Contacto Fénix 2986575 Safety Coupling Relay - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

Contacto Fénix 2986575 Safety Coupling Relay - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

eléctrico/

Contacto Fénix 2986575 Safety Coupling Relay

Contacto Fénix 2986575 (PSR-SCP-24DC/FSP2/2X1/1X2) Safety Coupling Relay SIL 2 certified safety coupling relay, 24Fuente de alimentación VCC, 2 normalmente abierto + 1 contactos normalmente cerrados, integrated FSP2 test pulse filter, 17.5mm narrow-width DIN rail mounting. Suitable for safety shutdown applications. Número de pedido. 2986575. Model Segment Definition Model Segment Description PSR Product series: Phoenix Contact classic ...

  • Detalles del producto

Contacto Fénix 2986575 (PSR-SCP-24DC/FSP2/2X1/1X2) Safety Coupling Relay

SIL 2 certified safety coupling relay, 24Fuente de alimentación VCC, 2 normalmente abierto + 1 contactos normalmente cerrados, integrated FSP2 test pulse filter, 17.5mm narrow-width DIN rail mounting. Suitable for safety shutdown applications. Número de pedido. 2986575.

  1. Definición del segmento del modelo
Segmento de modeloDescripción
PSRSerie de productos: Phoenix Contact classic safety relay series (PSRclassic)
SCPProduct type: Safety Coupling Relay
24corriente continuaTensión de funcionamiento: 24En DC
FSP2Function code: Filter for Test Pulses Version 2, compatible with SIL 2 aplicaciones
2X1Safety contact configuration: 2 normalmente abierto (NO) enable current paths
1X2Configuración de contactos auxiliares: 1 normalmente cerrado (CAROLINA DEL NORTE) signal/alarm contact
2986575Phoenix Contact official order number, globally unique identifier
  1. Full Version Core Specification Table
Categoría de parámetroSpecific ParameterObservaciones
Basic InfoSafety coupling relay, SIL 2 certificado, Gato. 1, Grado de protección IP20Compliant with EN 61508
Número de pedido.2986575Order strictly by this part number
DimensionesW17.5mm × H99mm × D114.5mmDIN rail mount, ahorra espacio en el gabinete
Voltaje de funcionamiento24En DC, rango permitido: 19.2V~28.8V DCRipple ≤10%
Parámetros de la bobinaResistance 436.36Ω, current approx. 55mamáPower consumption approx. 1.32W.
Configuración de contacto2 NO enable paths + 1 NC alarm contactForced guided contacts, compatible con EN 50205
Calificación de contacto5A @ 250V AC / 30En DCAgCuNi contact material, larga vida útil
Características de seguridadIntegrated test pulse filter, prevents false triggering by controller self-test pulsesApplied to safety shutdown scenarios
Tipo de conexiónPlug-in screw terminal, wire size 0.2mm²~2.5mm²Easy quick replacement & mantenimiento, reliable wiring
Condiciones ambientalesOperating temp: -25°C ~ +55°C; Storage temp: -40°C ~ +85°C; Relative humidity ≤95% (sin condensación)Industrial standard environmental adaptability
Certificaciones de seguridadCE, UL, CSA, SIL 2 (CEI 61508), Gato. 1 (EN ISO 13849)Meets safety requirements of major global markets
Vida mecánica10⁷ operationsvida electrica: 10⁵ operations at rated load
PesoAprox.. 100gramoLightweight design
  1. Full Series Model List (PSR-SCP Safety Coupling Relay)
Número de pedido.ModeloVoltajeFunction CodeConfiguración de contactoNivel de seguridadCaracterísticas especiales
2986575PSR-SCP-24DC/FSP2/2X1/1X224corriente continuaFSP22NO+1NCSIL 2Test pulse filtering, safety shutdown
2986960PSR-SCP-24DC/FSP/2X1/1X224corriente continuaFSP2NO+1NCSIL 3Test pulse filtering, safety shutdown
2981978PSR-SCP-24DC/FSP/1X1/1X224corriente continuaFSP1NO+1NCSIL 3Test pulse filtering, single-channel enable
2981839PSR-SCP-24UC/URM/3X1/3X224UCURM3NO+3NCSIL 3Wide-range voltage, forced guided contacts
2963747PSR-SCP-24UC/URM/5X1/2X224UCURM5NO+2NCSIL 3Wide-range voltage, forced guided contacts
2963750PSR-SCP-24UC/ESA4/2X1/1X224UCESA42NO+1NCSIL 3parada de emergencia / safety gate monitoring dedicated
2963763PSR-SCP-24UC/ESA4/3X1/1X2/B24UCESA43NO+1NCSIL 3With base, parada de emergencia / safety gate monitoring
2981428PSR-SCP-24DC/ESD/5X1/1X2/30024corriente continuaESD5NO+1NCSIL 3300ms time delay, safety gate monitoring
2981020PSR-SCP-24DC/ESA4/1X1/1X224corriente continuaESA41NO+1NCSIL 3Single-channel, parada de emergencia / safety gate monitoring
  1. Competidor / Obsolete Model Replacement List

4.1 Same Brand Alternative Models (Directly Compatible)

Modelo OriginalModelo de reemplazoReplacement DescriptionEscenario de aplicación
2986575 (FSP2 Version)2986960 (FSP Version)Upgraded to SIL 3 proceso de dar un título, functionally compatible with improved performanceApplications requiring higher safety integrity level
2986575PSR-PC32-2NO-1NC-24DC-SP (2700581)General coupling relay without test pulse filter, menor costoNon-safety-critical applications, budget limited
2986575PSR-SCP-24UC/URM/2X1/1X2 (2981838)Wide-range voltage (24VCA/CC), forced guided contactsUnstable voltage environment, higher reliability required

4.2 Cross-Brand Competitor Comparison (Functionally Equivalent)

Phoenix ModelModelo SchneiderModelo SiemensPilz ModelPrincipales diferencias
2986575Zelio SR2B121BD3TK2825-1BB40PNOZ X2.7PPhoenix more compact (17.5milímetros) with integrated FSP2 filter
Schneider/Siemens lower price; Pilz higher SIL 3 nivel
Phoenix plug-in terminals allow easier replacement
  1. Entorno de aplicación & Industry Cases

Recommended Application Scenarios

Process Industrial Automation: Safety coupling between SIS digital output signals and field devices

Machine Safety Control: Safety shutdown loops for robotics, maquinaria de embalaje, maquinaria de impresión

Process Industry: Safety interlock systems for petrochemical, farmacéutico, food & beverage industries

Fabricación de automóviles: Signal isolation and amplification for production line safety gates and emergency stop buttons

Logística & almacenamiento: Safety control loops for stackers in automated warehouses

Energy Industry: Safety shutdown control systems for wind power and PV inverters

Casos de aplicación típicos

  1. Chemical Reactor Safety Control System

Application Target: Connect PLC digital output to emergency shutdown valve actuator to realize safety state shutdown

Ventaja principal: Integrated FSP2 test pulse filter avoids false valve actuation caused by PLC self-test pulses

Safety Configuration: Redundant design with 2 SIN contactos; 1 NC contact for fault alarm

Effect: Meets SIL 2 nivel de seguridad, ensures stable reactor operation and reduces false shutdown rate by 30%

  1. Automotive Welding Robot Workstation

Application Target: Couple robot controller safety output with safety gate locking device

Ventaja principal: 17.5mm narrow body saves cabinet space; plug-in terminals simplify maintenance

Safety Configuration: 2 NO contacts parallel control safety gate lock electromagnet; 1 NC contact connected to alarm lamp

Effect: Compliant with EN ISO 13849 Gato. 1, improves production line safety and efficiency

Escenarios no recomendados

Applications requiring SIL 3 or higher: Adopt SIL 3 certified models such as 2986960

High vibration environments: Additional shockproof bracket (p.ej. Phoenix ES-Mount series) requerido

Exterior / ambientes húmedos: IP20 only for indoor dry use; outdoor installation needs protective enclosure

High voltage & high current control: Exceeding 5A/250V AC requires external contactor

  1. Wiring Diagram & Terminal Definition (Engineering Design Essential)

Diseño de terminales (Front View)

13 14 23 24 31 32 A1 A2

┌─────────────────────────────┐

│ │

│ PSR-SCP-24DC/FSP2/2X1/1X2 │

│ 2986575 │

│ │

└─────────────────────────────┘

Terminal Function Definition

Número de terminal.FunciónTipoObservaciones
A1/A2Power supply input24En DCA1=Positive, A2=Negative, reverse polarity protection
13/14Normally Open Contact 1Salida de seguridadEnable path 1, 5A@250V AC/30V DC
23/24Normally Open Contact 2Salida de seguridadEnable path 2, 5A@250V AC/30V DC
31/32Normally Closed ContactSeñal / AlarmaFault status indication, 5A@250V AC/30V DC

Typical Application Circuit (PLC Safety Output Coupling)

PLC Safety Output → [2986575] → Field Actuator

(HACER) A1/A2 13/14/23/24 (Safety Gate / Molestar)

↑ ↑

24VCC 31/32 → Alarm System

Puntos clave del cableado:

  1. Power connection: A1 to 24V DC positive, A2 to negative; stable power supply required
  2. Cableado de contacto: 13/14 y 23/24 NO contacts can be series or parallel for higher reliability
  3. Alarm wiring: 31/32 NC contacts closed normally, open under fault; connect to indicator lamp or PLC input
  4. Wiring standard: Separate safety loops from power loops; use shielded cable with single-end grounding of shield layer
  5. Selection Formula & Quick Reference Rules

Selection Mnemonic

Safety coupling PSR‑SCP,

24DC for DC power adapt,

FSP2 filter stops false act,

2NO+1NC contact set exact,

17.5mm slim saves cabinet space fact,

SIL 2 grade keeps safety intact,

Order by 2986575 exact,

Plug-in wiring easy to correct,

Test pulse blocked, shutdown perfect.

Quick Reference Rules

  1. Coincidencia de voltaje: Select 24DC for DC system or 24UC for wide-range voltage
  2. Configuración de contacto: XNO+YNC — X = enable paths (1-5), Y = alarm contacts (1-3)
  3. Function Selection: FSP = test pulse filter; ESA = emergency stop/safety gate; URM = forced guided contacts
  4. Nivel de seguridad: FSP2 = SIL 2; FSP/ESA/URM = SIL 3
  5. Dimension Reference: 17.5mm narrow width ideal for compact control cabinets, ahorro 70% espacio de instalación
  6. Maintenance Tip: Plug-in terminals allow module replacement without rewiring, reduciendo el tiempo de inactividad
  7. Air Freight Compliance & Certification Info (International Trade Essential)

Air Freight Compliance: Built-in electromagnetic coil, no lithium battery / super capacitor. Compliant with IATA DGR Class 9 non-restricted goods, shippable as general cargo.

Certificaciones:

CE: Compliant with EN 61508, EN ISO 13849

UL: Compliant with UL 508 Industrial Control Equipment Standard

CSA: Compliant with Canadian electrical safety standards

SIL 2 Functional Safety: TÜV Rheinland certified, meets IEC 61508

ATEX: Suitable for potentially explosive atmospheres (partial models)

Environmental Certification: Cumple con la directiva RoHS, libre de plomo, mercurio, cadmium and other hazardous substances; meets REACH regulation requirements.

  1. Adquisitivo & Inventory Information
Purchasing ItemDetalles
Minimum Order Quantity1 piece
Lead TimeEstándar 7-10 dias laborables; Express 3-5 dias laborables
EmbalajeIndividual box packaging, 10 pcs per carton
Período de garantía2 years from date of purchase
Recommended Spare PartSame model or 2986960 (SIL 3 upgraded version)