SIRAI L323V01G-Mini Solenoid Valve Body - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

 SIRAI L323V01G-Mini Solenoid Valve Body - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

eléctrico/

SIRAI L323V01G-Mini Solenoid Valve Body

Basic Model Definition Brand: SIRAI (now owned by ASCO Emerson, original Italian manufacturer) Modelo: L323V01G Function: 3/2 Direct-Acting Normally Closed (CAROLINA DEL NORTE) Mini Solenoid Valve Body (Coil Not Included; ZA/ZB Series Coils to Be Ordered Separately) Core Technical Specifications Fluid Structure Parameters Parameter Item Specification Circuit Configuration 3-Way 2-Position, Normalmente cerrado (CAROLINA DEL NORTE) Actuation Type Direct-acting (No ...

  • Detalles del producto

Basic Model Definition

Marca: SIRAI (now owned by ASCO Emerson, original Italian manufacturer)

Modelo: L323V01G

Función: 3/2 Direct-Acting Normally Closed (CAROLINA DEL NORTE) Mini Solenoid Valve Body (Coil Not Included; ZA/ZB Series Coils to Be Ordered Separately)

  1. Especificaciones técnicas básicas

Fluid Structure Parameters

Elemento de parámetroEspecificación
Circuit Configuration3-Way 2-Position, Normalmente cerrado (CAROLINA DEL NORTE)
Actuation Typeacción directa (No pilot; reliable actuation at low pressure)
Port ThreadG1/4 Female Thread (ISO228/1)
Diámetro del orificio1.5 milímetros
Flow Coefficient Kv0.08 m³/h
Material del cuerpo de la válvulaOT58 Brass
Standard SealNBR Nitrile Rubber (FKM Fluoroelastomer / EPDM Optional)
Max Medium Viscosity37 cSt (5°E)

Rango de presión

Max Static Pressure Rating: 40 bar

Operating Pressure Differential for AC Coils: 0 ~ 16 bar

Operating Pressure Differential for DC Coils: 0 ~ 10 bar

Rango de temperatura

Temperatura media: -10℃ ~ +90℃

Temperatura ambiente: -10°C ~ +50 °C (Max 60℃ for Class F Coils; Max 80℃ for Class H Coils)

Electrical Matching (Coil Not Included with Valve Body)

Compatible Coil Models: ZA10A, ZB10A, ZA13A, ZB14A, etc..

Standard Voltages:

C.A.: 24V/50Hz, 110V, 220/230V 50Hz

corriente continua: 12V, 24V

Protección de ingreso: IP67 when fitted with standard DIN connector; 100% ED (Continuous energization without coil burnout)

  1. 3/2-Way Operating Principle
  2. Desenergizado (Normal Closed State): Inlet Port 1 is sealed; Puerto 2 communicates with exhaust Port 3 for pressure relief.
  3. energizado (Open State): Solenoid pulls plunger; flow path 1→2 opens, exhaust Port 3 is closed.

Aplicaciones: Pneumatic direction switching, vacuum gripping, small air circuit shutoff, water spray control.

  1. Compatible Media & Industrial Applications
  2. Medios aplicables: aire comprimido, nitrogen, clean water, diluted coolant, non-corrosive inert gas.

NBR is incompatible with oil and high-temperature steam; select FKM seal version for corrosive media.

  1. Aplicaciones típicas

Mini pneumatic directional valves for automation equipment

Water circuit control for small washers and humidifying spray systems

Small air circuit shutoff for packaging machines & maquinaria textil

Laboratory instruments & miniature vacuum circuit control

  1. Selección de modelo & Matching Guidelines
  2. Complete Order Model Format: L323V01G-ZA10A 230VAC (Valve Body + Bobina + Tensión nominal)
  3. Seal Upgrade: Custom valve bodies with FKM fluoroelastomer seals available for high-temperature / oil-water working conditions.
  4. Modelos alternativos: Same series L323V02G (Normally Open NO), L323V03G Universal Type
  5. Requisitos de montaje: Mountable at any angle. Install a 40–100 mesh filter upstream of piping to prevent plunger jamming by contaminants. Only wrap the last two rear threads of male pipe threads with PTFE tape to avoid debris entering the valve chamber.
  6. Matriz de solución de problemas comunes
Fenómeno de fallaCausa principalRemedial Action
No switching when energizedbobina quemada, mismatched voltage, pressure differential exceeds 10 bar for DCReplace matching coil; reduce pipeline pressure differential
Persistent leakage after shutdownContaminants on plunger, aged sealsDisassemble and clean plunger; replace NBR/FKM seal kit
Coil heats up rapidlyIncorrect voltage selection, long-term excessive pressure differential, damaged coil insulationVerify nameplate voltage; adopt Class H high-temperature coil
Continuous air leakage from exhaust portWorn plunger, seal scratched by particulate mediaInstall upstream filter; replace complete valve body assembly

ASCO SIRAI L323V01G Solenoid Valve Instruction Manual

Nombre completo del producto: SIRAI L323V01G 3/2 Direct-Acting Normally Closed Mini Solenoid Valve Body (Coil Not Included)

Brand Affiliation: SIRAI Italy, a fluid control brand under Emerson ASCO

Normas aplicables: CE, UL, RoHS, DIN43650 electrical connector, ISO228/1 pipe thread

Table of Contents

  1. Descripción general del producto & Interpretación del modelo
  2. Especificaciones técnicas básicas
  3. Valve Body Structure & Fluid Circuit Principle
  4. Material & Seal Selection
  5. Matching Coil Models & Especificaciones eléctricas
  6. Dimensiones generales & Métodos de montaje
  7. Piping Installation Specifications
  8. Electrical Wiring Instructions
  9. Media Compatibility & Escenarios de aplicación
  10. Maintenance Procedures
  11. Diagnóstico de fallas & Remedies
  12. Complete Order Model Rules
  13. Safety Prohibitions
  14. Descripción general del producto & Interpretación del modelo

1.1 Product Introduction

The L323V01G is a 3-Way 2-Position Normally Closed (CAROLINA DEL NORTE) direct-acting solenoid valve body. Pilot-free design enables reliable startup under low pressure. Compact size adapts to miniature pneumatic, water and vacuum control loops. Valve body and coils are supplied separately; ZA/ZB series coils must be ordered independently.

1.2 Model Breakdown – L323V01G

SegmentoDefinición
L323L323 series miniature direct-acting solenoid valve platform
VBrass valve body version (OT58 Brass)
13/2 Normalmente cerrado (CAROLINA DEL NORTE)
GRAMOG1/4 BSPP Female Thread (ISO228/1)

Suffix Comparison for Same Series:

02 = 3/2 Normalmente abierto (NO)

03 = 3/2 Universal Type

Thread Suffix F = G1/8

  1. Especificaciones técnicas básicas

2.1 Fluid Performance

Elemento de parámetroStandard Specification
Functional Type3-Way 2-Position, Normalmente cerrado (CAROLINA DEL NORTE)
Tamaño del puertoG1/4 Female Thread
Seat Orifice Diameter1.5 milímetros
Flow Coefficient Kv0.08 m³/h
Max Medium Viscosity37 cSt (5°E)
Max Static Pressure Rating40 bar
Max Operating Differential Pressure (Bobina de CA)0 ~ 16 bar
Max Operating Differential Pressure (Bobina de CC)0 ~ 10 bar

2.2 Rango de temperatura

Temperatura media: -10℃ ~ +90℃ (NBR Seal); -10℃ ~ 120℃ (FKM Fluoroelastomer Seal)

Temperatura ambiente: -10℃ ~ +50℃ for standard Class F coils; max 80℃ for Class H high-temperature coils

2.3 Protección & Certificaciones

IP67 dustproof and waterproof with standard DIN connector

CE EMC compliance, UL coil certification, RoHS lead-free environmental standard

Coils support 100% ED continuous energization without overheating burnout risk

  1. Valve Body Structure & Fluid Circuit Principle

3.1 Valve Port Number Definition (3-Way)

Puerto 1 (PAG): Media Inlet (Air/Water Supply)

Puerto 2 (A): Actuator Outlet (Cylinders, Spray Nozzles, Vacuum Suction Cups)

Puerto 3 (R): Exhaust / Drain Port

3.2 Operating States

  1. De-energized Normal State (NC Closed)

Spring resets the plunger to seal Port 1; Puerto 2 connects to Port 3 for pressure relief at the actuator end.

  1. Coil Energized Open State

Solenoid magnetic force overcomes spring tension to pull the plunger; flow path 1→2 opens for media output, and Port 3 exhaust passage is sealed.

  1. Material & Seal Selection

4.1 Base Materials

Valve Body: OT58 Brass

Plunger & Moving Armature: Acero inoxidable

Primavera: 304 Acero inoxidable

4.2 Seal Material Selection Table

Seal GradeMaterialMedios aplicablesMax Temperature
Standard Factory FitNBR Nitrile Rubberaire comprimido, clean water, diluted coolant90℃
Optional UpgradeFKM FluoroelastomerEngine oil, diesel, high-temperature water, weakly corrosive solvents120℃
Special CustomEPDM Ethylene Propylene RubberAgua caliente, ozone, weak acid water110℃
  1. Matching Coil Models & Especificaciones eléctricas

Coils are not included with valve bodies. Complete valve assembly requires matching ZA/ZB series coils; modelos estándar: ZA10A, ZB10A, ZA13A, ZB14A.

5.1 Standard Voltage List

AC Alternating Current: 24V 50Hz, 110V 50Hz, 230V 50Hz

DC Direct Current: 12En DC, 24En DC

5.2 Coil Electrical Characteristics

Clase de aislamiento: Optional Class F (155℃) / Clase H (180℃)

Conector: DIN43650 3-pin standard plug (2 power pins + earth pin)

Consumo de energía: Aprox.. 8VA for AC; Aprox.. 6W for DC

  1. Dimensiones generales & Métodos de montaje
  2. Montaje & Fijación: Two M3 through mounting holes at valve bottom; mountable at any orientation (horizontal, vertical, inverted without position restrictions).
  3. Key Overall Dimensions (milímetros):

Total valve length: 45.5, Ancho: 28, Altura: 21; Thread depth: 9.9

  1. Coil Assembly: Vertically snap coil onto positioning posts on valve top; secure via rotary latch, no tools required for assembly/disassembly.
  2. Piping Installation Specifications
  3. Install upstream filter: 40–100 mesh precision screen to prevent seal scratching by particulate contaminants.
  4. Thread Sealing: Only wrap the last two rear threads of male pipe fittings with PTFE tape; forbid debris entering valve chamber.
  5. Control de par: Tightening torque for G1/4 fittings: 8–10N·m to avoid thread slipping or brass body cracking.
  6. Media Flow Direction: Strictly follow marking 1(PAG)→2(A) on valve body; reverse pressurization prohibited.
  7. Autorización de mantenimiento: Reserve minimum 30mm clearance on coil side for disassembly.
  8. Electrical Wiring Instructions

8.1 Pre-Wiring Safety Requirements

Perform wiring with power disconnected; confirm zero circuit voltage before plug insertion/removal.

Voltage fluctuation limited within ±10% of rated voltage.

8.2 Definición de terminal (3-Pin DIN Connector)

Alfiler 1: Power Line L / DC Positive (+)

Alfiler 2: Línea Neutra N / DC Negative (-)

Alfiler 3: Protective Earth (Yellow-Green cable; reliable equipment grounding required)

8.3 AC vs DC Distinction

  1. AC Coils: Non-polarized; Pin1/Pin2 can connect live and neutral interchangeably.
  2. DC Coils: Pin1 connects positive, Pin2 connects negative. Reverse polarity will not damage coil but prevents valve switching.

8.4 Waterproof Treatment

Rubber sealing gasket built into plug; tighten lock nut fully after wiring to maintain IP67 rating. Select LED-indicator waterproof plugs for humid outdoor environments.

  1. Media Compatibility & Escenarios de aplicación

9.1 Permitted Media

Dry compressed air, nitrogen, clean water, diluted cutting fluid, vacuum negative pressure circuits

9.2 Prohibited Media

Concentrated acid & álcali, strong organic solvents, high-viscosity oil, particle-laden wastewater, vapor (custom high-temperature FKM version required for steam service)

9.3 Typical Industrial Applications

  1. Mini cylinder direction switching for automation equipment
  2. Adhesive spraying & water mist humidification control for packaging machinery
  3. Small air circuit shutoff for textile machines
  4. Laboratory instruments & miniature medical fluid circuits
  5. Vacuum gripping & water switch control for small cleaning equipment
  6. Maintenance Procedures

10.1 Routine Monthly Inspection

  1. Check coils for abnormal overheating or abnormal noise
  2. Inspect pipe threads for media leakage
  3. Verify no continuous air/water dripping from exhaust port

10.2 Periodic Disassembly & Limpieza (Cada 3000 Operating Hours)

  1. Shut off air/water supply, release residual pressure and cut power supply.
  2. Remove coil, disassemble plunger assembly at valve bottom.
  3. Rinse contaminants from plunger and valve seat with purified water and anhydrous alcohol.
  4. Inspect seals for aging or cracking; replace full seal kit if damaged.
  5. Reassemble in original sequence and perform air/water leakage test.

10.3 Spare Parts List

kit de sellado, complete plunger assembly, matching coils, DIN waterproof connectors

  1. Diagnóstico de fallas & Remedy Matrix
Fenómeno de fallaCausa principalStandard Remedial Solution
Valve fails to switch on energization1. bobina quemada; 2. Mismatched voltage; 3. Differential pressure over 10 bar for DCMedir la resistencia de la bobina, replace compatible coil; reduce pipeline differential pressure
Persistent leakage at Port 2 after power-offContaminant adhesion on plunger, scratched worn NBR sealsDisassemble and clean plunger; replace full seal set
Continuous air leakage at exhaust Port 3Damaged seat seal, sealing surface worn by particulate mediaInstall upstream filter; replace complete valve body assembly
Coil overheats rapidlyExcessive supply voltage, long-term over differential pressure, aged coil insulationMatch supply voltage to nameplate; replace Class H high-temperature coil
Threaded fitting leakageInsufficient PTFE tape wrapping, insufficient fitting torqueRewrap sealing tape and fasten to specified torque
  1. Complete Order Model Rules

Standard Full Model Format:

L323V01G-ZA10A 24VDC

Breakdown: Valve Body Model + Modelo de bobina + Tensión nominal

Ejemplos:

L323V01G-ZB10A 230VAC (Complete valve with 220V AC coil)

L323V01G-ZA13A 24VDC (Complete valve with 24V DC coil)

Seal Upgrade Marking for Orders: Append suffix -FKM, p.ej. L323V01G-FKM-ZA10A 24VDC

  1. Safety Operating Prohibitions
  2. Static pressure exceeding 40 bar strictly forbidden; overpressure will rupture brass valve body directly.
  3. DC circuit differential pressure cannot exceed 10 bar for long-term operation, otherwise full shutoff cannot be achieved.
  4. Operation without upstream filter prohibited; contaminants will permanently damage seals.
  5. Hot plug/unplug of coil connector forbidden; electric arcs may burn coil terminals.
  6. FKM seal version mandatory when medium temperature exceeds 90℃; NBR seals degrade rapidly and fail.
  7. Reverse media installation (inlet via Port2, outlet via Port1) prohibited; permanent internal leakage will occur.
  8. Do not cover coil surface with thermal insulation cotton or debris; sufficient heat dissipation space must be reserved.

Anterior:

Próximo:

Deja una respuesta