurement, LED indicationNingunoNingunoNo auxiliary power required2TAZ661210R2000
M1M 15Multifunction measurement, pantalla LCDOptional ModbusNinguno100–230V AC/DC2TAZ661510R2000
M1M 20Multifunction measurement, pantalla LCDOptional ModbusNinguno100–230V AC/DC2TAZ662010R2000
M1M 30Advanced measurement, power quality analysisOptional Modbus/EthernetOptional 2DI/2DO100–230V AC/DC2TAZ663010R2000
M1M 30 I/OAdvanced measurement + I/O controlModbus RTU2DI/2DO100–230V AC/DC2TAZ663012R2001
M1M 30 EthernetAdvanced measurement + EthernetModbus TCP/IPNinguno100–230V AC/DC2TAZ663011R2001
  1. Especificaciones técnicas (M1M 30 Serie)

Measurement accuracy: Current/voltage class 0.2, active energy class 0.5S (Cumple con IEC 62053-22), reactive energy class 2

Measured parameters: Three-phase voltage/current, active/reactive/apparent power, factor de potencia, frecuencia, medición de energía (forward/reverse), harmonic analysis (modelos seleccionados)

CT input: Standard 1A/5A, supports star (3E) o delta (2E) conexión

Protección de ingreso: IP51 (panel frontal), IP20 (terminales)

Montaje: 35carril DIN mm, 18mm de ancho (1 módulo)

  1. Core Application Scenarios
  2. Sub-metering in commercial buildings (iluminación, climatización, power circuits)
  3. Power distribution system monitoring and energy efficiency analysis in industrial plants
  4. Power quality monitoring in data centers
  5. Real-time electrical parameter monitoring in low-voltage distribution cabinets
  6. Power generation metering for renewable energy systems (PV / wind power)
  7. Modelos alternativos & Brand Comparison

Upgraded Alternatives (Misma marca)

Function expansion: ABB M2M series (higher accuracy, more communication protocols)

Versión básica: ABB M1M 10/12 (basic energy metering, lower cost)

Cross-Brand Alternatives

MarcaRecommended ReplacementCompatibility Notes
SchneiderPowerLogic PM5000 seriesSimilar functions, compatible communication protocols
siemensSENTRON PAC seriesComparable measurement accuracy, supports Modbus
Alternativas domésticasAcrel PZ series, Chint DTSU seriesCost advantage, compatible basic functions
  1. Selection Guidelines
  2. Measurement needs: Basic energy metering → M1M 10/12; real-time monitoring → M1M 15/20; power quality analysis → M1M 30
  3. Communication needs: Remote monitoring → models with Modbus (M1M 15/20/30)
  4. Control needs: Digital input/output required → M1M 30 I/O
  5. Installation environment: Ensure operating temperature range (-25°C to +55°C) and protection class requirements

Complete List of ABB Multifunction Power Meters

This list covers ABB’s mainstream multifunction power meter series, sorted from basic metering to advanced power quality analysis by product positioning. Includes model numbers, core functions, parámetros técnicos, order numbers, and application scenarios for easy selection and procurement reference.

  1. M1M Series (System pro M, Modular DIN-Rail Mounted)

ABB’s new-generation compact multifunction power meters for mediumand low-voltage primary and secondary distribution systems. Only 18mm wide (1 módulo) and supports hot-swap.

I.1 Basic Metering Type (Sin visualización / LED Indication)

ModeloFunciones centralesClase de precisiónComunicaciónI/OPower SupplySample Order No.Solicitud
M1M 10Three‑phase energy measurement (no display)Active 0.5S, Reactive 2NingunoNingunoNo auxiliary power2TAZ661010R2000Basic energy statistics, low‑cost applications
M1M 12Three‑phase energy measurement (LED status indication)Active 0.5S, Reactive 2NingunoNingunoNo auxiliary power2TAZ661210R2000Simple circuit monitoring, fault indication

I.2 Multifunction Display Type (LCD Display)

ModeloFunciones centralesClase de precisiónComunicaciónI/OPower SupplySample Order No.Solicitud
M1M 15Three‑phase full‑electrical measurement, pantalla LCDActive 0.5S, Reactive 2Optional Modbus RTUNinguno100–230V AC/DC2TAZ661512R2000Sub‑metering in commercial buildings, industrial monitoring
10239994
M1M 15 I/OFull‑electrical measurement + 2DI/2DOActive 0.5S, Reactive 2Modbus RTU2DI/2DO100–230V AC/DC2TAZ661512R2001Local alarm/control, equipment interlock
M1M 20Full‑electrical + THD measurement, pantalla LCDActive 0.2S, Reactive 2Optional Modbus RTUNinguno100–230V AC/DC2TAZ662012R2000Industrial energy efficiency analysis, power quality monitoring
10239996
M1M 20 I/OFull‑electrical + THD + 2DI/2DOActive 0.2S, Reactive 2Modbus RTU2DI/2DO100–230V AC/DC2TAZ662012R2001Local control, alarm output
M1M 20 EthernetFull‑electrical + THD + EthernetActive 0.2S, Reactive 2Modbus TCP/IPNinguno100–230V AC/DC2TAZ662014R2000Network integration, monitoreo remoto

I.3 Advanced Power Quality Type

ModeloFunciones centralesClase de precisiónComunicaciónI/OPower SupplySample Order No.Solicitud
M1M 30Full‑electrical + harmonic analysis (up to 40th), registro de datosActive 0.2S, Reactive 2Optional Modbus RTUNinguno100–230V AC/DC2TAZ663012R2000Power quality analysis, energy optimization
10239997
M1M 30 I/OFull functions + 2DI/2DOActive 0.2S, Reactive 2Modbus RTU2DI/2DO100–230V AC/DC2TAZ663012R2001Local control + alarma, equipment interlock
M1M 30 EthernetFull functions + EthernetActive 0.2S, Reactive 2Modbus TCP/IPNinguno100–230V AC/DC2TAZ663014R2000Remote power quality monitoring, system integration
M1M 30 I/O EthernetFull functions + 2DI/2DO + EthernetActive 0.2S, Reactive 2Modbus RTU/TCP2DI/2DO100–230V AC/DC2TAZ663014R2001Smart power distribution systems, energy management

Special model: M1M-2TAZ664052R0007 (custom version of M1M series, order no. 2TAZ664052R0007), functions equivalent to M1M 30, for specific project requirements.

  1. M2M Series (System pro M compact, Panel Mounted)

ABB mid-range power quality analyzers, 96mm wide (4 módulos), suitable for mounting on distribution cabinet doors. Fully functional with advanced power quality analysis.

ModeloFunciones centralesClase de precisiónComunicaciónI/OAnálisis armónicoData LoggingSample Order No.Solicitud
M2M 10Full‑electrical measurement, pantalla LCDActive 0.2S, Reactive 2Modbus RTU2DI/2DOUp to 31stBasic logging2CSG299883R4052Industrial power monitoring, energy efficiency analysis
M2M 20Power quality analysis, event recordingActive 0.1S, Reactive 2Modbus RTU/TCP4DI/4DOUp to 40thAdvanced logging2CSG299884R4052Critical load monitoring, diagnóstico de fallas
M2M 30Advanced power quality, PQDIF exportActive 0.05S, Reactive 2Modbus RTU/TCP8DI/8DOUp to 63rdComprehensive logging2CSG299885R4052Data centers, critical production equipment
Ethernet/IP

III. M4M Series (Network Analyzers)

ABB high-end power quality analyzers, standalone installation, for mediumand high-voltage distribution systems, providing complete power quality analysis and energy management.

ModeloFunciones centralesClase de precisiónComunicaciónI/OAnálisis armónicoData LoggingSolicitud
M4M 100Full parameter measurement, power quality analysisActive 0.02S, Reactive 1Modbus RTU/TCP16DI/16DOUp to 63rdLarge‑capacity storageMedium‑/high‑voltage distribution, grid monitoring
DNP3
M4M 200Advanced power quality, power quality reportingActive 0.01S, Reactive 1Modbus RTU/TCP24DI/24DOUp to 127thMassive storageGrid custody metering, power trading
DNP3
CEI 61850

 

  1. D1M Series (System pro M Distributed Monitoring)

ABB distributed power monitoring system supporting centralized monitoring of multiple circuits, ideal for large buildings and industrial plants, with remote management via gateways.

ModeloFunciones centralesMonitored CircuitsComunicaciónI/OPower SupplySolicitud
D1M 10Centralized monitoring of 4 circuitos4×three‑phaseModbus RTU8DI/4DO24En DCCommercial buildings, multi‑story plants
D1M 20Centralized monitoring of 8 circuitos8×three‑phaseModbus RTU/TCP16DI/8DO24En DCLarge shopping malls, industrial parks
  1. EM Series (Smart Power Meters)

ABB economical multifunction power meters for small buildings and industrial applications, cost-effective and flexible installation.

ModeloFunciones centralesClase de precisiónComunicaciónI/OPower SupplySolicitud
EM 20Single‑phase current/voltage measurementActive 1, Reactive 2NingunoNingunoNo auxiliary powerResidential, small shops
EM 100Single‑phase full‑electrical measurementActive 0.5S, Reactive 2Optional Modbus2DI/2DO100–230V AC/DCSmall commercial, lighting circuits
EM 200Three‑phase full‑electrical measurementActive 0.5S, Reactive 2Optional Modbus4DI/4DO100–230V AC/DCSmall factories, edificios de oficinas
EM 400Three‑phase full‑electrical + salida analógicaActive 0.2S, Reactive 2Optional Modbus4DI/4DO100–230V AC/DCProcess control, equipment interlock
2HACIA
  1. Other Series (Special Applications)
SerieModeloFunciones centralesEscenarios de aplicación
IM SeriesIM302Smart power monitoring, event recordingAutomatización industrial, equipment monitoring
LNP3 SeriesLNP301Energy metering, remote meter readingPublic utilities, redes inteligentes
PMU SeriesPMU6000Multifunction measurement, power quality analysisLarge‑scale industry, energy management

VII. Guía de selección (Por aplicación)

  1. Basic energy metering: Choose M1M 10/12 or EM 20/100, bajo costo, meets basic statistical needs
  2. General power monitoring: Choose M1M 15/20 or M2M 10, funciones completas, supports Modbus communication
  3. Power quality analysis: Choose M1M 30 or M2M 20/30, harmonic analysis up to 40th/63rd, supports event recording
  4. Medium-/high-voltage distribution: Choose M4M series, high-accuracy measurement, complete power quality analysis, supports IEC 61850
  5. Multi-circuit centralized monitoring: Choose D1M series, distributed architecture, reduces wiring and costs-

VIII. Core Technical Parameter Comparison

SerieMeasurement AccuracyAnálisis armónicoCommunication ProtocolsI/O CapacityMontajeAncho
M1M0.5S ~ 0.2SUp to 40thModbus RTU/TCP0~2DI/2DOCarril DIN18milímetros
M2M0.2S ~ 0.05SUp to 63rdModbus RTU/TCP

Ethernet/IP

2~8DI/DOPanel mount96milímetros
M4M0.02S ~ 0.01SUp to 127thModbus RTU/TCP

DNP3

CEI 61850

16~24DI/DOStandalone / 19″ rack19″
D1M0.5SUp to 31stModbus RTU/TCP8~16DI/DOCarril DIN72milímetros
EM0.5S ~ Class 1Up to 15thOptional Modbus0~4DI/DOCarril DIN36milímetros