Estado: Interrumpido. Order acceptance stopped in 2016; factory repair support ended in Oct 2023.
✅ Definición del código del modelo
GT11: GT11 series, entry-level economical GOT
55: 5.7-inch display
q: Q-Bus interface (direct connection to mitsubishi Q-series SOCIEDAD ANÓNIMA bus)
S: Equipped with RS232 + RS422 serial ports
BD: Fuente de alimentación CC24V
📌 Especificaciones principales de hardware
Mostrar: 5.7-inch STN color LCD, 320×240 (QVGA), 256 bandera
Iluminar desde el fondo: CCFL cold cathode lamp (non-replaceable separately; vida útil aprox.. 75,000h @ 25℃)
Pantalla táctil: Matrix resistive touch, supports two-point simultaneous touch
Fuente de alimentación: CC 24 V (20.4~26,4V), typical power consumption 4.32W / 180mamá
Onboard memory: 3MB Flash (project storage), 512KB SRAM (alarmas / recetas)
Real-time clock: Maintained by lithium battery GT11-50BAT for clock and SRAM data
Interfaces:
RS422 (D-Sub9 female, communication with Mitsubishi PLC programming port)
RS232 (D-Sub9 male, for barcode scanners, PC project download)
USB Device (Mini-B, project upload/download, transparent transmission)
Ranura para tarjeta CF (legacy CF card, not SD card)
Maximum screen count: 4096 screens
📡 Communication Capabilities
- Q-Bus direct connection to Mitsubishi Q-series PLC (core feature of this model)
- Serial RS422/RS232: Compatible with FX, q, L series; also supports Modbus RTU, Omrón, Delta and other third-party PLCs
- USB transparent transmission, PC can directly pass through to access downstream PLC
Nota: Sin puerto Ethernet incorporado; direct Ethernet communication is not supported.
🛠️ Programming Software
GT Works2 / GT Obras3 (compatible; select GT1155-QSBD when creating new projects)
Subir & download methods: Cable USB, RS232, tarjeta CF
🔁 Opciones de reemplazo (Factory Recommended)
GT2505-VTBD (Privilegiado)
5.7-pulgada, 65536-color TFT, analog resistive touch (two-point touch is no longer supported)
Panel cutout is largely compatible, but housing is 1.5~2mm larger on top and bottom; cabinet cutout verification required; CF card replaced by SD card
Puerto Ethernet incorporado, mayor rendimiento; projects can be converted and migrated via GT Works3, minor scripts and special functions require modification
Alternativa: GT2705-VTBD (especificación más alta)
⚠️ Common Faults & Puntos de solución de problemas
- Dim backlight / black screen with responsive touch: CCFL backlight aging, the most frequent failure. No original factory backlight spare parts available; most repairs involve retrofitting LED backlights.
- Fallo de comunicación: Verify baud rate and station number; do not mix Q-Bus mode and serial mode; avoid reversed A/B wiring for RS422.
- Pérdida de tiempo / recipe reset: Built-in lithium battery GT11-50BAT depleted; replace battery directly.
- CF card not recognized: Only standard legacy CF cards are supported. High-speed CF cards and CF-to-SD adapters are often unstable.
- Touch drift / local touch failure: Wear of matrix resistive film; replace touch panel.
📏 Installation & Calificación ambiental
Montaje: Embedded panel mount with snap fasteners
Entorno operativo: 0~50 ℃, IP65 on front face (with installed sealing gasket), IP20 on rear side
- Separar & Dimensiones generales (GT1155-QSBD)
Unidad: milímetros, standard landscape installation
Recorte del panel: 153 (W.) × 121 (h), tolerance +0~+1mm, cabinet plate thickness recommended 1.6~5mm
Dimensión general: 164 (W.) × 135 (h) × 55 (D)
Espacio libre de instalación: Reserve ≥10mm space top and bottom for snap disassembly; install factory gasket in sealing groove to maintain front IP65 rating
⚠️ GT2505-VTBD cutout: 156 × 124, 3mm wider and taller than the original. Original cutout will be undersized. On-site solutions:
- Enlarge cutout (privilegiado); 2. Install adapter flange plate; 3. Switch to GT2705-VTBD (cutout fully compatible with original 153×121)
- Q-Bus Wiring for Direct Q-CPU Connection
The Q-Bus of GT1155-QSBD is not a DB9 serial port. It is an onboard dedicated Q-Bus interface, using GT01-C30R2-6P flat bus cable plugged directly into the front bus port of Q-CPU. It cannot be made with ordinary RS422 cables.
Communication mode setting: Select Q CPU (Direct Bus Connection) in the GOT connection target, not RS422
Important restrictions:
Q-Bus only supports Q-series CPU (Q00/Q01/Q02/Q03UD/Q04UDH, etc.), not L/R/FX series
Bus channel and rear DB9 RS422 serial port are independent; do not use both simultaneously
Max cable length: 3metro; no station number required for bus communication, direct CPU access
Matching cable part numbers: GT01-C10R2-6P (1metro) / GT01-C30R2-6P (3metro)
【Alternative serial connection to Q PLC】Using DB9 RS422, seleccionar “Q CPU Serial Connection”. Standard Mitsubishi RS422 DB9 pin definition:
Shield single-ended grounding only at PLC side; grounding at both ends causes circulating interference current.
- Full Migration Checklist: GT11 Project → GT2505-VTBD (GT Obras3)
Requisito previo: GT Works3 V1.115 or newer. Older versions have many conversion bugs for legacy GT11 projects.
Paso 1: Backup Original Project
- Open GT1155-QSBD project in GT Works2 / GT Obras3
- Save a separate original copy (.G11). Do not convert directly on the original file.
- Upload project from HMI first (tarjeta CF / USB) to avoid inconsistency between source file and program inside HMI.
Paso 2: Model Conversion
- Menú: Project → Change Model
- Source model: GT1155-QSBD; modelo objetivo: GT2505-VTBD
- Conversion options: Check screen conversion, comments, alarmas, recetas; uncheck legacy GT11 exclusive OS functions
Critical resolution note: GT11=320×240; GT2505=640×480. Screens scale 2× automatically, component positions shift. Every screen must be adjusted manually!
Paso 3: Communication Verification (Critical for Q-Bus Version)
✅ Major risk: GT25 series has NO onboard Q-Bus interface!!
This is the biggest pitfall for GT1155-QSBD replacement. The native Q-Bus direct link is removed on GT25. Two retrofit options:
Opción A (Recomendado): Add QJ71E71-100 Ethernet module to Q PLC, GT25 communicates via SLMP over Ethernet TCP
Opción B: Abandon bus, use RS422 serial to connect Q CPU programming port, set connection target to 【Q CPU Serial】 and replace with RS422 cable
❗ Original GT01-C30R2-6P flat bus cable CANNOT be reused; the hardware interface no longer exists.
Paso 4: Functional Inspection Checklist
Screens: Botones, lámparas, numeric input, bar graphs, text; fix overflow and overlapping elements after scaling
Scripts / Macros: Legacy GT11 C scripts and bitwise functions may be incompatible; rewrite scripts with errors
Alarm records: Verify alarm trigger conditions, pop-up windows and alarm reset logic
Recipes: Migrate GT11 SRAM recipes to GT25 Flash / SD storage; check D register offset addresses
Real-time clock: GT11 uses GT11-50BAT; GT2000 uses different battery model
Transparent transmission: Reconfigure USB transparent and serial transparent channels for GT25
CF card functions: Legacy CF on GT11 replaced by SD on GT25; modify file paths for log/recipe export in scripts
Third-party communication (Modbus etc.): Velocidad de baudios, parity and station numbers are generally compatible, frame timing requires testing
Paso 5: Descargar & Power-On Test Procedure
- Después de la conversión, compile and resolve all errors and warnings before download
- Download to GT25; do not hot-swap on site directly. Test communication on bench first.
- Register verification: Randomly read/write X/Y/M/D registers and cross-check with PLC online monitor
- Touch test: GT11 supports two-point touch, GT25 analog resistive is single-point only. Any logic relying on simultaneous dual-touch must be modified
- Verify backlight, buzzer and screen switching speed
- Piezas de repuesto & Consumables List
Batería: GT11-50BAT (original for GT1155-QSBD, 3V lithium, clock and SRAM recipe backup)
Sealing gasket: GT1155-QSBD dedicated gasket; front IP65 rating fails once aged
tarjeta CF: Only standard legacy CF (≤2GB). High-speed CF and CF-to-SD adapters have poor compatibility
Communication cables: GT01-C10R2-6P / GT01-C30R2-6P (Q-Bus flat cable)
- Supplementary Quick Troubleshooting for Q-Bus
- Communication error alarm: Confirm connection target set to 【Q Bus】 not RS422; bent pins and loose plugs on flat cable are common faults
- Bus connected but register read failure: Verify accessible soft element range of Q-CPU; some special registers are restricted under bus mode
- Intermittent disconnection: Flat cable damage from repeated bending; separate bus cable from power cables and add ferrite core.
GT1155-QSBD Replacement & Engineering Change Implementation Plan
Core constraint: Q-Bus is exclusive to the old model. GT25/GT27 have no such hardware interface. Communication architecture modification is mandatory; it is not a simple panel swap and program download.
Two replacement routes:
Route A: GT2505-VTBD (rentable, cutout mismatch, SLMP Ethernet / RS422 serial)
Route B: GT2705-VTBD (original 153×121 cutout compatible, less cabinet modification, Ethernet)
7 work modules: ECN Engineering Change Notice, BOM Update, Electrical Drawing Update, HMI Project Migration & Update, PLC Side Modification, Operation Document Update, On-Site Validation & File Archiving
- ECN Engineering Change Notice (Formal Approval Document for Purchasing / Producción / Aftersales / Customer)
Required contents in ECN:
- Change reason: GT1155-QSBD discontinued, factory spare part supply terminated
- Old part: GT1155-QSBD; New part: GT2505-VTBD / GT2705-VTBD
- Communication change (llave):
Original: Q-Bus flat cable GT01-CxxR2-6P direct to Q-CPU
New two options:
✅ Opción 1 (Privilegiado): Add QJ71E71-100 Ethernet module to Q PLC, HMI SLMP over Ethernet TCP
✅ Option2: Remove bus, use RS422 serial to PLC programming port
- Scope of impact: lista de materiales, electrical schematic, cabinet cutout, alambrado, HMI project, PLC network parameters, spare part list, operation manual
- Rollout timing: New orders fully switch over; field replacement for breakdown maintenance on demand
- Risk items: Screen scaling offset, dual-touch logic invalid, CF changed to SD, dedicated bus cable obsolete
- Approval signature: Eléctrico, software, proceso, adquisitivo, customer (if end-user equipment)
Attachments: Comparison table, communication topology drawing, cutout comparison, informe de prueba
- BOM Update
- Remove items: GT1155-QSBD, GT01-C10R2/30R2-6P Q-Bus flat cable, GT11-50BAT battery, GT11 dedicated gasket, legacy CF card
- Add items (per selected scheme):
HMI unit: GT2505-VTBD or GT2705-VTBD
Ethernet scheme: QJ71E71-100, Cat5e cable, RJ45 connector, cambiar (if needed)
Serial scheme: Mitsubishi RS422 communication cable (D-Sub9)
Consumables: GT2000 series gasket, industrial SD card, GT2000 battery
- BOM remark: Replaces GT1155-QSBD, communication changed from Q-Bus to SLMP Ethernet / RS422, see drawing for cutout difference
- Slow-moving material control: Mark legacy bus cable and GT11 battery separately, no longer bundled for new machines
- Electrical Drawing Update (CAD / EPLAN)
1) Schematic
Delete Q-Bus interface and bus cable loop
Agregar:
Ethernet scheme: QJ71E71-100 power supply, network wiring, IP allocation table
Serial scheme: HMI RS422 DB9 wiring (A/B/SG)
Power circuit remains DC24V generally; verify power rating and add remark on drawing
Add network topology drawing: IP table for PLC, HMI, SCADA, cambiar (SLMP requires unified IP & station planning)
2) Cabinet Cutout & Panel Machining Drawing
Route A (GT2505-VTBD): Original 153×121 → New 156×124
Drawing note: Enlarge cutout by 3mm or use adapter flange
Route B (GT2705-VTBD): 153×121 compatible, only update model marking
Front panel nameplate: Update model
3) Terminal Diagram & Cabinet Layout Drawing
Remove original bus connector location; update routing for network / serial cable; mark shield grounding specification
- HMI Project Migration & Version Update (Core Work)
Recommended software: GT Works3 V1.115 or newer
- Source archive: Separate backup of original .G11 project + HMI upload backup (tarjeta CF). Keep legacy archive, do not overwrite.
- Model conversion: Project → Change Model, GT1155-QSBD → GT2505/GT2705-VTBD
- Screen adjustment (320×240 →640×480 auto 2× zoom):
Correct overflow, overlapping text, trend and alarm window on each screen
Crítico: Dual simultaneous touch function no longer works. If interlock logic relies on dual press, migrate logic to PLC or rewrite HMI script
- Reconfigure communication target (major risk point)
Delete old 【Q CPU (Direct Bus Connection)】
Ethernet SLMP: New connection target → QCPU (Ethernet SLMP), fill IP, network No., station No.
Serial scheme: New 【Q CPU Serial Connection】, match baud rate and parity with PLC
- Functional revision
CF export for logs/recipes: Change all file paths to SD in scripts
Legacy GT11 macros / C scripts: Rewrite incompatible functions and test
Recipe: SRAM recipe migrated to Flash / DAKOTA DEL SUR, verify D register offset
Alarma / history log: Export medium changed from CF to SD
Transparent transmission: Reconfigure USB and serial transparent channels
- Compilar, clear warnings, generate new .G2S project, upgrade version number (Vx.x, remark: GT1155-QSBD replacement)
- Download test: Bench communication test first, then online with PLC, spot check M/D register read/write consistency
- PLC Program & Parameter Update (Q Series)
- Ethernet scheme (QJ71E71-100):
Configure Ethernet module parameters in GX Works2: IP, subnet mask, station No., enable SLMP service
Enable MELSOFT connection, allow GOT access to soft elements
Verify access permission for special registers and latch memory
- Serial scheme: Match PLC programming port serial parameters, avoid conflict with other SCADA
- PLC ladder logic usually unchanged, unless dual-touch interlock logic exists on HMI; move such logic into PLC
- Upgrade PLC project version, add change log note: Adapted for HMI replacement
- Manual de operación, Maintenance Document & Aftersales Material Update
- Operation manual:
Update HMI model, download method (USB/SD/Ethernet; remove CF and Q-Bus chapters)
Add IP table and SLMP communication troubleshooting section
Delete two-point touch operation description
- Mantenimiento & fault manual:
Remove GT01 bus cable troubleshooting and CCFL backlight content
Add new items: Ethernet offline, SLMP communication error, SD log export, GT2000 battery replacement
- Spare part manual: Replace all part numbers, remove discontinued SKUs
- Validación, Prueba & Document Archiving (Closed-Loop Control)
Test Checklist
Encendido, iluminar desde el fondo, buzzer and touch function for all screens
Communication stability: Continuous run ≥2h, no packet loss or cyclic disconnection
Botón, lamp, numeric value, bar graph and trend operation
Alarm trigger, reset and history log storage (DAKOTA DEL SUR)
Recipe read/write and power-off retention
RTC retention and battery drop-out test
Screen switching speed comparison
EMC interference test under same cabinet environment with power cables
Archive Package (Complete Change File Set)
- ECN notice + approval sheet
- Viejo & new BOM comparison
- Updated electrical drawing (PDF + source)
- Legacy GT11 project backup + new GOT2000 project
- PLC program and parameter backup
- Validation test report
- Revised operation & maintenance manual
Suplemento: Field Breakdown Replacement (Not for New Production Units)
For on-site repair replacement of failed old panels, not new machine BOM:
- Evaluate if customer accepts cutout enlargement / flange adapter and Ethernet module addition
- If modification scope is restricted: Adopt RS422 serial scheme without adding QJ71E71, minimal modification with slower communication speed
- Issue field change form, commissioning record and version remark separately for site retrofit log.
- Full GT11 Series Model List (GT115□ 5.7 pulgada, All Discontinued)
1) Standard Panel Mount (GT1155 / GT1150)
① GT1155 (Color 256-color, 320×240 QVGA)
STN Type (Same series as QSBD)
- GT1155-QSBD (Estándar, Q-Bus, flagship model)
- GT1155-QSBDQ (Q-Bus, early CF hardware version)
- GT1155-QSBDA (A-Bus version for A-series legacy PLC)
TFT High-Bright Color
- GT1155-QTBD (color, Q-Bus)
- GT1155-QTBDQ (Q-Bus + early CF interface)
- GT1155-QTBDA (A-Bus version)
② GT1150 (Monochrome 16-level grayscale STN)
- GT1150-QLBD (Q-Bus monochrome)
- GT1150-QLBDQ (Q-Bus + early CF interface)
- GT1150-QLBDA (A-Bus version)
2) Handy Portable GOT
- GT1155HS-QSBD (Handheld STN color, Q-Bus, same hardware as GT1155-QSBD)
- GT1150HS-QLBD (Handheld grayscale, Q-Bus)
3) China-Specific Suffix (-do, No Built-In Battery)
GT1155-QSBD-C
GT1155-QTBD-C
GT1150-QLBD-C
- Suffix Definition
- q: Built-in Q-Bus interface for direct Q-CPU connection (key feature of this model)
- SBD: STN color LCD (GT1155-QSBD)
- TBD: LCD TFT en color (higher brightness)
- LBD: Monochrome grayscale screen (GT1150 series)
- Trailing Q: Early CF hardware revision
- Trailing A: A-Bus for legacy A-series PLC
- SA: Handy handheld GOT
- GT11 Series Accessory List
1) Q-Bus Communication Cables
GT01-C10R2-6P (1metro)
GT01-C30R2-6P (3metro, commonly used on site)
2) Consumables & Guardado
Batería: GT11-50BAT (3V lithium, RTC and SRAM recipe backup, compatible across series)
Memory card: Legacy standard CF only (max 2GB; CF-to-SD adapters unstable)
Sealing gasket: GT1155 dedicated gasket for front IP65
3) Option Boards
GT11-50FNB: CF card expansion board
GT11-70PSCB: Printer interface board
- Replacement Mapping (GT11 → GT2000)
| Modelo antiguo | Preferred Replacement | Compatible con recortes. | Retrofit Communication Note |
| GT1155-QSBD | GT2705-VTBD | ✅ 153×121 exact match | Q-Bus removed, switch to SLMP Ethernet |
| GT1155-QSBD | GT2505-VTBD | ❌ Cutout enlarge to 156×124 | Ethernet SLMP or RS422 serial |
| GT1150-QLBD | GT2505-VTBD | ❌ Cutout enlargement required | RS422 serial communication |
- Discontinuation Note (For BOM Remark)
Production discontinued: Oct 2016
Repair support terminated: Oct 2023, no new original factory stock available
contactor,cortacircuitos,sensor,Codificador,SOCIEDAD ANÓNIMA,Convertidor



















NH42-63-318x560.png)