Arrancador suave Danfoss MCD202-015-T4-CV1 - contactor,cortacircuitos,sensor,Codificador,SOCIEDAD ANÓNIMA,Convertidor

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

Arrancador suave Danfoss MCD202-015-T4-CV1 - contactor,cortacircuitos,sensor,Codificador,SOCIEDAD ANÓNIMA,Convertidor

SOCIEDAD ANÓNIMA/

Arrancador suave Danfoss MCD202-015-T4-CV1

(Número de material: 175G5221) VLT® Compact Starter MCD202 Compact Soft Starter Short model code: MCD202015T4CV1 ✅ Model Code Explanation MCD202: MCD202 series, inicio del límite actual + built-in motor protection (different from MCD201; MCD201 only has voltage ramp, no built-in motor overload protection) 015: Clasificado 15 kW T: trifásico 4: Main circuit voltage 200–440 VAC CV1: Control ...

  • Detalles del producto

(Número de material: 175G5221)

VLT® Compact Starter MCD202 Compact Arrancador suave

Short model code: MCD202015T4CV1

✅ Explicación del código del modelo

MCD202: MCD202 series, inicio del límite actual + built-in motor protection (different from MCD201; MCD201 only has voltage ramp, no built-in motor overload protection)

015: Clasificado 15 kilovatios

t: trifásico

4: Main circuit voltage 200–440 VAC

CV1: Controlar el suministro 24 VCA/CC

Frame A, Montaje en carril DIN (specifications ≤30 kW support DIN rail mounting)

✅ Especificaciones eléctricas básicas

Suitable motor power: 15 kilovatios

Corriente nominal: 34 A

Main supply: 3×200~440 VAC (-15% / +10%), 45–66Hz

Controlar el suministro: 24 VCA/CC

Start mode: Current-limited start + TVR timed voltage ramp soft stop

Bypass incorporado: Sí; bypasses SCR after start completion to reduce heat loss

Funciones de protección: Sobrecarga del motor (default Class 10), over-temperature, phase sequence loss, pérdida de fase, SCR fault, motor PTC thermistor input

Starting capability: Standard 4×Ie for 6 s; heavy-duty mode 4×Ie for 20 s

método de control: 2-cable / 3-wire start-stop, salida de relé

Peso neto: 2.4 kilos; gross weight: 2.9 kilos

Temperatura ambiente de funcionamiento: Arriba a 50 °C without derating

✅ Aplicaciones típicas

bombas de agua, fans, transportadores, compresores. Ideal for scenarios requiring current-limited starting to reduce grid inrush, without needing an external thermal relay.

✅ Comparación entre series & Notas de reemplazo

  1. MCD202-015-T4-CV3: Control supply 110–440 VAC (CV3 version, más común). Not CV1; control circuits cannot be directly interchanged.
  2. MCD201-015-T4-CV1: Same power and voltage rating, but MCD201 has no built-in motor protection and fewer functions.
  3. Successor replacement: The MCD200 series is end-of-life. New projects are recommended to use the MCD600 series equivalent.

✅ Fault Quick Reference (Common for MCD202)

Errar 1: Sobretemperatura

Errar 2: Sobrecarga del motor

Errar 4: Pérdida de fase / desequilibrio actual

Errar 5: Start timeout

Errar 6: SCR fault

Errar 10: PTC motor overheat

✅ Start and stop times are adjustable. The MCD202 uses rotary dip-knob adjustment (no menu display panel).

Nota: The MCD201 does not support soft stop. Only the MCD202 features TVR voltage-type soft stop.

Parameter Ranges (Manual MG17C241)

  1. Start ramp-up time (Ramp Up): 2~20 s, predeterminado de fábrica 10 s

Operating logic: Current limiting is primary, voltage ramp is secondary; current ramp can also be enabled (2/5/15 s preset gears)

  1. Soft stop time (Soft Stop / Ramp Down): 2~20 s by gear selection; can also be set to soft stop disabled for direct power-off shutdown (predeterminado de fábrica: soft stop disabled)

Método de ajuste

Four adjustment knobs on the front face:

Perilla 1: Corriente nominal del motor

Perilla 2: Límite de corriente inicial

Perilla 3: Start ramp-up time (Ramp Up)

Perilla 4: Soft stop ramp-down time (Soft Stop)

Brief Application Guidance (Most common for pump applications)

aficionados: 5–10 s start time; soft stop is usually not required

Centrifugal pumps for water hammer suppression: Enable soft stop, set 8–15 s soft stop time

Soft stop principle: TVR timed voltage ramp-down. It is not variable-frequency deceleration and cannot provide precise constant-speed slowdown; it is only used to suppress water hammer and light-load buffering.

Limitation Reminders

This compact soft starter uses stepped gear adjustment instead of continuous stepless fine-tuning.

Soft stop only activates after a stop command. Once full-speed bypass is closed, the SCRs are bypassed and no longer regulate voltage.

The start timeout protection must be set in coordination; its value must be longer than the actual start time, otherwise Err5 start timeout will trigger.

MCD202-015-T4-CV1 Start / Stop Time Adjustment Precautions

Premisa central: This unit uses TVR timed voltage ramp start/soft stop + bypass incorporado. It is not a VFD. SCRs only work during the start ramp and soft stop ramp. After bypass pull-in at full speed, thyristors are out of circuit.

  1. Start Ramp-Up Time (Ramp Up)
  2. Adjust the current limit knob together with ramp time; do not only adjust the time setting.

The MCD202 operates in current-limit priority mode. Even if ramp time is set to 20 s, a low current limit may prevent the motor from accelerating and trigger Err5 (tiempo de espera de inicio). The ramp only defines the voltage change profile; the current ceiling is locked by the current limit knob.

Field tip: Set current limit first to guarantee rotation, then configure ramp time. For heavy-duty conveyors and compressors, raise current limit before extending start time.

  1. Start timeout protection (Err5) must be longer than the actual acceleration time.

Start timeout range: 2~20 s. Timeout setting actual time to reach full speed, leave a margin of 2–5 s. A 15 s ramp paired with a 10 s timeout will almost certainly trip.

  1. Gear-based adjustment, not continuous stepless regulation

Knob settings are discrete preset steps, not smooth fine adjustment. Fixed range: 2~20 s, predeterminado de fábrica 10 s.

  1. Longer start times extend SCR heating; restrict starts per hour.

Long ramp times combined with high current limits increase thyristor heat generation. For frequent start-stop applications, avoid setting maximum 20 s ramp, otherwise Err1 over-temperature occurs easily. The built-in bypass reduces temperature at full speed, but the SCRs bear load and heat during acceleration.

  1. Differentiate between loaded and light-duty starting

Light-duty fans / bombas centrífugas: 5–10 s is sufficient. Excessively long ramps may cause low-speed stall and sustained high current.

Cintas transportadoras, alimentadores de tornillo, bombas de servicio pesado: Ramp can be extended moderately, paired with higher current limit.

  1. Soft Stop Time (Ramp Down, MCD202 exclusive; unavailable on MCD201)
  2. Soft stop ≠ VFD deceleration; it only reduces voltage gradually.

Constant-speed deceleration cannot be achieved. Torque drops with voltage reduction, and the motor slows by load inertia. For high-inertia fans, even 20 s soft stop may still result in fast coasting; do not expect precise speed control.

  1. Factory default = soft stop disabled. When disabled, the bypass opens and the motor coasts freely.

Soft stop is only enabled for pumps requiring water hammer protection. Soft stop is unnecessary for most fan applications.

Critical point: The bypass contact only opens after soft stop completes and voltage falls to a low level. SCRs remain active and generate heat throughout the soft stop sequence.

  1. Do not use long soft-stop times for low-inertia loads

Pequeños transportadores, valve actuators and similar low-inertia loads will draw sustained low-voltage high current under long soft-stop settings, leading to motor overload Err2 or soft starter overheat Err1.

  1. Emergency stop overrides soft stop logic

External emergency stop cuts the circuit directly and skips the soft stop ramp. Soft stop only responds to normal stop commands.

  1. Error común: Bypass Operation Logic

Start sequence: Start command → SCR voltage ramp → full voltage reached → built-in bypass relay closes, SCRs exit operation. The configured start time only applies before bypass closure.

Stop sequence: Stop command → bypass contact opens first, switching back to SCR control before soft stop ramp begins. If bypass contacts are welded or poorly contacting, soft stop fails immediately and faults occur.

Síntoma: Soft stop configured but motor cuts off instantly when stopping. Prioritize inspecting the bypass contactor.

  1. Momento & Start-Stop Interval

A fixed 2 s interlock delay is built between successive starts to dissipate motor back EMF. Do not program extremely short start-stop pulses in PLC, repeated rapid cycling will trigger main-circuit faults.

Do not send a new start command while the motor is still coasting down. The MCD202 does not support flying start and will see severe inrush current.

  1. Coordination with Motor Protection (CV1 variant has built-in motor protection)

Protección contra sobrecarga del motor (Clase 10) accumulates thermal capacity based on operating current:

Long start ramps with sustained low-speed high current build thermal load and may trip Err2 overload during acceleration.

The motor rated current knob must match the motor nameplate rating, otherwise all protection thresholds are invalid.

  1. Control Supply Variant Note (Your unit CV1: 24 VCA/CC)

Start-stop logic is unaffected by the CV1 supply. Sin embargo: Loss of the 24 V control supply disables soft stop, and the motor shuts down directly without ramp.

  1. Recommended Field Commissioning Sequence
  2. Set motor rated current to match the motor nameplate
  3. Set current limit to guarantee successful loaded start
  4. Configure start ramp-up time
  5. Set start timeout = ramp time + margen de seguridad
  6. Enable soft stop only for water hammer control; set to soft-stop off for other loads
  7. Test start-stop under no load, observe indicator timing and monitor for Err1/Err2/Err4/Err5
  8. Fault Mapping

Err5 Start timeout: Current limit too low OR ramp too long OR timeout threshold set too small

Err1 Over-temperature: Ciclismo frecuente, excessively long start/stop ramps, continuous SCR heating

Err2 Motor overload: Long duration of low-speed high current causing thermal accumulation

danfoss Soft Starter Full Model List & Material Order Codes (Mainstream 400V for China market, T4 = 200–440 VAC)

Model coding rules for MCD201 / MCD202

CV1: 24 V AC/DC control supply (Your MCD202-015-T4-CV1 is CV1)

CV3: 110–240 VCA / 380–440 VAC control supply (most widely ordered)

T4 = 200–440 V; T6 = 200–575 V

MCD201: Voltage ramp start only, no built-in motor overload protection, no soft stop

MCD202: Current-limited start + TVR soft stop + complete motor protection (series you are using)

Estado: MCD200 (MCD201/MCD202) is phased out. New projects select MCD600.

  1. MCD202 (With protection + parada suave, including your model)
Power @400VCorriente nominalModelo completoMaterial Order No.
7.5 kilovatios18 AMCD202-007-T4-CV1175G5210
7.5 kilovatios18 AMCD202-007-T4-CV3175G5211
11 kilovatios24 AMCD202-011-T4-CV1175G5212
11 kilovatios24 AMCD202-011-T4-CV3175G5213
15 kilovatios34 AMCD202-015-T4-CV1175G5221 (your part)
15 kilovatios34 AMCD202-015-T4-CV3175G5222
18.5 kilovatios39 AMCD202-018-T4-CV1175G5224
18.5 kilovatios39 AMCD202-018-T4-CV3175G5225
22 kilovatios48 AMCD202-022-T4-CV1175G5227
22 kilovatios48 AMCD202-022-T4-CV3175G5228
30 kilovatios60 AMCD202-030-T4-CV1175G5230
30 kilovatios60 AMCD202-030-T4-CV3175G5231
37 kilovatios75 AMCD202-037-T4-CV1175G5233
37 kilovatios75 AMCD202-037-T4-CV3175G5234
45 kilovatios88 AMCD202-045-T4-CV1175G5236
45 kilovatios88 AMCD202-045-T4-CV3175G5237
55 kilovatios105 AMCD202-055-T4-CV1175G5239
55 kilovatios105 AMCD202-055-T4-CV3175G5240
75 kilovatios140 AMCD202-075-T4-CV1175G5214
75 kilovatios140 AMCD202-075-T4-CV3175G5215
90 kilovatios170 AMCD202-090-T4-CV1175G5217
90 kilovatios170 AMCD202-090-T4-CV3175G5218
110 kilovatios200 AMCD202-110-T4-CV1175G5220
110 kilovatios200 AMCD202-110-T4-CV3175G5242

7.5~30 kW: Montaje en carril DIN; 37 kW y más: base mount only

  1. MCD201 (Versión económica, no built-in motor protection, no soft stop)
FuerzaActualModelo completoNúmero de material.
7.5 kilovatios18 AMCD201-007-T4-CV3175G5165
15 kilovatios34 AMCD201-015-T4-CV3175G5166
18.5 kilovatios39 AMCD201-018-T4-CV3175G5167
22 kilovatios48 AMCD201-022-T4-CV3175G5168
30 kilovatios60 AMCD201-030-T4-CV3175G5170
37 kilovatios75 AMCD201-037-T4-CV3175G5171
45 kilovatios88 AMCD201-045-T4-CV3175G5172
55 kilovatios105 AMCD201-055-T4-CV3175G5173
75 kilovatios140 AMCD201-075-T4-CV3175G5174
90 kilovatios170 AMCD201-090-T4-CV3175G5175
110 kilovatios200 AMCD201-110-T4-CV3175G5176
  1. MCD100 (Micro economy range, 1.5~11 kW, no built-in bypass)

For small fans and pumps, tamaño compacto, no internal bypass

MCD100-001 (1.5 kilovatios / 3 A) 175G4001

MCD100-007 (7.5 kilovatios / 15 A) 175G4005

MCD100-011 (11 kilovatios / 25 A) 175G4009

  1. MCD600 (New generation flagship, direct replacement for MCD202, graphical menu, funciones mejoradas)

Sample code: MCD600-xxxB-T4-S1X00CV2; material codes start with 132H. Supports flying start, pump cleaning logic, extended protection and communication options. Power range 7.5~1400 kW

Equivalent replacement for your MCD202-015-T4-CV1 (15 kilovatios /34 A): MCD600-0034B-T4-S1X00CV1 (CV1 = 24 Alimentación de control V)

  1. Common MCD200 Series Spare Part Order Codes

MCD200 remote operator panel: 175G9004

Módulo de comunicación Profibus: 175G9040

Modbus RTU module: 175G9041

EtherNet/IP module: 175G9043

Observaciones complementarias

  1. T6 versions (200–575 V) follow the same naming rule; replace T4 with T6, with separate material numbers.
  2. CV1 and CV3 control supplies are not interchangeable, a frequent site mistake.
  3. MCD202 includes built-in bypass; MCD600 can be ordered with or without bypass.
  4. Aviso de fin de vida: MCD201/MCD202 are stock-only. New projects specify MCD600.

Anterior:

Deja una respuesta

Dejar un mensaje