Schneider RXZE2M114M 14-pin Relay Socket - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

 Schneider RXZE2M114M 14-pin Relay Socket - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

eléctrico/

Schneider RXZE2M114M 14-pin Relay Socket

Schneider RXZE2M114M is a 14-pin mixed-type relay socket, specially designed for RXM2/RXM4 series miniature intermediate relays. It features 10A rated current, IP20 protection degree and wide operating temperature range, suitable for various industrial control applications. Its mixed terminal layout ensures flexible wiring, and dual mounting modes fit different control cabinet designs. Approved with CE, UL, ...

  • Detalles del producto

Schneider RXZE2M114M is a 14-pin mixed-type relay socket, specially designed for RXM2/RXM4 series miniature intermediate relays. It features 10A rated current, IP20 protection degree and wide operating temperature range, suitable for various industrial control applications. Its mixed terminal layout ensures flexible wiring, and dual mounting modes fit different control cabinet designs. Approved with CE, UL, CSA y otras certificaciones internacionales, it can be shipped as ordinary goods by air without special formalities.

  1. Definición del código del modelo
Segmento de códigoSignificadoDescripción
RXZSerie de productosZelio Relay series relay sockets
E2Código de serie2nd-generation standard socket, compatible with 2-pole & 4-pole RXM relays
METROTerminal ArrangementMixed layout, coil and contact terminals arranged alternately
114Configuración de contacto14 patas, fits relays with 4 change-over contacts (4CO/4PDT) o 2 change-over contacts (2CO/2PDT)
METRORegional StandardCompliant with RIS standard; differs from RXZE2M114 (SCR standard) in partial certification details

Nombre completo del producto: Schneider Harmony Zelio RXZE2M114M Mixed-type 14-pin Relay Socket, compatible with RXM2/RXM4 relays, screw terminal connection, Montaje en carril DIN

  1. Especificaciones técnicas básicas
CategoríaPresupuestoObservaciones
Parámetros básicos
Tipo de productoMixed-type relay socketMixed layout of coil and contact terminals
Relés compatiblesRXM2 (2CO, 8-alfiler), RXM4 (4CO, 14-alfiler), REXL seriesCompatible with standard Schneider Zelio relays
Pin ShapeFlat typeEnsures stable plug-in connection
Wiring TypeM3 screw terminalsTightening torque ≤1 N·m
Parámetros eléctricos
Tensión de funcionamiento nominal (ue)≤250V AC/DCApplicable to most industrial control circuits
Conventional Free-air Thermal Current (Ith)10AContinuous rated working current
Rigidez dieléctrica2500VCumple con IEC 61984
Grado de protecciónIP20Finger-proof and dust-proof
Parámetros mecánicos
Método de montaje35mm standard DIN rail clip-on / panel screw mountingDual installation options
Ancho27milímetrosTamaño compacto, ahorro de espacio
Peso neto0.056kilosLightweight design
Applicable WiresSolid wire: 0.5~2.5mm² (AWG20~14)Covers various wiring requirements
Stranded wire with ferrule: 0.25~2.5mm² (AWG22~14)
Twin solid wire: 0.5~1.5mm² (AWG20~16)
Twin stranded wire with ferrule: 0.25~1mm² (AWG22~17)
Parámetros ambientales
Temperatura de funcionamiento-40°C ~ +55°CWide temperature range for harsh industrial environments
Temperatura de almacenamiento-40°C ~ +85°CSuitable for transportation and storage
CertificacionesCE, UL, CSA, Lloyd’sMeets major international safety standards
Ordering Info
Part NumberRXZE2M114MUnique product model
Minimum Order Qty10 piezasStandard packing quantity
Modelo alternativoRXZE2M114 (SCR standard)Same function, different certification standards
  1. Fallos comunes & Soluciones de mantenimiento

3.1 Solución de problemas

Fenómeno de fallaPosibles causasSoluciones
Relay cannot be inserted/removed1. Deformed socket pins1. Straighten pins gently with tweezers
2. Oxidized/dirty relay pins2. Clean pins with anhydrous alcohol
3. Distorted socket caused by over-tight installation3. Adjust installation tightness and reinstall
mal contacto / signal interruption1. Terminales de cableado flojos1. Retighten terminals within 1 N*m torque
2. Oxidized/burned contacts2. Polish contacts gently with metallographic sandpaper
3. Deformed internal terminals3. Inspect and replace defective socket
Abnormal overheating1. Overload operation over 10A1. Replace higher-capacity socket or split load
2. Large contact resistance at terminals2. Re-crimp wires for better contact
3. Temperatura ambiente excesivamente alta3. Improve ventilation and lower temperature
Reduced insulation performance1. Dust and oil accumulation1. Clean socket surface regularly
2. Insulation aging under long-term high temperature2. Replace aged sockets timely
3. Chemical corrosion3. Use anti-corrosion sockets or protective covers

3.2 Daily Maintenance Recommendations

  1. Inspección periódica: Check terminal tightness every 3 meses
  2. Limpieza: Remove dust with compressed air every 6 meses, wipe surface with anhydrous alcohol if needed
  3. Preventive Replacement: Replace sockets every 2-3 years in high-temperature, high-humidity or corrosive environments
  4. Installation Rules: Avoid mechanical shock and vibration; ensure full fitting between socket and relay; keep ≥5mm gap between adjacent sockets for heat dissipation
  5. Consejo de selección: Reservar 20% current margin according to resistive/inductive loads to avoid overload
  6. Full RXZE2 Series Model List
ModeloDiseño de terminalesPin CountRelé compatibleCaracterísticasSolicitud
RXZE2M114MMixed14RXM2(2CO), RXM4(4CO)RIS standard, terminales de tornillocontrol industrial general, flexible wiring
RXZE2M114Mixed14RXM2(2CO), RXM4(4CO)SCR standard, terminales de tornilloSame function, different certifications
RXZE2S114MSeparated14RXM4(4CO)Separated coil & contact terminalsLogic control circuit, anti-interference
RXZE2S111MSeparated11RXM3(3CO)For 3-pole relaysSpecial control such as star-delta starting
RXZE2S108MSeparated8RXM2(2CO)For 2-pole relaysCompact control circuits
RXZE2M108MMixed8RXM2(2CO)Mixed 8-pin designCompact control boxes
  1. Cross-brand Comparison
MarcaModeloMontajePrecio(Dólar estadounidense)Compatibilidad
SchneiderRXZE2M114MDIN Rail/Panel6.23RXM2/RXM4 series
OmrónPYFZ-014Carril DIN5.8Partial fit for RXM, fits MY4
siemens3RH2911-1FA22Carril DIN7.5Limited compatibility with 3RT series
TEJIDOCR-M14SCarril DIN6.9Partial fit for CR-M series
IDECSH4B-05BCarril DIN6.1Good mechanical compatibility with RH4B
FénixPLC-RSC-24DC/21-21Carril DIN8.2Low cross-brand compatibility

Replacement Suggestion

  1. Full compatibility: Adopt original Schneider RXZE2M114 / RXZE2M114M
  2. Cost-effective alternative: Omron PYFZ-014, IDEC SH4B-05B
  3. Nota: Verify terminal wiring diagrams before replacement to avoid wiring errors
  4. Air Shipment Compliance & Certificaciones

6.1 Shipment Regulation

Conclusión: Pure electromechanical component, no built-in lithium battery or super capacitor, non-dangerous goods

Shipping Class: Ordinary cargo, no UN38.3 test or dangerous goods packaging required

Packaging Advice: Pack individually with anti-static bag; use hard carton for anti-deformation; separate bulk goods with partition boards

6.2 Principales Certificaciones

CertificateEstándarEstadoApplicable Area
CEEN/IEC 61984CompliantEU & EEA
ULUL 508CompliantAmérica del norte
CSACSA C22.2 No.14CompliantCanadá
Lloyd’sMarine StandardCompliantMarina & offshore engineering
RoHS2011/65/EUCompliantGlobal environmental compliance

6.3 Certification Inquiry Way

  1. Search RXZE2M114M on official Schneider website
  2. Check certification marks on product labels and packages
  3. Obtain full certification documents via Schneider technical support
  4. Solicitud & Guía de selección

7.1 Escenarios aplicables

Automatización industrial: PLC output expansion, válvula solenoide & contactor control

control de motores: Star-delta starting, forward/reverse rotation, protección contra sobrecarga

Electricidad del edificio: Iluminación, air conditioning and fire linkage control

Marine engineering: Marine electrical control with Lloyd’s approval

control de procesos: Sensor signal amplification, actuator drive control

7.2 Unrecommended Scenarios

Severe high-vibration working conditions without shockproof measures

Strong corrosive environment such as chemical plants and salt fog areas

Working current exceeding 10A rated value

High-frequency switching over 10 veces por segundo

7.3 Pasos de selección

  1. Confirm relay model: RXM2 (2CO 8-pin) / RXM4 (4CO 14-pin)
  2. Choose socket type: Mixed (METRO) / Separated (S)
  3. Confirm pin quantity: 8-pin /14-pin
  4. Select standard: RIS (M suffix) / SCR standard
  5. Confirm mounting method: DIN rail or panel mounting

Anterior:

Deja una respuesta

Dejar un mensaje