A classic motor protection series from Schneider Electric, designed for low-power motors rated 0.1-32A. It provides protection against short circuit, overload and phase loss. Equipped with a rotary knob for manual closing and tripping, and built-in thermal-magnetic trip unit to deliver delayed overload protection and instantaneous short-circuit protection. The code 10 represents an adjustable setting current range of 4-6.3A, compatible with 1.5-2.2kW three-phase motors at 400V. Models suffixed with C are domestic versions, while those without C are imported versions. Both share identical performance parameters and comply with IEC and GB standards.
- Explicación del código del modelo
| Segmento | GV2 | P.M | 10 | do |
| Significado | Serie de productos: TeSys Deca GV2 disyuntor de motores | Operation type: Panel Mount Rotary Knob with thermal-magnetic protection | Setting current range code: 4-6.3A | Origin code: Manufactured in China |
- Especificaciones técnicas principales
| Categoría | Datos técnicos | Observaciones |
| Información general | ||
| Nombre del producto | TeSys Deca GV2PM Motor Circuit Breaker | Specifically designed for motor control and protection |
| Código de pedido | GV2PM10C | Standard commercial model |
| Estado del producto | Activo | Standard product of Schneider Electric |
| Parámetros eléctricos | ||
| polacos | 3PAG (trifásico) | Para motores asíncronos trifásicos |
| Configuración del rango actual | 4-6.3A | Adjustable via rotary knob, for 1.5-2.2kW motors (400V) |
| Corriente operativa nominal (Ith) | 6.3A | Corriente máxima de funcionamiento continuo |
| Tensión nominal de aislamiento (interfaz de usuario) | 690V | Withstand voltage level of insulation system |
| Tensión operativa nominal (ue) | 400V y (50/60Hz) | Standard industrial voltage |
| Capacidad de ruptura máxima nominal en cortocircuito (uci) | 100kA @ 400V | Cumple con IEC 60947-2 |
| Tipo de protección | Termo-magnético | Delayed overload protection + protección instantánea contra cortocircuitos |
| Parámetros mecánicos | ||
| Dimensiones (Ancho×Alto×Profundidad) | 89mm×85mm×91mm | Compact structure to save cabinet space |
| Peso | Aprox.. 280gramo | Easy for installation and maintenance |
| Montaje | 35mm montaje en carril DIN | Cumple con EN 60715 |
| Terminales | Terminales de tornillo, for 1.5-4mm² conductors | Suitable for solid and stranded wires |
| Modo de operación | Rotary knob (OFF-ON-RESET) | Manual reset required after tripping |
| Parámetros ambientales | ||
| Temperatura de funcionamiento | -20°C ~ +60°C | Adaptable to industrial environments |
| Protección de ingreso | IP20 | Prevents finger access to live parts |
| Certificaciones | CE, CCC, UL, CSA | Cumple con los estándares internacionales de seguridad. |
- Full Range of GV2PM Rotary Knob Motor Circuit Breakers
| Modelo | Configuración del rango actual | Potencia del motor adaptada (400V) | Observaciones |
| GV2PM01C | 0.1-0.16A | 0.025-0.04kilovatios | Minimum current rating |
| GV2PM02C | 0.16-0.25A | 0.04-0.06kilovatios | |
| GV2PM03C | 0.25-0.4A | 0.06-0.1kilovatios | |
| GV2PM04C | 0.4-0.63A | 0.1-0.16kilovatios | |
| GV2PM05C | 0.63-1A | 0.16-0.25kilovatios | |
| GV2PM06C | 1-1.6A | 0.25-0.4kilovatios | |
| GV2PM07C | 1.6-2.5A | 0.4-0.63kilovatios | |
| GV2PM08C | 2.5-4A | 0.63-1.1kilovatios | |
| GV2PM10C | 4-6.3A | 1.1-2.2kilovatios | Modelo actual |
| GV2PM14C | 6.3-10A | 2.2-3kilovatios | |
| GV2PM16C | 9-14A | 3-4kilovatios | |
| GV2PM20C | 13-18A | 4-5.5kilovatios | |
| GV2PM21C | 17-23A | 5.5-7.5kilovatios | |
| GV2PM22C | 23-32A | 7.5-11kilovatios | Maximum current rating |
- Competidor & Modelos equivalentes
| Marca | Modelo | Configuración del rango actual | Modo de operación | Descripción de reemplazo |
| Electricidad Schneider | GV2ME10C | 4-6.3A | Push-button | Alternative with different operation mode within the same series |
| siemens | 3RV2011-0JA10 | 4-6.3A | Rotary knob | Cross-brand functional replacement |
| TEJIDO | MS116-6.3 | 4-6.3A | Rotary knob | Cross-brand functional replacement |
| Eaton | DIL M9-10 | 4-6.3A | Rotary knob | Cross-brand functional replacement |
| chint | NDM1-63/3300 | 4-6.3A | Rotary knob | Economical domestic alternative |
- Entornos de aplicación & Casos típicos
5.1 Aplicaciones recomendadas
Automatización Industrial: Protection for small pumps, fans and conveyor motors; compatible with PLC control circuits
Instalaciones del edificio: Control and protection for air conditioning fans, bombas de agua, elevator door motors and fire linkage equipment
Alimento & Beverage Industry: Motor protection for packaging machines, filling machines and small mixers; meets hygiene requirements
Equipo médico: Safety protection for laboratory stirrers, centrifuges and small medical pumps
Maquinaria agrícola: Protection for outdoor motors such as irrigation pumps, small harvesters and feed mixers
Centros de datos: Protection for precision air conditioner fans, cooling water pumps and UPS cooling fans
5.2 Non-recommended Applications
arranque frecuente: Not applicable for equipment starting more than 10 veces por hora. GV3 series or soft starters are recommended instead.
Heavy-duty start: Not suitable for motors with starting current over 8 veces la corriente nominal. Additional overload protection is required.
Explosive hazardous areas: No explosion-proof certification. Do not use directly in Zone IIC explosive areas.
DC motors: The GV2 series is designed exclusively for AC motors. Use dedicated protective devices for DC motors.
5.3 Casos de aplicación típicos
Caso 1: Mixing System in Pharmaceutical Factory
Solicitud: Sobrecarga, short-circuit and phase loss protection for 1.5kW reactor stirring motors
Configuración: GV2PM10C + LC1D12 Contactor + Control Buttons
Beneficios: Prevents motor burnout caused by agitator jamming; complies with GMP standards and trips rapidly for equipment protection during faults.
Caso 2: Air Conditioning System in Commercial Buildings
Solicitud: Protection and control for 2.2kW fresh air handling units and water pump motors
Configuración: GV2PM10C + Building Automation System (BAJO) + Sensores de temperatura
Beneficios: Enables automatic start/stop of fans and pumps, protects motors against overload, reduces maintenance costs and improves energy efficiency by 12%.
Caso 3: Conveyors on Automated Production Lines
Solicitud: Protection and control for 1.1kW small conveyor motors
Configuración: GV2PM10C + SOCIEDAD ANÓNIMA + Emergency Stop Buttons
Beneficios: Avoids motor damage from conveyor jamming, works with emergency stop system for safe shutdown, and shortens Mean Time To Repair (MTTR) to within 3 minutos.
Caso 4: Aeration System in Wastewater Treatment Plant
Solicitud: Protection and control for 2.2kW small aeration fans
Configuración: GV2PM10C + Liquid Level Sensors + Automatic Control Cabinet
Beneficios: Performs reliably in humid environments, prevents fan burnout from overload, realizes unattended automatic operation and cuts operational costs by 30%.
- Consejos de selección & Quick Reference Rules
Selection Rhythm
Choose GV2PM10C,
Rango actual 4 to 6.3A,
Matches motors 1.5 to 2.2kW,
Rotary knob operation, IP20 rating,
35carril DIN mm, 89mm de ancho,
High breaking capacity with thermal-magnetic protection,
Safeguards motors from overload and short circuit,
Reliable for industrial and building applications.
Quick Reference Rules
- Coincidencia actual: 10 = 4-6.3A; 08 = 2.5-4A; 14 = 6.3-10A. Larger figure means wider current range.
- Modo de operación: PM = Rotary knob; ME = Push-button; LP = Magnetic-only type (short-circuit protection only).
- Coincidencia de poder: 4-6.3A corresponds to 1.5-2.2kW @ 400V. Approximate formula: Current × 0.5 ≈ Matched motor power (kilovatios).
- Installation Features: 89mm de ancho, 35mm montaje en carril DIN, Grado de protección IP20, ideal for installation inside control cabinets.
- Solución de problemas
| Fenómeno de falla | Posibles causas | Soluciones |
| Tropiezos frecuentes | Setting current too low | Turn the rotary knob clockwise to increase current within 4-6.3A |
| Motor overload / rotor bloqueado | Check for overloading and eliminate jamming | |
| Phase loss operation | Inspect three-phase power supply and repair broken wires or poor contacts | |
| No cerrar | Knob not reset | Turn the knob to OFF position then back to ON after tripping |
| Atasco mecánico | Clear foreign objects or replace damaged components | |
| Cableado incorrecto | Recheck three-phase wiring and eliminate short circuits | |
| Overheated contacts | Terminales de cableado flojos | Retighten terminals for good contact |
| Excessive load | Reduce load or replace with higher-rated circuit breaker if needed | |
| Temperatura ambiente excesivamente alta | Improve ventilation and keep temperature below 60°C |
- Key Features Summary
- Protección Integral: Thermal-magnetic trip unit provides delayed overload, instantaneous short-circuit and phase loss protection, Cumple con IEC 60947-4-1.
- Amplia compatibilidad: 4-6.3A adjustable current range for 1.5-2.2kW three-phase motors; easy operation via rotary knob.
- Estructura compacta: Dimension 89mm×85mm×91mm with 35mm DIN rail mounting to save cabinet space.
- Alta confiabilidad: Wide operating temperature range (-20°C ~ +60°C) and IP20 rating for harsh industrial conditions.
- Fácil instalación & Mantenimiento: Standard interface for seamless matching with contactors; simple knob reset after faults.
Application Scenarios of Schneider GV2PM10C (4~6.3A)
This is a 3-pole rotary-knob motor circuit breaker with thermal-magnetic protection. It is suitable for 1.1~2.2kW three-phase asynchronous motors at 400V. Adopting DIN rail mounting, it integrates overload, short-circuit and phase loss protection, and is widely used in industrial, edificio, light industry and municipal fields.
- Principales escenarios de aplicación
1.1 Industrial Automated Production Lines
Small belt conveyors and roller motors
Workshop auxiliary fans and dust extraction fans
Auxiliary power motors for manipulators and small positioners
Machine tool cooling pumps and lubrication pumps
Combined with PLC and relay circuits for local and remote control & protección
1.2 climatización & Building Electromechanical Systems
Terminal fans, fresh air fans and exhaust fans of central air conditioning
Small circulating water pumps and make-up water pumps for building water supply & drenaje
Cooling fans for computer room precision air conditioners
Auxiliary fans and door drive motors in elevator rooms
Fire exhaust fans and damper linkage motors (meeting fire power distribution standards)
1.3 Industria ligera, Alimento & Industria del embalaje
Small mixers, blenders and feeding machines
Packaging machines, labelers and conveyor drive motors
Filling equipment and small roller conveyors
Ventilation fans and washing pumps for food workshops
(Compact body and qualified protection level, suitable for dusty and humid workshop conditions)
1.4 Tratamiento de agua & Municipal Engineering
Small aeration fans, dosing pumps and reflux pumps in sewage treatment plants
Booster pumps for landscape pools and residential water supply
Small power motors inside on-site control boxes of pumping stations
Fans and water pumps supporting river and pipeline monitoring equipment
1.5 Laboratory & Medical Supporting Equipment
Laboratory stirrers, centrifuges and circulating water pumps
Exhaust and fresh air system motors for medical clean rooms
Medical water purifiers and small delivery pumps
(Sensitive protection effectively prevents equipment stalling and motor burnout)
1.6 almacenamiento, Logística & Supermarkets
Warehouse ventilation fans and dust removal equipment
Condenser fans and fresh air systems for supermarket refrigeration units
Motors for light sorting lines and small roller conveyors
1.7 Maquinaria agrícola & Outdoor Light-duty Equipment
Small irrigation pumps and spray devices for farmland
Feed mixers and small agricultural ventilation equipment
(Wide temperature adaptability for outdoor simple electrical control boxes)
- Escenarios no recomendados
- High-frequency starting equipment: Más que 10 starts per hour may cause false tripping. Dedicated starting solutions are recommended.
- Heavy-load motors with high starting current: Starting current far exceeds normal level; match with thermal relays and contactors additionally.
- Explosive hazardous areas: Without explosion-proof certification, not allowed for direct use in explosive zones.
- DC motors and high-power single-phase motors: Designed for three-phase AC motors only.
- Environments with long-term temperature above +60°C or strong corrosive gas: Protection accuracy and service life will be reduced.
- Common Matching Solutions for On-site Use
- Standard motor circuit: GV2PM10C + LC1D Contactor + Push Buttons (Local start & detener)
- Automatic control circuit: GV2PM10C + contactor + SOCIEDAD ANÓNIMA (Remote automatic control)
- Fire linkage circuit: GV2PM10C + Fire Module + contactor (Fire forced start / forced trip)
contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares