Schneider Electric REL52002C

Schneider Electric REL52002C (Easergy P3U30 Universal Protection Relay) REL52002C is a universal digital integrated protection relay from Schneider Electric’s Easergy P3U30 (formerly PowerLogic P3U30) serie. Designed specifically for medium- and low-voltage power systems, it provides comprehensive protection, medición, control, y funciones de comunicación. 1 Model Code Interpretation Code Segment Description REL Product category: Relé (protection relay) 52002 ...

  • Detalles del producto

Schneider Electric REL52002C (Easergy P3U30 Universal Protection Relay)

REL52002C is a universal digital integrated protection relay from Schneider Electric’s Easergy P3U30 (formerly PowerLogic P3U30) serie. Designed specifically for medium- and low-voltage power systems, it provides comprehensive protection, medición, control, y funciones de comunicación.

1 Interpretación del código modelo

Segmento de códigoDescripción
RELProduct category: Relé (protection relay)
52002Product series and basic configuration: Easergy P3U30 platform, 3CT/1Io/4VT/16DI/8DO/RS485
doConfiguration suffix: Entrada digital (DE) voltage class 220V AC/DC

Full corresponding order code: P3U30-5AAA3BBAC (configuración estándar)

2 Especificaciones clave & Funciones

2.1 Configuración de hardware

Entradas analógicas: 3 corrientes de fase (Connecticut) + 1 corriente residual (yo) + 4 voltajes (Vermont)

Digital inputs (DE): 16 canales, universal for 220V AC/DC

Digital outputs (HACER): 8 channels with watchdog function (reliable tripping under fault conditions)

Comunicación: RS485 (Modbus RTU); dual RJ45 Ethernet (CEI 61850) opcional

Fuente de alimentación: Wide range 48–230V AC/DC

2.2 Funciones de protección (ANSI Standards)

Tipo de protecciónANSI CodeDescripción
Protección contra sobrecorriente50/51Instantáneo / definite time overcurrent; configurable inverse‑time characteristics
Protección de falla a tierra50N/51NZero‑sequence overcurrent protection, suitable for TN/TT systems
Sobretensión / Subtensión59/27Phase‑/line‑voltage abnormality protection
Phase failure / Phase reversal46Prevents motor reverse rotation or unbalanced operation
Protección contra sobrecarga térmica49Simulates motor thermal characteristics to prevent burnout
Protección de frecuencia81Over‑/under‑frequency protection for distributed generation
Synchronism check25Ensures safe grid‑connection operation

2.3 Medición & Monitoring

Full electrical parameters: actual, Voltaje, fuerza (active/reactive/apparent), factor de potencia, frecuencia

Energy metering: four-quadrant energy accumulation, class 0.5S accuracy

Harmonic analysis: voltage/current 2nd to 31st harmonics monitoring

Event logging: 1000 events with timestamp (1 ms resolution)

Fault recording: built-in waveform capture before and after faults

3 Entorno operativo

Standards: CEI 61850, CEI 60255, GB/T 14598 and other international/national standards

Temperatura de funcionamiento: -25°C ~ +70°C (wide-temperature design)

Temperatura de almacenamiento: -40°C ~ +85°C

Humedad: 5% ~ 95% (non-condensing)

Protección de ingreso: IP20 (panel frontal), suitable for panel mounting in switchgear

Vibration resistance: CEI 60068-2-6 (5–150Hz, 0.5gramo)

Aplicaciones típicas:

Medio- and low-voltage distribution substations (10kV/0.4kV)

Industrial plant power systems

Commercial building power distribution

Renewable energy grid connection (PV, wind)

Centros de control de motores (MCC)

UPS input/output protection in data centers

4 Related Models in the Same Series (REL520xx)

ModeloMain DifferenceDI VoltageComunicación
REL52002CTipo estándar, 3CT/1Io/4VT220VRS485
REL52002tipo básico, same configuration220VRS485
REL52010CWith dual LC (current transformers)110V2LC + RS485
REL52016Ring terminals, DI 110V110VRS485
REL52020Ring terminals, DI 24V24VRS485 + CEI 61850

5 Official Ordering Information

Standard order code: REL52002C

Full configuration code: P3U30-5AAA3BBAC

Replacement reference: Can replace earlier PowerLogic P3 series protection relays

Accesorios:

Communication module: P3-COM-ETH (CEI 61850 Ethernet module)

Extension module: P3-EXT-DIO (additional DI/DO expansion)

Local HMI: P3-HMI (local human-machine interface)

6 Modelos de reemplazo & Compatibilidad

6.1 Within-series Replacements

Lower DI voltage required: REL52020 (24V DI), REL52016 (110V DI)

Extended communication: REL52025 (dual RJ45 Ethernet)

6.2 Cross-series Replacements

Advanced applications: SEPAM 20 serie (medium-voltage systems)

Economy applications: Easergy P3U20 series (configuración simplificada, 10DI/5DO)

7 Engineering Implementation Notes

  1. Montaje: Standard 4U height, 19-inch rack mounting; front-or rear-wiring optional
  2. Alambrado:

CT input: 5A/1A selectable (software configuration required)

VT input: 100V (line-to-line) / 57.7V (phase-to-neutral)

DI/DO: Phoenix terminals, screw or spring connection

  1. Commissioning:

Parameter configuration and monitoring via Easergy Studio software

Local USB and remote network debugging supported

Comprehensive self-diagnostics for easy maintenance

REL52002C is a full-featured, flexible universal protection relay suitable for protection and monitoring in various medium- and low-voltage power systems, especially industrial applications requiring 220V digital inputs and RS485 communication.

Core Parameter Comparison Table – Schneider Electric Easergy P3U30 Series (REL520xx)

1 Basic Parameter Summary

ModeloDI VoltageComunicaciónEntradas analógicasDO ChannelsFuente de alimentaciónKey Difference
REL52002C220VCA/CCRS485 (Modbus)3CT+1Io+4VT848–230V AC/DCStandard general‑purpose model, 220V DI, RS485 only
REL52002220VCA/CCRS485 (Modbus)3CT+1Io+4VT848–230V AC/DCIdentical hardware to C version, simplified suffix
REL52010C110VCA/CCRS485+2LC3CT+1Io+4VT848–230V AC/DC110V DI, dual LC transformer interfaces
REL52016110VCA/CCRS485 (Modbus)3CT+1Io+4VT848–230V AC/DC110V DI, ring‑type terminals
REL5202024En DCRS485+IEC 618503CT+1Io+4VT848–230V AC/DC24V DI, supports IEC 61850 Ethernet
REL52025220VCA/CCDual RJ45+IEC 618503CT+1Io+4VT848–230V AC/DC220V DI, dual Ethernet ports, premium communication

2 Key Selection & Replacement Rules

2.1 Voltage Class Replacement

Original model: REL52002C (220V DI)

Reemplazo directo (only DI voltage differs):

110V systems → REL52016

24V low-voltage systems → REL52020

2.2 Communication Upgrade

RS485 only: keep REL52002C

IEC 61850/Ethernet required: REL52020 / REL52025

2.3 Non-interchangeable Cases

REL52010C with 2LC interfaces is for dedicated transformer connections and not for standard panels

Terminal types differ; cabinet wiring must match ring or standard terminals

3 Common Features (Across Series)

Protección: 50/51 sobrecorriente, 50N/51N earth fault, 27/59 Voltaje, 46 phase rotation, 49 sobrecarga térmica

Metering: Class 0.5S energy, 2–31 harmonics

Logging: 1000 time-stamped events, registro de fallas

Montaje: Standard 19-inch 4U for panel installation

Software: Configured via Easergy Studio

Application Scenarios – Schneider Electric REL520xx Series

1 REL52002C (220V DI + RS485)

Most common and widely used standard model

10kV general distribution substations: feeder, incomer, bus tie, station transformer, capacitor protection

Standard MCC panels in industrial plants, motors for pumps, fans, compresores de aire

0.4kV critical circuits in commercial buildings: malls, oficinas, hoteles

Retrofit of old substations with only Modbus RTU for data upload

Municipal facilities: residential substations, streetlight power, small water pump stations

Característica: On-site 220V AC/DC control power, basic power monitoring only

2 REL52016 (110V DI + RS485)

For traditional high-voltage control circuits

Legacy substations and power plant auxiliary systems

Industria pesada: aceite, químico, metalurgia (typically 110V DC control power)

Substation retrofits: reuse existing 110V secondary cables without rewiring

Mining and heavy machinery plant distribution protection

3 REL52010C (110V DI + RS485 + 2LC)

Special transformer configuration scenarios

Custom medium-voltage switchgear with dedicated LC transformer interfaces

Special circuits with integrated metering and protection

Industrial projects with fixed CT/VT wiring requirements

Rare in general projects; custom-engineered model

4 REL52020 (24V DI + CEI 61850)

Low-voltage automation & smart grid applications

Data center UPS input/output, precision power distribution

PV and wind turbine box-type substations, energy storage grid connection

Smart microgrids and distributed generation projects

Power distribution for automated production lines linked with PLC (24V low-voltage control)

Small smart power stations requiring IEC 61850 comunicación

5 REL52025 (220V DI + Dual Ethernet IEC 61850)

High-end smart power distribution

New smart substations, main distribution in intelligent industrial parks

Rail transit (metro/high-speed rail): traction substations, distribución de energía

Critical circuits at airports, ports, large venues

High-end projects requiring network redundancy, remote O&METRO, centralized dispatching

Multi-device networking and centralized monitoring in control centers

General Industry Applications (Full Series)

Sistemas de energía: 10kV/35kV substations, switching stations, ring main units

Manufacturing: metalurgia, químico, papel, electronics, equipment production

Renewables: PV, wind power, almacenamiento de energía, EV charging clusters

Infraestructura: centros de datos, tránsito ferroviario, hospitales, schools, commercial complexes

Mining & agua: mine power, pump stations, wastewater treatment plant protection