Pepperl+Fuchs KFU8-FSSP-1.D-Y Convertidor de señal - contactor,cortacircuitos,sensor,Codificador,SOCIEDAD ANÓNIMA,Convertidor

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

Pepperl+Fuchs KFU8-FSSP-1.D-Y Convertidor de señal - contactor,cortacircuitos,sensor,Codificador,SOCIEDAD ANÓNIMA,Convertidor

SOCIEDAD ANÓNIMA/

Pepperl+Fuchs KFU8-FSSP-1.D-Y Convertidor de señal

Nombre completo: Frequency/Voltage/Current (10 kHz Version) KFU8 series DIN rail signal conditioning module, designed for frequency/speed acquisition from encoders and pulse sensors, converting pulse signals into standard analog signals, with an optional frequency-divided pulse output. Distinción: KFU8-FSSP-1.D-Y = 10 kHz maximum input frequency KFU8-FSSP-1.D-Y322444 = 40 kHz high-speed version Many suppliers mix these two models; ...

  • Detalles del producto

Nombre completo: Frequency/Voltage/Current (10 kHz Version)

KFU8 series DIN rail signal conditioning module, designed for frequency/speed acquisition from encoders and pulse sensors, converting pulse signals into standard analog signals, with an optional frequency-divided pulse output.

Distinción:

KFU8-FSSP-1.D-Y = 10 kHz maximum input frequency

KFU8-FSSP-1.D-Y322444 = 40 kHz high-speed version

Many suppliers mix these two models; confirm the frequency limit during selection.

✅ Funciones principales

  1. Two measurement modes: Frecuencia (Hz) / Velocidad de rotación (rpm)

Rango de frecuencia: 0.001 Hz ~ 9999 Hz

Rango de velocidad: 0.02 rpm ~ 9999 rpm

  1. Configurable analog output (selectable via menu):

0…10 voltios / 2…10 voltios

0…20 mA / 4…20 mA

  1. Frequency-divided pulse output: division ratio 1~9999, isolated pulse signal for PLC or secondary instruments
  2. Incorporado 24 V DC auxiliary sensor power supply; compatible with 2/3/4-wire proximity switches and NPN/PNP incremental encoders
  3. 4-digit red LED display; shows input Hz/rpm or output V/mA. 4-button local programming with one-touch Teach-In calibration
  4. Period measurement method, optimized for low-speed pulse signals

📌 Electrical Specifications

Fuente de alimentación: 24 En DC

Consumo de energía: <5 W

Max input frequency: 10 kilociclos (este modelo); minimum pulse width ≥40 μs

Exactitud: ≤0.2% FS

Processing response: 5 ms internal update; display refresh adjustable from 0.01~2.5 s (no impact on signal conversion)

Aislamiento: Galvanic isolation between input and analog output

Clase de protección: IP20 (montaje en gabinete solamente)

Montaje: Snap-on 35 carril DIN mm

Terminales: Removable coded terminals, wire cross-section 0.2~2.5 mm²

Temperatura de funcionamiento: -25 ℃ ~ +40 ℃ (sin condensación)

Temperatura de almacenamiento: -40 ℃~+85 ℃

📋 Terminal Assignment

TerminalSeñal
1Sensor GND
2Salida de pulso
5Salida analógica +
6Salida analógica – (Voltaje)
4Salida analógica – (Actual)
7Sensor 24 V+
11Power Supply L+ 24 En DC
12Power Supply L- 0 V
14NPN/PNP Input – (Cathode)
15NPN/PNP Input + (Anode)
13Sensor GND
Remaining terminalsCAROLINA DEL NORTE (No conectado)

⚙️ Factory Default Parameters

Modo: rpm (Velocidad de rotación)

Pulse per revolution (PPR): 1

Full Scale Range: 9999

Salida analógica: 0…10 voltios

Display Refresh Time: 0.33 s

Division Ratio: 1

Guardar parámetros: Long-press Enter + + to store into EEPROM (power-down retention)

🛠 Aplicaciones típicas

Speed measurement for conveyors, fans, pumps and roller tables

Converting pulse signals from flowmeters into 4–20 mA analog signals for DCS/PLC

Encoder signal division, local speed display + analog transmission

Stable measurement of low-frequency pulse signals (period measurement outperforms frequency counting at low speeds)

⚠️ Guía de solución de problemas

FallaPosibles causas & Remedios
No power, sin pantalla1. Controlar 24 V DC at terminals 11/12; 2. Terminales sueltos; 3. Reverse polarity protection activated
Signal present but reading always zero1. NPN/PNP wiring reversed; 2. Pulse width ≥40 μs; 3. No 24 V on sensor supply terminal 7; 4. Wrong measurement mode (rpm/Hz)
Lecturas fluctuantes1. Increase display refresh time; 2. Use shielded cable with single-end grounding; 3. Check voltage drop on encoder supply; 4. Ensure high level ≥16 V DC, low level ≤6 V DC
Analog output stuck1. Match current/voltage output type with AI card; 2. Max load resistance ≤600 Ω for current output; 3. Re-run Teach-In calibration
Display overflow1. Actual speed exceeds set RANGE; 2. Incorrect PPR setting (value too large)
No pulse output on terminal 21. Division ratio ≠ 1; 2. Open-collector output requires external pull-up resistor on PLC side; 3. Input frequency below lower limit
Self-test error Err on power-upEEPROM checksum failure; power cycle first; repeated error means hardware failure, replace the module
Poor low-speed accuracyThis module uses period measurement; ensure pulse width ≥40 μs; avoid ultra-narrow pulses

📎 Cross-model & Opciones de reemplazo

Misma serie: KFU8-FSSP-1.D-Y322444 (40 kilociclos, for high-speed encoders)

Alternativas domésticas: CZJ, UBE frequency/speed isolators (must support period measurement + frequency-divided pulse output)

  1. Instrucciones de cableado (KFU8-FSSP-1.D-Y)

Full Terminal List

TerminalDefinición de señalNota
1Sensor GNDSpare sensor ground
2Frequency-divided Pulse OutputIsolated pulse for PLC high-speed counter
4Current Output I-Negative terminal for 4…20 mA
5Analog U+/I+Common positive for voltage & current output
6Voltage Output U-Negative terminal for 0…10 V
7Sensor 24 V+Encoder/proximity sensor supply, máximo. 30 mamá
8NAMUR Input –NAMUR sensor channel
9NAMUR Input +NAMUR sensor channel
11Module Power L+ 24 En DCMain power positive
12Module Power L- 0 VMain power negative
13Sensor GNDSensor power ground
14NPN/PNP Input – (Cathode)Pulse negative
15NPN/PNP Input + (Anode)Pulse positive
OtrosCAROLINA DEL NORTEDo not connect

Standard Wiring Schemes

  1. 3-wire PNP Encoder (Más común)

Brown wire → Terminal 7 (24 V+)

Blue wire → Terminal 13 (Tierra)

Black signal wire → Terminal 15; Terminal 14 shorted to 13 (Tierra)

  1. 3-wire NPN Encoder

Marrón → 7; Azul → 13

Black signal → 14; Terminal 15 shorted to 7 (24 V+)

  1. 4–20 mA analog to DCS AI card

Terminal 5 → AI+; Terminal 4 → AI-

  1. 0…10 V voltage output

Terminal 5 → AI+; Terminal 6 → AI-

  1. Frequency-divided pulse output

Terminal 2 to PLC high-speed counter; fit external pull-up resistor on PLC side

Aviso importante: Max sensor supply current = 30 mamá; do not drive multiple encoders. Use shielded cable for long-distance pulse wiring, ground the shield only at one end.

  1. Button Operation & Parameter Setup

4 front-panel keys: Modo (Menú), ◀, +, Ingresar

  1. Encendido; wait for self-test then enter measurement display (Hz/rpm)
  2. Short press Mode to switch menu items; ◀ = shift digit; + = change value
  3. Guardar parámetros: Long press Enter + + together to write into EEPROM (retained after power loss)
  4. Exit menu: Long press Mode to return to measurement screen

Menu Items (English Original)

  1. MODO: Measurement Mode

rpm = Rotational Speed (Encoder application recommended)

Hz = Frequency (Pulse flowmeter)

  1. PULSE: Pulses Per Revolution (PPR)

Ejemplo: 1000-line encoder → set PULSE=1000

  1. RANGE: Full Scale Value

Ejemplo: 0~1500 rpm → set RANGE=1500

  1. AFUERA: Tipo de salida

0-10V / 2-10V / 0-20mamá / 4-20mamá

  1. DIV: Division Ratio (1~9999)

Output pulse = Input pulse ÷ DIV; set DIV=1 if no division required

  1. DISP: Display Refresh Time (0.01~2.5 s)

Increase to 0.5~1 s to stabilize low-speed readings; colocar 0.1 s for high speed

  1. TEACH: One-touch Calibration (Teach-In)

Run equipment to full-scale speed, enter TEACH and press Enter; auto-set upper range (zero point fixed at 0)

Valor predeterminado de fábrica: MODE=rpm, PULSE=1, RANGE=9999, OUT=0…10V, DIV=1, DISP=0.33 s

Procedimiento de restablecimiento de fábrica

Encendido, hold Mode + Enter for 5 seconds until FACT appears; confirm to restore all factory settings. All custom parameters will be erased.

  1. Fault Troubleshooting Table
SíntomaPasos para solucionar problemas
No display after power-up1. Medida 24 V DC between terminals 11 & 12; 2. Check loose terminals; 3. Reverse polarity protection triggered
No reading, display stays zero1. Verify NPN/PNP wiring polarity; 2. Ensure pulse width ≥40 μs; 3. Controlar 24 V output on terminal 7; 4. Confirm correct MODE (rpm/Hz)
Inestable, flickering readings1. Increase DISP refresh time; 2. Shield cable single-end grounded; 3. Check voltage drop on encoder supply; 4. High level ≥16 V DC, low level ≤6 V DC
Analog output locked and unchanged1. Match OUT type with AI card (current/voltage cannot be mixed); 2. Current output load resistance ≤600 Ω; 3. Re-run TEACH calibration
Display over-range overflow1. Actual speed exceeds RANGE setting; 2. PPR value set too high
No pulse output on terminal 21. DIV ratio not equal to 1; 2. Open-collector output requires external power/pull-up resistor on PLC; 3. Input frequency below lower limit
Err code on power-up self-testEEPROM data error; restart first; repeated error = hardware damage, reemplazar módulo
Inaccurate low-speed measurementThis module uses period measurement (good for low speed); ensure pulse width ≥40 μs, avoid ultra-narrow pulses
  1. Parameter Table (Chinese ↔ English, Exportable)
Chinese ParameterEnglish TagRangoObservaciones
测量模式MODOrpm / HzVelocidad / Frecuencia
每转脉冲数PULSE1~9999Encoder PPR value
满量程RANGE1~9999Corresponds to full-scale analog output
输出类型AFUERA0-10V,2-10V,0-20mamá,4-20mamáAnalog signal selection
分频系数DIV1~9999Pulse output division
显示刷新时间DISP0.01~2.5 sOnly affects display, no impact on conversion speed
一键标定TEACH—Dynamic full-scale calibration
精度Exactitud≤0.2%FSFull-scale accuracy
最大输入频率Fmax10 kilociclosFor model Y only (not Y322444)
  1. Procedimiento de puesta en servicio (On-site Sequence)
  2. Wire with power disconnected; double-check power, encoder and analog terminals
  3. Encendido; verificar 24 V DC on sensor supply terminal 7
  4. Set MODE, PPR, RANGE and OUT type
  5. Rotate the encoder and confirm reading follows actual speed
  6. Measure analog output with multimeter, verify zero and full-scale values
  7. If pulse division is needed: connect PLC high-speed counter and test terminal 2 pulse signal
  8. Save parameters and record settings; commissioning complete

Pepperl+Fuchs KFU8 Series DIN Rail Signal Converter Order List

Descripción: KFU8 = K-System local-display programmable signal conditioners; divided into standard type and Ex intrinsically safe barrier type.

Suffix rules:

1.D = 1-channel; 2.D = 2-channel

Y = 10 kHz input; Y322444 = 40 kilociclos (only for FSSP models)

Ex = Intrinsically safe for hazardous area Zone 0/1/2

Order Part NumberNombre del productoBrief FunctionA prueba de explosiones
KFU8-FSSP-1.D-YFrequency/Speed Converter (10 kilociclos)Encoder pulse → analog 0-10V/4-20mA, with frequency-divided pulse output & pantalla localNo
KFU8-FSSP-1.D-Y322444Frequency/Speed Converter (40 kilociclos)Same as FSSP, máximo 40 kHz for high-speed encodersNo
KFU8-DW-1.DSpeed MonitorOverspeed/underspeed monitoring with relay alarm output; máximo 40 kilociclos, period measurementNo
KFU8-UFC-1.DFrequency Converter with Limit Alarms1 mHz~10 kHz; NAMUR/dry contact input; 4-20mamá + relé + salida de transistor; SIL2No
KFU8-UFC-1.D.FAConvertidor de frecuencia (Old Version)Legacy model; phase-out, replace with UFC-1.DNo
KFU8-UFC-Ex1.DIntrinsically Safe Frequency BarrierA partir de ahora, Zona 0/1/2, NAMUR input, SIL2Sí (A partir de ahora)
KFU8-UFT-2.DDual-channel Frequency/Slip/Speed Direction MonitorDual NAMUR/dry contact input; detect rotation direction, slip and synchronous deviation; cosa análoga + salida de reléNo
KFU8-UFT-Ex2.DExplosion-proof Dual-channel Direction/Slip BarrierMonitoreo de rotación de doble canal en áreas peligrosasSí (A partir de ahora)
KFU8-USC-1.DConvertidor universal de señal de voltaje/corrienteAislamiento & escalado para 0/4-20mA & 0-10V señales analógicas; con alarma de relé de límiteNo
KFU8-GUT-Ex1.DTransmisor de temperatura universal intrínsecamente seguroEntrada RTD/termopar, alarma de doble relé, SIL2Sí (A partir de ahora)

Regla de codificación del modelo

KFU8 [Código de función] [Canal].[Versión] [-Sufijo]

FSSP: Frecuencia Velocidad → Transmisión de velocidad con salida de pulso dividida

DW: Vigilancia de velocidad → Monitoreo de velocidad & alarma

UFC: Convertidor de frecuencia universal → Conversión de frecuencia + alarma límite

UFT: Universal Frequency Twin → Frecuencia de doble canal, dirección & monitoreo de deslizamiento

USC: Convertidor de señal universal → Aislamiento de señal analógica estándar

INTESTINO: Temperatura universal → Transmisión de señal de temperatura

Ex: Barrera intrínsecamente segura a prueba de explosiones

1.D = canal único; 2.D = Doble canal

Y = 10 kilociclos; Y322444 = 40 kilociclos (Sufijo exclusivo de FSSP)

Accesorios comunes de la serie KFU8

K-CJC-EX: Terminal de compensación de unión fría (for GUT temperature modules)

KF-ST-5BU / KF-ST-5GN: Removable coded terminals (blue/grey)

Power Rail: K-series power bus for multi-module parallel power supply

Guía de selección rápida

  1. Speed transmission + divided pulse output → FSSP (Y / Y322444)
  2. Overspeed/underspeed alarm (no divided pulse) → DW-1.D
  3. NAMUR proximity switch frequency input + alarm → UFC / UFC-Ex
  4. Dual encoders, slip & rotation direction detection → UFT-2.D / UFT-Ex2.D
  5. Analog 4-20mA/0-10V isolation, scaling & alarm → USC-1.D
  6. RTD/TC temperature measurement in hazardous area → GUT-Ex1.D

Notas complementarias

All KFU8 modules: 40 mm de ancho, 35 montaje en carril DIN, 4-pantalla de dígitos + 4-button programming; different from non-display KFD0 / KFA5 barriers.

Fuente de alimentación: Most models support 20~90 V DC / 48~253 V AC; FSSP model only supports 24 En DC.

Aviso de fin de vida: UFC-1.D.FA is obsolete; select UFC-1.D for new projects.

Anterior:

Deja una respuesta

Dejar un mensaje