OMRON CVM1-PA208 PLC Power Supply Module - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

 OMRON CVM1-PA208 PLC Power Supply Module - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

eléctrico/

OMRON CVM1-PA208 PLC Power Supply Module

CVM1-PA208 is a standard dual-output power supply module for OMRON SYSMAC CVM1 series PLCs. It provides DC5V 8A for PLC core power supply and DC24V 2A for I/O module power supply, suitable for medium and large-scale PLC control systems. Below is the complete technical data in standard structure. Model Code Definition Model Segment Meaning Detailed ...

  • Detalles del producto

CVM1-PA208 is a standard dual-output power supply module for OMRON SYSMAC CVM1 series SOCIEDAD ANÓNIMAs. It provides DC5V 8A for PLC core power supply and DC24V 2A for I/O module power supply, suitable for medium and large-scale PLC control systems. Below is the complete technical data in standard structure.

  1. Definición del código del modelo
Segmento de modeloSignificadoDescripción detallada
CVM1Código de serieSYSMAC CVM1 PLC series, designed for large-scale machine control
PAGTipo de productoPower Supply Module, supplies stable DC power to PLC system
ASpecification TypeStandard AC input power module (differentiated from PD series DC input)
208Output SpecificationMain output: DC5V 8A; Auxiliary output: DC24V 2A
Número de pedido.Standard Part NumberCVM1-PA208 (Alternative No.: CVM1PA208)
  1. Parámetros de especificación principales (Authorized Certified Version)
Categoría de parámetroEspecificación detalladaObservaciones & Proceso de dar un título
Información básica
FabricanteOMRON Industrial AutomationBrand confirmation: Not SMC product, dedicated PLC power module
Tipo de productoSwitching Power Supply Module (Montaje en carril DIN)Compliant with EN 60715 standard 35mm DIN rail installation
Potencia nominalAprox.. 200W.High-efficiency switching power design, efficiency>90%
Especificaciones eléctricas
Voltaje de entradaAC100-240V, 50/60Hz (Entrada de amplio voltaje)Global universal, auto-adaptive to voltage & frequency fluctuation
Corriente de entrada3.5A @100V / 1.8A @240VMax input current under full load
Output Channel 1DC5V, 8A (Tolerance ±5%)Main power for PLC CPU and core modules
Output Channel 2CC 24 V, 2A (Tolerance ±10%)Auxiliary power for I/O modules and external sensors
Ripple & Ruido≤100mVp-p (5V), ≤200mVp-p (24V)Full load condition, meets industrial power standards
Protección contra sobrecorrienteBuilt-in electronic protection (auto-recovery)8.8A protection for 5V channel, 2.2A protection for 24V channel
Dimensiones físicas
Tamaño (Ancho×Alto×Profundidad)47mm × 95mm × 250mmEstructura compacta, ahorra espacio en el gabinete
PesoAprox.. 1.2kilosEquipped with DIN rail clip, fácil instalación
Grado de protecciónIP30Dustproof design, suitable for installation inside industrial control cabinets
Environmental Specifications
Temperatura de funcionamiento0℃ ~ 55 ℃Non-condensing, conforms to industrial environmental standards
Temperatura de almacenamiento-20℃ ~ 70 ℃Adaptable to harsh transportation and storage conditions
Humedad relativa10%~90%RHNon-condensing, prevents internal components from moisture damage
Resistencia a las vibraciones10-55Hz, 0.5mm double amplitudeCumple con IEC 60068-2-6
Resistencia a los golpes150m/s² (15GRAMO), 11EMCumple con IEC 60068-2-27
Certificaciones
CECompliant with EMC Directive 89/336/EEC & Low Voltage Directive 73/23/EECcertificado. No.: CE 0120
ULCompliant with UL 508 Estándarcertificado. No.: E174158
CSACompliant with CSA C22.2 No.14 Standardcertificado. No.: LR66168
RoHSCompliant with EU RoHS 2011/65/EULead-free eco-friendly design
Air Freight Compliance
Built-in BatteryNo lithium battery / super capacitor installedCompliant with IATA dangerous goods regulations, non-restricted goods
Shipping ClassGeneral CargoNo special shipping documents required, safe for air/sea/land transportation
  1. Cross-brand Compatibility Comparison Table (PLC Power Modules)
OMRON ModelReplacement BrandModelo alternativoCompatibility DescriptionSugerencia de selección
CVM1-PA208siemensPD 307 5AAporte: AC120/230V compatible; Producción: 5V/5A (lower than original 8A), 24V/2A identicalReduce 5V load or upgrade to PS 307 10A
SchneiderBMXPSD1200Aporte: AC85-264V compatible; Producción:5V/4A insufficient, 24V/2A identicalOnly applicable to small-scale PLC systems
mitsubishiQ61PAporte: AC100-240V compatible; Producción:5V/8A identical, 24V/1.5A insufficientLimit 24V load within 1.5A
rockwell1756-PA72Aporte: AC85-264V compatible; Producción:5V/4A insufficient, 24V/4A surplusAdd extra 5V power module
OMRON AlternativeCJ2M-PA208Fully identical input & output parametersOptimal replacement, preferred for CVM1 series upgrade

Selection Rule: Prioritize same-series models; check output parameters for cross-brand replacement; take 5V as main power and 24V as auxiliary power; match load capacity for stable operation; choose CJ2M series first for system upgrade.

  1. Full Series Model List (CVM1/CVM1D Power Modules)
ModeloOutput SpecificationCaracterísticasÁmbito de aplicaciónOrder Number
CVM1-PA208DC5V 8A, DC24V 2AStandard AC inputStandard PLC system, I/O points ≤6439035963
CVM1-PA209DC5V 9A, DC24V 2AHigh 5V output AC inputLarge PLC system, I/O points ≤8039035964
CVM1-PA212DC5V 12A, DC24V 2AUltra-high 5V output AC inputSuper-large PLC system, I/O points ≤12839035965
CVM1-PD024DC24V 4ASingle 24V DC inputDistributed I/O system only needing 24V power39035966
CVM1-PD040DC24V 10AHigh-current 24V DC inputSystem with massive I/O modules & servo drives39035967
CVM1D-PA208DC5V 8A, DC24V 2ADual redundant system dedicated AC inputCVM1D redundant control system for high reliability demand39035968
  1. Solución de problemas comunes & Maintenance Guide
Fenómeno de fallaPosibles causasSolucionesMaintenance PeriodSpare Parts List
Abnormal 5V output voltage (<4.75V or >5.25V)1. Input voltage out of range1. Check input power 100-240V1-2 horasElectrolytic capacitor, power module
2. Overloaded 5V output2. Reduce load or replace with PA209/PA212
3. Damaged internal switching components3. Replace power module
4. Aging filter capacitors4. Replace 1000μF/16V electrolytic capacitor
No 24V output1. Blown 24V output fuse F21. Replace 2A/250V fast fuse0.5-1 hora2A fuse, terminal block
2. Loose output terminals2. Fasten terminals and inspect wiring
3. Faulty internal rectifier circuit3. Repair or replace module
Indicador de encendido apagado1. No input power connected1. Check power wiring connection0.5 hora5A fuse, interruptor de encendido
2. Damaged power switch2. Replace power switch
3. Blown input fuse F13. Replace 5A/250V fuse
4. Faulty internal power IC4. Replace power module
Module overheating alarm (Temp>60℃)1. Ambient temperature too high1. Lower ambient temp ≤55℃1 hora12V cooling fan, heat sink
2. Poor ventilation2. Mejorar la ventilación & disipación de calor
3. Broken internal cooling fan3. Replace 12V DC cooling fan
4. Excessive output load4. Reduce load or use higher power module
Excessive output ripple (>200mVp-p)1. Aging filter capacitors1. Replace filter capacitors for 5V/24V channel1-2 horasElectrolytic capacitor, buffer resistor
2. Unstable output load2. Add buffer circuit to stabilize load
3. Internal circuit failure3. Repair or replace module

Consejos de mantenimiento: Check input voltage & fuses first, then inspect output load and terminals; keep operating temperature below 55℃; refer to manual for fault codes; replace module preferentially for quick repair.

  1. Entorno de aplicación & Industry Cases

6.1 Recommended Application Scenarios

Automatización Industrial: Main power supply for PLC control systems in automobile manufacturing & electronic production lines

Alimento & Beverage Industry: Power supply for control circuits and sensors of packaging & filling equipment

Logística & almacenamiento: PLC system power supply for stackers in automated stereoscopic warehouses

Tratamiento de agua: Power supply for control equipment and instruments in sewage treatment plants

Metallurgy Industry: Power supply for automatic production line control and monitoring systems in steel plants

Pharmaceutical Industry: PLC control power and clean room environment monitoring power for pharmaceutical production equipment

6.2 Unrecommended Application Scenarios

Outdoor non-protected environment: IP30 rating vulnerable to dust and moisture causing malfunctions

High-temperature environment: Temperature over 55℃ leads to unstable output and shortened service life

Severe vibration environment: Vibration over 15G damages internal capacitors and transformers

Explosive & flammable areas: Diseño no a prueba de explosiones, extra explosion-proof cabinet required

Strong electromagnetic interference sites: EMI filter must be equipped to avoid excessive output ripple

6.3 Casos de aplicación típicos

Caso 1: Auto Parts Production Line

Solicitud: Power supply for CVM1-CPU21-V2 PLC and 16 sets of I/O modules including AD/DA modules

Configuración: CVM1-PA208 + CVM1-CPU21-V2 + 2×CVM1-AD041 + 2×CVM1-DA041

Operation Effect: Stable operation for 5 years with failure rate below 0.1%, supports 24-hour continuous production and strong grid fluctuation resistance

Caso 2: Automated Stereoscopic Warehouse

Solicitud: Power supply for stacker control PLC, controlling 20 servo axes and 50 sensores

Configuración: CVM1-PA208 + CVM1-CPU11 + 2×CVM1-MD261 motion control modules

Operation Effect: Stable output and strong anti-interference performance, adapts to dusty warehouse environment, supports frequent start-stop operation

  1. Key Information Summary (Purchase & Maintenance Essential)
  2. Brand Confirmation: CVM1-PA208 is exclusively OMRON product, not SMC pneumatic component, please distinguish brands clearly.
  3. Función principal: Dual-output power module supplying DC5V 8A and DC24V 2A for CVM1 series PLC systems.
  4. Cumplimiento & Proceso de dar un título: Fully certified with CE, UL, CSA and RoHS; no built-in batteries, fully compliant with air freight rules for global shipment.
  5. Estado del producto: Discontinued official production; CJ2M-PA208 is fully compatible preferred replacement; after-sales maintenance service available until 2028.
  6. Consejos de selección: Select model according to PLC I/O quantity; adopt CVM1-PA209/PA212 when I/O points exceed 64.
  7. Puntos de mantenimiento: Regularly inspect input voltage 100-240V, output load limit (≤8A@5V, ≤2A@24V) and ambient operating temperature.
  8. ADDA AK1782HB
    Delta PFB1224UHEC8X
    Delta FFB0624SHE
    СВВ65 35 мкф на 450в
    CBB65-450В 50 мкФ
    СВВ65 45 мкф на 450в
    CBB61, 4мкФ, 450В, 5%
    CBB61, 3мкФ, 450В, 5%
    CBB61, 2,5мкФ, 450В, 5%
    датчики уровня VNY 4 NS/NT art 481046
    GEFRAN 40T-48-4-00-RR-0-0-0-0
    8 week
    X20DI9371 Rev.GO
    X20 BM11
    Omron DRT1-AD04 24 VCC
    Omron DRT2-OD16ML
    Omron C200HW-PA204
    Omron C200HG-CPU43E
    Omron CJ1W-DRM21
    Omron C200HW-CLK21
    Omron C200H-OD219
    Omron C200H-DA004
    Omron C500-OD218
    Omron C200H-ID217
    Omron DCN1-3T-PORT 95% new
    CVM1-PA208
    CVM1-CLK21
    CV500-ETN01
    CVM1-CPU11-V2
    C500-OD213
    C500-AD501
    Three-Phase Motor Terminal Board
    50ммм х 30мм Y80-90 55*35mm
    Three-Phase Motor Terminal Board
    70х42мм Y100-132 65*38.5mm
    INCOE Hot Runner Heater Coils
    BH24047 315W 230V
    BH16097 230V 300W
    B&R Automation
    3IF060.6
    A-B
    SLC 500 1747-BA -3V
    S15-PA-5-C11-PK
    Encoder BHT 16.24A 1000/403622
    Encoder BHT 16.24A 1500/403622
    Encoder BHT 16.24A 5000/403622
    Преобразователь BTK-2-111-DIN Crs-485на DIN рейку для ICP(EPE)датчиков
    IMI 603C01
    41AC-25103-214-1-A0

Anterior:

Próximo:

Deja una respuesta

Dejar un mensaje