Marca: Sáko (Taiwán) | 5/2 Forma, Single Solenoid, Internal Pilot Pneumatic Válvula Solenoide
✅ Definición del código del modelo
PU520: 5/2 five-port two-position válvula
02: Main port G1/4″; Exhaust port G1/8″
S: Solenoide simple (retorno de primavera, monostable)
CC 24 V: Voltaje de la bobina DC24V (Order code No.9)
Standard thread: G thread; Opcional: TNP / RC
Suffix L = with LED indicator
📌 Especificaciones técnicas básicas
| Artículo | Parámetro |
| Medio | Clean dry compressed air |
| Effective sectional area | 18 mm² |
| Presión de funcionamiento | 0.15~0.8 MPa (1.5~8 kgf/cm²) |
| Presión de prueba | 0.99 MPa |
| Actuación | Piloto interno |
| Cuerpo | Aleación de aluminio anodizado |
| Temperatura ambiente | -10℃ ~ +60℃ |
| ciclo de trabajo | 100% DE (continuous energization available) |
| Clase de protección | IP65 (DIN socket assembly) |
| Clase de aislamiento | Clase F |
| Tolerancia de voltaje | ±10% |
| Peso neto | 270 gramo |
| Standard accessory | Lockable manual override button for commissioning |
📎 Matching Parts & Alternativas
- Manifold base: MF520-02 (multi-station manifold available)
- Energy-saving upgrade: E-PU520-02S-DC24V, lower power consumption and less heat rise for long-term energization
- Cross-brand equivalent models:
Ártico: 4V210-08 DC24V
hombre mental: MVSC-220-4E1 DC24V
⚠️ Notas importantes
Single solenoid design: auto return when power off. Select PU520-02D (doble solenoide) for latching function without power supply.
Internal pilot requires minimum inlet pressure ≥ 0.15 MPa. Select external pilot type PU520A for low-pressure or vacuum applications.
Standard DIN43650 socket; LED version with suffix L is optional.
Complete Technical Datasheet — SHAKO PU520-02S-CC 24 V
nombre completo: PU520-02-S DC24V 5/2-Way Internal Pilot Single Solenoid Valve (PU Series Pilot Valve)
Original PDF source: SHAKO official PU520 series catalogue
- Codificación de modelos
PU520 02 S DC24V
PU520: 5/2 five-port two-position pilot solenoid valve
02: Main air port G1/4″; Exhaust port G1/8″
S: Solenoide simple, retorno de primavera (auto reset on power loss)
CC 24 V: Voltaje de la bobina DC24V
Thread default: GRAMO; Optional Rc (PT), TNP; Suffix L = with LED indicator
- Características del producto
- Medium-size body with large flow capacity, effective area 18 mm²
- Equipped with lockable manual override, no electricity or air supply needed for field test
- Anodized aluminum body, wear-resistant and long service life
- DIN43650 standard socket, IP65 protection suitable for industrial sites
- Can be mounted on manifold or with individual base
- Optional energy-saving coil E-PU520-02S-DC24V, low power and low temperature rise
- Rated Technical Data
| Parámetro | Valor |
| Función | 5/2 five-port two-position, piloto interno |
| Control | Solenoide simple, retorno de primavera |
| Líquido | Clean dry compressed air |
| Main port | G1/4″ |
| Puerto de escape | G1/8″ |
| Effective area | 18 mm² |
| Presión de funcionamiento | 0.15~0.8 MPa (1.5~8 kgf/cm²) |
| Minimum actuating pressure | ≥0.15 MPa (limit for internal pilot) |
| Presión de prueba | 0.99 MPa |
| Temperatura ambiente | -10℃ ~ +60℃ |
| ciclo de trabajo | 100% DE (continuous power-on) |
| Grado de protección | IP65 (with DIN socket fully sealed) |
| Clase de aislamiento | F |
| Tolerancia de voltaje | ±10% |
| Peso neto | 270 gramo |
| Material del cuerpo | Aleación de aluminio anodizado |
| Material del sello | caucho de nitrilo NBR (estándar) |
| Standard manifold base | MF520-02 (multi-station: MF520-02-02 / 03 …) |
⚠️ Do not use this internal pilot model under low pressure or vacuum; choose PU520A-02S (piloto externo) en cambio
- Definición de puerto (5/2 Forma)
PAG: Entrada (G1/4)
A: Producción 1 (G1/4)
B: Producción 2 (G1/4)
R, S: Two exhaust ports (G1/8)
Estado desenergizado: P ↔ A open; B ↔ S exhaust
Estado energizado: P ↔ B open; A ↔ R exhaust
Auto reset to P-A open when power cuts off (single solenoid characteristic)
- Bobina & Alambrado (DC24V DIN43650)
Definición de pin: 1(+), 2(-), PE tierra
Non-polarized coil version: terminales 1 & 2 can be swapped; LED version is polarized – wrong polarity only causes indicator off without damaging the valve
Consumo de energía: Standard coil ≈4.8W; E energy-saving coil ≈1.2W
Cable outer diameter: Φ6~Φ8mm; use waterproof cable gland
Grounding is mandatory; install full sealing gaskets for dusty & splash environments
- En general & Dimensiones de montaje (PU520-02-S)
Ancho del cuerpo: 26 milímetros
Orificios de montaje: 2×Φ4.3; hole spacing: 70 milímetros
Altura total (con bobina & enchufe): aprox. 100 milímetros
Longitud total: aprox. 130 milímetros
Two mounting options:
- Manifold mounting: fixed on MF520-02 (recommended for multi-valve centralized control)
- Individual pipe mounting: with separate base
Manifold MF520-02 supports 2~10 stations, with blanking plugs and mufflers optional
- Instalación, Puesta en servicio & Operation Rules
Instalación
- Install air filter (≥40μm) río arriba; air treatment triple unit is recommended; no oil & dirt contamination allowed
- No strict mounting orientation; keep coil facing upward to avoid water accumulation
- Purge all piping before connecting the valve to prevent metal chips jamming the spool
- Install mufflers on exhaust ports for noise reduction and dust prevention; never block exhaust ports
Manual Override Button
Press down: force spool to shift; rotate 90° to lock the shifted position for continuous testing
Reiniciar: turn back to unlock; spring resets automatically after release
Manual lock is only for commissioning; do not keep locked during normal operation
Power-on Commissioning Sequence
- Supply compressed air up to rated pressure and check for air leakage
- Apply DC24V power and verify cylinder movement; check LED lamp (L model)
- Cut power to confirm automatic spring reset
- Troubleshooting List
| Falla | Artículos de inspección |
| No shifting when energized | 1. Voltage below 21.6V; 2. Pilot orifice blocked; 3. Inlet pressure lower than 1.5 bar; 4. Coil burned out |
| Fail to reset after power off | Stuck return spring; spool jammed by foreign matter; blocked exhaust port |
| Continuous air leakage at body or exhaust port | Worn seals; spool scratched by dirt; pressure exceeding upper limit |
| Slow action | Poor exhaust, clogged muffler, insufficient air pressure |
| Bobina sobrecalentada | Voltage higher than 26.4V; continuous overload; non-100%ED coil selected |
- Lista de repuestos
- Manifold base: MF520-02 (1-estación), MF520-02-XX (multi-station)
- DIN socket: Standard socket / LED indicator socket
- Muffler: BSL-M5 / BSL-01 (fits G1/8 exhaust port)
- Blanking plugs, juntas, separate coil assembly
- Isolation block SOB52-02: Replace valve without shutting down main air supply (online maintenance without line stop)
- Modelos equivalentes entre marcas
Ártico: 4V210-08 DC24V
hombre mental: MVSC-220-4E1 DC24V
chelic: SV-5201 DC24V
Nota: Mounting hole pitch and base are not interchangeable; only function & port size match
- Programa de mantenimiento
Normal environment: Blow exhaust ports and check air leakage every 3 meses
Dust/humid environment: Monthly inspection; disassemble & clean spool and inspect NBR seals every 6 meses
Seal service life: Aprox.. 5 million switching cycles; replace seal kit before reaching cycle limit
Working Principle — SHAKO PU520-02S-DC24V
5/2 five-port two-position, solenoide único, internal pilot solenoid valve
Principio fundamental: The coil only actuates a small pilot valve; air pressure difference from main supply pushes the main spool to shift; spring resets automatically when power cuts off (not direct pull by coil like direct-acting valves)
Estructura interna
- Solenoid assembly (Bobina de 24V CC + armadura): controls the small pilot valve
- Pilot air circuit: piloto interno, air is tapped from P inlet; no external control air required
- carrete principal & resorte de retorno
- Five ports: PAG (entrada), A/B (outlets), R/S (exhausts)
Key limitation: Internal pilot needs minimum inlet pressure ≥0.15 MPa (1.5 bar) to build pressure difference for spool actuation; select PU520A external pilot for low-pressure & vacuum applications
- Estado desenergizado (Normal Position, Spring Return)
Bobina desenergizada, armature drops, pilot valve closes; pilot control chamber vents
Right-side return spring pushes main spool to left
Air circuit: P ↔ A open; B ↔ S exhaust
Cylinder A side air inlet, B side exhaust; cylinder stays at initial position
- Estado energizado (DC24V Powered On)
Bobina energizada, magnetic force pulls armature up; pilot valve opens
Compressed air from P inlet flows through pilot hole into right-side control chamber
Pressure on right side overcomes spring force; air pressure pushes main spool to shift
Air circuit switches: P ↔ B open; A ↔ R exhaust
Cylinder B side air inlet, A side exhaust; cylinder reverses movement
- Power Cut Off Again
Magnetic force disappears, pilot valve closes; air inside pilot chamber vents out from pilot exhaust hole
Main spool is pushed back to original position by return spring; air circuit reverts to P-A open status
✅ Feature of single solenoid (S): auto reset on power loss (monostable); select double solenoid (D) for position latching without power supply.
Manual Override Principle
The lockable manual push button mechanically actuates the pilot spool without power or air supply, simulating energized status for field commissioning. Rotate 90° to lock the shifted position; remember to unlock after testing.
Advantages over Direct-Acting Valves
Baja potencia de la bobina (≈4.8W), tamaño pequeño, aumento de temperatura baja
Large spool flow capacity (18 mm² effective area)
Soportes 100% energización continua (100% DE)
Desventaja: Minimum actuating pressure threshold; cannot work under zero pressure
Air Circuit Logic Summary
| Estado | Open Path | Exhaust Path |
| Desenergizado (Normal) | P→A | B→S |
| energizado | P→B | A→R |
SHAKO Solenoid Valve Full Series Catalogue (By Function & Tamaño)
Nota: PU, SOY, BM, peso corporal, PD, CY = pneumatic directional control valves (5/2,5/3,3/2); PU220/SPU220/PU225 = 2/2 fluid valves (aire, agua, aceite); Prefix E = energy-saving low-power coil
Suffix General Definition
S: Solenoide simple (retorno de primavera, monostable)
D: Doble solenoide (enganche, no power hold)
A: Piloto externo (vacío & low-pressure use)
B: Built-in silencer
X/Y: 5/3-way mid-position function (X=closed center; Y=exhaust center; Z=pressurized center)
l: Con indicador LED
mi: Bobina de ahorro de energía
Port code: 01=G1/8; 02=G1/4; 03=G3/8; 04=G1/2
- 5/2 2-Position 5-Port / 5/3 3-Position 5-Port Pilot Solenoid Valves (Main cylinder control)
AM520 Series (18mm narrow body, Puerto G1/8, equivalent to Airtac 4V110)
AM520-01S / AM520-01D (5/2 single/double solenoid)
AM530X/Y-01D (5/3 closed/exhaust/pressurized center)
AM520A: Piloto externo; AM520B: Built-in silencer
Matching manifold: MF520-01
BM520 Series (22mm de ancho, Puerto G1/4, equivalent to Airtac 4V210)
BM520-02S / BM520-02D
BM530X/Y-02D (5/3 three-position)
BM520A: Piloto externo; E-BM520: Versión de ahorro de energía
Matching manifold: MFB520-02
PU520 Series (Your selected medium size, 26mm de ancho, gran flujo, G1/4~G1/2)
PU520-02S/D, PU520-03S/D, PU520-04S/D (5/2 two-position)
PU530X/Y-02D, PU530X/Y-03D, PU530X/Y-04D (5/3 three-position)
PU520A: Piloto externo (vacuum/low pressure); PU520AB
E-PU520: Bobina de ahorro de energía (baja potencia & low heat)
Matching manifold: MF520-02 / MF520-03 / MF520-04
BW520 Series (Wide body high flow, G3/8 & G1/2, equivalent to 4V410)
BW520-03S/D, BW520-04S/D
BW530X/Y-03D, BW530X/Y-04D
PS520 Series (ISO standard mounting, ISO1/ISO2 interchangeable base)
PS520-02S/D, PS520-03S/D, PS520-04S/D
PS520F: ISO flange mounting
E-PS520: Energy-saving model
CY520 / CY525 Series (Economical pilot valves)
CY520-02S/D, CY520-03S/D
E-CY520, E-SCY520 (SUS316 stainless steel anti-corrosion version)
CY525: Combined 3/2 + 5/2 función
- 3/2 3-Port 2-Position Pilot Solenoid Valves (Single-acting cylinder, vacío & control de soplado)
PU320 / PU322N: 3/2 pilot type, puerto 01/02/03/04
BM320: 3/2 válvula piloto
E-AM325: Energy-saving direct-acting 3/2 válvula
III. 2/2 2-Port 2-Position Solenoid Valves (Fluid control: aire, agua, aceite, vapor, corrosive low-pressure media)
acción directa / pilot-operated; brass body / SUS316 stainless steel; normalmente cerrado (CAROLINA DEL NORTE) como estándar
- PU220A Direct-acting (baja presión & vacuum applicable)
PU220A-01/02/03/04/06/08
- SPU220AR SUS316 stainless steel direct type, anti-corrosion for air & agua
SPU220AR-01/02/03; E-SPU220AR energy-saving version
- PU225X Pilot-operated 2/2 (high pressure large flow, máximo. 50 bar)
PU225X-03/04/06/08
- PU225S Steam-specific 2/2 válvula; flange type PU225SF
- DC220 Large-bore 2/2 válvula (3/4″~3″, dust removal & suministro de agua)
- Modelos Especiales
E-SPU520: SUS316 stainless steel 5-port pilot valve for corrosive environment
Explosion-proof coil optional: Compatible with PU/BM/PS series, ATEX T4 certified
Pneumatic pilot valves (sin solenoide): PA520, PB520, PP520, same body size as solenoid versions
- Selection Cross Reference Table
| Serie | Ancho del cuerpo | Standard Port | Equivalent Airtac Model |
| AM520 | 18milímetros | G1/8 | 4V110-06 |
| BM520 | 22milímetros | G1/4 | 4V210-08 |
| PU520 | 26milímetros | G1/4~1/2 | 4V310-10 / 4V410-15 |
| BW520 | Alto flujo | G3/8, 1/2 | 4V410-15 |
| PS520 | ISO standard | G1/4~1/2 | ISO standard valve |
- Manifold Naming Rule
MF520-02-03: PU520 series, G1/4 thread, 3-colector de estación; MFB520 = dedicated manifold for BM520 series
contactor,cortacircuitos,sensor,Codificador,SOCIEDAD ANÓNIMA,Convertidor




















NH42-63-318x560.png)