Schneider LC1E630U7 AC Contactor

The domestic full model designation is commonly LC1E630U7N. Discontinued in April 2021. It is a 3-pole high-power AC contactor. ✅ Model Code Definition LC1E: EasyPact TVS AC contactor series 630: AC-3 rated operational current of 630 A U: voltaje de la bobina 240 V y 7: 50/60 Hz universal AC coil N: Domestic version with CCC certification ...

  • Detalles del producto

The domestic full model designation is commonly LC1E630U7N. Discontinued in April 2021. It is a 3-pole high-power AC contactor.

✅ Definición del código del modelo

LC1E: EasyPact TVS AC contactor series

630: AC-3 rated operational current of 630 A

Ud.: voltaje de la bobina 240 V y

7: 50/60 Hz universal AC coil

norte: Domestic version with CCC certification (Overseas model LC1E630U7 does not carry suffix N)

This unit has no built-in auxiliary contacts. Auxiliary contacts require add-on accessories.

📋 Especificaciones eléctricas básicas

ArtículoParámetro
Número de polos3PAG, 3SIN contactos principales
Utilisation categoryAC-3 (motor loads), AC-1 (cargas resistivas)
AC-3 Ie630 A (@ ≤440 V, 55 °C)
AC-1 Ith1000 A (@ 40 °C)
Tensión nominal de aislamiento Ui690 V
Tensión nominal soportada al impulso Uimp8 kV
Coil rated voltage Uc240 V y, 50/60 Hz
Coil operating rangeLevantar: 0.85~1.1 × Uc; Abandonar: 0.25~0.5 × Uc
Inrush power consumption1650 Virginia; Hold power consumption: 22 Virginia
Potencia de motor compatible220 V: 185 kilovatios 380/400 V: 335 kilovatios 440 V: 400 kilovatios 690 V: 450 kilovatios
Rated short-time withstand current Icw5050 A / 10 s
Making / Capacidad de rupturaMaking: 6300 A; Rotura: 5040 A @440 V

🛠 Mechanical & Endurance Characteristics

Resistencia mecánica: 4 millones de ciclos

AC-3 electrical endurance: 600,000 ciclos; AC-1: 200,000 ciclos

Maximum operating rate: 1200 ciclos/hora

tiempo de funcionamiento: Closing 40~80 ms; Opening 100~200 ms

Montaje: Plate mount (high-current frame does not support standard DIN rail)

Par de apriete: Circuito principal 58 Nuevo Méjico; circuito de control 1.2 Nuevo Méjico

Dimensión general: W309 × H304 × D255 mm; Peso neto: 18.6 kilos

Clase de protección: IP00

Temperatura ambiente de funcionamiento: -5 ~ +55 °C; No derating up to altitude 3000 metro

📌 Typical Applications

ventiladores de alta potencia, bombas de agua, compresores de aire, trituradoras, large motor starter cabinets, low-voltage switchgear; AC-3 squirrel-cage motor start-stop control, switching of heavy resistive loads.

⚠️ Discontinuation & Opciones de reemplazo

LC1E630U7N discontinued in April 2021, no new original production. Stock / second-hand units available on market.

  1. Schneider OEM replacement: LC1G630KUEC (TeSys Giga series, 630 A, 240 VAC compatible coil)
  2. Alternativa doméstica: CJX2-F630, NC2-630, etc.. (Verificar el voltaje de la bobina, temperature rise and short-time withstand current)

🧰 Optional Accessories

Auxiliary contact block: LA1KN (add-on 1NO+1NC)

Coil surge suppressor, enclavamiento mecánico, terminal shroud, relé de sobrecarga térmica (large frame LRD series)

📎 Inspection Checklist for Second-hand Acceptance

  1. Measure coil resistance and compare with reference value for same model; power on to test pull-in / drop-out, sin pegajosidad ni ruidos anormales
  2. Inspect main contact surface for ablation or welding; check consistency of contact resistance across three phases
  3. Dielectric strength test: 2.5 kV / 1 min between phases and main circuit to earth
  4. Verify terminal tightening torque; inspect busbar contact surface for oxidation and overheating discoloration
  5. Test operating voltage: Reliable pull-in at 0.85Uc, reliable drop-out below 0.5Uc

LC1G630KUEC VS LC1E630U7 Parameter Comparison Table

LC1E630U7: EasyPact TVS, interrumpido; LC1G630KUEC: TeSys Giga, OEM replacement. KU = 100~250 V AC/DC wide-range coil (compatible with original 240 VACACIONES).

ParámetroLC1E630U7LC1G630KUECObservaciones
Serie de productosEasyPact TVS (Easy TeSys)TeSys GigaSchneider new generation high power contactor
Model definition3PAG, AC-3 630 A, bobina 240 V y, 50/60 Hz3PAG, AC-3 630 A, 100~250 V AC/DC wide coilGiga AC/DC universal coil, direct replacement for U7 (240VACACIONES) without control circuit modification
Product statusDiscontinued Apr 2021, existencias / second-handIn production, genuine new
polacos / Contactos principales3PAG, 3NO3PAG, 3NO
AC-3 rated Ie @≤440V630 A (55 °C)630 AIdentical rating for motor loads
AC-1 conventional thermal current Ith @40 °C1000 A1050 AGiga higher resistive load capacity
Tensión nominal de aislamiento Ui690 V1000 VGiga upgraded insulation
Tensión nominal soportada al impulso Uimp8 kV8 kVIdéntico
Rated short-time withstand current Icw5050 A /10 s5050 A /10 s; 4400 A /30 sSame 10s withstand; Giga superior long-duration withstand
Making capacity @440V6300 A7220 AGiga higher short-circuit making capability
Breaking capacity @440V5040 A5550 A
Contactos auxiliares incorporadosNinguno, LA1KN add-on required1NO+1NC built-inNo need to purchase auxiliary contact block for retrofit
Tipo de bobinaAC only, 240 V, 50/60 HzWide-range AC/DC 100~250 VCompatible with AC and DC control supply, better engineering flexibility
Coil operating rangePull-in:0.85~1.1Uc Drop-out:0.25~0.5UcPull-in:0.8~1.1Ucmin~Ucmax Drop-out: ≤0.45UcWider voltage tolerance for grid fluctuation
Consumo de energía de la bobinaIrrupción 1650 Virginia; Hold 22 VirginiaIrrupción 800 Virginia; Hold 15 VirginiaMuch lower coil power, less cabinet heat
Resistencia mecánica4 millones de ciclos5 millones de ciclos25% mejora
AC-3 electrical endurance600,000 ciclos1 millones de ciclosSignificant improvement under motor duty
Maximum operating rate1200 ciclos/horaAC-3: 600 ciclos/horaLC1E better for frequent cycling; LC1G sufficient for standard motor applications
tiempo de funcionamientoClose 40~80 ms; Open 100~200 msClose 40~70 ms; Open 15~50 msGiga faster opening
Temperatura ambiente-5 ~ +55 °C-25 ~ +60 °CGiga supports low-temperature startup
Clase de protecciónIP00IP2X with shroudFinger-safe protection
Dimensión(Ancho×Alto×Profundidad)309 × 304 × 255 milímetros211 × 284 × 266 milímetros~32% narrower, ahorra espacio en el gabinete
Peso neto18.6 kilos14.2 kilos4.4 kg lighter for easier handling
Main circuit tightening torque58 Nuevo Méjico58 Nuevo MéjicoBusbar torque unchanged, busbars can be reused
Control circuit torque1.2 Nuevo MéjicoPush-in spring terminalTool-free control circuit connection
MontajePlate mountPlate mountMounting hole pattern incompatible, base plate re-drilling required
Power dissipation per pole (AC-3)48 W.26 W.Lower contact loss, less temperature rise
Motor power AC-3 @400V335 kilovatios335 kilovatiosIdentical motor rating
Extra featuresBasic contactorOptional contact wear diagnosis, enclavamiento mecánico, comentarios de estadoPredictive maintenance available for critical loads

✅ Replacement Summary

  1. Main circuit rating fully equivalent: Adecuado para 335 kilovatios, 400 V motor. Keep busbar torque at 58 Nuevo Méjico; Mounting hole layout differs, base plate re-drilling required.
  2. Control circuit advantage: LC1G630KUEC wide-range 100~250 V AC/DC coil works directly with original 240 VAC control supply; lower coil power and built-in 1NO+1NC auxiliary contacts, no auxiliary accessory purchase.
  3. Limitación: Max operating rate reduced to 600 ciclos/hora. Applications with frequent inching or high cycle count need evaluation.
  4. Temperature rise & fiabilidad: Giga higher insulation voltage, lower contact loss and wider ambient temperature range, ideal for critical continuous-duty loads.

⚠️ Engineering Replacement Risk Notes

Original 240 V AC control supply can connect directly to LC1G630KUEC coil.

Do not replace directly for heavy inching / marcha atrás frecuente >600 ciclos/hora; performance review mandatory.

Much narrower frame width; existing busbars and protective baffles need rework.

LC1G630KUEC (TeSys Giga) Industria & Load Application Guide

LC1G630KUEC: AC-3 630 A, rated for 335 kW three-phase squirrel cage motor at 400 V. Built-in contact wear diagnosis, wide-range AC/DC coil and IP2X shroud. Designed for high-power motor start-stop, star-delta starters and heavy resistive load switching. Max operating rate 600 ciclos/hora, not recommended for high-frequency inching.

🏭 1. Agua & Aguas residuales (Waterworks, Sewage Plants, Pumping Stations)

Typical loads: Large raw water pumps, bombas elevadoras de aguas residuales, circulating pumps, sludge pumps, sopladores de aireación, main drive motors for scrapers.

Características: 24/7 continuous operation requiring high reliability. LC1G supports -25 °C low temperature operation and contact wear diagnosis for predictive maintenance. Widely used in MCC pump cabinets and the most common retrofit candidate replacing LC1E630U7.

🌬️ 2. Large HVAC, Centros de datos & Commercial Complexes

Typical loads: Chiller compressors, large cooling tower fans, primary / secondary chilled water pumps, building exhaust fans.

Características: Building MCC switchgear, frequent start-stop and elevated cabinet ambient temperature. Giga Ui=1000 V high insulation and low temperature rise; wide coil accommodates building supply voltage fluctuation.

⚙️ 3. Metalurgia, Minería & Materiales de construcción

Typical loads: Trituradoras, molinos de bolas, heavy belt conveyors, kiln blowers, hoist motors (derating required for AC-4 duty).

Características: Heavy shock loads and dusty harsh environment; strong short-time withstand and short-circuit capacity. AC-4 hoist duty limited to max 150 ciclos/hora, derating mandatory during selection.

🛢️ 4. Petroquímico & Energía (Aceite & Gas, Solar, Energía eólica)

Typical loads: Process pumps, compresores, thermal oil furnace blowers, wind turbine yaw / pitch large motors, high-power resistive load switching for PV systems.

Características: Mounted outside explosion-proof enclosures, prone to supply voltage fluctuation. Wide-range 100~250 V AC/DC coil with high control supply compatibility; Marine certification available for auxiliary motor circuits on offshore platforms.

📦 5. Papel, Pulpa, Alimento & Farmacéutico

Typical loads: Paper machine main fans, bombas de vacío, large agitator motors, drying resistive heating loads (AC-1).

Características: Continuous production with zero unscheduled downtime tolerance. Contact wear diagnosis enables advance replacement planning.

🏗️ 6. Infraestructura & Railway Auxiliary Systems

Typical loads: Tunnel exhaust fans, station large water pumps, enfriadores, port crane auxiliary drives, terminal conveying equipment.

Características: Preferred choice for project-type MCC panel builders; compatible with star-delta starter schemes with LA9G mechanical interlock accessory.

🧱 7. OEM Panel Builders & System Integrators

Panel builders: Low voltage Motor Control Centre (MCC), large motor starter cabinets, star-delta starter panels, soft starter bypass contactors (Bypass duty breaking capacity assessment required).

✅ Load Category Compatibility Summary

AC-3 (Primary use): Normal start-stop squirrel cage motors (zapatillas, fans) ✅ Preferred

AC-1: Calentamiento resistivo, resistive load switching, Ith=1050 A ✅

AC-4: Motor plugging / reverse braking, avanzando poco a poco (hoists etc.), derating required and strict operating frequency limits ⚠️

AC-6a: Capacitor bank switching, capacitor dedicated protection required; direct use not recommended

⚠️ Key Selection Limitations

  1. Max AC-3 operating rate: 600 ciclos/hora. Applications with higher frequency (avanzando poco a poco, marcha atrás frecuente) are not recommended; LC1E630U7 is preferred.
  2. Operating ambient: -25 °C ~ +60 °C, wider temperature range than legacy LC1E630U7.
  3. Mounting hole pattern incompatible with LC1E; cabinet base plate re-drilling required for retrofit.
  4. Marine type approval available for vessel applications.

Anterior: