PVA-KL26 Digital Signal Module - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

PVA-KL26 Digital Signal Module - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

eléctrico/

PVA-KL26 Digital Signal Module

PVA-KL26: KOPPEN & LETHEM Digital Signal Module / Relay Module The PVA-KL26 is a 12/24 VDC digital signal module / relay module manufactured by KOPPEN & LETHEM of the Netherlands. It is widely used in industrial control and marine applications, integrating a plug-in LED status indicator and RC circuit (for arc suppression and voltage transient ...

  • Detalles del producto

PVA-KL26: KOPPEN & LETHEM Digital Signal Module / Relay Module

The PVA-KL26 is a 12/24 VDC digital signal module / relay module manufactured by KOPPEN & LETHEM of the Netherlands. It is widely used in industrial control and marine applications, integrating a plug-in LED status indicator and RC circuit (for arc suppression and voltage transient protection).

Características principales

ParámetroEspecificación
ManufacturerKOPPEN & LETHEM (sometimes associated with Doedijns)
Voltaje de funcionamiento12/24 VCC (wide‑voltage design)
Funciones principalesSignal conversion, switching control, status indication
Key ComponentsPlug‑in LED indicator, RC circuit (arc suppression)
Mounting StylePlug‑in design for quick installation, removal and maintenance
Campos de aplicaciónAutomatización industrial, ship control systems, hydraulic equipment control

Ventajas del producto

  1. Intuitive Status Monitoring: LED indicator displays real-time operating status, reducing the risk of misoperation
  2. Protección de circuito: Built-in RC circuit effectively suppresses arcing and voltage transients, extending service life
  3. Fácil instalación: Plug-in design saves maintenance time and cost
  4. Adaptabilidad ambiental: Suitable for harsh industrial and marine environments

Aplicaciones típicas

The PVA-KL26 is commonly used for:

Signal conversion and control in marine automation systems

Remote control circuits for hydraulic machinery

Status monitoring and alarm systems for industrial equipment

Relay contact protection and signal amplification

Notas

  1. Ensure the supply voltage is within 12-24 VDC to avoid overvoltage damage
  2. Observe correct polarity during installation to prevent damage to the LED indicator and internal circuits
  3. The RC circuit must be matched to the load for optimal arc suppression
  4. For use in dry, dust-free environments only; additional protection is required in humid conditions

PVA-KL26 Detailed Technical Specification Manual

(KOPPEN & LETHEM Digital Signal / Relay Module)

The PVA-KL26 is a 12/24 VDC digital signal module / relay interface module specially designed by KOPPEN & LETHEM (Países Bajos) for industrial and marine environments. It integrates status indication and arc suppression functions, ideal for signal conversion and control under harsh operating conditions.

  1. Parámetros eléctricos básicos
ParámetroValorObservaciones
Voltaje de funcionamiento12/24 VCC (wide‑voltage compatible)Polarity protection, reverse‑connection resistant
Control Input Signal24 VDC logic levelCompatible with standard PLC digital outputs
Calificación de contacto2 A @ 24 VCC / 1 A @ 250 VACACIONESCarga resistiva; derate for inductive loads
LED IndicatorPlug‑in red LEDLights up when powered, clear status visibility
RC Arc Suppression CircuitBuilt‑in standard RC networkSuppresses contact arcing and voltage transients, extends contact life
Resistencia de aislamiento≥ 100 MΩ (en 500 VCC)Between input‑output‑ground
Rigidez dieléctrica1500 VAC for 1 minutoBetween input‑output‑ground
Consumo de energía< 1 W.Low power, suitable for continuous operation
  1. Mecánico & Características físicas
ParámetroValorObservaciones
MontajeEstándar 35 mm montaje en carril DINSnap‑in design for easy installation/removal
Module DimensionsW. 22.5 mm × H 90 mm × D 60 milímetrosStandard DIN rail module size
PesoAprox.. 80 gramoLigero, ahorra espacio en el gabinete
Connector TypePlug‑in terminal blockAccepts 2.5 mm² wire, tool‑free wiring
Protección de ingresoIP20For indoor control cabinet use
Material de la carcasaFlame‑retardant ABS plasticUL94 V‑0 rated, high fire resistance

III. Ambiental & Condiciones de funcionamiento

ParámetroValorObservaciones
Temperatura de funcionamiento−25 °C ~ +70 °CWide temperature range for marine/industrial use
Temperatura de almacenamiento−40 °C ~ +85 °CSafe storage under extreme temperatures
Humedad relativa5% ~ 95% (non‑condensing)Adaptable to high‑humidity marine environments
Vibración & ChoqueIEC 60068‑2‑6 / IEC 60068‑2‑27Complies with marine and industrial anti‑vibration standards
CEMEN 55011 / EN 61000‑6‑2Immune to electromagnetic interference, suitable for industrial automation
  1. Pin Configuration & Wiring Definition

(Standard 6-pin terminal block)

Pin No.Function DefinitionWiring Description
1V+ (Positive Power)Connect to 12/24 VDC positive
2V− (Negative Power)Connect to 12/24 VDC negative / Tierra
3IN (Signal Input)Connect to control signal (24 VDC active high)
4COM (Común)Relay contact common terminal
5NO (Normalmente abierto)Closed when relay is energized
6CAROLINA DEL NORTE (Normalmente cerrado)Closed when relay is de‑energized
  1. Detailed Functional Features
  2. Arc Suppression Technology

Built-in RC snubber circuit (estándar: 100 Oh / 0.1 μF) absorbs back EMF from inductive loads at contact break, effectively suppressing arcing and extending contact life by 3-5 veces.

  1. Status Monitoring System

Red LED provides real-time module status indication

Simple fault diagnosis: LED off = power fault; LED on but no contact action = internal circuit fault

  1. Diseño de seguridad

Polarity protection prevents damage from reverse power connection

Overcurrent protection guards against output short circuits

Surge voltage suppression protects internal electronic components

  1. Application Limitations & Notas

Load Type Adaptation

Cargas inductivas (motores, válvulas solenoides): recommended derating to 50% of rated value

Capacitive loads (condensadores, lámparas): current-limiting resistor required to prevent inrush current

Especificaciones de instalación

Avoid installation near heat sources (> 70 °C)

Maintain at least 5 mm clearance around the module for heat dissipation

Ensure secure wire crimping during wiring to prevent poor contact

Pautas de mantenimiento

Regularly check LED status and terminal tightness

Insulation test recommended every 6 months in harsh environments

Replace the entire module if faulty; internal repair is not recommended

VII. Modelos alternativos & Compatibilidad

Modelo alternativoMarcaCompatibility Description
PVA‑KL26‑EXKOPPEN & LETHEMIntrinsically safe version for hazardous areas
RM22UA02Electricidad SchneiderFuncionalmente compatible, slight dimensional differences
DILM25‑10siemensHigher contact capacity, usable as alternative

PVA-KL26 Standard Pin / Terminal Configuration

This module uses a 6-pin plug-in screw terminal block.

When facing the front of the module with terminals downward, terminal numbers are 1 a 6 from left to right.

Terminal No.MarkingDescripción de la función
1IN+Positive digital control signal input (24 VCC)
2IN−Negative signal input / common ground
3V+Positive operating power (12/24 VCC)
4V−Negative operating power / Tierra
5NONormally open relay output contact
6COMRelay contact common terminal

Important Notes

  1. This model has only NO (normalmente abierto) contactos, no NC (normalmente cerrado)
  2. Input with reverse polarity protection; LED lights when IN+ is active
  3. Built-in RC snubber on output allows direct driving of inductive loads such as solenoids and coils
  4. Terminal suitable wire cross-section: 0.5-2.5 mm²