Tipo de producto: SIRIUS 3RV2 series frame S2 disyuntor de protección del motor (protector de motor), active production model, made in Germany
- Explicación del código del modelo
3RV 2 0 31 4 K A 10
3RV: SIRIUS motor protection circuit breaker
2: 2nd generation of 3RV2 series
0: Versión estándar, no pre-fitted auxiliary contacts
31: Frame size S2
4: Trip current rating code
k: Thermal setting range 62~73A
A: Terminales de tornillo
10: Capacidad de ruptura estándar (without additional contacts)
- Datos técnicos básicos
| Artículo | Presupuesto |
| Tamaño del marco | T2, width 55mm, Montaje en carril DIN |
| polacos | 3PAG |
| Thermal overload setting range | 62 ~ 73A (adjustable via front knob) |
| Instantaneous electromagnetic short-circuit trip | 949A (fijado) |
| clase de viaje | Clase 10 (for normal motor starting; trips within 10s at 7.2× rated current) |
| Tensión operativa nominal | CA 690V, CC 250 V. |
| Rated ultimate short-circuit breaking capacity Icu@400V | 65el |
| Tipo de conexión | Terminales de tornillo |
| Contactos auxiliares incorporados | Ninguno; auxiliary contact modules must be fitted separately |
| Potencia del motor aplicable (CA 400 V.) | Aprox.. 37kW 3-phase motor |
| Peso neto | 1.172kilos |
| Código Aduanero SA | 85362090 |
- Funciones de protección
- Protección contra sobrecarga: Inverse-time thermal trip via bimetallic strip, motor overload protection and phase loss protection
- Protección contra cortocircuitos: Instantaneous electromagnetic trip for rapid short-circuit disconnection
- Front-mounted TEST pushbutton for manual tripping test of the mechanism
- Handle position indication: EN / APAGADO / fault trip position; padlockable for lockout
- Alambrado & Especificaciones de instalación
Main circuit conductor: máx.. 1×35mm² solid/stranded cable; máximo. 1×25mm² fine-stranded cable with ferrule
Tightening torque for main terminals: 3.0~4.5 N·m, tornillos m6
Accepts top-in or bottom-in wiring; DIN35mm rail mounting
Can be assembled with SIRIUS 3RT contactor to form a direct-on-line starter, constituting a motor protection starter unit
- Selección & Información de reemplazo
Same-series Replacement (Misma calificación)
3RV2031-4KA15: Version with pre-fitted auxiliary contacts (1NO+1NC)
Nota: 3RV2031-4KA10 has no built-in auxiliary contacts. For feedback signals, 3RV2901 auxiliary contact accessory must be mounted externally.
Domestic Alternative Reference
siemens local China 3RV5/3RV6 series equivalent: 3RV5031-4KA10 (domestic frame S2, 62~73A, terminales de tornillo, largely identical parameters)
- Aplicaciones típicas
3-motores asíncronos de fase, fans, bombas de agua, compresores, conveyor motor circuit protection
Motor starter circuits inside control cabinets, combined with contactors as starter assemblies
Motor protection for machine tools, climatización, embalaje, chemical automation equipment
- Guía de solución de problemas
- Trips immediately upon motor start: Usually short-circuit trip. Check motor windings and cables for phase-to-phase or earth short circuit.
- Trips after running for some time: Sobrecarga. Recheck motor rated current and reset the adjustment knob; inspect for mechanical jamming.
- no se puede cerrar: Fallo del mecanismo, or previous short-circuit trip not fully reset. Press TEST button to reset before closing.
- Second-hand Inspection Checklist
- Apariencia: No cracked housing, burn marks, or overheating discoloration on terminals
- Mechanical operation: Smooth handle operation; TEST button triggers trip correctly and resets properly
- Continuidad: Main contacts conduct when closed and isolate when open; no internal short circuit
- Aislamiento: Measure insulation resistance between phases and to earth using a megger
Siemens 3RV2031-4KA10 (Marco S2) Dimensiones de instalación
All 3RV2031 models of frame S2 share identical outer dimensions
Unit Overall Dimensions (Ancho × Alto × Fondo)
Ancho W: 55 milímetros (55mm cabinet space per unit)
Altura H: 140 milímetros
Profundidad D: 149 milímetros (from rail mounting surface to front of operating handle)
Método de montaje
Carril: DIN 35mm standard rail (TU ÚNICO 60715), montaje con clip; optional screw locking
Orientación de montaje: any orientation (vertical, horizontal installation allowed)
Cabinet Clearances (Disipación de calor / Electrical clearance)
Side-by-side mounting: 0mm gap allowed for adjacent units
Vertical clearance top & abajo: ≥50mm at upper/lower terminal zones
Clearance to earthed cabinet metalwork: ≥10mm lateral clearance
Cabinet cutout (if door extension handle is used)
The 3RV2 unit is DIN-rail mounted inside the cabinet. If an extended door operating handle (se vende por separado) se requiere:
Cutout width: aprox. 48milímetros, cutout height: aprox. 130milímetros
Nota: No cabinet cutout required without extension handle; unit is fully installed inside enclosure on DIN rail.
Notas complementarias
With 3RV2901 side-mounted auxiliary contact: overall width unchanged, slight increase in depth
When back-to-back assembled with 3RT contactor as starter: total depth equals sum of both components
Siemens 3RV2031-4KA10 Weight
✅ Net weight (unit only, no packaging): 1.17 kilos (manufacturer nominal 1.172 kilos; use 1.17kg on engineering drawings)
All S2 frame 3RV2031 models have similar weight, range 1.07~1.18 kg. Variations come from internal trip components; standard value for 3RV2031-4KA10 is 1.17 kilos.
Notas complementarias
- Sin accesorios: No 3RV2901 auxiliary contacts, door extension handles or other attachments. Weight increases slightly when accessories are fitted.
- Gross weight with factory carton: aprox. 1.30 kilos (for logistics estimation)
- Unit conversion: 1.17 kg ≈ 2.58 libras
Siemens 3RV2031-4KA10|Cross-brand Comparison + MPCB Product Series List
Reference device: 3RV2031-4KA10, frame S2, 55mm de ancho, 3PAG, 62~73A, terminales de tornillo, Class10, Icu@400V=65kA, sin contactos auxiliares incorporados, for 37kW@400V motor
⚠️ Important notice: No fully pin-to-pin drop-in replacement available. The below are function/rating/frame equivalent selections. Cabinet mounting, accesorios, breaking capacity and instantaneous trip values must be verified. Protection coordination validation is mandatory before formal project replacement.
- Siemens Internal Cross-reference (Preferred Replacement)
| Modelo | Descripción | Difference vs 3RV2031-4KA10 |
| 3RV2031-4KA10 | Reference unit, imported Germany frame S2, 62~73A, terminales de tornillo, sin contactos auxiliares incorporados | Base unit |
| 3RV2031-4KA15 | Misma calificación actual, fitted with 1NO+1NC auxiliary contacts | Comes with built-in aux contacts; rest parameters identical |
| 3RV5031-4KA10 | Siemens China local frame S2, 62~73A screw terminals | Parameters largely identical, slightly lower Icu, economical domestic version |
| 3RV1031-4KA10 | Legacy 3RV1 frame S2, same current rating | Older generation, eliminado gradualmente; similar outline but accessories not fully compatible |
3RV2 frame size overview
S00: 45milímetros, max 16A, motor ≤7.5kW
S0: 45milímetros, max 40A, motor ≤18.5kW
T2: 55milímetros, max 80A, motor ≤37kW (frame of this model)
T3: 70milímetros, max 100A, motor ≤45~55kW
- Imported Brand Equivalent Cross-reference (62~73A, S2 frame class MPCB)
| Marca | Serie de productos | Modelo equivalente | Key Parameter Notes & Diferencias |
| Schneider | TeSys GV3 (GV3ME) | GV3ME80 | 56~80A adjustable, rotary knob, 3PAG, terminales de tornillo; 55marco de mm, Class10. GV2 max 40A, GV2 cannot replace this model. Icu to be checked; instantaneous trip differs from Siemens |
| TEJIDO | MS series motor protection circuit breaker | MS165-73 | 60~73A adjustable, 3PAG, Carril DIN, 55marco de mm; MS165 is ABB equivalent to S2 frame. MS132 max 32A, insufficient rating, not suitable |
| Eaton (Möller) | PKZ2 motor protector | PKZ2-73 | 62~73A, 3PAG, rotary operation, S2 frame, Class10. PKZ1 small frame; PKZ2 corresponds to 3RV2 S2 |
| Omrón | BM series motor protection breaker | BM6R-63 | Adjustment range near 62~73A, 3PAG; limited domestic adoption, verify breaking capacity during selection |
- Alternativas de marcas nacionales (Cost Reduction for Projects)
| Marca | Serie | Modelo equivalente | Observaciones |
| chint | NS2 series | NS2-80 62~73A | NS2 motor protection breaker, 55milímetros, Class10, terminales de tornillo |
| Delicioso | CDV6 series | CDV6-80 62~73A | Same function MPCB, economical domestic type, lower Icu vs imported brands |
| Nader | NDM2-M | NDM2-M80 62~73A | High-end industrial domestic, mayor capacidad de rotura, suitable for critical circuits |
- MPCB Product Portfolio Overview by Brand (Thermal-Magnetic DIN Rail Motor Protection Circuit Breaker)
siemens
3RV2 (SIRIUS main import range: S00/S0/S2/S3, 0.1~100A)
3RV5 / 3RV6 (domestic economical range, S00/S0/S2)
3RV1 (modelo heredado, eliminación gradual)
3VU (old compact type, max 63A)
Schneider
GV2: Small frame 45mm, 0.1~40A
GV3: Medium frame 55mm, 40~80A (counterpart to 3RV2 S2)
GV7: Large frame, 80~150A
TEJIDO
MS116: Small frame
MS132: Marco mediano, max 32A
MS165: 55mm frame up to 80A (counterpart to 3RV2 S2)
MO series (high breaking capacity version)
Eaton (Möller)
PKZ0 / PKZ1: Low current
PKZ2: S2 frame up to 80A
PKZ3: Large frame
Main Domestic Brands
Chint NS2
Delixi CDV6
Nader NDM2-M
Changshu CM1-M (motor protection variant)
- Risks for Replacement Selection (Critical for Engineering)
- Different instantaneous short-circuit trip (N factor): 3RV2031-4KA10 fixed at 949A. Schneider GV3 and ABB MS165 have different electromagnetic trip thresholds. Short-circuit protection coordination changes. Direct replacement may cause loss of selectivity.
- Capacidad de rotura máxima Icu: 3RV2 is 65kA@400V. Domestic models generally have lower Icu and shall NOT be used for circuits with high prospective short-circuit current.
- Enclavamiento mecánico & contactor assembly: 3RV2 can directly snap onto 3RT contactor to form starter. Cross-brand devices cannot mechanically clip together, separate mounting brackets required.
- Auxiliary contact accessory systems are incompatible; mounting depth, terminal torque and maximum cable cross-section differ.
- UL/CE certification: No arbitrary brand replacement for export machines.
- Recommended Selection Rules
Cabinet retrofit, modificación mínima: Siemens 3RV5031-4KA10 (domestic same-brand replacement)
Import brand substitution: Schneider GV3ME80 / ABB MS165-73, short-circuit protection coordination recheck required
Non-critical domestic circuit cost saving: Chint NS2-80 / Delixi CDV6-80
contactor,cortacircuitos,sensor,Codificador,SOCIEDAD ANÓNIMA,Convertidor