Chint NKB8-32/8A-32A/AC220V is a Control and Protective Switching Device (CPS) that integrates the functions of a contactor, cortacircuitos, and motor protector. It is specifically designed for power systems with an AC frequency of 50Hz and a rated voltage up to 690V, and is particularly suitable for the control and protection of 3~15kW motors. La siguiente es su información principal y pautas de aplicación.:
- Funciones principales y parámetros técnicos
- Protection Module (CTU-1D32D)Precio de los relés de sobrecarga térmica de la serie Chint NXR
Protección contra sobrecarga: The setting range is 8~32A (corresponding to 3~15kW motors with 400V/AC-43 loads), supporting the adjustment of inverse time curves to avoid frequent misoperations.
Protección instantánea contra cortocircuitos: Instantaneous tripping at 16 veces la corriente nominal (16Es decir) with a response time of <0.1 artículos de segunda clase, and the breaking capacity reaches 50kA (400V).
Intelligent protection functionsPrecio del disyuntor CHINT:
– Protección contra pérdida de fase: Triggers tripping within 5 artículos de segunda clase (valor predeterminado) when a phase loss is detected.
– Three-phase imbalance protection: The threshold can be set (10%~100%), and it acts within 10 seconds when the default imbalance degree of 35% is reached.
– Locked rotor/blocking protection: Locked rotor protection is for the starting process (5~9Ie, 2-second delay), and blocking protection is for abnormalities during operation (5~9Ie, 2-second delay).
– Under-current/under-voltage protection: The under-current protection can be set to 20%~80% of the rated current (80% por defecto), and the under-voltage protection is 70%~90% of the rated voltage (80% por defecto).
- Power Base Module (PBU1T32)Precio del contactor CHINT
Corriente nominal: 32A, suitable for 3~15kW motors under 400V/AC-43 working conditions.
Controlar la fuente de alimentación: AC220V is directly controlled through A1/A2 terminals, or independently powered through A3/A4 terminals.
Capacidad de ruptura: The short-circuit breaking capacity under AC-43 working conditions is 50kA, meeting industrial-grade requirements.
- Diseño modularPrecio del protector contra sobretensiones CHINT
– Adopts a split structure, with the transformer module and main control unit installed separately, supporting 35mm guide rail or screw fixation, ahorro de espacio en el armario de control.
– Expandable communication functions (such as ModBus-RTU protocol) para realizar monitoreo remoto.
- Installation and Operation
- Especificaciones de cableado
Circuito principal: The terminal blocks are suitable for 4~16mm² wires, with L1/L2/L3 as the incoming ends and T1/T2/T3 as the outgoing ends.
circuito de control: Use 0.75~1.5mm² wires, A1/A2 are connected to the AC220V control power supply, and A3/A4 can be optionally equipped with independent power supply.
Requisitos de conexión a tierra: Ensure reliable grounding, with a grounding resistance ≤4Ω.
- Configuración de parámetros
– Enter the menu through the panel buttons (Ent/∧/∨/Esc) to adjust parameters such as overload current and delay time. Por ejemplo, set the overload protection current to 1.1 veces la corriente nominal del motor, and the delay time matches the starting characteristics of the load.
– Supports manual reset (panel buttons) y reinicio remoto (entrada de señal externa), y bloquea automáticamente el valor actual después de una falla para su análisis.
- Monitoreo de estado
Indicadores LED:(mostrar visualmente el estado del suministro de energía, operación, sobrecarga, Voltaje, etc.).
Visualización de datos: Muestra cíclicamente el valor promedio de la corriente trifásica y la corriente en tiempo real de las fases A/B/C., con un error de <±2%.
III. Escenarios de aplicación y sugerencias de selección
- Aplicaciones típicas
campo industrial: Protección de motores asíncronos trifásicos como ventiladores, bombas de agua, y grúas, especialmente indicado para cargas con arranques frecuentes (como cintas transportadoras).
Edificios comerciales: Ahorro energético y protección de compresores de aire acondicionado y motores de ascensores., que se puede conectar al sistema de automatización del edificio a través de interfaces de comunicación.
Solución alternativa: Reemplace el relé térmico tradicional. + combinación de contactores, reduciendo el espacio del gabinete y mejorando la precisión de la protección.
- Puntos de selección
Coincidencia de poder: Select the corresponding model according to the rated current of the motor. CTU-1D32D is suitable for 3~15kW (400V) motors to avoid reduced protection sensitivity due to over-selection.
Adaptabilidad ambiental: A heat dissipation module is required for high-temperature environments (>50℃), and a cabinet with IP54 protection level is recommended for high-humidity environments.
Requisitos de certificación: For export to the North American market, it is necessary to confirm whether it has passed UL certification (you can contact Chint customer service for the latest certification information).
- Mantenimiento y solución de problemas
- Mantenimiento diario
– Clean the housing and terminal blocks quarterly, and check whether the terminals are loose.
– Use a multimeter to detect whether the voltage of the control circuit is stable (AC220V±10%) to avoid misoperation caused by voltage fluctuations.
- Solución de problemas de fallas comunes
falso tropiezo: Check if the load is overloaded for a short time, o ajustar la curva de tiempo inverso para extender el tiempo de acción.
Sin pantalla: Confirme si la fuente de alimentación de control es normal, y verifique el voltaje de los terminales A1/A2 y si el fusible está fundido.
interrupción de la comunicación: Verifique si el cableado RS485 es correcto y si la configuración de velocidad en baudios es consistente con la computadora superior.
- Soporte oficial
– Los usuarios de Norteamérica pueden comprar a través de distribuidores locales u obtener soluciones personalizadas a través de Whatsapp: 0086-13811255435.
- Cumplimiento y Certificación
Normas nacionales: Cumple con GB14048.9 “Aparamenta de baja tensión y control” y ha pasado la certificación CQC.
Certificación internacional: Se recomienda que los usuarios exportadores confirmen con antelación los requisitos de certificación del mercado objetivo. (como UL, CE), y puede solicitar versiones de certificación personalizadas a través de los canales oficiales de Chint..
Resumen: Con su diseño integrado, protección de alta precisión, y configuración flexible, NKB8-32/8A-32A/AC220V has become the preferred solution for motor control and protection in industrial and commercial fields. When selecting and using, a comprehensive evaluation should be made in combination with load characteristics, condiciones ambientales, and certification requirements to achieve the best protection effect.
Chint CTU1-32 motor protector is the core component of the NKB8 series control and protection switching devices, specially providing comprehensive protection for motors. The following is its key information and application guidelines:
- Funciones principales y parámetros técnicos
- Funciones de protección
Protección contra sobrecarga: Supports definite time and inverse time actions, with the overload current setting range of 3~12A (corresponding to 1.1~5.5kW motors with 400V/AC-43 loads). The inverse time curve can be adjusted according to load characteristics to avoid frequent misoperations.
Protección instantánea contra cortocircuitos: Instantaneous tripping at 16 veces la corriente nominal (16Es decir) with a response time of <0.1 artículos de segunda clase, effectively preventing the expansion of short-circuit faults.
Phase loss/open-phase protection: Triggers tripping within 5 artículos de segunda clase (valor predeterminado) after detecting a power failure in any phase, avoiding motor burnout due to phase loss.
Three-phase imbalance protection: The imbalance threshold can be set (10%~100%), and it acts within 10 seconds when the default imbalance degree of 35% is reached.
Locked rotor/blocking protection: Locked rotor protection is for the starting process (5~9 times the rated current, 2-second delay), and blocking protection is for abnormalities during operation (5~9 times the rated current, 2-second delay).
Under-current/under-voltage protection: The under-current protection can be set to 20%~80% of the rated current (80% por defecto), and the under-voltage protection is 70%~90% of the rated voltage (80% por defecto).
- Parámetros eléctricos
Corriente nominal: 32A, suitable for 3~15kW motors under 400V/AC-43 working conditions.
Capacidad de ruptura: The short-circuit breaking capacity under AC-43 working conditions reaches 50kA (400V), meeting industrial-grade short-circuit protection requirements.
Controlar la fuente de alimentación: Powered by AC220V, which can be directly controlled through A1/A2 terminals or independently powered through A3/A4 terminals.
- Diseño modular
– Adopts a split structure, with the transformer module and main control unit installed separately, supporting 35mm guide rail or screw fixation, ahorro de espacio en el armario de control.
– Expandable communication functions (such as ModBus-RTU protocol) to realize remote monitoring and data collection.
- Installation and Operation
- Requisitos de instalación
Condiciones ambientales: Operating temperature -30℃~70℃, humedad <90%, avoiding strong electromagnetic interference and corrosive gases.
Especificaciones de cableado: The main circuit terminals are suitable for 4~16mm² wires, and the control circuit uses 0.75~1.5mm² wires, ensuring reliable grounding.
Método de instalación: The transformer module is directly connected in series to the main circuit of the motor, and the main control unit is fixed on the control cabinet panel through a buckle, supporting embedded or rail installation.
- Configuración de parámetros
– Enter the menu through the panel buttons (Ent/∧/∨/Esc) to adjust parameters such as overload current, tiempo de retraso, and protection threshold. Por ejemplo, set the overload protection current to 1.1 veces la corriente nominal del motor, and the delay time matches the starting characteristics of the load.
– Supports manual reset (panel buttons) y reinicio remoto (entrada de señal externa), y bloquea automáticamente el valor actual después de una falla para su análisis.
- Monitoreo de estado
Indicadores LED: The status of power supply, operación, sobrecarga, Voltaje, etc., is visually displayed through different color LEDs.
Visualización de datos: Muestra cíclicamente el valor promedio de la corriente trifásica y la corriente en tiempo real de las fases A/B/C., con un error de <±2%.
III. Escenarios de aplicación y sugerencias de selección
- Aplicaciones típicas
Equipos industriales: Protección de motores asíncronos trifásicos como ventiladores, bombas de agua, y grúas, especialmente indicado para cargas con arranques frecuentes (como cintas transportadoras).
Edificios comerciales: Ahorro energético y protección de compresores de aire acondicionado y motores de ascensores., que se puede conectar al sistema de automatización del edificio a través de interfaces de comunicación.
Solución alternativa: Can replace the traditional thermal relay + combinación de contactores, reduciendo el espacio del gabinete y mejorando la precisión de la protección.
- Puntos de selección
Coincidencia de poder: Select the corresponding model according to the rated current of the motor. CTU1-32 is suitable for 3~15kW (400V) motors to avoid reduced protection sensitivity due to over-selection.
Adaptabilidad ambiental: A heat dissipation module is required for high-temperature environments (>50℃), and a cabinet with IP54 protection level is recommended for high-humidity environments.
Requisitos de certificación: For export to the North American market, it is necessary to confirm whether it has passed UL certification (you can contact Chint customer service for the latest certification information).
- Mantenimiento y solución de problemas
- Mantenimiento diario
– Clean the housing and terminal blocks quarterly, and check whether the terminals are loose.
– Use a multimeter to detect whether the voltage of the control circuit is stable (AC220V±10%) to avoid misoperation caused by voltage fluctuations.
- Solución de problemas de fallas comunes
falso tropiezo: Check if the load is overloaded for a short time, o ajustar la curva de tiempo inverso para extender el tiempo de acción.
Sin pantalla: Confirme si la fuente de alimentación de control es normal, y verifique el voltaje de los terminales A1/A2 y si el fusible está fundido.
interrupción de la comunicación: Verifique si el cableado RS485 es correcto y si la configuración de velocidad en baudios es consistente con la computadora superior.
- Soporte oficial
– Users in North America can obtain customized solutions via Whatsapp: 0086-13811255435.
- Cumplimiento y Certificación
Normas nacionales: Cumple con GB14048.9 “Aparamenta de baja tensión y control” y ha pasado la certificación CQC.
Certificación internacional: Se recomienda que los usuarios exportadores confirmen con antelación los requisitos de certificación del mercado objetivo. (como UL, CE), y puede solicitar versiones de certificación personalizadas a través de los canales oficiales de Chint..
Resumen: With its modular design, protección de alta precisión, y configuración flexible, the CTU1-32 motor protector has become the preferred solution for motor protection in industrial and commercial fields. When selecting and using, a comprehensive evaluation should be made in combination with load characteristics, condiciones ambientales, and certification requirements to achieve the best protection effect.
contactor,cortacircuitos,sensor,Codificador,SOCIEDAD ANÓNIMA,Convertidor














NH42-63-318x560.png)