Mini-MW W2YV Compact Dual-Output Isolator
M-SYSTEM (Japón), Montaje en carril DIN, 4-way galvanic isolation (Aporte / Output1 / Output2 / Fuente de alimentación). Designed for 4~20mA industrial signal isolation, ground loop interference suppression and 1-input 2-output signal distribution.
✅ Model Decoding W2YV-AAA-M
W2YV ①②③ ④
- ① A: Input signal = DC 4~20mA (Input resistance: 250Oh)
- ② A: Producción 1 = DC 4~20mA (Max load ≤750Ω)
- ③ A: Producción 2 = DC 4~20mA (Max load ≤350Ω)
- ④ M: Power supply = AC 85~264V wide-range AC (47~66Hz)
Full definition: 4~20mA input, two independent isolated 4~20mA outputs, AC85-264V powered signal distribution isolator
📋 Especificaciones técnicas básicas
| Artículo | Presupuesto |
| Isolation Structure | Galvanic isolation between Input / SALIDA1 / OUT2 / Fuente de alimentación |
| Exactitud | ±0.1% FS |
| Deriva de temperatura | ±0.015% /℃ |
| Tiempo de respuesta | ≤0.5s (0~90%) |
| Tensión soportada | 2000V y, 1 minuto (between each isolation barrier) |
| Resistencia de aislamiento | ≥100MΩ @500VDC |
| Cero / Span Adjustment | Front panel independent trimming; separate ZERO/SPAN adjustment for two outputs |
| Montaje | Carril DIN, dense side-by-side installation for high-density cabinet layout |
| Dimensiones generales | W29.5 × H88.5 × D124 mm |
| Terminales | tornillo m3, par de apriete 0.8 Nuevo Méjico |
| Entorno operativo | -5 ~ +55 ℃, 30~90% HR (sin condensación) |
| Consumo de energía | Aprox.. 4VA @AC100V; Aprox.. 6VA @AC240V |
| Peso | Aprox.. 200gramo |
🎯 Aplicaciones típicas
- Eliminate ground loop interference between SOCIEDAD ANÓNIMA y transmitters
- Distribute one 4~20mA measurement signal to PLC + recorder / indicator (1-input 2-output signal splitting)
- Provide galvanic isolation between field transmitters and control room systems to protect AI modules
- Impedance conversion for parallel acquisition by multiple receiving instruments
⚙️ Selection & Información de reemplazo
Same series DC powered variant: W2YV-AAA-R2 (DC11~27V supply)
Alternativas domésticas: Yutong, Chenzhu, Wanxun and other 1-in-2-out 4-20mA isolators (compare isolation rating, accuracy and temperature drift)
Nota: The two current outputs have different maximum load limits. OUT2 max load is only 350Ω. Use OUT1 for high-load applications.
📌 Troubleshooting Guide
- Inaccurate output: Recalibrate ZERO/SPAN on front panel; check 250Ω matching resistor on input loop
- Sin señal de salida: Verify AC supply 85~264V; check tightness of M3 terminal screws
- Deriva de señal: Check earthing; ensure input side ground is separated from PLC ground. The isolator is used to break common ground.
- Excessive voltage drop under load: Connect the load to OUT1 channel (OUT1 has higher load capacity)
W2YV (Mini-MW Dual-Output Signal Conditioner) Complete Model Code + Common Model List
W2YV = W2YV-①②③-④⑤
①: Input signal; ②: OUT1 output; ③: OUT2 output; ④: Fuente de alimentación; ⑤: Sufijo opcional
Code Definition
① Input Code
A: DC 4~20mA, input resistance 250Ω
6: DC 1~5V, input impedance ≥1MΩ
② OUT1 (Canal 1, higher load capacity: Max 750Ω)
A: DC 4~20mA
6: DC 1~5V
③ OUT2 (Canal 2; Max 350Ω for current output; ≥5kΩ for voltage output)
A: DC 4~20mA
6: DC 1~5V
Y: Sin salida (single-output mode)
④ Power Code
METRO: AC85~264V (Wide AC)
R2: DC11~27V (24Alimentación VCC)
⑤ Options (Suffix /Q, multiple options can be combined)
C01: Silicone coating (humedad & dust protection)
C02: Polyurethane coating
C03: Rubber coating
V01: Multi-turn trim potentiometer
S01: Stainless steel terminal screws
✅ Common Available Models of W2YV Series
- W2YV-AAA-M: 4~20mA input, dual 4~20mA outputs, AC85~264V (tu modelo objetivo)
- W2YV-AAA-R2: 4~20mA input, dual 4~20mA outputs, DC11~27V
- W2YV-6AA-M: 1~5V input, dual 4~20mA outputs, Suministro de CA
- W2YV-6AA-R2: 1~5V input, dual 4~20mA outputs, DC supply
- W2YV-A6A-M: 4~20mA input, OUT1=1~5V, OUT2=4~20mA, Suministro de CA
- W2YV-AA6-M: 4~20mA input, OUT1=4~20mA, OUT2=1~5V, Suministro de CA
- W2YV-6A6-M: 1~5V input, OUT1=4~20mA, OUT2=1~5V, Suministro de CA
- W2YV-A66-R2: 4~20mA input, dual 1~5V voltage outputs, DC supply
- W2YV-AAY-M: 4~20mA input, OUT1=4~20mA only, OUT2 no output (salida única)
- W2YV-666-R2: 1~5V input, dual 1~5V voltage outputs, DC supply
📌 Other W2 Family Models (Same DIN rail housing as W2 series)
W2XF: Arithmetic signal conditioner (addition / subtraction calculation)
W2VABS: Absolute value signal converter
W2RS: RTD resistance temperature detector isolator
W2YV is only for DC mA/V signal 1-in-2-out isolation and distribution. For temperature measurement or arithmetic functions, select other W2 series models above.
⚠️ Important Selection Notes
- Salida mixta (one current + one voltage): Place current signal on OUT1. OUT1 has higher load capacity (750Ω vs 350Ω of OUT2)
- Coated versions C01 are recommended for high-humidity and chemical cabinet environments
- Side-by-side dense DIN installation; no heat dissipation gap required, which is the key advantage of this series
W2YV‑AAA‑M (M-SYSTEM) Dimensiones generales
Ancho(W.) × Height(h) × Depth(D) = 29.5 milímetros × 88.5 milímetros × 124 milímetros
Inch: 1.16″ × 3.48″ × 4.88″
Supplementary Dimension Information
- Montaje en carril DIN: 35carril DIN estándar mm. Modules can be closely mounted side by side, no heat dissipation gap required between modules, ideal for high-density cabinet arrangement
- Peso: Aprox.. 200gramo
- Método de montaje: DIN rail clip mounting, or base plate screw fixing (2×Φ4.2 mounting holes)
- Terminales: Terminales de tornillo M3. The terminal block protrudes forward; above dimensions refer to maximum overall outline of the unit.
W2YV‑AAA‑M Input Signal Description
For model W2YV-AAA-M specifically: Input is fixed as DC 4~20mA (1st character A), input resistance 250Ω
All Optional Input Types of W2YV Series (1st character in model code)
- A: DC 4~20mA (Current Input)
Input resistance: 250Oh
This is the input specification of your W2YV-AAA-M
- 6: DC 1~5V (Voltage Input)
Input impedance ≥1MΩ, high-impedance voltage acquisition
⚠️ Importante: W2YV series only has these two factory fixed input ranges. It is NOT programmable. It cannot be modified on-site for 0-10V, 0-20mamá, thermocouple or RTD signals. If temperature measurement or multi-range programmable function is required, select other W2 series models such as W2XF.
Brief Comparison
| Código | Tipo de señal | Impedancia de entrada |
| A | DC 4~20mA | 250Oh |
| 6 | DC 1~5V | ≥1MΩ |
Suplemento
The input range of W2YV is locked at factory by model coding. It cannot be changed by hardware jumpers on site. Only A (4~20mA) o 6 (1~5V) can be selected during ordering.
contactor,cortacircuitos,sensor,Codificador,SOCIEDAD ANÓNIMA,Convertidor



















NH42-63-318x560.png)