Tipo de producto: SIRIUS 3RV2 series frame S2 motor protection circuit breaker (protector de motor), active production model, made in Germany Model Code Explanation 3RV 2 0 31 4 K A 10 3RV: SIRIUS motor protection circuit breaker 2: 2nd generation of 3RV2 series 0: Versión estándar, no pre-fitted auxiliary contacts 31: Frame size S2 4: Viaje ...

  • Detalles del producto

Tipo de producto: SIRIUS 3RV2 series frame S2 disyuntor de protección del motor (protector de motor), active production model, hecho en alemania

  1. Explicación del código del modelo

3RV 2 0 31 4 K A 10

3RV: SIRIUS motor protection circuit breaker

2: 2nd generation of 3RV2 series

0: Versión estándar, no pre-fitted auxiliary contacts

31: Frame size S2

4: Trip current rating code

k: Thermal setting range 62~73A

A: Terminales de tornillo

10: Capacidad de ruptura estándar (without additional contacts)

  1. Datos técnicos básicos
ArtículoPresupuesto
Tamaño del marcoT2, width 55mm, Montaje en carril DIN
polacos3PAG
Rango de ajuste de sobrecarga térmica62 ~ 73A (adjustable via front knob)
Instantaneous electromagnetic short-circuit trip949A (fijado)
clase de viajeClase 10 (for normal motor starting; trips within 10s at 7.2× rated current)
Tensión operativa nominalCA 690V, CC 250 V.
Rated ultimate short-circuit breaking capacity Icu@400V65el
Tipo de conexiónTerminales de tornillo
Contactos auxiliares incorporadosNinguno; auxiliary contact modules must be fitted separately
Potencia del motor aplicable (CA 400 V.)Aprox.. 37kW 3-phase motor
Peso neto1.172kilos
Código Aduanero SA85362090
  1. Funciones de protección
  2. Protección contra sobrecarga: Inverse-time thermal trip via bimetallic strip, motor overload protection and phase loss protection
  3. Protección contra cortocircuitos: Instantaneous electromagnetic trip for rapid short-circuit disconnection
  4. Front-mounted TEST pushbutton for manual tripping test of the mechanism
  5. Handle position indication: EN / APAGADO / fault trip position; padlockable for lockout
  6. Alambrado & Especificaciones de instalación

Main circuit conductor: máx.. 1×35mm² solid/stranded cable; máximo. 1×25mm² fine-stranded cable with ferrule

Par de apriete para terminales principales: 3.0~4.5 N·m, tornillos m6

Accepts top-in or bottom-in wiring; DIN35mm rail mounting

Can be assembled with SIRIUS 3RT contactor to form a direct-on-line starter, constituting a motor protection starter unit

  1. Selección & Información de reemplazo

Same-series Replacement (Misma calificación)

3RV2031-4KA15: Version with pre-fitted auxiliary contacts (1NO+1NC)

Nota: 3RV2031-4KA10 has no built-in auxiliary contacts. For feedback signals, 3RV2901 auxiliary contact accessory must be mounted externally.

Referencia alternativa nacional

siemens local China 3RV5/3RV6 series equivalent: 3RV5031-4KA10 (domestic frame S2, 62~73A, terminales de tornillo, largely identical parameters)

  1. Aplicaciones típicas

3-motores asíncronos de fase, fans, bombas de agua, compresores, protección del circuito del motor del transportador

Circuitos de arranque de motor dentro de gabinetes de control., combinado con contactores como conjuntos de arranque

Protección de motores para máquinas herramienta., climatización, embalaje, equipo de automatización química

  1. Guía de solución de problemas
  2. Se dispara inmediatamente después del arranque del motor.: Generalmente disparo por cortocircuito. Compruebe los devanados y cables del motor en busca de cortocircuito entre fases o a tierra..
  3. Tropiezos después de correr durante algún tiempo.: Sobrecarga. Vuelva a verificar la corriente nominal del motor y reinicie la perilla de ajuste.; inspeccionar para detectar atascos mecánicos.
  4. no se puede cerrar: Fallo del mecanismo, o el disparo por cortocircuito anterior no se restableció completamente. Presione el botón TEST para restablecer antes de cerrar..
  5. Lista de verificación de inspección de segunda mano
  6. Apariencia: Sin carcasa agrietada, marcas de quemaduras, o decoloración por sobrecalentamiento en los terminales
  7. Operación mecánica: Operación suave del mango; El botón TEST activa el disparo correctamente y se reinicia correctamente
  8. Continuidad: Los contactos principales conducen cuando están cerrados y aíslan cuando están abiertos.; sin cortocircuito interno
  9. Aislamiento: Mida la resistencia de aislamiento entre fases y a tierra usando un megger

Siemens 3RV2031-4KA10 (Marco S2) Dimensiones de instalación

Todos los modelos 3RV2031 de bastidor S2 comparten dimensiones exteriores idénticas

Dimensiones generales de la unidad (Ancho × Alto × Fondo)

Ancho W: 55 milímetros (55mm de espacio en gabinetes por unidad)

Altura H: 140 milímetros

Profundidad D: 149 milímetros (desde la superficie de montaje del riel hasta el frente de la manija de operación)

Método de montaje

Carril: Carril estándar DIN de 35 mm (TU ÚNICO 60715), montaje con clip; bloqueo de tornillo opcional

Orientación de montaje: cualquier orientación (vertical, Se permite la instalación horizontal.)

Espacios libres del gabinete (Disipación de calor / Liquidación eléctrica)

Montaje lado a lado: 0mm de espacio permitido para unidades adyacentes

Parte superior con espacio libre vertical & abajo: ≥50 mm en las zonas terminales superior/inferior

Distancia a la estructura metálica del gabinete conectada a tierra: Espacio libre lateral ≥10 mm

Recorte del gabinete (si se utiliza la manija de extensión de la puerta)

La unidad 3RV2 está montada en carril DIN dentro del gabinete.. Si una manija de operación de puerta extendida (se vende por separado) se requiere:

Ancho de corte: aprox. 48milímetros, altura de corte: aprox. 130milímetros

Nota: No se requiere recorte en el gabinete sin manija de extensión; unit is fully installed inside enclosure on DIN rail.

Notas complementarias

With 3RV2901 side-mounted auxiliary contact: overall width unchanged, slight increase in depth

When back-to-back assembled with 3RT contactor as starter: total depth equals sum of both components

Siemens 3RV2031-4KA10 Weight

✅ Net weight (unit only, no packaging): 1.17 kilos (manufacturer nominal 1.172 kilos; use 1.17kg on engineering drawings)

All S2 frame 3RV2031 models have similar weight, range 1.07~1.18 kg. Variations come from internal trip components; standard value for 3RV2031-4KA10 is 1.17 kilos.

Notas complementarias

  1. Sin accesorios: No 3RV2901 auxiliary contacts, door extension handles or other attachments. Weight increases slightly when accessories are fitted.
  2. Gross weight with factory carton: aprox. 1.30 kilos (for logistics estimation)
  3. Unit conversion: 1.17 kg ≈ 2.58 libras

Siemens 3RV2031-4KA10|Cross-brand Comparison + MPCB Product Series List

Reference device: 3RV2031-4KA10, frame S2, 55mm de ancho, 3PAG, 62~73A, terminales de tornillo, Clase 10, Icu@400V=65kA, sin contactos auxiliares incorporados, for 37kW@400V motor

⚠️ Important notice: No fully pin-to-pin drop-in replacement available. The below are function/rating/frame equivalent selections. Montaje en gabinete, accesorios, breaking capacity and instantaneous trip values must be verified. Protection coordination validation is mandatory before formal project replacement.

  1. Siemens Internal Cross-reference (Reemplazo preferido)
ModeloDescripciónDifference vs 3RV2031-4KA10
3RV2031-4KA10Unidad de referencia, imported Germany frame S2, 62~73A, terminales de tornillo, sin contactos auxiliares incorporadosUnidad básica
3RV2031-4KA15Misma calificación actual, fitted with 1NO+1NC auxiliary contactsComes with built-in aux contacts; parámetros de resto idénticos
3RV5031-4KA10Siemens China local frame S2, 62~73A screw terminalsParameters largely identical, slightly lower Icu, economical domestic version
3RV1031-4KA10Legacy 3RV1 frame S2, misma calificación actualOlder generation, eliminado gradualmente; similar outline but accessories not fully compatible

3RV2 frame size overview

S00: 45milímetros, max 16A, motor ≤7.5kW

S0: 45milímetros, max 40A, motor ≤18.5kW

T2: 55milímetros, max 80A, motor ≤37kW (frame of this model)

T3: 70milímetros, max 100A, motor ≤45~55kW

  1. Imported Brand Equivalent Cross-reference (62~73A, S2 frame class MPCB)
MarcaSerie de productosModelo equivalenteKey Parameter Notes & Diferencias
SchneiderTeSys GV3 (GV3ME)GV3ME8056~80A adjustable, mando giratorio, 3PAG, terminales de tornillo; 55marco de mm, Clase 10. GV2 max 40A, GV2 cannot replace this model. Icu to be checked; instantaneous trip differs from Siemens
TEJIDOMS series motor protection circuit breakerMS165-7360~73A adjustable, 3PAG, Carril DIN, 55marco de mm; MS165 is ABB equivalent to S2 frame. MS132 max 32A, insufficient rating, not suitable
Eaton (Möller)PKZ2 motor protectorPKZ2-7362~73A, 3PAG, rotary operation, S2 frame, Clase 10. PKZ1 small frame; PKZ2 corresponds to 3RV2 S2
OmrónBM series motor protection breakerBM6R-63Adjustment range near 62~73A, 3PAG; limited domestic adoption, verify breaking capacity during selection
  1. Alternativas de marcas nacionales (Cost Reduction for Projects)
MarcaSerieModelo equivalenteObservaciones
chintNS2 seriesNS2-80 62~73ANS2 motor protection breaker, 55milímetros, Clase 10, terminales de tornillo
DeliciosoCDV6 seriesCDV6-80 62~73ASame function MPCB, economical domestic type, lower Icu vs imported brands
NaderNDM2-MNDM2-M80 62~73AHigh-end industrial domestic, mayor capacidad de rotura, suitable for critical circuits
  1. MPCB Product Portfolio Overview by Brand (Thermal-Magnetic DIN Rail Motor Protection Circuit Breaker)

siemens

3RV2 (SIRIUS main import range: S00/S0/S2/S3, 0.1~100A)

3RV5 / 3RV6 (domestic economical range, S00/S0/S2)

3RV1 (modelo heredado, eliminación gradual)

3VU (old compact type, máx. 63A)

Schneider

GV2: Small frame 45mm, 0.1~40A

gv3: Medium frame 55mm, 40~80A (counterpart to 3RV2 S2)

GV7: Marco grande, 80~150A

TEJIDO

MS116: Marco pequeño

MS132: Marco mediano, max 32A

MS165: 55mm frame up to 80A (counterpart to 3RV2 S2)

MO series (high breaking capacity version)

Eaton (Möller)

PKZ0 / PKZ1: Baja corriente

PKZ2: S2 frame up to 80A

PKZ3: Marco grande

Main Domestic Brands

Chint NS2

Delixi CDV6

Nader NDM2-M

Changshu CM1-M (motor protection variant)

  1. Risks for Replacement Selection (Critical for Engineering)
  2. Different instantaneous short-circuit trip (N factor): 3RV2031-4KA10 fixed at 949A. Schneider GV3 and ABB MS165 have different electromagnetic trip thresholds. Cambios en la coordinación de la protección contra cortocircuitos.. El reemplazo directo puede causar pérdida de selectividad..
  3. Capacidad de rotura máxima Icu: 3RV2 es 65 kA a 400 V. Los modelos domésticos generalmente tienen una Icu más baja y NO deben usarse para circuitos con alta posible corriente de cortocircuito..
  4. Enclavamiento mecánico & conjunto de contactores: 3RV2 puede encajar directamente en el contactor 3RT para formar un arrancador. Los dispositivos de varias marcas no se pueden unir mecánicamente, Se requieren soportes de montaje separados..
  5. Los sistemas de accesorios de contactos auxiliares son incompatibles; profundidad de montaje, El par de apriete y la sección transversal máxima del cable difieren.
  6. Certificado UL/CE: No hay reemplazo arbitrario de marca para las máquinas de exportación.
  7. Reglas de selección recomendadas

Modernización del gabinete, modificación mínima: Siemens 3RV5031-4KA10 (reemplazo nacional de la misma marca)

Importar sustitución de marca: Schneider GV3ME80 / ABB MS165-73, Se requiere una nueva verificación de la coordinación de la protección contra cortocircuitos.

Ahorro de costes en circuitos domésticos no críticos: Chint NS2-80 / Delixi CDV6-80