Posicionamiento del producto: SIRIUS Innovation series, Talla S0, 3-contactor de CA de polo. Designed for start/stop control of 3-phase motor and load, with screw terminals and DIN rail mounting.
✅ Model Breakdown
3RT2: New generation SIRIUS contactor series
024: Código de especificación, AC-3 12A / 5.5kW @400V
1: Built-in auxiliary contacts 1NO + 1CAROLINA DEL NORTE
A: bobina de CA
PAG: 230V CA 50 Hz
00: Terminales de tornillo, no additional function modules
📋 Core Technical Parameters
| Artículo | Presupuesto |
| Contactos principales | 3P normally open, AC-3 12A; controls 5.5kW motor at 400V |
| Contactos auxiliares | Integrated 1NO + 1CAROLINA DEL NORTE |
| Voltaje de la bobina | AC230V 50Hz |
| Tamaño del marco | Talla S0; Dimension 45×85×97 mm |
| Alambrado | Terminales de tornillo, Montaje en carril DIN |
| Tensión nominal de aislamiento | 690V; Rated Impulse Withstand Voltage 6kV |
| Temperatura de funcionamiento | -25℃ ~ +60℃ |
| Resistencia mecánica | 10 millones de operaciones |
| Corriente soportada de corta duración | 110A for 10s |
| Clase de protección | IP20 (terminals and front face) |
| Código HS | 85364900 |
🧩 Escenarios de aplicación
Start/stop and reversing control of 3-phase asynchronous motors
aficionados, bombas de agua, belt conveyors and small machine tool loads
HVAC and automation control cabinet power circuits
🔁 Reference Replacement Models
- Upgrade relation: 3RT1024-1AP00 (old, interrumpido) → 3RT2024-1AP00 (successor)
- Same rating with different coil voltage:
3RT2024-1AN20: AC220V 50/60Hz wide-range coil
3RT2024-1BB40: DC24V coil
- Equivalente nacional: siemens 3RT6024-1AP00 (locally manufactured, parámetros eléctricos idénticos)
⚠️ Selección & Notas de mantenimiento
- For replacement, verificar: AC-3 current rating, voltaje de la bobina, quantity of auxiliary contacts
- Recommended matched thermal overload relay: 3RU2124 series (for 5.5kW motors)
- Accesorios opcionales: supresor de sobretensiones, contactos auxiliares laterales, enclavamiento mecánico
- Second-hand inspection checklist: coil resistance measurement, main contact erosion check, pull-in & release action test
Siemens 3RT2024-1AP00 Full Technical Data
SIRIUS 3RT2, marco S0, 3-pole power contactor, terminales de tornillo, Montaje en carril DIN
- Contactos principales (Circuito de potencia)
| Artículo | Presupuesto |
| polacos | 3PAG, 3 contactos principales normalmente abiertos |
| Corriente nominal de funcionamiento, es decir (AC-3) | 12A @ 400V |
| Rated motor power (AC-3) | 5.5kW for 3-phase motor @400V |
| Rated current for resistive load (AC-1) | 20A |
| Tensión nominal de aislamiento Ui | 690V |
| Tensión nominal soportada al impulso Uimp | 6kV |
| AC-4 rated current | 12.5A @ 400V |
| Corriente soportada de corta duración | 110A, 10s |
| Max cross-section of main circuit cable | 10mm簡 |
- Built-in Auxiliary Contacts
Configuración: 1NO + 1CAROLINA DEL NORTE (integrado, no removible)
Auxiliary contact rating: AC-15 3A / DC-13 0.5A
Max voltage for auxiliary contacts: 400V y
III. Parámetros de la bobina (Circuito de control)
| Artículo | Presupuesto |
| Tensión nominal de la bobina | CA 230 V., 50Hz |
| Coil operating voltage range | 0.8 ~ 1.1 × Ue (184V ~ 253V) |
| Apparent power during pull-in | 65Virginia |
| Apparent power during holding | 6Virginia |
| Tipo de bobina | bobina de CA |
- Vida útil & Frecuencia de funcionamiento
Vida mecánica: 10,000,000 operaciones
Vida eléctrica AC-3: aprox. 1,000,000 operaciones
Max operating frequency under AC-3: 1000 ciclos/hora
Max operating frequency under AC-4: 300 ciclos/hora
- Ambiental, Dimensional & Datos mecánicos
Tamaño del marco: Talla S0
Dimensión general: W45mm × H85mm × D97mm
Peso neto: aprox. 0.405kilos
Montaje: 35carril DIN mm, or plate mounting via screws
Terminales: Terminales de abrazadera de tornillo
Temperatura ambiente de funcionamiento: -25℃ ~ +60℃ (inside cabinet)
Temperatura de almacenamiento: -55℃ ~ +80℃
Clase de protección: IP20 (front face and terminals)
- Estándares & Certificaciones
Compliance standard: CEI 60947-4-1 / ES 14048.5
Certificaciones: CCC, CE, UL
Código HS: 85364900
VII. Definición del modelo
3RT2: New generation SIRIUS contactor series
024: Código de especificación, AC-3 12A, Tamaño S0
1: Contactos auxiliares 1NO+1NC incorporados
A: bobina de CA
PAG: AC230V 50Hz
00: Terminales de tornillo, no built-in surge suppression
VIII. Matching Selection Reference
- Relé de sobrecarga térmica: 3RU2124 (matched for 5.5kW motors)
- Accesorios: contactos auxiliares laterales, RC surge absorber, mechanical interlock module
- Locally manufactured equivalent model: 3RT6024-1AP00, fully identical electrical parameters
Siemens 3RT2024-1AP00|Application Fields & Load Types
Specification baseline: marco S0, AC-3 12A / 5.5kilovatios@400V, 3-contactor de CA de polo. Primarily used for direct-on-line (DOL) starting of 3-phase motors; also suitable for AC-1 resistive loads. Integrated 1NO+1NC auxiliary contacts for PLC feedback and interlock circuits.
🏭 1. General Machinery Manufacturing (Más común)
Pequeñas máquinas herramienta: bombas de enfriamiento, bombas de lubricación, chip removal motors
Conveying equipment: cintas transportadoras, líneas de rodillos, ascensores
Pneumatic systems: start/stop for small piston air compressor motors
Equipo de embalaje: stretch wrappers, selladores de cajas, small stirring motors
carpintería & maquinaria de plastico: shredders, auxiliary extruder motors, fans
🌬️ 2. climatización & Automatización de edificios
Air handling unit fans, bombas de agua de refrigeración, condensate pumps for central air conditioning
Small compressors, exhaust fans and fresh air fans of air-cooled / water-cooled units
Building control cabinets, fire smoke exhaust fans (with thermal relay protection)
Cargas resistivas: electric heating elements, commercial lighting circuits (AC-1, max.20A)
🥤 3. Alimento, Bebida & Industria Farmacéutica
Wash pumps, agitator tanks, transfer pumps, small drive motors for filling lines
Fans and pump sets for CIP cleaning systems
Fans and circulating water pumps in cold storage and clean rooms
Ventajas: Wide temperature range -25~+60℃, CCC/CE/UL certifications, suitable for clean control cabinets
💧 4. Tratamiento de agua & Water Supply/Drainage
Small sewage pumps, bombas de agua limpia, chemical dosing agitator motors
Rainwater harvesting, greywater systems, filter drive motors
Local pump station control cabinets, PLC remote start-stop + operation feedback (via built-in auxiliary contacts)
🚗 5. Automotor & Component Automation
Tooling fixtures, roller conveyors at workstations, workstation cooling fans
Exhaust fans in spray booths, small hydraulic station motors
Motor start-stop control for test benches
⚙️ 6. Otras aplicaciones industriales
- MCC Motor Control Centre: 5.5kW motor circuits in drawer units; forms complete motor protection unit together with circuit breaker and thermal relay
- derivación del VFD: Bypass switching for small variable frequency drives (Nota: Frequent switching is not recommended)
- Small hydraulic stations: Start-stop control for hydraulic oil pump motors
- Solar / energy storage auxiliary: Cabinet cooling fans and circulating pump control
✅ Applicable Load Types
- AC-3: 3-phase asynchronous motor (5.5kilovatios@400V), Directo en línea (DOL) a partir de (primary use)
- AC-1: Cargas resistivas, electric heating, incandescent lamp groups, max.20A
- AC-4: Motor inching and forward/reverse rotation (Nota: limited operating frequency, max.300 cycles/hour)
❌ Non-suitable Scenarios
Motors rated >5.5kilovatios
Heavy frequent inching and heavy shock duty (long-term high frequency under AC-4)
Capacitor reactive power compensation (special 3RT26 capacitor contactor required; this model cannot be substituted)
DC main circuit loads (this is an AC contactor)
💡 Selection Key Points
Built-in 1NO+1NC mirror auxiliary contacts for running feedback, fault interlocking and safety circuits, ideal for PLC automation control
Montaje en carril DIN, compact width (45milímetros), suitable for dense cabinet layout
Siemens 3RT2024-1AP00|Cross-Brand Equivalent Comparison Table
Baseline specification: 3PAG, AC-3 12A, 5.5kilovatios@400V, AC230V 50Hz coil, built-in 1NO+1NC auxiliary contacts, terminales de tornillo, Carril DIN
⚠️ Note: Electrically equivalent replacement; dimensiones generales, cutouts and accessories may not be fully compatible. Verify mounting dimensions and auxiliary contact configuration before cabinet retrofit.
| Marca | Modelo equivalente | Observaciones |
| siemens (Misma marca) | 3RT6024-1AP00 | Sirio doméstico, fully identical parameters, local replacement; obsolete predecessor: 3RT1024-1AP00 |
| Electricidad Schneider | LC1D12P7 (TeSys Deca) | 3P AC-3 12A, Bobina de 230V CA, built-in 1NO+1NC; same 45mm width, most popular direct replacement |
| TEJIDO | AF12-30-11-13 (AF series) | 3P 12A, Bobina de 230V CA, built-in 1NO+1NC; AF wide-voltage coil, alta versatilidad |
| Rockwell AB | 100-C12*11, coil code A0 (CA 230 V.) | 100C series, 3P 12A, integrated 1NO+1NC auxiliary contacts |
| OMRON | CJX2-1211 AC230V (Omron contactor) | 3P 12A, 1NO+1NC, terminales de tornillo |
| LOVATO | BF1211A230 | BF series, 3P AC-3 12A, CA 230 V., 1NO+1NC |
| Limpio | NXC-12 11 CA 220/230 V. | Mainstream domestic model, 3P 12A, 1NO+1NC, rentable |
| DELIXI | CJX2s-1211 AC230V | CJX2s series, 12A, 1NO+1NC |
✅ Key Notes for Cross-brand Replacement (Engineering)
- Contactos auxiliares: The reference model has built-in 1NO+1NC. Many economical models only have 1NO (p.ej. LC1N1210), cannot be directly replaced due to missing NC feedback contact. Must select suffix 1211 (1NO+1NC).
- Voltaje de la bobina: Baseline AC230V 50Hz. Distinguish:
M7=AC220V 50/60Hz; P7=AC230V 50Hz (fully matches coil of this model)
- Dimensiones de montaje: Siemens S0 frame width 45mm; Schneider LC1D12, ABB AF12 also 45mm width, directly mountable on DIN rail, cutout generally compatible. Depth differs; verify depth if cabinet space is limited.
- Matched Thermal Relay: Thermal relay model must be changed when switching brand. Contactors and thermal relays from different brands cannot snap-fit together, separate mounting required.
- Enclavamiento mecánico & Accesorios: Cross-brand accessories not interchangeable. Reversing interlock modules and side-mounted auxiliary contacts cannot be mixed.
❗ Quick Selection Recommendation
Direct replacement for project, alta compatibilidad: Schneider LC1D12P7
Cost reduction with domestic product: CHNT NXC-12 11 CA 230 V.
Overseas project, wide voltage requirement: ABB AF12-30-11-13
Siemens 3RT2024-1AP00 (S0 Frame) Dimensiones de montaje
Unidad: milímetros
Dimensiones generales
Ancho W:45
Altura H:85
Profundidad D:97 (from DIN rail backplate to front of terminals)
Métodos de montaje
- Montaje en carril DIN: Carril DIN estándar de 35 mm (TU ÚNICO 60715), clip-on installation
- Fijación por tornillos: Can also be plate-mounted directly on backplate (without rail)
Orientación de montaje: ±180° rotation on vertical plane; ±22.5° tilt forward/backward allowed
Cabinet Clearance for Heat Dissipation
Side-by-side installation: 0mm de espacio libre (can be mounted tightly together)
Minimum top, bottom and front clearance: 10milímetros
Clearance to earthed metal parts: ≥6mm laterally, ≥10mm top/bottom/front
⚠️ Dimension change after adding accessories (Important for cabinet cutout design)
- Front-mounted auxiliary contact block: Ancho & height unchanged, depth increases by 44mm
- Contactos auxiliares laterales: Altura & profundidad sin cambios, width increases
This unit has built-in 1NO+1NC auxiliary contacts; dimension remains 45×85×97 without extra accessories.
Peso
Peso neto: 0.405kilos
Referencia de reemplazo
Schneider LC1D12P7 also has 45mm width, compatible DIN rail position; but depth varies slightly. Double-check depth for cabinet retrofit with limited depth.
contactor,cortacircuitos,sensor,Codificador,SOCIEDAD ANÓNIMA,Convertidor