Schneider RXZE2M114M is a 14-pin mixed-type relay socket, specially designed for RXM2/RXM4 series miniature intermediate relays. It features 10A rated current, IP20 protection degree and wide operating temperature range, suitable for various industrial control applications. Its mixed terminal layout ensures flexible wiring, and dual mounting modes fit different control cabinet designs. Approved with CE, UL, CSA y otras certificaciones internacionales, it can be shipped as ordinary goods by air without special formalities.
- Definición del código del modelo
| Segmento de código | Significado | Descripción |
| RXZ | Serie de productos | Zelio Relay series relay sockets |
| E2 | Código de serie | 2nd-generation standard socket, compatible with 2-pole & 4-pole RXM relays |
| METRO | Terminal Arrangement | Mixed layout, coil and contact terminals arranged alternately |
| 114 | Configuración de contacto | 14 patas, fits relays with 4 change-over contacts (4CO/4PDT) o 2 change-over contacts (2CO/2PDT) |
| METRO | Regional Standard | Compliant with RIS standard; differs from RXZE2M114 (SCR standard) in partial certification details |
Nombre completo del producto: Schneider Harmony Zelio RXZE2M114M Mixed-type 14-pin Relay Socket, compatible with RXM2/RXM4 relays, screw terminal connection, Montaje en carril DIN
- Especificaciones técnicas básicas
| Categoría | Presupuesto | Observaciones |
| Parámetros básicos | ||
| Tipo de producto | Mixed-type relay socket | Mixed layout of coil and contact terminals |
| Relés compatibles | RXM2 (2CO, 8-alfiler), RXM4 (4CO, 14-alfiler), REXL series | Compatible with standard Schneider Zelio relays |
| Pin Shape | Flat type | Ensures stable plug-in connection |
| Wiring Type | M3 screw terminals | Tightening torque ≤1 N·m |
| Parámetros eléctricos | ||
| Tensión de funcionamiento nominal (ue) | ≤250V AC/DC | Applicable to most industrial control circuits |
| Conventional Free-air Thermal Current (Ith) | 10A | Continuous rated working current |
| Rigidez dieléctrica | 2500V | Cumple con IEC 61984 |
| Grado de protección | IP20 | Finger-proof and dust-proof |
| Parámetros mecánicos | ||
| Método de montaje | 35mm standard DIN rail clip-on / panel screw mounting | Dual installation options |
| Ancho | 27milímetros | Tamaño compacto, ahorro de espacio |
| Peso neto | 0.056kilos | Lightweight design |
| Applicable Wires | Solid wire: 0.5~2.5mm² (AWG20~14) | Covers various wiring requirements |
| Stranded wire with ferrule: 0.25~2.5mm² (AWG22~14) | ||
| Twin solid wire: 0.5~1.5mm² (AWG20~16) | ||
| Twin stranded wire with ferrule: 0.25~1mm² (AWG22~17) | ||
| Parámetros ambientales | ||
| Temperatura de funcionamiento | -40°C ~ +55°C | Wide temperature range for harsh industrial environments |
| Temperatura de almacenamiento | -40°C ~ +85°C | Suitable for transportation and storage |
| Certificaciones | CE, UL, CSA, Lloyd’s | Meets major international safety standards |
| Ordering Info | ||
| Part Number | RXZE2M114M | Unique product model |
| Minimum Order Qty | 10 piezas | Standard packing quantity |
| Modelo alternativo | RXZE2M114 (SCR standard) | Same function, different certification standards |
- Fallos comunes & Soluciones de mantenimiento
3.1 Solución de problemas
| Fenómeno de falla | Posibles causas | Soluciones |
| Relay cannot be inserted/removed | 1. Deformed socket pins | 1. Straighten pins gently with tweezers |
| 2. Oxidized/dirty relay pins | 2. Clean pins with anhydrous alcohol | |
| 3. Distorted socket caused by over-tight installation | 3. Adjust installation tightness and reinstall | |
| mal contacto / signal interruption | 1. Terminales de cableado flojos | 1. Retighten terminals within 1 N*m torque |
| 2. Oxidized/burned contacts | 2. Polish contacts gently with metallographic sandpaper | |
| 3. Deformed internal terminals | 3. Inspect and replace defective socket | |
| Abnormal overheating | 1. Overload operation over 10A | 1. Replace higher-capacity socket or split load |
| 2. Large contact resistance at terminals | 2. Re-crimp wires for better contact | |
| 3. Temperatura ambiente excesivamente alta | 3. Improve ventilation and lower temperature | |
| Reduced insulation performance | 1. Dust and oil accumulation | 1. Clean socket surface regularly |
| 2. Insulation aging under long-term high temperature | 2. Replace aged sockets timely | |
| 3. Chemical corrosion | 3. Use anti-corrosion sockets or protective covers |
3.2 Daily Maintenance Recommendations
- Inspección periódica: Check terminal tightness every 3 meses
- Limpieza: Remove dust with compressed air every 6 meses, wipe surface with anhydrous alcohol if needed
- Preventive Replacement: Replace sockets every 2-3 years in high-temperature, high-humidity or corrosive environments
- Installation Rules: Avoid mechanical shock and vibration; ensure full fitting between socket and relay; keep ≥5mm gap between adjacent sockets for heat dissipation
- Consejo de selección: Reservar 20% current margin according to resistive/inductive loads to avoid overload
- Full RXZE2 Series Model List
| Modelo | Diseño de terminales | Pin Count | Relé compatible | Características | Solicitud |
| RXZE2M114M | Mixed | 14 | RXM2(2CO), RXM4(4CO) | RIS standard, terminales de tornillo | control industrial general, flexible wiring |
| RXZE2M114 | Mixed | 14 | RXM2(2CO), RXM4(4CO) | SCR standard, terminales de tornillo | Same function, different certifications |
| RXZE2S114M | Separated | 14 | RXM4(4CO) | Separated coil & contact terminals | Logic control circuit, anti-interference |
| RXZE2S111M | Separated | 11 | RXM3(3CO) | For 3-pole relays | Special control such as star-delta starting |
| RXZE2S108M | Separated | 8 | RXM2(2CO) | For 2-pole relays | Compact control circuits |
| RXZE2M108M | Mixed | 8 | RXM2(2CO) | Mixed 8-pin design | Compact control boxes |
- Cross-brand Comparison
| Marca | Modelo | Montaje | Precio(Dólar estadounidense) | Compatibilidad |
| Schneider | RXZE2M114M | DIN Rail/Panel | 6.23 | RXM2/RXM4 series |
| Omrón | PYFZ-014 | Carril DIN | 5.8 | Partial fit for RXM, fits MY4 |
| siemens | 3RH2911-1FA22 | Carril DIN | 7.5 | Limited compatibility with 3RT series |
| TEJIDO | CR-M14S | Carril DIN | 6.9 | Partial fit for CR-M series |
| IDEC | SH4B-05B | Carril DIN | 6.1 | Good mechanical compatibility with RH4B |
| Fénix | PLC-RSC-24DC/21-21 | Carril DIN | 8.2 | Low cross-brand compatibility |
Replacement Suggestion
- Full compatibility: Adopt original Schneider RXZE2M114 / RXZE2M114M
- Cost-effective alternative: Omron PYFZ-014, IDEC SH4B-05B
- Nota: Verify terminal wiring diagrams before replacement to avoid wiring errors
- Air Shipment Compliance & Certificaciones
6.1 Shipment Regulation
Conclusión: Pure electromechanical component, no built-in lithium battery or super capacitor, non-dangerous goods
Shipping Class: Ordinary cargo, no UN38.3 test or dangerous goods packaging required
Packaging Advice: Pack individually with anti-static bag; use hard carton for anti-deformation; separate bulk goods with partition boards
6.2 Principales Certificaciones
| Certificate | Estándar | Estado | Applicable Area |
| CE | EN/IEC 61984 | Compliant | EU & EEA |
| UL | UL 508 | Compliant | América del norte |
| CSA | CSA C22.2 No.14 | Compliant | Canadá |
| Lloyd’s | Marine Standard | Compliant | Marina & offshore engineering |
| RoHS | 2011/65/EU | Compliant | Global environmental compliance |
6.3 Certification Inquiry Way
- Search RXZE2M114M on official Schneider website
- Check certification marks on product labels and packages
- Obtain full certification documents via Schneider technical support
- Solicitud & Guía de selección
7.1 Escenarios aplicables
Automatización industrial: PLC output expansion, válvula solenoide & contactor control
control de motores: Star-delta starting, forward/reverse rotation, protección contra sobrecarga
Electricidad del edificio: Iluminación, air conditioning and fire linkage control
Marine engineering: Marine electrical control with Lloyd’s approval
control de procesos: Sensor signal amplification, actuator drive control
7.2 Unrecommended Scenarios
Severe high-vibration working conditions without shockproof measures
Strong corrosive environment such as chemical plants and salt fog areas
Working current exceeding 10A rated value
High-frequency switching over 10 veces por segundo
7.3 Pasos de selección
- Confirm relay model: RXM2 (2CO 8-pin) / RXM4 (4CO 14-pin)
- Choose socket type: Mixed (METRO) / Separated (S)
- Confirm pin quantity: 8-pin /14-pin
- Select standard: RIS (M suffix) / SCR standard
- Confirm mounting method: DIN rail or panel mounting
contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares


















NH42-63-318x560.png)