A classic motor protection series from Schneider Electric, designed for low-power motors rated 0.1-32A. It provides protection against short circuit, overload and phase loss. Equipped with a rotary knob for manual closing and tripping, and built-in thermal-magnetic trip unit to deliver delayed overload protection and instantaneous short-circuit protection. The code 10 represents an adjustable setting ...

  • Detalles del producto

A classic motor protection series from Schneider Electric, designed for low-power motors rated 0.1-32A. It provides protection against short circuit, overload and phase loss. Equipped with a rotary knob for manual closing and tripping, and built-in thermal-magnetic trip unit to deliver delayed overload protection and instantaneous short-circuit protection. The code 10 represents an adjustable setting current range of 4-6.3A, compatible with 1.5-2.2kW three-phase motors at 400V. Models suffixed with C are domestic versions, while those without C are imported versions. Both share identical performance parameters and comply with IEC and GB standards.

  1. Explicación del código del modelo
SegmentoGV2P.M10do
SignificadoSerie de productos: TeSys Deca GV2 disyuntor de motoresOperation type: Panel Mount Rotary Knob with thermal-magnetic protectionSetting current range code: 4-6.3AOrigin code: Manufactured in China
  1. Especificaciones técnicas principales
CategoríaDatos técnicosObservaciones
Información general
Nombre del productoTeSys Deca GV2PM Motor Circuit BreakerSpecifically designed for motor control and protection
Código de pedidoGV2PM10CStandard commercial model
Estado del productoActivoStandard product of Schneider Electric
Parámetros eléctricos
polacos3PAG (trifásico)Para motores asíncronos trifásicos
Configuración del rango actual4-6.3AAdjustable via rotary knob, for 1.5-2.2kW motors (400V)
Corriente operativa nominal (Ith)6.3ACorriente máxima de funcionamiento continuo
Tensión nominal de aislamiento (interfaz de usuario)690VWithstand voltage level of insulation system
Tensión operativa nominal (ue)400V y (50/60Hz)Standard industrial voltage
Capacidad de ruptura máxima nominal en cortocircuito (uci)100kA @ 400VCumple con IEC 60947-2
Tipo de protecciónTermo-magnéticoDelayed overload protection + protección instantánea contra cortocircuitos
Parámetros mecánicos
Dimensiones (Ancho×Alto×Profundidad)89mm×85mm×91mmCompact structure to save cabinet space
PesoAprox.. 280gramoEasy for installation and maintenance
Montaje35mm montaje en carril DINCumple con EN 60715
TerminalesTerminales de tornillo, for 1.5-4mm² conductorsSuitable for solid and stranded wires
Modo de operaciónRotary knob (OFF-ON-RESET)Manual reset required after tripping
Parámetros ambientales
Temperatura de funcionamiento-20°C ~ +60°CAdaptable to industrial environments
Protección de ingresoIP20Prevents finger access to live parts
CertificacionesCE, CCC, UL, CSACumple con los estándares internacionales de seguridad.
  1. Full Range of GV2PM Rotary Knob Motor Circuit Breakers
ModeloConfiguración del rango actualPotencia del motor adaptada (400V)Observaciones
GV2PM01C0.1-0.16A0.025-0.04kilovatiosMinimum current rating
GV2PM02C0.16-0.25A0.04-0.06kilovatios
GV2PM03C0.25-0.4A0.06-0.1kilovatios
GV2PM04C0.4-0.63A0.1-0.16kilovatios
GV2PM05C0.63-1A0.16-0.25kilovatios
GV2PM06C1-1.6A0.25-0.4kilovatios
GV2PM07C1.6-2.5A0.4-0.63kilovatios
GV2PM08C2.5-4A0.63-1.1kilovatios
GV2PM10C4-6.3A1.1-2.2kilovatiosModelo actual
GV2PM14C6.3-10A2.2-3kilovatios
GV2PM16C9-14A3-4kilovatios
GV2PM20C13-18A4-5.5kilovatios
GV2PM21C17-23A5.5-7.5kilovatios
GV2PM22C23-32A7.5-11kilovatiosMaximum current rating
  1. Competidor & Modelos equivalentes
MarcaModeloConfiguración del rango actualModo de operaciónDescripción de reemplazo
Electricidad SchneiderGV2ME10C4-6.3APush-buttonAlternative with different operation mode within the same series
siemens3RV2011-0JA104-6.3ARotary knobCross-brand functional replacement
TEJIDOMS116-6.34-6.3ARotary knobCross-brand functional replacement
EatonDIL M9-104-6.3ARotary knobCross-brand functional replacement
chintNDM1-63/33004-6.3ARotary knobEconomical domestic alternative
  1. Entornos de aplicación & Casos típicos

5.1 Aplicaciones recomendadas

Automatización Industrial: Protection for small pumps, fans and conveyor motors; compatible with PLC control circuits

Instalaciones del edificio: Control and protection for air conditioning fans, bombas de agua, elevator door motors and fire linkage equipment

Alimento & Beverage Industry: Motor protection for packaging machines, filling machines and small mixers; meets hygiene requirements

Equipo médico: Safety protection for laboratory stirrers, centrifuges and small medical pumps

Maquinaria agrícola: Protection for outdoor motors such as irrigation pumps, small harvesters and feed mixers

Centros de datos: Protection for precision air conditioner fans, cooling water pumps and UPS cooling fans

5.2 Non-recommended Applications

arranque frecuente: Not applicable for equipment starting more than 10 veces por hora. GV3 series or soft starters are recommended instead.

Heavy-duty start: Not suitable for motors with starting current over 8 veces la corriente nominal. Additional overload protection is required.

Explosive hazardous areas: No explosion-proof certification. Do not use directly in Zone IIC explosive areas.

DC motors: The GV2 series is designed exclusively for AC motors. Use dedicated protective devices for DC motors.

5.3 Casos de aplicación típicos

Caso 1: Mixing System in Pharmaceutical Factory

Solicitud: Sobrecarga, short-circuit and phase loss protection for 1.5kW reactor stirring motors

Configuración: GV2PM10C + LC1D12 Contactor + Control Buttons

Beneficios: Prevents motor burnout caused by agitator jamming; complies with GMP standards and trips rapidly for equipment protection during faults.

Caso 2: Air Conditioning System in Commercial Buildings

Solicitud: Protection and control for 2.2kW fresh air handling units and water pump motors

Configuración: GV2PM10C + Building Automation System (BAJO) + Sensores de temperatura

Beneficios: Enables automatic start/stop of fans and pumps, protects motors against overload, reduces maintenance costs and improves energy efficiency by 12%.

Caso 3: Conveyors on Automated Production Lines

Solicitud: Protection and control for 1.1kW small conveyor motors

Configuración: GV2PM10C + SOCIEDAD ANÓNIMA + Emergency Stop Buttons

Beneficios: Avoids motor damage from conveyor jamming, works with emergency stop system for safe shutdown, and shortens Mean Time To Repair (MTTR) to within 3 minutos.

Caso 4: Aeration System in Wastewater Treatment Plant

Solicitud: Protection and control for 2.2kW small aeration fans

Configuración: GV2PM10C + Liquid Level Sensors + Automatic Control Cabinet

Beneficios: Performs reliably in humid environments, prevents fan burnout from overload, realizes unattended automatic operation and cuts operational costs by 30%.

  1. Consejos de selección & Quick Reference Rules

Selection Rhythm

Choose GV2PM10C,

Rango actual 4 to 6.3A,

Matches motors 1.5 to 2.2kW,

Rotary knob operation, IP20 rating,

35carril DIN mm, 89mm de ancho,

High breaking capacity with thermal-magnetic protection,

Safeguards motors from overload and short circuit,

Reliable for industrial and building applications.

Quick Reference Rules

  1. Coincidencia actual: 10 = 4-6.3A; 08 = 2.5-4A; 14 = 6.3-10A. Larger figure means wider current range.
  2. Modo de operación: PM = Rotary knob; ME = Push-button; LP = Magnetic-only type (short-circuit protection only).
  3. Coincidencia de poder: 4-6.3A corresponds to 1.5-2.2kW @ 400V. Approximate formula: Current × 0.5 ≈ Matched motor power (kilovatios).
  4. Installation Features: 89mm de ancho, 35mm montaje en carril DIN, Grado de protección IP20, ideal for installation inside control cabinets.
  5. Solución de problemas
Fenómeno de fallaPosibles causasSoluciones
Tropiezos frecuentesSetting current too lowTurn the rotary knob clockwise to increase current within 4-6.3A
Motor overload / rotor bloqueadoCheck for overloading and eliminate jamming
Phase loss operationInspect three-phase power supply and repair broken wires or poor contacts
No cerrarKnob not resetTurn the knob to OFF position then back to ON after tripping
Atasco mecánicoClear foreign objects or replace damaged components
Cableado incorrectoRecheck three-phase wiring and eliminate short circuits
Overheated contactsTerminales de cableado flojosRetighten terminals for good contact
Excessive loadReduce load or replace with higher-rated circuit breaker if needed
Temperatura ambiente excesivamente altaImprove ventilation and keep temperature below 60°C
  1. Key Features Summary
  2. Protección Integral: Thermal-magnetic trip unit provides delayed overload, instantaneous short-circuit and phase loss protection, Cumple con IEC 60947-4-1.
  3. Amplia compatibilidad: 4-6.3A adjustable current range for 1.5-2.2kW three-phase motors; easy operation via rotary knob.
  4. Estructura compacta: Dimension 89mm×85mm×91mm with 35mm DIN rail mounting to save cabinet space.
  5. Alta confiabilidad: Wide operating temperature range (-20°C ~ +60°C) and IP20 rating for harsh industrial conditions.
  6. Fácil instalación & Mantenimiento: Standard interface for seamless matching with contactors; simple knob reset after faults.

Application Scenarios of Schneider GV2PM10C (4~6.3A)

This is a 3-pole rotary-knob motor circuit breaker with thermal-magnetic protection. It is suitable for 1.1~2.2kW three-phase asynchronous motors at 400V. Adopting DIN rail mounting, it integrates overload, short-circuit and phase loss protection, and is widely used in industrial, edificio, light industry and municipal fields.

  1. Principales escenarios de aplicación

1.1 Industrial Automated Production Lines

Small belt conveyors and roller motors

Workshop auxiliary fans and dust extraction fans

Auxiliary power motors for manipulators and small positioners

Machine tool cooling pumps and lubrication pumps

Combined with PLC and relay circuits for local and remote control & protección

1.2 climatización & Building Electromechanical Systems

Terminal fans, fresh air fans and exhaust fans of central air conditioning

Small circulating water pumps and make-up water pumps for building water supply & drenaje

Cooling fans for computer room precision air conditioners

Auxiliary fans and door drive motors in elevator rooms

Fire exhaust fans and damper linkage motors (meeting fire power distribution standards)

1.3 Industria ligera, Alimento & Industria del embalaje

Small mixers, blenders and feeding machines

Packaging machines, labelers and conveyor drive motors

Filling equipment and small roller conveyors

Ventilation fans and washing pumps for food workshops

(Compact body and qualified protection level, suitable for dusty and humid workshop conditions)

1.4 Tratamiento de agua & Municipal Engineering

Small aeration fans, dosing pumps and reflux pumps in sewage treatment plants

Booster pumps for landscape pools and residential water supply

Small power motors inside on-site control boxes of pumping stations

Fans and water pumps supporting river and pipeline monitoring equipment

1.5 Laboratory & Medical Supporting Equipment

Laboratory stirrers, centrifuges and circulating water pumps

Exhaust and fresh air system motors for medical clean rooms

Medical water purifiers and small delivery pumps

(Sensitive protection effectively prevents equipment stalling and motor burnout)

1.6 almacenamiento, Logística & Supermarkets

Warehouse ventilation fans and dust removal equipment

Condenser fans and fresh air systems for supermarket refrigeration units

Motors for light sorting lines and small roller conveyors

1.7 Maquinaria agrícola & Outdoor Light-duty Equipment

Small irrigation pumps and spray devices for farmland

Feed mixers and small agricultural ventilation equipment

(Wide temperature adaptability for outdoor simple electrical control boxes)

  1. Escenarios no recomendados
  2. High-frequency starting equipment: Más que 10 starts per hour may cause false tripping. Dedicated starting solutions are recommended.
  3. Heavy-load motors with high starting current: Starting current far exceeds normal level; match with thermal relays and contactors additionally.
  4. Explosive hazardous areas: Without explosion-proof certification, not allowed for direct use in explosive zones.
  5. DC motors and high-power single-phase motors: Designed for three-phase AC motors only.
  6. Environments with long-term temperature above +60°C or strong corrosive gas: Protection accuracy and service life will be reduced.
  7. Common Matching Solutions for On-site Use
  8. Standard motor circuit: GV2PM10C + LC1D Contactor + Push Buttons (Local start & detener)
  9. Automatic control circuit: GV2PM10C + contactor + SOCIEDAD ANÓNIMA (Remote automatic control)
  10. Fire linkage circuit: GV2PM10C + Fire Module + contactor (Fire forced start / forced trip)

Anterior:

Deja una respuesta

Dejar un mensaje