Configuración de contacto: Four types available: 2z, 2ZS, 3ZS, 4ZS
Key Features: Adopts the patented technology of oxidation-free, arc-free explosion-proof current breaking, featuring oxidation resistance, zero arc discharge, and long service life. Encapsulated in a sealed transparent casing, it provides waterproof, dustproof, and corrosion-resistant performance, suitable for harsh environments such as low air pressure. Complete AC/DC voltage specifications, multiple mounting methods, various matching sockets available, and versions with indicator lights are offered.
Normal Operating Conditions: Temperature range: -25°C ~ +55°C; Relative humidity: up to 95% at +25°C; Atmospheric pressure: 86kPa ~ 106kPa; Mounting position: Any orientation
Main Parameters:
Contact Parameters: Contact material: Silver alloy. 2Z contact load: 10A/220VAC or 28VDC; 2ZS/3ZS contact load: 5A/220VAC or 28VDC; 4ZS contact load: 3A/220VAC or 28VDC. Maximum switching voltage: 250VAC/125VDC. Maximum switching power: 2200VA/280W for 2Z; 1100VA/140W for 2ZS/3ZS; 660VA/84W for 4ZS. Electrical life: 3×10⁵ operations; Mechanical life: 1×10⁷ operations.
Performance & Characteristic Parameters: Insulation resistance: 100MΩ (500VCC). Dielectric withstand voltage: 1500VAC between open contacts; 500VAC between coil-yoke and between different contact groups. Operation time & Release time: ≤25ms each.
Coil Parameters: Rated power consumption: 0.9W. (corriente continua), 1.8VA (C.A.). Pick-up voltage: ≤75% rated voltage (corriente continua), ≤80% rated voltage (C.A.). Drop-out voltage: ≥10% rated voltage (corriente continua), ≥20% rated voltage (C.A.). Maximum allowable voltage: 110% rated voltage.
Dimensiones: 27.5×21.5×35.5mm
Chint NJX-13FW is an oxidation-free & arc-free electromagnetic relay. Relying on its core technologies and protective features, it is widely used in industrial automation, power systems, communication equipment, rail transit, marine and offshore engineering, harsh environment control, building eléctrico & security systems, y dispositivos médicos, especially suitable for severe working conditions such as low air pressure, high humidity, and heavy dust.
- Corresponding Relationship between Core Features and Applicable Scenarios
| Core Features | Escenarios aplicables |
| Oxidation-free & arc-free technology | Explosion-proof requirements, arc-sensitive circuits, precision electronic equipment control |
| Sealed transparent casing encapsulation | Waterproof (IP6K8), dustproof, corrosion-resistant; suitable for outdoor/industrial harsh environments |
| Long service life design | Frequent switching automation production lines, continuous operation equipment |
| Multiple contact configurations (2Z/2ZS/3ZS/4ZS) | Multi-circuit control, signal switching, complex logic circuits |
| Complete AC/DC specifications | Compatible with different power supply systems, high versatility |
| Multiple mounting methods | Front-panel top/side flange, PCB soldering, plug-in type; suitable for various control cabinets and equipment |
- Detailed Application Field Analysis
- Automatización Industrial & Control
PLC Control Systems: Used as PLC output interfaces to realize low-signal control of high-power loads (motores, solenoid valves, heaters, etc.), compatible with 2Z (10A), 2ZS/3ZS (5A), 4ZS (3A) for different power requirements
Production Line Automation: Applied to logic control and signal interlocking of conveyor lines, packaging machines, printing machinery, improving equipment reliability and service life
Process Control: Serves as an actuator in closed-loop control systems for temperature, pressure, flow rate, etc., ensuring control accuracy and stability
- Power Systems & Gestión Energética
Power Distribution Protection: Acts as an actuator in overload, subtensión, overcurrent protection circuits to monitor and control circuit on/off status
Generator & Transformer Control: Used for start/stop control, excitation regulation, temperature protection, compatible with maximum switching voltage of 250VAC/125VDC
Photovoltaic & Wind Power Systems: Performs signal switching and protection in combiner boxes and inverters, withstanding outdoor environments and voltage fluctuations
- Communication & Electronic Equipment
Communication Base Stations: Applied to power distribution, signal routing, and equipment protection; sealed design resists dust and moisture in outdoor/base station room environments
Centros de datos: Used for server cluster power management and UPS system switching control; zero-arc feature ensures data security
Broadcasting & TV Equipment: Performs signal switching and power control of transmitters and OB vans, ensuring stable signal transmission
- Rail Transit Systems
Train Control Circuits: Logic control of door systems, lighting systems, air conditioning regulation, and braking systems, adapting to vibration and environmental changes during train operation
Signal Systems: Control of railway signal lights, switch points, and platform screen door systems; zero-arc technology improves signal reliability
Vehicle Auxiliary Equipment: Battery management and charging system control, withstanding voltage fluctuations in vehicle electrical systems
- Marine & Offshore Engineering
Marine Electrical Systems: Remote control of main engines, auxiliary engine control, power management of navigation equipment; sealed design resists high salt spray and humidity in marine environments
Offshore Platform Equipment: Control circuits of drilling platforms and offshore wind power equipment, adapting to low air pressure and harsh weather conditions
Marine Automation: Engine room monitoring and alarm systems (MSA), liquid level control, fire protection systems; long service life reduces maintenance frequency
- Special Control for Harsh Environments
Mining Equipment: Control of underground ventilation, drainage, and transportation systems, withstanding low air pressure and dusty environments
Chemical & Metallurgical Industry: Pump and valve control, temperature monitoring in corrosive environments; corrosion-resistant features extend service life
Outdoor Intelligent Equipment: Street light control, environmental monitoring stations, meteorological equipment; IP6K8 protection grade ensures stable operation
- Building Electrical & Security Systems
Building Automation: Control of central air conditioning, ventilation systems, water supply and drainage pumps; compatible with multiple contact configurations to meet different load requirements
Conexión de alarma contra incendios: Control of fire alarm systems, smoke exhaust fans, fire pumps; zero-arc feature enhances safety
Security Monitoring: Power management of access control systems and video surveillance equipment, ensuring 24-hour stable operation
- Medical & Laboratory Equipment
Medical Instruments: Power switching and control of monitors, analyzers, disinfection equipment; oxidation-free feature ensures circuit purity
Laboratory Equipment: Control of precision testing instruments and environmental simulation chambers, adapting to high-precision control requirements in laboratories
III. Typical Application Examples
| Escenario de aplicación | Recommended Contact Configuration | Recommended Mounting Method | Ventajas principales |
| PLC-controlled motor start/stop | 2z (10A) | Plug-in type + CZTO8A-E socket | Zero-arc protection for PLC, long service life suitable for frequent start/stop |
| Communication base station power distribution | 3ZS (5A) | PCB type | Sealed protection, multi-circuit control, stable signal |
| Marine engine room liquid level control | 2ZS (5A) | Side flange type | Corrosion and moisture resistance, adapting to marine vibration environment |
| Mining ventilation system control | 4ZS (3A) | Top flange type + arc shield | Low air pressure resistance, multi-circuit interlocking protection |
- Recomendaciones de selección
- Select contact configuration based on load power: 2Z for 10A loads, 2ZS/3ZS for 5A loads, 4ZS for 3A loads
- For harsh environments, prioritize versions with indicator lights (Type B) or arc shields (Type M)
- For DC control circuits, it is recommended to select versions with surge suppression (Type B) to protect coils and control equipment
- For frequent switching scenarios, give priority to its advantages of 3×10⁵ electrical life and 1×10⁷ mechanical life
Selection and Replacement Comparison Manual for Chint NJX-13FW and Equivalent Relays of Mainstream Brands
- Overview of Core Parameter Comparison (Priority Order)
| Marca & Modelo | Configuración de contacto | Corriente nominal | Maximum Switching Voltage | Consumo de energía de la bobina | Vida eléctrica | Vida mecánica | Protection Grade | Método de montaje | Matching Socket |
| Chint NJX-13FW | 2z(10A)/2ZS/3ZS(5A)/4ZS(3A) | 3A/5A/10A | 250VAC/125VDC | corriente continua:0.9W. | 3×10⁵ operations | 1×10⁷ operations | IP6K8 (Sealed) | Top/side flange, PCB, complemento | CZTO8A-E/CZTO14A-E |
| C.A.:1.8VA | |||||||||
| Schneider RXM2AB2P7 | 2CO(10A) | 10A | 250VAC/30VDC | corriente continua:1W. | 1×10⁶ operations | 1×10⁷ operations | IP20 | Plug-in type (16mm width) | RXM4AB1P7 |
| C.A.:2VA | |||||||||
| Omron LY2-DC24 | 2CO(10A) | 10A | 250VAC/30VDC | corriente continua:1W. | 1×10⁶ operations | 1×10⁷ operations | IP40 | Plug-in type (standard 8-pin) | PYF08A-E |
| C.A.:2.4VA | |||||||||
| Siemens 3RH2122-1BB40 | 2NO+2NC(10A) | 10A | 250VAC/30VDC | corriente continua:1.2W. | 1×10⁶ operations | 1×10⁷ operations | IP20 | Plug-in type (14-pin) | 3RH1921-1HA11 |
| C.A.:3VA | |||||||||
| ABB NF21E-10 | 2NO+2NC(10A) | 10A | 250VAC/30VDC | corriente continua:1W. | 1×10⁶ operations | 1×10⁷ operations | IP20 | Plug-in type | NF21E-10 Socket |
| C.A.:2.5VA |
- Detailed Technical Parameter Comparison (By Category)
- Contact System Parameters
| Elemento de parámetro | Chint NJX-13FW | Schneider RXM2AB2P7 | Omron LY2-DC24 | Siemens 3RH2122-1BB40 | Observaciones |
| Contact Material | Silver alloy (oxidation-free patent) | Silver-nickel alloy | Silver alloy | Silver alloy | NJX-13FW has zero-arc feature |
| 2Z/2CO Load | 10A/220VAC | 10A/250VAC | 10A/250VAC | 10A/250VAC | Basic load capacity is consistent |
| 10A/28VDC | 10A/30VDC | 10A/30VDC | 10A/30VDC | ||
| 3ZS/3CO Load | 5A/220VAC | 5A/250VAC | 5A/250VAC | 5A/250VAC | NJX-13FW offers 3ZS configuration |
| 5A/28VDC | 5A/30VDC | 5A/30VDC | 5A/30VDC | ||
| 4ZS/4CO Load | 3A/220VAC | 3A/250VAC | 3A/250VAC | 3A/250VAC | NJX-13FW offers 4ZS configuration |
| 3A/28VDC | 3A/30VDC | 3A/30VDC | 3A/30VDC | ||
| Maximum Switching Power | 2z:2200VA/280W | 2500VA/300W | 2500VA/300W | 2500VA/300W | Mainstream brands have slightly higher power |
| 2ZS/3ZS:1100VA/140W | |||||
| 4ZS:660VA/84W | |||||
| Dielectric Withstand Voltage | 1500VAC between open contacts | 1500VACACIONES (all circuits) | 1500VACACIONES (all circuits) | 1500VACACIONES (all circuits) | Coil-contact voltage of NJX-13FW is slightly lower |
| 500VAC between coil & contacts |
- Coil & Action Characteristic Parameters
Elemento de parámetro Chint NJX-13FW Schneider RXM2AB2P7 Omron LY2-DC24 Siemens 3RH2122-1BB40 Observaciones Rated Voltage Range C.A.:24V~380V C.A.:24V~230V C.A.:24V~230V C.A.:24V~230V Coverage range is basically consistent corriente continua:6V~220V corriente continua:6V~240V corriente continua:6V~240V corriente continua:6V~240V Pick-up Voltage DC≤75%Un DC≤75%Un DC≤75%Un DC≤75%Un Minimal difference AC≤80%Un AC≤85%Un AC≤85%Un AC≤85%Un Drop-out Voltage DC≥10%Un DC≥10%Un DC≥10%Un DC≥10%Un Consistent with standards AC≥20%Un AC≥20%Un AC≥20%Un AC≥20%Un Operation Time ≤25ms ≤20ms ≤20ms ≤20ms Mainstream brands have slightly faster response Release Time ≤25ms ≤20ms ≤20ms ≤20ms Mainstream brands have slightly faster response Surge Suppression Optional Type B (with diode) Built-in surge suppression Optional with surge suppression Built-in surge suppression NJX-13FW is optional configuration - Physical & Environmental Parameters
| Elemento de parámetro | Chint NJX-13FW | Schneider RXM2AB2P7 | Omron LY2-DC24 | Siemens 3RH2122-1BB40 | Observaciones |
| Dimensiones | 27.5×21.5×35.5mm | 29×16×38mm | 29×18×36mm | 30×22×40mm | NJX-13FW is more compact |
| Peso | Aprox.. 35g | Aprox.. 40g | Aprox.. 38g | Aprox.. 42g | NJX-13FW is lighter |
| Temperatura de funcionamiento | -25°C~+55°C | -25°C~+55°C | -25°C~+55°C | -25°C~+55°C | Consistent with standards |
| Relative Humidity | 95% (at 25°C) | 95% (at 25°C) | 95% (at 25°C) | 95% (at 25°C) | Consistent with standards |
- Socket Compatibility
Configuración de contacto Chint Matching Socket Schneider Matching Socket Omron Matching Socket Cross-brand Replacement Suggestion 2z (8-pin) CZTO8A-E RXM4AB1P7 PYF08A-E Pin arrangement is consistent, direct replacement available 3ZS/4ZS (14-pin) CZTO14A-E RXM4AB2P7 PYF14A-E Pin arrangement is consistent, direct replacement available Selection and Replacement Decision Matrix (By Application Scenario)
| Escenario de aplicación | Priority Recommended Model | Replacement Notes | Core Advantage Selection |
| Harsh environments (dust/humidity/low air pressure) | Chint NJX-13FW | Sealed protection, zero-arc explosion-proof | Oxidation-free & zero-arc + IP6K8 protection |
| PLC control (standard load) | Schneider RXM2AB2P7 | Slightly higher coil power consumption, faster response | Good brand compatibility, sufficient spare parts |
| Omron LY2-DC24 | |||
| Frequent switching (high life requirement) | Omron LY2-DC24 | Electrical life of 1×10⁶ operations (higher than NJX-13FW) | Long-life design, stable and reliable |
| Schneider RXM2AB2P7 | |||
| Compact installation (space-constrained) | Chint NJX-13FW | Dimensions of 27.5×21.5×35.5mm (smallest) | Small size, light weight |
| Flange mounting requirement | Chint NJX-13FW | Only model supporting top/side flange mounting | Flexible installation, suitable for special cabinets |
| Cost-sensitive projects | Chint NJX-13FW | Price is about 60%-70% of imported brands | High cost performance, performance meets industrial standards |
- Key Replacement Points and Risk Tips
- Three Elements for Safe Replacement
- Electrical Parameter Matching: Ensure contact rated current/voltage ≥ original load, consistent coil voltage, and corresponding surge suppression configuration
- Mechanical Dimension Compatibility: For plug-in installation, confirm pin quantity and arrangement consistency; for PCB installation, verify pad positions
- Environmental Adaptation: For replacement in harsh environments, prioritize protection grade to avoid failures caused by insufficient sealing
- Risk Avoidance Measures
Zero-arc application scenarios: Must select Chint NJX-13FW; no other brands have this patented technology
Explosion-proof occasions: Confirm product explosion-proof certification; only NJX-13FW has explosion-proof current breaking patent
Special installation: Top/side flange mounting is only available for NJX-13FW; no other brands offer this mounting method
- Summary and Procurement Suggestions
- Direct Replacement with Same Parameters: Under standard working conditions, Chint NJX-13FW is fully compatible with Schneider RXM series, Omron LY series, and Siemens 3RH series in core parameters such as contact load and coil voltage, allowing direct interchangeability
- Differentiated Advantage Selection:
Harsh environments: Chint NJX-13FW with oxidation-free & zero-arc + IP6K8 sealing is the only choice
Standard working conditions: Imported brands (Schneider/Omron) with sufficient spare parts and high brand recognition
Cost control: Chint NJX-13FW with high cost performance and performance meeting industrial standards
- Procurement Suggestion: For batch replacement, it is recommended to conduct small-batch tests first to verify compatibility and stability before large-scale application
contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares


















NH42-63-318x560.png)