Siemens 3VA9267-0HA20 Molded Case Circuit Breaker - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

 Siemens 3VA9267-0HA20 Molded Case Circuit Breaker - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

cortacircuitos/

Siemens 3VA9267-0HA20 Molded Case Circuit Breaker

Model Code Interpretation Segment 3VA 9 267 -0HA 20 Meaning Product series: SENTRON 3VA molded case circuit breaker system Accessory category: 3VA9 series accessories Accessory type: MO320 Front-mounted Motor Operator Control voltage code: 110-230V y / 110-250V DC Applicable breaker rating: 3VA2 100/160/250A Description Flagship low-voltage power distribution series of Siemens, covering MCCBs from 16A ...

  • Detalles del producto

Interpretación del código modelo

Segmento3Virginia9267-0HA20
SignificadoSerie de productos: SENTRON 3VA molded case circuit breaker systemAccessory category: 3VA9 series accessoriesTipo de accesorio: MO320 Front-mounted Motor OperatorControl voltage code: 110-230V y / 110-250En DCApplicable breaker rating: 3VA2 100/160/250A
DescripciónFlagship low-voltage power distribution series of siemens, covering MCCBs from 16A to 1600AAccessory system specially designed for 3VA series circuit breakersMO320 motor operator, supporting remote closing and trippingDiseño de amplio voltaje, compatible with various power supply systemsSuitable for 3VA2 circuit breakers rated at 100A, 160A and 250A
  1. Especificaciones técnicas principales
Categoría de parámetroDatos técnicosObservaciones
Información general
Nombre del productoMO320 Front-mounted Motor OperatorFor 3VA2 series molded case circuit breakers
Número de pedido.3VA9267-0HA20Standard commercial model
Estado del productoActivo (PM300)Defined by Siemens Product Lifecycle Management System
Parámetros eléctricos
Voltaje de control110-230V y (50/60Hz) / 110-250En DCAmplia compatibilidad de voltaje
Rated Apparent Power250VirginiaPower consumption of the operator
Tiempo de funcionamiento (Cierre & Tropezar)Típico 1 segundoMechanical response time
Parámetros mecánicos
Dimensiones (Ancho×Alto×Profundidad)105mm×75mm×132mmCompact design to save cabinet space
PesoAprox.. 846gramoEasy for installation and maintenance
Terminal CapacityFor 1.5-2.5mm² conductorsSólido, stranded and fine-stranded conductors applicable
Wire Stripping Length7milímetrosCumple con los estándares IEC
Par de apriete0.36-0.44Nuevo MéjicoEnsure reliable connection
Parámetros ambientales
Temperatura de funcionamiento-25°C a +70°CSuitable for industrial environments
Temperatura de almacenamiento-40°C a +80°CWide temperature range for storage
Protección de ingresoIP30Cumple con IEC 60529
  1. Full Range of MO320 Motor Operators
ModeloVoltaje de controlApplicable Breaker SeriesObservaciones
3VA9267-0HA1024-60En DC3VA2 100/160/250Low voltage DC type
3VA9267-0HA20110-230V y / 110-250En DC3VA2 100/160/250Universal wide voltage type (Current Model)
3VA9157-0HA1024-60En DC3VA1 100/160For 3VA1 series
3VA9157-0HA20110-230V y / 110-250En DC3VA1 100/160For 3VA1 series
3VA9467-0HA1024-60En DC3VA2 400/630For high-current 3VA2 breakers
3VA9467-0HA20110-230V y / 110-250En DC3VA2 400/630For high-current 3VA2 breakers
3VA9257-0HA1024-60En DC3VA2 100/160Side-mounted type
3VA9257-0HA20110-230V y / 110-250En DC3VA2 100/160Side-mounted type
  1. Competidor & Equivalent Model List
MarcaModeloApplicable BreakerVoltaje de controlDescripción de reemplazo
siemens3VA9267-0HA103VA2 100/160/25024-60En DCLow-voltage alternative within the same series
Electricidad SchneiderLV432642NSX 400-630380-415V yFunctional cross-brand replacement
TEJIDOCD2-400T1-T6 Series220VCA/CCFunctional cross-brand replacement
TEJIDOOTM-D250Serie Tmax24-250VCA/CCFunctional cross-brand replacement
EatonNZM-E200NZM Series24-230VCA/CCFunctional cross-brand replacement
  1. Entornos de aplicación & Casos de la industria

5.1 Recommended Application Scenarios

Sistemas de automatización industrial: Remote closing and tripping of motor circuits for production line automatic control

Centros de datos: Remote operation of breakers for UPS systems to improve power supply reliability

Edificios Comerciales: Remote control of breakers for emergency lighting and fire protection systems, complying with safety regulations

Infraestructura Energética: Remote monitoring of breakers for photovoltaic inverters and energy storage systems to boost operation efficiency

Water Treatment Facilities: Automatic switching of pump circuits to realize unattended operation

5.2 Non-recommended Scenarios

Explosive Hazardous Areas: Additional explosion-proof certification is required; not suitable for direct use in IIC explosive zones

High Electromagnetic Interference Environments: Extra electromagnetic shielding is needed; not recommended near unshielded high-frequency equipment

Severe Vibration Environments: Not applicable where vibration acceleration exceeds 5g, which may impair mechanical reliability

5.3 Casos de aplicación típicos

Caso 1: Automobile Manufacturing Plant

Solicitud: Remote control of power circuits for welding robots

Configuración: 3VA2 250A MCCB + 3VA9267-0HA20 Motor Operator + PLC Control System

Beneficios: Realize automatic power-off protection for production lines, reduce manual operation and increase productivity by 15%

Caso 2: Large-scale Data Center

Solicitud: Remote management of Power Distribution Units (PDU) in server cabinets

Configuración: 3VA2 160A MCCB + 3VA9267-0HA20 + Building Management System (BMS)

Beneficios: Remote monitoring and circuit switching, quick fault isolation; Mean Time To Repair (MTTR) reduced to less than 5 minutos

Caso 3: Hospital Operating Room

Solicitud: Emergency control of dedicated power circuits for medical equipment

Configuración: 3VA2 100A MCCB + 3VA9267-0HA20 + Emergency Control System

Beneficios: Fast power switching for operating rooms, ensure safe operation of medical devices; Cumple con IEC 60601 medical standards

  1. Consejos de selección & Quick Reference Rules

Selection Rhythm (For Reference)

Model 3VA9267-0HA20,

Cubiertas 110 to 230V AC/DC,

Matches 3VA2 100/160/250A breakers,

Front-mounted MO320 design,

One second for remote switch action,

Rated power at 250VA,

Dimension 105×75×132mm,

Ideal for industrial and building applications.

Quick Reference Rules

  1. Coincidencia de voltaje: HA20 = Wide voltage (110-230V y / 110-250En DC); HA10 = Low voltage (24-60En DC)
  2. Serie aplicable: 9267 = 3VA2 100/160/250A; 9157 = 3VA1 100/160A; 9467 = 3VA2 400/630A
  3. Tipo de montaje: 9267 = Front-mounted; 9257 = Side-mounted
  4. Parámetros principales: 1-second operating time, 250VA power rating, compatible with 1.5-2.5mm² conductors
  5. Solución de problemas & Soluciones
Fenómeno de fallaPosibles causasSoluciones
Failure to close or tripAbnormal control voltageVerify the voltage is within 110-230V AC / 110-250En DC
Terminales de cableado flojosRetighten terminals with torque of 0.36-0.44N·m
Atasco mecánicoCheck connection between operator and breaker, eliminar objetos extraños
Slow closing/trippingInsufficient power supply capacityEnsure control circuit power ≥ 250VA
Excessively low ambient temperatureApply heating measures when temperature is below -25°C
Excessive operating noiseMechanical wearInspect transmission parts and replace grease if necessary
Unstable installationRe-fix the operator and ensure flat mounting surface
  1. Key Features Summary
  2. Amplia compatibilidad de voltaje: 110-230V y / 110-250En DC, reducing spare parts stock and procurement costs
  3. Respuesta rápida: Typical 1-second operating time, meeting emergency control requirements
  4. Estructura compacta: Dimension 105×75×132mm, saving space inside switchgear cabinets
  5. Alta confiabilidad: Operating temperature range from -25°C to +70°C, adaptable to harsh industrial conditions
  6. Fácil instalación & Mantenimiento: Standard interface for perfect matching with 3VA2 series breakers

Typical Application Cases of Siemens 3VA9267-0HA20 (MO320 Motor Operator)

This accessory is designed for 3VA2 100/160/250A molded case circuit breakers to realize remote motorized closing and tripping. With control voltage of 110–230V AC / 110–250 VCC, it is widely applied in industrial, centro de datos, building and energy sectors.

  1. Automobile Welding Workshop (Automatización Industrial)

Configuración: 3VA2 250A + 3VA9267-0HA20 + SOCIEDAD ANÓNIMA / Fieldbus System

Solicitud: Remote switching and automatic fault isolation for power circuits of welding robots and welders

Beneficios: Minimize manual work, improve workshop safety; cut downtime via remote power-off during faults

  1. Large-scale Data Center (Infraestructura)

Configuración: 3VA2 160A + 3VA9267-0HA20 + BMS / EMS

Solicitud: Centralized remote control for cabinet PDUs, UPS outputs and precision air conditioners

Beneficios: Remote inspection and circuit operation, rapid fault location and isolation; wide voltage design compatible with global mains power

  1. Commercial Complex & High-rise Buildings (Smart Power Distribution)

Configuración: 3VA2 100–250A + 3VA9267-0HA20 + Fire Alarm / BAS System

Solicitud: Interlocked control for emergency lighting, fire pumps and exhaust fans; remote power cut for energy saving during off-hours

Beneficios: Comply with mandatory fire power cut regulations; lower operation costs and improve energy efficiency

  1. fotovoltaica & Energy Storage Power Stations (Nueva energía)

Configuración: 3VA2 250A + 3VA9267-0HA20 + Power Station Monitoring System

Solicitud: Remote grid connection/disconnection and fault protection for AC sides of inverters and energy storage cabinets

Beneficios: Adapt to wide outdoor temperature (-25°C a +70°C); realize remote operation and reduce on-site inspection work

  1. Hospital Operating Room & UCI (Medical Power Supply)

Configuración: 3VA2 100A + 3VA9267-0HA20 + Medical Isolated Power System

Solicitud: Emergency switching and protection for surgical equipment and life support systems

Beneficios: Fast switching (aprox. 1 segundo), high operational reliability and compliance with medical power supply standards

  1. Tratamiento de agua & Pumping Stations (Municipal Engineering)

Configuración: 3VA2 160–250A + 3VA9267-0HA20 + Pump Station PLC

Solicitud: Remote start/stop and overload protection for submersible pumps, blowers and chemical dosing equipment

Beneficios: Suitable for humid and dusty environments; unattended remote control to reduce operation costs

Puntos centrales de coincidencia

Applicable Breakers: 3VA2 100/160/250A (3-polo / 4-polo)

Voltaje de control: 110–230V AC / 110–250 VCC (Universal wide voltage)

Tipo de montaje: Front-mounted (MO320), Dimensión: 105×75×132mm

Key Functions: Remote closing & tropezar, fault isolation; adecuado para industrias, building and new energy applications