✅ Explicación del código del modelo
| Segmento | Definición |
| 6SE6440 | MM440 universal inverter serie |
| 2 | Built-in Basic Operator Panel (BOP), no AOP |
| Ud. | 200~240V single-phase / three-phase universal input (1AC/3AC) |
| do | No integrated EMC filter |
| 15 | 0.55potencia nominal en kW |
| 5AA1 | Versión estándar, filterless, frame size A |
📋 Key Technical Specifications
Potencia nominal: 0.55 kilovatios (Torque constante)
Voltaje de entrada: AC 200–240V ±10%, 47–63Hz, compatible with single-phase or three-phase input
Corriente de salida nominal: 3.0 A
Capacidad de sobrecarga: 150% para los 60; 200% por 3s
Clase de protección: IP20
Dimensiones generales(Alto×Ancho×Profundidad): 173 × 73 × 149 milímetros (Frame Size A)
Peso neto: aprox. 1.3 kilos
Temperatura ambiente: -10 ~ +50℃ (no power derating)
Modos de control: Control V/F, control de vectores, PID incorporado, Compatible con Modbus RTU
Standard Equipment: BOP panel; no integrated EMC filter
📌 Product Lifecycle
MM440 discontinued in 2019, available only as spare parts. No mass-production new units. Stock new units or used refurbished units circulate in the market.
🔄 Replacement Selection
- Direct replacement series: G120 Inverter
Recomendado: 6SL3210-1PB13-0UL0 (0.55kW 220V, without filter), BOP-2 panel to be ordered separately.
- Retrofit Note: Terminal definitions and parameter systems differ between MM440 and G120. Control logic and parameters require full re-commissioning.
🛠 Typical Applications
Cintas transportadoras, pequeños fans & bombas de agua, mezcladores, pequeño equipo de transporte, maquinaria de embalaje. Suitable for speed regulation of 0.55kW, 220V AC asynchronous motors.
📎 Optional Accessories
BOP: 6SE6400-0BP00-0AA1 (factory fitted)
AOP Advanced Operator Panel: 6SE6400-0AP00-0AA1
Filtro CEM: 6SE6400-2FA00-6AD0
Resistencia de frenado: Optional as required (usually unnecessary for 0.55kW low power)
⚠️ Troubleshooting Summary (General for MM440)
- F0001 Overcurrent: Cortocircuito del motor, cable dañado, falla a tierra, falla del módulo de potencia
- F0002 Overvoltage: desaceleración rápida, grid surge; braking resistor may be required
- F0003 Undervoltage: Falta fase de entrada, caída de voltaje
- F0011 Overtemperature: Blocked cooling channel, temperatura ambiente excesiva, fan damage
Código HS
85044084 (Static converters, frequency inverters)
siemens 6SE6440-2UC15-5AA1 (MM440, 220V 0.55kW) Escenarios de aplicación
Características principales: Single/three-phase 220V power supply, control de vectores, PID incorporado, Modbus RTU, stable speed regulation at low torque. Power limited to 0.55kW, only compatible with small-load motors, widely used for stand-alone small automation equipment retrofit and spare part replacement for legacy machines.
- Transporte de materiales (Más común)
- Cintas transportadoras pequeñas, transportadores de rodillos: Short packaging line conveyors, laboratory transport tables, small sorting branch lines. Soft start & soft stop prevent material slipping or tipping; multi-speed function available.
- Small hoists / miniature winches: Light-duty lifting mechanisms. MM440 vector control delivers stable low-speed torque for light-load lifting within 0.55kW power limit.
- Fluid Equipment (aficionados & Zapatillas, PID for constant pressure/flow)
- Pequeños ventiladores centrífugos, duct exhaust fans: Workshop local exhaust, oven circulation fans; energy saving via variable speed drive.
- Mini water pumps, bombas dosificadoras: Suministro de agua a presión constante, chemical dosing pumps. Built-in PID performs closed-loop constant pressure/flow control with 4-20mA analog feedback.
Advantage for low-flow cases: 220V single-phase power input, preferred where 380V three-phase power is unavailable on site.
III. Embalaje & Light Industrial Machinery
- Pequeñas máquinas de embalaje: Film feeding for pillow packaging, label feed motors, screw bottle separation drive. Smooth start-stop and PLC-linked speed control.
- Food light industry equipment: Small mixing tanks, licuadoras, extrusion actuators (0.55kW small mixing motors), auxiliary drives for food production lines.
- Textile auxiliary machines: Small rewind/unwind units for simple tension control.
- Máquinas herramienta & Automation Auxiliary Equipment
- Machine tool auxiliary drives: Coolant pumps, small lubrication pumps, auxiliary table feed motors.
- Mesas giratorias, indexing turntables: Stable low-speed rotation for point positioning.
- Automation training benches / teaching equipment: Classic MM440 teaching unit for colleges, used to learn vector control, Modbus communication and multi-speed programming.
- climatización, Edificio & Other Auxiliary Systems
- Small air damper actuators, fresh air units
- Gate valves, small roller shutter drives: Speed control for workshop small doors and automatic roller shutters
- Reemplazo de piezas de repuesto para equipos antiguos: Retrofit for original equipment fitted with this MM440 model. The series is discontinued, so it is mostly used for maintenance replacement.
✅ Selection Prerequisites & Limitaciones
Fuente de alimentación: Site available power is AC220V (single-phase input can drive three-phase motors)
Motor: Rated motor power ≤0.55kW three-phase asynchronous motor
Fortalezas: Good low-speed torque with vector control, equipped with BOP panel, PID incorporado, relay/analog I/O, comunicación modbus; more capable than basic simple inverters
❌ Not suitable: Heavy shock loads, high-power machinery, main hoisting winches, continuous high-overload operating conditions
Supporting Control Schemes
Local speed setting via panel: Manual frequency adjustment through BOP
Multi-speed via terminals: DI digital terminals for preset speed levels
Analog closed-loop: AI connected to pressure/flow sensors, PID automatic constant pressure/flow regulation
comunicación PLC: Modbus RTU for PLC to read/write frequency, running status and fault codes
Siemens 6SE6440-2UC15-5AA1 (MM440 0.55kW 220V, No Built-in EMC Filter) Replacement Models Summary
Original unit features: AC200~240V single/three-phase input, control de vectores, PID, Modbus RTU, 4DI/2AI/2AO, 2 salidas de relé; interrumpido, no new original production.
Prioridad de selección: Siemens official successor models → Siemens economy models → Domestic vector inverters
- Siemens Officially Recommended Replacements (Primera elección, Closest function to MM440)
- SINÁMICA G120 (Modular, function matches MM440, for complex original control: PID, multivelocidad, Modbus)
Módulo de potencia: 6SL3210-1PB13-0UL0 (200-240V, 0.55kilovatios, no integrated filter, output current 3A consistent with original unit)
Matching Control Unit: CU240E-2 (6SL3244-0BB12-1BA1), optional BOP-2 panel (6SL3255-0AA00-4CA1)
✅ Ventajas: Sensorless vector support, PID incorporado, Modbus RTU, I/O count close to MM440; expandable communication
⚠️ Nota: Terminal definitions and parameter codes are fully incompatible; parameters cannot be copied directly. Re-commissioning required, cutout dimensions differ.
- G120C Compact Integrated Type (All-in-one, simple installation, ahorro de espacio, preferred for fans/conveyors/pumps)
Nro. de orden: 6SL3210-1KE11-8UB2 (220V 0.55kW, no filter, integrated built-in control unit, BOP interface available)
✅ All-in-one design, separate power module + CU not required. Ideal for cabinet retrofit with limited space; STO safety function integrated
⚠️ I/O count slightly less than original MM440; evaluate carefully for complex logic
- SINÁMICA V20 (Tipo económico, simple speed regulation with budget constraints)
Nro. de orden: 6SL3210-5BB11-2UV1 (220V, 0.55kilovatios, no integrated filter)
✅ Lower cost, supports V/F / basic vector, Modbus, multivelocidad; suitable for fans, pumps and simple conveyors without high-precision low-speed torque requirement
❌ Limitaciones: Vector performance weaker than MM440/G120, not for low-speed heavy-load applications, fewer I/O points
- Same-series Spare Part Option (No recomendado para nuevos proyectos., emergency maintenance only)
Stock MM440 original unit: 6SE6440-2UC15-5AA1 stock new / second-hand refurbished
Riesgos: Limited supply, high price, sin garantía, ageing risk for used units. Only for short-term equipment transition, not for new projects.
III. Domestic Replacements (Cost-down retrofit, control de vectores, 220V single-phase input driving three-phase motors)
Applicable for retrofit projects where wiring and PLC program modification are permitted, pursuing cost advantages
- Inovance MD600 / MD380 220V 0.55kW: Control de vectores, Modbus, PID, abundant I/O
- INVT GD20: General vector inverter, widely used for packaging & conveying machinery
- Delta VFD-EL / VFD-M: Low-power 220V single-phase input, basic speed regulation scenarios
📌 Selection Comparison Table
| Modelo | Número de pedido. | Voltaje | Fuerza | Vector Performance | Solicitud |
| MM440 (Original) | 6SE6440-2UC15-5AA1 | 220V | 0.55kilovatios | High-performance vector | Transmitir, mezclando, constant pressure pump, multivelocidad & PID closed-loop |
| Modular G120 | 6SL3210-1PB13-0UL0+CU240E-2 | 220V | 0.55kilovatios | High-performance vector | Primary functional replacement, preferred for legacy PID & communication projects |
| Integrated G120C | 6SL3210-1KE11-8UB2 | 220V | 0.55kilovatios | Standard vector | Gabinete compacto, fans, cintas transportadoras, STO safety required |
| Economy V20 | 6SL3210-5BB11-2UV1 | 220V | 0.55kilovatios | Basic vector | Simple speed control, fans & zapatillas, budget-sensitive |
⚠️ Critical Retrofit Notes
- Compatibilidad de la fuente de alimentación: The original unit accepts single-phase 220V input for three-phase motor drive. G120C/G120/V20 models of the same specification also support this mode.
- Dimensiones de recorte: Frame A cutout for MM440 differs from G120/V20. Cabinet cutout modification is usually required.
- Parameter Incompatibility: MM440 P-parameter system is independent from G120/V20; parameter upload/download cannot be performed directly.
- CEM: Original unit has no integrated filter. Select filterless variant for replacement. Install external EMC filter if noise immunity is needed.
- Frenado: Evaluate braking resistor sizing if the machine requires rapid stopping.
✅ Quick Selection Guidance
Original machine uses low-speed vector, PID constant pressure, comunicación modbus, multi-speed → Select G120 (modular CU240E-2)
Simple fan/conveyor application, all-in-one unit preferred for compact cabinet → G120C
Basic speed regulation only, no complex closed loop, budget priority → V20
Cost reduction project, domestic commissioning acceptable → Inovance / INVT and other domestic vector inverters
contactor,cortacircuitos,sensor,Codificador,SOCIEDAD ANÓNIMA,Convertidor




















NH42-63-318x560.png)