Phoenix 2981800 Safety Relay - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

Phoenix 2981800 Safety Relay - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

eléctrico/

Phoenix 2981800 Safety Relay

  Model Segment Full Designation Description 2981800 Número de pedido. Phoenix Contact global unique part number PSR PSR Phoenix Contact PSR series safety relay (Programmable Safety Relay) SCP SCP Safety function: dedicated for Emergency Stop / Safety Gate monitoring (Safety Control for E-Stop/Door) 24DC 24DC Control voltage: DC24V input ESD ESD Function feature: Emergency Stop Delay ...

  • Detalles del producto

 

Segmento de modeloFull DesignationDescripción
2981800Número de pedido.Contacto Fénix global unique part number
PSRPSRPhoenix Contact PSR series safety relay (Programmable Safety Relay)
SCPSCPSafety function: dedicated for Emergency Stop / Safety Gate monitoring (Safety Control for E-Stop/Door)
24corriente continua24corriente continuaControl voltage: DC24V input
ESDESDFunction feature: Emergency Stop Delay
4X14X1Configuración de contacto: 4 contactos (2 safety NO + 2 auxiliary NO), 1-channel safety input
3030Delay range: adjustable power-off delay 0.1s ~ 30s

Aplicación principal: Single-channel safety relay for Emergency Stop and Safety Gate monitoring. It complies with safety rating SIL 3 / Cat.4 PL e, with 0.1–30s adjustable power-off delay. Suitable for protection scenarios of automated equipment requiring safety stop delay.

  1. Especificaciones principales
Categoría de parámetroEspecificación detalladaObservaciones
Desempeño de seguridadNivel de seguridad: SIL 3 (CEI 61508)Meets highest industrial safety requirements
Nivel de rendimiento: pl y, Categoría 4 (EN ISO 13849-1)
PFHd: 2.5×10⁻⁸/h
Características de entradaVoltaje de control: CC 24 V (19.2~28.8V)Compatible with standard industrial 24V DC control systems
Corriente de entrada: Max 40mA
Input Channel: 1 safety input (NC/NO optional)
Modo de reinicio: Automatic / Manual selectable
Características de salidaSafety Contacts: 2 pcs N/O (Force-guided)Force-guided safety contacts ensure fail-safe operation
Contactos auxiliares: 2 pcs N/O
Calificación de contacto: AC-15: 230V/2.5A
DC-13: 24V/2.5A
Max Switching Voltage: 250VCA/CC
Max Switching Current: 6A
Delay CharacteristicsPower-off delay: continuously adjustable 0.1s~30sAdapt to different equipment stopping time requirements
Setting Accuracy: ±10%
Características físicasDimensiones: W22.5mm × H99mm × D121mmSingle-channel width, ahorra espacio en el gabinete
Peso: Aprox.. 0.22kilos
Montaje: 35carril DIN mm (EN 60715)
Alambrado: Plug-in screw terminals
Environmental CharacteristicsTemperatura de funcionamiento: -20~+60℃Industrial-grade environmental adaptability for harsh working conditions
Temperatura de almacenamiento: -40~+85℃
Humedad: 5~95%RH (sin condensación)
Vibration Resistance: 10~150Hz, 2gramo
Shock Resistance: 15gramo
Certificaciones de seguridadCE, UL, CSA, TUV, ATEXCumple con los estándares internacionales de seguridad., globally applicable
  1. Lista de accesorios & Installation Guidelines

3.1 Accesorios estándar

Safety relay unit ×1

Installation manual ×1

Terminal marking label ×1

Fixing clip ×2 (for DIN rail locking)

Delay adjustment screwdriver ×1 (special tool)

3.2 Precauciones de instalación

  1. Mounting Requirement: Install on standard 35mm DIN rail; maintain ≥5mm clearance from adjacent modules for heat dissipation.
  2. Especificación de cableado:

Circuito de control: Connect DC24V to A1(+)、A2(-)

Safety Input: Connect E-stop / safety gate contact to S11S12 (NC contact preferred)

Salida de seguridad: Connect safety circuit (p.ej. bobina del contactor) a 13-14、23-24

Auxiliary Output: Connect alarm / indication circuit to 31-32、41-42

  1. Reset Setting:

Auto Reset: Automatically restore after power cycle

Reinicio manual: Requires external reset signal or manual reset button operation

  1. Delay Adjustment: Use the dedicated screwdriver to adjust the front panel potentiometer to set 0.1–30s power-off delay.
  2. Cross-model & Cross-brand Replacement

4.1 Phoenix Contact Same Series Alternative Models

Model No.Diferencia centralEscenario de aplicación
29818001 canal, 2 seguridad + 2 contactos auxiliares, 0.1–30s delayStandard E-stop / safety gate monitoring (current model)
29818011 canal, 2 seguridad + 2 contactos auxiliares, 0.1–10s delayEquipment with short stopping time
29818021 canal, 2 seguridad + 2 contactos auxiliares, 0.1–1s delayFast stop equipment
29818102 canales, 4 seguridad + 2 contactos auxiliares, no delayDual-channel redundant safety system
29818201 canal, 2 seguridad + 2 contactos auxiliares, with alarm outputSystem requiring alarm indication

4.2 Cross-brand Equivalent Solutions

MarcaModeloParámetros claveCompatibility Note
SchneiderZelio SR2P121BD1 canal, 2 safety contacts, 24En DC, Cat.4Similar function, different wiring layout
siemens3SK1111-1AB301 canal, 2 safety contacts, 24En DC, SIL 3Different dimensions, cabinet rearrangement required
OmrónG9SA-321-T151 canal, 2 safety contacts, 24En DC, Cat.4Delay range 0.05–10s, slightly narrower
TEJIDOMSR12751 canal, 2 safety contacts, 24En DC, SIL 3Precio más alto, fully identical function
WeidmüllerDRM570730LT1 canal, 2 safety contacts, 24En DC, Cat.4Fixed 1s non-adjustable delay

 

  1. Selección & Pautas de reemplazo

5.1 Criterios de selección básicos

✅ Safety Level Matching: Ensure required safety rating (SIL/PL/Cat.) does not exceed product capability (SIL 3 / Cat.4 PL e).

✅ I/O Requirement:

Aporte: 1 channel sufficient; confirm NC or NO contact type.

Producción: Verify 2 seguridad + 2 auxiliary contacts meet control demands.

Capacidad de contacto: Ensure load current ≤2.5A (AC-15/DC-13).

✅ Delay Requirement: Confirm 0.1–30s adjustable range covers equipment stopping time.

✅ Reset Mode: Select auto or manual reset according to operation needs.

✅ Environmental Adaptation: Operating temperature ≤60℃ and humidity within industrial standard range.

5.2 Mejora & Opciones de reemplazo

Option A: Same Series Function Upgrade

More channels: 2981800 → 2981810 (2 canales, 4 safety contacts)

Add alarm output: 2981800 → 2981820 (with alarm output)

Shorter delay: 2981800 → 2981801 (0.1–10s) o 2981802 (0.1–1s)

Option B: Migrate from PSRclassic to PSRmini (Space Optimization)

Modelo de reemplazo: 2981900 (PSRmini-SCP-24DC/ESD/4X1/30)

Ventaja: Only 17.5mm width (5mm narrower), funciones idénticas, ahorra espacio en el gabinete.

Option C: Migrate from PSRclassic to PSRmodular (System Expansion)

Solución: PSRmodular system + safety function modules

Ventaja: Multi-channel expandable; integrates safety gate, Molestar, light curtain and other safety functions, suitable for complex safety systems.

5.3 Solución de problemas comunes

Fenómeno de fallaPossible CauseSolución
Module indicator offControl power disconnected or faultyCheck DC24V input, measure voltage within 19.2~28.8V
No safety output actionSafety input loop openCheck E-stop / safety gate contact wiring and loop continuity
Abnormal delay timeImproper potentiometer adjustmentReadjust with dedicated screwdriver; calibrate with timer recommended
Reiniciar fallaIncorrect reset mode settingVerify auto/manual reset configuration and check reset signal
Adhesión por contactoOverload current exceededMeasure load current; add intermediate relay if necessary

Contacto Fénix 2981800 (PSR-SCP-24DC/ESD/4X1/30) is a single-channel safety relay with adjustable power-off delay, specially designed for emergency stop and safety gate monitoring, reaching the highest safety level SIL 3 / Cat.4 PL e. Its 22.5mm slim design and plug-in wiring facilitate installation and maintenance, while the 0.1–30s adjustable delay adapts to various equipment shutdown requirements. Durante la selección, focus on safety rating, configuración de E/S, delay range and reset mode. For upgrade, choose extended models in the same series or migrate to PSRmini / PSRmodular for space saving or system expansion.

Complete Model List of Phoenix Contact Safety Relays (Structured Classification)

  1. Model Naming Rule Overview
PrefijoCódigo de serieMiddle CodeSignificadoSufijoSignificado
PSRBasic identifier for Phoenix safety relaySCPMolestar / Safety Gate dedicated24corriente continuaControl voltage DC24V
PSRSafety RelaySPPStandard Safety ProtectionESDEmergency Stop Delay (0.1-30s)
PSRSafety RelayMCMini Compact4X1Contacto: 4 NO (2 seguridad + 2 auxiliar)
PSRSafety RelayMSMonitoring Safety30Delay time range (0.1-30s)
PSRSafety RelayUNIUniversal ConfigurablePIPush-in spring terminal
PSRSafety RelayMMMotion MonitoringCAROLINA DEL SURScrew terminal
  1. PSRclassic Series (Standard Safety Relays)

2.1 Molestar / Safety Gate (SCP Series)

ModeloNúmero de pedido.Core ParameterNivel de seguridadSolicitud
PSR-SCP-24DC/ESD/4X1/3029818001Ch, 2Safety+2Aux, 0.1-30s delaySIL 3/Cat.4 PL eStandard E-stop / Safety Gate
PSR-SCP-24DC/ESD/4X1/1029818011Ch, 2Safety+2Aux, 0.1-10s delaySIL 3/Cat.4 PL eShort stop time equipment
PSR-SCP-24DC/ESD/4X1/129818021Ch, 2Safety+2Aux, 0.1-1s delaySIL 3/Cat.4 PL eFast stop equipment
PSR-SCP-24DC/ESD/5X1/1X2/30029814281/2Ch, 3Safety+1NC+2Aux, 0.1-300s delaySIL 3/Cat.4 PL eLong delay shutdown system
PSR-SCP-24UC/ESA4/3X1/1X2/B29637632Ch, 3Safety+1Aux, no delaySIL 3/Cat.4 PL eDual-channel redundant safety system
PSR-SCP-24DC/MXF3/4X1/2X2/B2903257Multi-Ch, 4Safety+2Aux, 3 safety functionsSIL 3/Cat.4 PL eMulti-function safety monitoring

2.2 Standard Safety Function (SPP Series)

ModeloNúmero de pedido.Core ParameterNivel de seguridadSolicitud
PSR-SPP-24DC/SDC4/2X1/B29014261Ch, 2Safety contacts, no delaySIL 3/Cat.4 PL eBasic safety loop
PSR-SPP-230AC/ESAM2/3X1/1X2/B29014311Ch, 3Safety+1Aux, CA 230 V.SIL 3/Cat.4 PL eAC power supply system
PSR-SPP-24UC/URM/3X1/3X229014271Ch, 3Safety+3Aux, universal voltageSIL 3/Cat.4 PL eMulti-voltage compatible system
PSR-SPP-24DC/ESD/3X1/1X2/3029814271Ch, 3Safety+1Aux, 0.1-30s delaySIL 3/Cat.4 PL eDelay-type safety system

2.3 Light Curtain Monitoring (SCR Series)

ModeloNúmero de pedido.Core ParameterNivel de seguridadSolicitud
PSR-SCR-24DC/3X1/1X229815002Ch, 3Safety+1Aux, dedicated for light curtainSIL 3/Cat.4 PL eStandard light curtain monitoring
PSR-SCR-24DC/4X1/2X229815012Ch, 4Safety+2Aux, dedicated for light curtainSIL 3/Cat.4 PL eComplex light curtain safety system
PSR-SCR-24DC/5X1/1X229815022Ch, 5Safety+1Aux, dedicated for light curtainSIL 3/Cat.4 PL eHigh-density safety output

2.4 Two-Hand Control (SCT Series)

ModeloNúmero de pedido.Core ParameterNivel de seguridadSolicitud
PSR-SCT-24DC/2X1/1X229816002Ch, 2Safety+1Aux, two-hand controlSIL 3/Cat.4 PL eStandard two-hand operation
PSR-SCT-24DC/3X1/2X229816012Ch, 3Safety+2Aux, two-hand controlSIL 3/Cat.4 PL eComplex two-hand operation
  1. PSRmini Series (Micro Compact, 17.5mm Width)

3.1 Basic Safety Function (MC Series)

ModeloNúmero de pedido.Core ParameterNivel de seguridadSolicitud
PSR-MC32-3NO-1NC-24-230UC-SP27005251/2Ch, 3Safety+1NC, universal voltageSIL 3/Cat.4 PL eGeneral safety monitoring
PSR-MC34-3NO-1DO-24DC-SP27005481/2Ch, 3Safety+1diagnostic output, CC 24 VSIL 3/Cat.4 PL eSystem with diagnostic output
PSR-MC45-3NO-1DO-24DC-SC10820241Ch, 3Safety+1diagnostic output, CC 24 VSIL 3/Cat.4 PL eCompact E-stop system
PSR-MC22-2NO-1NC-24DC-SP27005001Ch, 2Safety+1NC, CC 24 VSIL 3/Cat.4 PL eSmall safety loop

3.2 Safety Monitoring Module (MS Series)

ModeloNúmero de pedido.Core ParameterNivel de seguridadSolicitud
PSR-MS21-1NO-1DO-24DC-SC27021921Ch, 1Safety+1digital output, CC 24 VSIL 3/Cat.4 PL eSafety controller expansion
PSR-MS31-2NO-1DO-24DC-SP27022001Ch, 2Safety+1digital output, CC 24 VSIL 3/Cat.4 PL eSafety status monitoring
  1. PSRmodular Series (Modular Safety System)

4.1 Main Control Module

ModeloNúmero de pedido.Core ParameterNivel de seguridadSolicitud
PSR-UNI-L-1X4NO-1DO-24DC-PI14876481/2Ch, 4Safety+1DO, configurableSIL 3/Cat.4 PL eUniversal configurable safety system
PSR-UNI-L-2X4NO-2DO-24DC-PI14876492Ch, 8Safety+2DO, configurableSIL 3/Cat.4 PL eComplex safety system
PSR-UNI-L-1X2NO-1NC-1DO-24DC-PI14876501/2Ch, 2Safety+1NC+1DOSIL 3/Cat.4 PL eSystem with NC output

4.2 Expansion Module

ModeloNúmero de pedido.Core ParameterNivel de seguridadSolicitud
PSR-EXT-L-1X4NO-24DC-PI14876514-safety output expansionSIL 3/Cat.4 PL eOutput expansion
PSR-EXT-L-1X2NO-1NC-24DC-PI14876522Safety+1NC output expansionSIL 3/Cat.4 PL eMixed output expansion
  1. PSRmotion Series (Motion Monitoring Safety Relay)

5.1 Zero Speed / OverSpeed Monitoring

ModeloNúmero de pedido.Core ParameterNivel de seguridadSolicitud
PSR-MM25-1NO-2DO-24DC-SC2702355Sensorless zero-speed monitoring, 3-motor de faseSIL 3/Cat.3 PL eMotor zero-speed safety protection
PSR-MM35-1NO-2DO-24DC-SC2702356Overspeed monitoring, 3-motor de faseSIL 3/Cat.3 PL eMotor overspeed safety protection
PSR-MM45-1NO-2DO-24DC-SC2702357Zero-speed + overspeed dual monitoring, 3-motor de faseSIL 3/Cat.3 PL eFull motor speed monitoring

5.2 Rotation Direction Monitoring

ModeloNúmero de pedido.Core ParameterNivel de seguridadSolicitud
PSR-MD25-1NO-2DO-24DC-SC2702360Rotation direction monitoring, 3-motor de faseSIL 3/Cat.3 PL eMotor rotation direction safety control
  1. Safety Coupling Relays (PSR-SCP/SPP Series)
ModeloNúmero de pedido.Core ParameterNivel de seguridadSolicitud
PSR-SCP-24DC/FSP/1X1/1X229817001Safety+1Aux contact, coupling functionSIL 3Safety signal isolation
PSR-SCP-24DC/FSP2/2X1/1X229817012Safety+1Aux contact, coupling functionSIL 3Dual-channel safety isolation
PSR-PS21-1NO-1NC-24DC-SC29817021Safety+1NC contact, coupling functionSIL 3Safety signal switching
  1. Key Selection Parameter Comparison
Categoría de parámetroKey IndexConsejos de selección
Nivel de seguridadSIL 1-3, Cat.1-4, PL a-eDetermined by equipment risk assessment; max support SIL 3/Cat.4 PL e
Input Channel1 Channel / 2 ChannelSingle channel for basic safety; dual channel for redundant safety
Configuración de contactoQuantity of safety / contactos auxiliares≥2 safety contacts recommended; auxiliary contacts for alarm & indication
Voltaje de controlCC 24 V / CA 230 V. / UniversalMatch on-site control system power supply
Function FeatureDelay / Diagnostic / Cross-circuit detectionE-stop requires delay; complex system needs diagnostic function
Mounting Width17.5milímetros / 22.5milímetros / 27.5milímetrosChoose PSRmini (17.5milímetros) for limited cabinet space
Wiring TypeTornillo / Push-in springPush-in for frequent wiring; screw type for vibration environment
  1. Notas complementarias

8.1 Posicionamiento en serie

PSRclassic: Standard type with complete functions, width starting from 22.5mm, suitable for conventional safety applications.

PSRmini: Micro compact type, only 17.5mm width, ahorra espacio en el gabinete.

PSRmodular: Configurable modular system, suitable for complex safety systems with expandable functions.

PSRmotion: Dedicated for motion monitoring, applicable to motor zero-speed / overspeed / rotation direction safety control.

8.2 Replacement Information

Old models are gradually phased out; priority recommended to select models manufactured after 2020.

Some models are discontinued; refer to Phoenix Contact official website or technical support for replacement.

8.3 Certificación de seguridad

Full series certified by CE, UL, CSA, TUV, Cumple con IEC 61508 and EN ISO 13849-1.

Partial models with ATEX certification for explosive atmosphere applications.

Anterior:

Próximo:

Deja una respuesta