chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

 Omron MY4N-GS-R Miniature Power Relay - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

eléctrico/

Omron MY4N-GS-R Miniature Power Relay

Model PartMeaning
MYBasic series of miniature power relays
44 polos (4 sets of changeover contacts)
norteStandard type (no built-in surge suppression component)
GSNew-generation MY-GS series with a standard mechanical indicator
RWith LED action indicator light
DC24/AC220, etc..Coil voltage specification (p.ej., MY4N-GS-R DC24)

  • Detalles del producto

Omron MY4N-GS-R is a 4-pole standard model of the MY-GS series miniature power relays. Upgraded from the classic MY series general-purpose relays, it comes standard with a mechanical action indicator, featuring high reliability and ease of use, and is widely applied in industrial automation control circuits.

  1. Model Meaning Explanation
Model PartMeaning
MYBasic series of miniature power relays
44 polos (4 sets of changeover contacts)
norteStandard type (no built-in surge suppression component)
GSNew-generation MY-GS series with a standard mechanical indicator
RWith LED action indicator light
DC24/AC220, etc..Coil voltage specification (p.ej., MY4N-GS-R DC24)
  1. Core Specification Parameters
Elemento de parámetroSpecification ValueDescripción
Configuración de contacto4PDT (4 sets of changeover contacts)Each set includes 1 common terminal (COM), 1 normally open terminal (NO), y 1 normally closed terminal (CAROLINA DEL NORTE)
Corriente nominal6A (resistive load)AC-15: 250V 6A; DC-13: 30V 6A
Tensión nominalMax. 250V AC/30V DCSuitable for most industrial control circuits
Voltaje de la bobinaMultiple options availableDC6/12/24/48/110/220V; AC12/24/48/100/110/220/240V
Consumo de energía de la bobinaApproximately 1.2W for DC; Approximately 1.8VA for ACLow-power consumption design to reduce heat generation
Vida mecánica50,000,000 operacionesHigh durability, suitable for frequent cycling
Vida eléctrica500,000 operaciones (at rated load)Reliable switching performance
Operation TimeMax. 15EMFast response, suitable for precision control
Release TimeMax. 10EMFast reset to reduce control delay
Insulation Resistance≥100MΩ (500En DC)High insulation performance to ensure safety
Dielectric Withstand Voltage2,000V AC for 1 minute between coil and contactsCompliant with international safety standards
Temperatura de funcionamiento-55℃~+70℃Adaptable to harsh industrial environments
Tipo de terminal14-pin plug-in typeCompatible with PYF series sockets (PYF-PU Push-In Plus sockets are recommended, which can reduce wiring time by 60%)

III. Product Features and Advantages

  1. Standard Mechanical Action Indicator: The contact status can be visually checked without power supply, facilitating fault diagnosis.
  2. Dual-color LED Indicator Light: Orange for AC coils and green for DC coils, clearly indicating the coil power-on status.
  3. Coil Parameter Labeling: Specification parameters are printed on the coil tape for quick identification of model and voltage.
  4. Optional Latch Lever Design: Facilitates locking the contact status during circuit inspection to improve maintenance efficiency.
  5. Enhanced Vibration Resistance: Withstands vibration of 200m/s² (approximately 20G), suitable for industrial field environments.
  6. Comprehensive International Certifications: Certificado por UL, CSA, VDE, CCC, etc., for global application.
  7. Wiring and Installation Guide
  8. Terminal Configuration (Bottom View)
Terminal NumberFunciónTerminal NumberFunción
1, 4, 7, 10Common Terminal (COM)2, 5, 8, 11Normally Closed Terminal (CAROLINA DEL NORTE)
3, 6, 9, 12Normally Open Terminal (NO)13, 14Coil (A1, A2)
  1. Basic Wiring Steps
  2. Insert the relay into a PYF series socket (p.ej., PYF14A-E) to ensure good contact.
  3. Connect the coil terminals (13/14) to the control power supply (note the polarity of DC coils).
  4. Connect the contact terminals to the load circuit:

Normalmente abierto (NO) Contacts: Closed when the coil is energized.

Normalmente cerrado (CAROLINA DEL NORTE) Contacts: Closed when the coil is de-energized.

Common (COM) Terminals: Serve as the center for contact switching.

  1. Surge Suppression Recommendations

Since the MY4N-GS-R has no built-in surge suppression component, it is recommended to connect a surge suppressor in parallel across inductive loads:

DC Loads: Connect a freewheeling diode in parallel (reverse connection).

AC Loads: Connect an RC snubber circuit or a varistor in parallel.

  1. Escenarios de aplicación
  2. Automatización Industrial: Expansion of PLC output interfaces to control loads such as contactors and solenoid valves.
  3. Control de motores: Used as an intermediate relay to isolate the control circuit from the main circuit.
  4. Control de temperatura: Cooperates with temperature controllers (p.ej., Liuzhou Yatai CH102FE02-M) to drive heaters or cooling equipment.
  5. Signal Conversion: Converts weak signals into strong signals or realizes voltage/current level conversion.
  6. Safety Circuits: Constructs safety protection circuits such as interlocks and emergency stops.
  7. Model Selection and Alternatives
ModeloDifferenceEscenario de aplicación
MY4N-GS-RStandard type without built-in surge suppressionGeneral control circuits requiring external surge protection
MY4N-D2-GS-RBuilt-in diode (for DC coils)DC control circuits to suppress reverse surges
MY4N-CR-GS-RBuilt-in RC snubber circuit (for AC coils)AC control circuits to suppress voltage spikes
MY4IN-GS-REnhanced insulation typeControl occasions w

VII. Precauciones de uso

  1. The coil voltage must match the control power supply to avoid burnout due to overvoltage or failure to operate due to undervoltage.
  2. The contact load shall not exceed the rated value; inductive loads require additional surge protection.
  3. Avoid severe impact or vibration on the relay during installation.
  4. Regularly check the working status of the mechanical indicator and LED indicator light to ensure the normal operation of the relay.
  5. Distinguish between coil terminals and contact terminals during wiring to prevent short-circuit faults.

With the characteristics of 4 sets of changeover contacts, 6A rated load, wide temperature adaptability, and high reliability, Omron MY4N-GS-R miniature power relay is widely used in various industrial control and electrical circuits. The specific application scenarios are as follows:

  1. PLC Output Interface Expansion in Industrial Automation

This is the core application scenario. PLC output ports have low load capacity and cannot directly drive high-power or high-voltage loads such as contactors, solenoid valves, and indicator lights. Using MY4N-GS-R as an intermediate relay, the PLC’s weak signal (p.ej., DC24V) can control the relay coil, and then the relay’s 4 sets of contacts can synchronously drive multiple external loads, realizing signal amplification and circuit isolation to avoid burnout of the PLC output module due to overload.

  1. Signal Transmission and Interlock in Motor Control Circuits

In motor start-stop, forward-reverse control circuits, MY4N-GS-R can act as an intermediate link to realize control signal transfer and safety interlock. Por ejemplo, its normally closed contacts are connected in series in the reverse control circuit to prevent simultaneous triggering of motor forward and reverse commands; or multiple sets of contacts are used to synchronously control the motor’s running indicator light and fault alarm device.

  1. Actuator Driving in Temperature Control Systems

It can be used in conjunction with temperature controllers (p.ej., Liuzhou Yatai CH102FE02-M): the solid-state output terminal (DC24V) of the temperature controller is connected to the coil of MY4N-GS-R, and the relay contacts are connected to high-power actuators such as heaters and cooling fans. This not only solves the problem of insufficient load capacity of the temperature controller output but also protects the core circuit of the temperature controller through electrical isolation.

  1. Signal Conversion and Voltage Level Matching

It is suitable for the connection scenarios of circuits with different voltage levels. Por ejemplo, converting a low-voltage DC control signal (DC24V) into an AC high-voltage output (CA 220 V.) to drive an AC contactor; or vice versa, using an AC control signal to control a DC load to realize cross-voltage level signal transmission.

  1. Safety Protection and Monitoring Circuits

In equipment emergency stop, sobrecarga, and short-circuit protection circuits, MY4N-GS-R can transmit fault signals. Por ejemplo, when a thermal relay detects motor overload, its contacts trigger the relay coil, and the relay’s multiple sets of contacts can simultaneously cut off the motor main circuit, light up the fault indicator light, and send an alarm signal to the control room.

  1. Building Automation and Security Systems

Used for controlling building equipment such as lighting, acondicionadores de aire, and access control. Por ejemplo, controlling the on-off of lighting circuits through relay contacts, or synchronously triggering multiple actions such as audible and visual alarms, access control locking devices, and surveillance video activation in security alarm systems.

  1. Signal Amplification of Instruments and Meters

For weak signals output by various sensors or detection instruments, MY4N-GS-R can convert them into strong electrical signals to drive recorders, alarms, and other equipment, ensuring stable signal transmission without interference.

Anterior:

Deja una respuesta

Dejar un mensaje