Schneider EZD400E-3P-250A Molded Case Circuit Breaker - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

Schneider EZD400E-3P-250A Molded Case Circuit Breaker - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

cortacircuitos/

Schneider EZD400E-3P-250A Molded Case Circuit Breaker

This is a Schneider EZD series 400A frame size, 3-polo, 250Una corriente nominal, 36kA breaking capacity molded case circuit breaker. Its standard order number is EZD400E3250K. It is applied to overload and short-circuit protection in secondary power distribution systems, featuring cost performance and installation flexibility. Model Segment Definition Model Segment Meaning Description EZD Product Series ...

  • Detalles del producto

Este es un Schneider EZD series 400A frame size, 3-polo, 250Una corriente nominal, 36kA breaking capacity molded case circuit breaker. Its standard order number is EZD400E3250K. It is applied to overload and short-circuit protection in secondary power distribution systems, featuring cost performance and installation flexibility.

  1. Model Segment Definition
Segmento de modeloSignificadoDescripción
EZDSerie de productosSchneider EasyPact EZD molded case circuit breaker series, designed for secondary power distribution, civil buildings and electromechanical markets
400Marco actual400A frame size, maximum rated current up to 400A
miClase de capacidad de rupturaClass E, 36kA @ 400V AC, suitable for general industrial and civil building power distribution
3PAGNúmero de polo3-polo, sistema trifásico de tres hilos
250ACorriente nominalThermal-magnetic trip unit rated current 250A with fixed protection setting values
kTipo de montajetipo fijo / front connection (estándar); PK means plug-in type
  1. Core Specification Parameter Table
Categoría de parámetroEspecificación detalladaObservaciones
Parámetros básicos
Marca & ModeloSchneider EZD400E3250KStandard order number
Tensión nominal400V y (máx.. 690V y)50/60Hz
Tensión nominal de aislamiento1000V yCumple con IEC 60947-2
Corriente nominal (En)250AThermal-magnetic trip TM250D
Número de polo3PAGTrifásico de tres hilos.
Capacidad de ruptura (uci)36kA @ 400V ACClass E breaking capacity
Características de protección
Tipo de unidad de disparoThermal-Magnetic (TMD)Long time delay for overload + protección instantánea contra cortocircuitos
Protección contra sobrecarga1.05En: No tripping continuouslyCumple con IEC 60947-2
1.30En: Tripping within ≤1 hour
6.00En: Tripping within ≤2 seconds
Protección contra cortocircuitosInstant trip at ≥10InProtect lines and equipment from overload and short-circuit damage
Mecánico & Parámetros de instalación
Tipo de montajeFijado (Estándar) / Plug-in optionalUpper/lower incoming line interchangeable without derating
Método de cableadoCableado frontal (Estándar)Rear wiring and plug-in wiring optional
Modo de operaciónOperación manual (Handle)Ergonomic design, labor-saving operation
Dimensión general (Ancho×Alto×Profundidad)140×255×110 mmStandard dimension for 400A frame
PesoAprox.. 4.5 kilos
Mounting PositionVertical / Horizontal / Side / RearPerformance unaffected by mounting position
Parámetros ambientales
Temperatura de funcionamiento-5℃ ~ +40℃Derate above 40℃
Temperatura de almacenamiento-25℃ ~ +70℃
Grado de protecciónIP30 (Solo cuerpo)IP40 with protective cover
Proceso de dar un título
Cumplimiento de estándaresCEI 60947-2, ES 14048.23C Certificate No.: 2020980307…
  1. Lista de accesorios (Compatible with EZD400 Series)
Accessory TypeModelo / Número de pedido.Descripción de la función
Contacto auxiliarEZ4OF101 (Single Auxiliary)Indicate breaker ON/OFF status (DE), 1NO/1NC or 2NO/2NC
EZ4OF201 (Dual Auxiliary)
Alarm ContactEZ4SD101 (Single Alarm)Indicate breaker tripping status (SD), including fault and non-fault tripping
EZ4SD201 (Dual Alarm)
Viaje de derivaciónEZ4SHT200ACDCZ (CA 220 V.)Remote trip control, fire emergency trip application
EZ4SHT400ACZ (CA380V)
EZ4SHT048ACDCZ (CC 24 V)
Liberación de subtensiónEZ4MN200ACZ (CA 220 V.)Automatic trip when voltage below set value, protect equipment from over/undervoltage damage
EZ4MN400ACZ (CA380V)
Extended Rotary HandleEZ4H100Convenient door operation, suitable for distribution cabinet installation
Interphase BarrierEZ4SP400Enhance interphase insulation and safety
BusbarDedicated busbar systemSuitable for multi-circuit outgoing lines, easy installation and neat layout
Plug-in BaseEZ4B400Adapt to plug-in mounting for easy maintenance and replacement
  1. Alternativa & Comparación entre marcas

4.1 Schneider Internal Series Replacement

SerieModeloCapacidad de rupturaTipo de viajeGama de preciosEscenario de aplicación
EZDEZD400E3250K36elThermal-MagneticMedio-bajoGeneral power distribution, prioridad de costos
CVSCVS400N325050elThermal-Magnetic / ElectrónicoMedioIndustrial distribution, higher breaking capacity required
NSXNSX400N325050el / 70elElectrónico (micrológico)AltoHigh-end distribution, precise protection and communication required

4.2 Cross-Brand Competitor Comparison

MarcaModeloMarco / Corriente nominalCapacidad de rupturaPrice RatioCaracterísticas
chintNXM-400S/3300 250A400A / 250A36elAcerca de 60% of EZDAlternativa doméstica, rendimiento de alto costo
TEJIDOTmax T4N250400A / 250A50elAcerca de 120% of EZDStrong breaking capacity, stable performance
siemens3VT400N250400A / 250A36elAcerca de 110% of EZDCompatible with Siemens system, funciones de comunicación completas
Interruptor ChangshuCM3-400M/3300 250A400A / 250A36elAcerca de 70% of EZDHigh-quality domestic brand, buena compatibilidad
  1. Puntos clave de selección & Soluciones alternativas

5.1 Core Selection Guidelines

Coincidencia de tipos de carga

Distribution Protection: EZD400E series (thermal-magnetic), suitable for lighting, socket and non-motor loads

Protección de motores: Recommend EZD400M series (motor protection type with higher short-circuit trip multiple)

Protección de corriente residual: Adopt VigiEZD400E series with integrated residual current protection

Breaking Capacity Selection

36el (Class E): industrias generales & civil buildings with low short-circuit current

50el (Class M): Industrial environments with high short-circuit current, such as near inverters and large motors

Calculation Rule: Select proper breaking capacity based on system short-circuit current calculation

Mounting Type Decision

Fixed Type: Bajo costo, for circuits without frequent replacement

Tipo de complemento: Fácil mantenimiento, for important circuits requiring quick replacement (data center, hospital)

5.2 Recommended Alternative Solutions

GuiónRecommended SolutionVentajas
Budget Limited, General DistributionChint NXM-400S/3300 250APrecio bajo, meets basic performance requirements
High Breaking Capacity Required (50el)Schneider CVS400N3250Same-brand upgrade, installation dimension compatible, mayor capacidad de rotura
Protección precisa & Communication NeededSchneider NSX400N3250 + micrológico 2.3Electronic trip with adjustable parameters, support Modbus communication
Residual Current Protection NeededVigiEZD400E3250KProtección de corriente residual integrada, save space without extra module
Remote Control NeededEZD400E3250K + Viaje de derivación + Contacto auxiliarRealize remote tripping and status monitoring, fit intelligent distribution system
  1. Key Operation Precautions
  2. Derating Application: Derate rated current by 1% per 1℃ above 40℃; reducir por 0.5% per 100m altitude over 1000m.
  3. Especificación de cableado: Follow top-in bottom-out rule; fasten terminals to avoid overheating. 3P for three-phase three-wire; select 4P if neutral protection is needed.
  4. Instalación de accesorios: Auxiliary/alarm contacts, shunt/undervoltage releases can be field-installed; cut off power before installation for safety.
  5. Ciclo de mantenimiento: Inspect every 6 months including appearance, mechanism flexibility and terminal tightness.
  6. Manejo de fallas: después de tropezar, identify cause (overload/short-circuit), eliminate fault then close again.

Complete Model List of Schneider EZD Series Circuit Breakers

Overview: The EZD series covers 5 frame sizes (100A/160A/250A/400A/630A), 3 breaking classes (E=25kA, N=36kA, M=50kA), 2 pole types (3P/4P), 2 trip types (TMD thermal-magnetic / ETU electronic; electronic only for 630A frame), 2 mounting types (Fixed N / Plug-in PK), plus residual current type (VigiEZD) and motor protection type (MAMÁ) variants.

  1. Regla de nomenclatura del modelo (Básico)
Segmento de modeloSignificadoOptional ValueDescripción
EZDSerie de productosEZDEasyPact EZD molded case circuit breaker series
100/160/250/400/630Marco actual100/160/250/400/630Maximum rated current capacity
E/N/MCapacidad de rupturami(25el), norte(36el), METRO(50el)Ultimate breaking capacity @400V AC
3-4Número de polo3(3PAG), 4(4PAG)3P=3-phase 3-wire; 4P=3-phase 4-wire
0XX/XX0Corriente nominal15~630ARated current of thermal-magnetic trip unit
N/PKTipo de montajenorte(Fijado), PK(Complemento)Fixed as standard; PK for plug-in
MAMÁTipo de aplicaciónMAMÁ(Protección de motores)Non-MA for distribution protection
EL/ELAResidual CurrentEL(30mamá), ELA(300mamá)Exclusive for VigiEZD series
  1. Complete Model List by Frame Size

2.1 EZD100 Frame (máx.. 100A)

2.2 EZD160 Frame (máx.. 160A)

2.3 EZD250 Frame (máx.. 250A)

2.4 EZD400 Frame (máx.. 400A)

2.5 EZD630 Frame (máx.. 630A, with Electronic Trip)

  1. Residual Current Protected Type (VigiEZD Series)
  2. Key Selection Instructions
  3. Common Model Quick Reference (Distribution Protection)
  4. Accessory Compatibility Guide

Anterior:

Deja una respuesta