Schneider MT16H1b MIC2.0 1600A-3P Air Circuit Breaker

Elemento de parámetroSchneider MT16H1b MIC2.0 1600A-3P
Marco actual1600A
Corriente nominal1600A
Número de polo3PAG
Capacidad de rupturaIcu=85kA (H1b class)
Tipo de unidad de disparoMIC2.0 (LI two-stage protection: overload long-time delay + short-circuit instantaneous)
Mounting TypeFixed type / Drawout type

  • Detalles del producto

Schneider Masterpact MT16H1b MIC2.0 1600A-3P is a product of the MT series, designed for the protection and control of distribution lines and equipment in the low-voltage distribution field.

Model Explanation

MONTE: Designates Schneider’s MT series air circuit breakers.

16: Represents a frame current of 1600A.

H1b: Indica la clase de poder de ruptura., suitable for industrial applications with high breaking capacity requirements, with a breaking capacity of 85kA.

MIC2.0: Denotes the trip unit type, an intelligent trip unit with basic overload and short-circuit protection functions.

1600A: The rated current of the circuit breaker.

3PAG: Means three poles.

 

Main Specifications

Tensión nominal: The rated insulation voltage is 1000V, the rated operational voltage is 690V, suitable for AC 50/60Hz circuits.

Capacidad de ruptura: 85el.

Vida mecánica y eléctrica: The mechanical life is generally up to 12,500 operaciones, and the electrical life varies under different voltage conditions, p.ej., 6,000 operations at 440V.

Mounting Types

Two mounting types are generally available: fixed type and drawout type, which can be configured according to actual application scenarios and maintenance requirements.

Campos de aplicación

Suitable for five major markets including industry, energy and infrastructure, commercial and public buildings, residential buildings, and data centers. It can provide fault protection such as overload, cortocircuito, overcurrent, voltage loss and undervoltage for lines.

The dimensional data of Schneider Masterpact MT16H1b MIC2.0 1600A-3P is as follows (official standard, unit: milímetros, format: Height × Width × Depth):

  1. Mounting Type & Dimensional Comparison
Mounting TypeDimensiones (Alto×Ancho×Profundidad)
Fixed Type352×422×297 mm
Drawout Type439×441×395 mm
  1. Notas clave
  2. Model Classification Basis: MT16H1b belongs to the MT08-40N2/H1/H1b/H2/H3/L1 dimensional series, which is different from the MT06-16N1 series. Attention should be paid to the distinction when purchasing switchgear or designing installation space.
  3. Dimensional Definition:

Height (h): Vertical length

Ancho (W.): Horizontal length (for 3P pole configuration)

Depth (D): Front-to-rear length (including the main unit and standard accessories)

  1. Impact of Trip Unit: The MIC2.0 trip unit is a standard configuration, which does not change the basic overall dimensions and only affects the wiring of the control circuit and protection functions.
  2. Expansión de accesorios: If special accessories (such as communication modules, extended protection units) are installed, the depth may increase slightly, and a margin of about 10–20 mm is recommended.

The following are the equivalent models of mainstream brands for Schneider Masterpact MT16H1b MIC2.0 1600A-3P, accurately matched according to key parameters (1600A/3P/85kA/LI protection), with mounting types and trip unit types marked for convenient direct replacement and selection.

Core Parameter Comparison Benchmark

Cross-Brand Model Comparison Table

MarcaEquivalent ModelCapacidad de rupturaTipo de unidad de disparoMounting TypeObservaciones
TEJIDOE2S 1600 PR121/P-LI 3P F/W85el (S class)PR121/P-LI (two-stage protection)Fixed (F) / Drawout (W.)Emax series, replacement for the old E2N model
TEJIDOE3H 1600 PR121/P-LI 3P F/W85el (H class)PR121/P-LI (two-stage protection)Fixed (F) / Drawout (W.)Emax series, higher performance, adecuado para entornos industriales hostiles
siemens3WA1116-4AE03-4JA4 3P85el (M class)ETU600-LI (two-stage protection)Fixed type3WA new generation intelligent air circuit breaker, Bluetooth enabled
siemens3WL1116-2CB32-1AA2 3P85elETU25-LI (two-stage protection)Fixed type3WL classic series, high cost performance
EatonIZMX16H3-A16F 3P85elLI two-stage protectionFixed typeIZMX series, 1600A frame
EatonIZMX16H3-A16W 3P85elLI two-stage protectionDrawout typeIZMX series, drawout base required separately
chintNXA16H08-MF2-AC220 3P85el (H class)MF2 (LI two-stage protection)Fixed typeNXA KunLun series, an optimal choice for domestic replacement
chintNXA16H08-PF2-AC220 3P85el (H class)MF2 (LI two-stage protection)Drawout typeNXA KunLun series, with plug-in connection
DeliciosoCDW3-1600H/3300 1600A85el (H class)Electronic LI trip unitFixed typeCDW3 series, high cost performance
DeliciosoCDW3-1600H/3900 1600A85el (H class)Electronic LI trip unitDrawout typeCDW3 series, with withdrawable mechanism

Key Considerations for Replacement and Selection

  1. Protection Function Matching: Ensure the trip unit of the replacement model is equipped with LI two-stage protection (overload long-time delay + short-circuit instantaneous), consistent with the MIC2.0 function, to avoid insufficient protection or maloperation.
  2. Breaking Capacity Class: The breaking capacity of the target model should be ≥ 85kA, corresponding to S/H class (TEJIDO), M class (siemens), and H class (domestic brands).
  3. Installation Dimension Adaptation: The dimensions of air circuit breakers of the same specification from different brands may vary. Check the installation holes and internal switchgear space before replacement (Schneider fixed type: 352×422×297mm; drawout type: 439×441×395mm).
  4. Auxiliary Function Compatibility: If accessories such as undervoltage release, shunt release and auxiliary contacts are required, select them in matching with the replacement model to ensure the interface is compatible with the control circuit.
  5. Electrical Connection Mode: Confirm that the incoming and outgoing line mode (front connection/ rear connection/ vertical/ horizontal) is consistent with the original design to avoid wiring modification.

Supplementary Notes

All the above models comply with IEC 60947-2 estándar, suitable for AC 50/60Hz distribution systems with 690V and below, and can directly replace Schneider MT16H1b for line protection and control.

If it is necessary to upgrade protection functions (such as LSI three-stage protection, earth fault protection), trip unit models with LSI function from corresponding brands can be selected (p.ej., ABB PR121/P-LSI, Siemens ETU600-LSI, Chint MF3).