Finder 7S.14.9.024.0220 Forced Guided Contact Safety Relay Module

Finder 7S.14.9.024.0220 Forced Guided Contact Safety Relay Module Model Code Interpretation Segment Code Meaning Series Code 7S Finder 7S series forced guided contact safety relay module, compatible con EN 50205:2002 Type A Contact Configuration 14 4-polo, 2 Normalmente abierto + 2 Normally Closed contacts Mounting & Terminal 9 Montaje en carril DIN, cage-clamp terminal, 22.5mm de ancho ...

  • Detalles del producto

Finder 7S.14.9.024.0220 Forced Guided Contact Safety Relay Module

  1. Interpretación del código modelo
SegmentoCódigoSignificado
Código de serie7SFinder 7S series forced guided contact safety relay module, compatible con EN 50205:2002 Tipo A
Configuración de contacto144-polo, 2 Normalmente abierto + 2 Normally Closed contacts
Montaje & Terminal9Montaje en carril DIN, cage-clamp terminal, 22.5mm de ancho
Voltaje de la bobina2424V DC control coil
Versión & Característica220Standard version without extra functions
  1. Core Specification Table
CategoríaParámetroObservaciones
Basic Info
FabricanteFinderFamous Italian relay brand
Tipo de productoForced guided contact safety relay moduleNon-latching type
Número de orden7S.14.9.024.0220 / 7S1490240220Two formats are both applicable
Parámetros eléctricos
Voltaje de la bobina24En DCStandard industrial control voltage
Consumo de energía de la bobina1.2W.Typical value
Contact Arrangement2NO+2NC (4PAG)Forced guided design for synchronous contact operation
Corriente nominal6A @ 250V AC (AC-1)Rated value for different load types
6A @ 30V DC (DC-1)
3A @ 230V AC (AC-15)
Material de contactoAgNi Silver Nickel AlloyHigh conductivity and wear resistance
Mecánico & Parámetros ambientales
Tipo de instalaciónCarril DIN (EN 60715)22.5mm compact width
Tipo de terminalCage-clampScrewless wiring, fácil instalación
Grado de protecciónIP20Finger-proof, suitable for cabinet interior
Temperatura de funcionamiento-40°C ~ +70°CWide temperature range for industrial use
Temperatura de almacenamiento-40°C ~ +85°C
Proceso de dar un títuloEN 50205:2002 Tipo A, EN 13849-1International safety relay standards
Vida útilMecánico: 10⁷ operations
Eléctrico: 10⁵ operations at rated load
  1. Referencia de reemplazo entre marcas
MarcaModeloSimilaritiesDiferencias
ChampiñónPNOZ X2.8P 24VDC2NO+2NC, 24VCC, forced guided contactProfessional safety relay, higher price and richer functions
siemens3TK2825-1BB402NO+2NC, 24VCC, DIN rail mountBetter compatibility in industrial automation
SchneiderZelio SR2B121BD2NO+2NC, 24VCC, forced guided contactDifferent terminal design, rentable
OmrónG9SA-321-T0752NO+2NC, 24VCC, safety certifiedTamaño compacto, ideal for limited space
  1. 7S Series Main Model List
ModeloContact LayoutVoltaje de la bobinaTipo de terminalSpecial Feature
7S.12.9.024.02202PAG (1NO+1NC)24En DCCage-clampEstándar
7S.14.9.024.02204PAG (2NO+2NC)24En DCCage-clampEstándar (este producto)
7S.16.9.024.02206PAG (3NO+3NC)24En DCCage-clampEstándar
7S.14.9.230.02204PAG (2NO+2NC)230V yCage-clampEstándar
7S.14.9.024.42204PAG (2NO+2NC)24En DCCage-clampLED status indicator
7S.14.9.024.52204PAG (2NO+2NC)24En DCTerminal de tornilloEstándar
7S.34.9.024.02204PAG (2NO+2NC)24En DCCage-clamp10Una corriente nominal
  1. Solución de problemas & Maintenance Guide

5.1 Common Fault Analysis

Fenómeno de fallaPosibles causasPasos de inspección
Coil fails to pull in1. Insufficient or reversed coil voltage1. Measure coil voltage to confirm 24V DC
2. bobina quemada2. Test coil resistance (normal: approx 480Ω)
3. Cableado suelto3. Check terminal tightness
No contact movement1. Jammed forced guided mechanism1. Check mechanical flexibility after power off
2. Oxidized or burnt contacts2. Inspect contact surface damage
3. Mechanical wear3. Verify contact travel distance
Contacto pegado1. Arc burn caused by overload or short circuit1. Check actual load exceeding rating
2. Contact material fatigue2. Replace relay module
LED indicator off1. Damaged LED1. Check power supply connection
2. Power disconnection2. Replace with identical module for test
3. Internal circuit failure

5.2 Mantenimiento & Replacement Suggestion

  1. Safety Priority: Cut off power and wait at least 5 minutes for capacitor discharge before maintenance.
  2. Estructura modular: On-site repair is not recommended; integral replacement is preferred.
  3. Procedimiento de reemplazo

Record wiring positions by photos or sketches

Remove old module from DIN rail

Install new module and reconnect wires accordingly

Power on and verify normal operation

  1. Preventive Maintenance

Inspect terminal connection every 6 meses

Avoid overload, reservar 30% margen actual

Shorten replacement cycle to 2-3 years under harsh conditions

  1. Escenarios de aplicación & Industry Cases

6.1 Campos aplicables

IndustriaAplicación típicaFunción de seguridad
Machinery ManufacturingEmergency stop circuit, safety door monitoringPrevent accidental startup, protect operators
Línea de producción automáticaCortina de luz de seguridad, two-hand control circuitSecure operating area safety
Elevator & EscalatorDoor lock monitoring, safety loopAvoid unexpected elevator movement
Rail TransitDoor control, braking systemComply with railway safety standards
Maquinaria de embalajeGuardrail monitoring, parada de emergenciaPersonnel injury prevention

6.2 Inadmissible Working Conditions

High vibration environment such as stamping machines, shockproof bracket required

Humid and dusty environment, IP54+ sealed enclosure needed

Ultra-high frequent switching over 10 cycles per minute, solid state relay recommended

High current load over 6A / 250V y, contactor required for capacity expansion

6.3 Consejos de selección & Avoidance Notes

  1. Distinguish forced guided contact from ordinary relay; EN 50205 compliant type mandatory for safety application
  2. Confirmar el voltaje de la bobina, avoid AC and DC confusion; this model is 24V DC
  3. Match load type with corresponding rated current (AC-1/AC-15/DC-1)
  4. Reserve enough installation space for 22.5mm width module
  5. Ensure compliance with EN 13849-1 for industrial safety usage

Application Scenarios of Finder 7S.14.9.024.0220

Equipped with forced guided safety contacts, conforming to EN13849 and EN50205 safety standards, applied for equipment safety loop control.

  1. General Industrial Machinery
  2. Máquinas herramienta: Emergency stop circuit, safety door interlock, tool magazine safety lock
  3. Stamping & forging machines: Guard fence detection, slide safety limit
  4. Máquinas de moldeo por inyección: Mold safety door, manipulator area protection interlock
  5. Línea de producción automática
  6. Conveyor line: Light curtain safety protection, station access judgment
  7. Assembly equipment: Two-hand startup circuit, robot fence access control
  8. Sorting & máquinas de embalaje: Flip cover protection, fault emergency stop interlock
  9. Lifting & Hoisting Equipment
  10. Small lift, cargo elevator door control safety circuit
  11. Crane lifting tool limit protection, power-off safety lock
  12. Light Industry & Special Machinery
  13. Safety stop interlock for printing and textile machinery
  14. Safety door monitoring for wood cutting equipment
  15. Fault power-off protection for fans and water pumps
  16. Transportation & Building Auxiliary
  17. Automatic door and escalator safety detection circuit
  18. Vehicle industrial control, miniature railway equipment safety protection
  19. Control Cabinet Internal Control
  20. System emergency power-off safety loop
  21. High voltage cabinet access control and leakage safety interlock

Unsuitable Environments

Non-sealed cabinet with strong corrosion and heavy dust

Ultra-high frequency switching working condition

Working current exceeding 6A rated load

Anterior: