Válvula de asiento de vacío de 3/2 vías UNIVER AG-3021 - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

 Válvula de asiento de vacío de 3/2 vías UNIVER AG-3021 - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

eléctrico/

Válvula de asiento de vacío de 3/2 vías UNIVER AG-3021

Authoritative Model Code Definition AG-3021-UNIVER AG: Código de serie para válvulas de asiento de vacío estándar UNIVER, diferenciado de la IA (válvulas neumáticas), CENTÍMETRO (cilindros compactos) y otras series, especialmente diseñado para aplicaciones de vacío. 3021: Combined product specification code. 30 stands for 3/2-way valve type; 21 represents G1/2 port size plus normally open (NO) función. UNIVER: Original Italian brand ...

  • Detalles del producto
  1. Authoritative Model Code Definition

AG-3021-UNIVER

  1. AG: Código de serie para válvulas de asiento de vacío estándar UNIVER, diferenciado de la IA (válvulas neumáticas), CENTÍMETRO (cilindros compactos) y otras series, especialmente diseñado para aplicaciones de vacío.
  2. 3021: Combined product specification code. 30 stands for 3/2-way valve type; 21 represents G1/2 port size plus normally open (NO) función.
  3. UNIVER: Original Italian brand logo, engaged in pneumatic component manufacturing for 60 years and a leading supplier of vacuum technology in Europe.
  4. Parámetros técnicos básicos (Official Standard)
Categoría de parámetroEspecificación detalladaObservaciones
Parámetros básicos
Valve Type3/2-way Poppet ValveDiaphragm structure, ideal for vacuum applications
Modo de operaciónNormalmente abierto (NO), opens when power off / no control airSpring return, solenoid + auxiliary pneumatic control
Modo de controlEléctrico + compressed air auxiliary control (Type U2)Auxiliary control air pressure ≥3bar required
Operación ManualScrewdriver slot type manual emergency operationConvenient for commissioning and troubleshooting
Parámetros de rendimiento
Tamaño del puertoG1/2″ (DN15)Standard thread connection with high versatility
Rated Flow Rate20 m³/hStrong vacuum suction, suitable for medium and small vacuum sucker systems
Maximum Vacuum Degree759.5 mmHg (0.5 Torr)Aprox.. 101.2 kPa vacuum pressure, meets most industrial vacuum demands
Minimum Control Air Pressure3 barEnsure reliable valve switching
Tiempo de respuesta≤50 msFast vacuum on-off to boost production efficiency
Parámetros físicos
Valve Body MaterialZamak Zinc-Aluminum AlloyLightweight design with good corrosion resistance
Spool MaterialSteelHigh strength to guarantee sealing performance
Sealing MaterialPolyurethane (valve seat) + Vulkollan (diaphragm)Special vacuum sealing material with low leakage rate
Temperatura de funcionamiento0℃ ~ +50℃Fit industrial environments, avoid condensed water freezing
Working MediumFiltered air (50Precisión de filtración en µm)Dry compressed air with oil mist lubrication is recommended
Peso1.235 kilosFácil instalación, reduce equipment load
Clase de protecciónIP65A prueba de polvo e impermeable, adaptable to harsh industrial conditions
  1. Application Environment Guidelines

Recommended Scenarios (✅ Applicable)

  1. Automatic Production Lines: Vacuum sucker material handling systems (PCB boards, glass sheets, thin metal plates, cartons, etc.)
  2. Maquinaria de embalaje: Vacuum thermoforming machines, vacuum sealing machines, vacuum adsorption systems for labelling machines
  3. Printing Equipment: Vacuum feeding for paper and positioning adsorption for printed products
  4. Electronic Manufacturing: Vacuum handling and positioning systems for semiconductor wafers and display panels
  5. Woodworking Machinery: Vacuum fixing for plates, vacuum worktables of CNC machining centers

Unrecommended Scenarios (❌ Avoid)

  1. Strong corrosive environments (acid & alkali gas): Custom stainless steel version is suggested.
  2. High-temperature environments (over 50℃): Accelerate seal aging and weaken vacuum performance.
  3. Oil-free lubrication systems: Cause seal wear and shorten service life in long-term operation.
  4. High-dust environments without filtration: Easily lead to spool jamming; fine filter installation is required.
  5. Liquid medium or high-humidity environments: Prone to internal icing and corrosion; air dryer shall be equipped.
  6. Cross-Brand Equivalent Replacement List
Modelo OriginalMarca alternativaModelo de reemplazoNotas de compatibilidad
UNIVER AG-3021FIESTAVADMI-300-NSame 3/2-way vacuum valve, G1/2 port, control air pressure needs adjustment
SMCVV5Q11-06Normally open vacuum valve, Rc1/2 port, slight difference in mounting dimension
ÁRTICO3V310-10-NOEconomical alternative, PT1/2 port, longer response time (≤80ms)
CAMOZZI338-015-00Same type vacuum poppet valve with basically identical performance parameters
NORGRENVM10101-06Vacuum solenoid valve compatible with UNIVER control systems, coil replacement needed
  1. Complete AG Series Order Number List (Latest Official Version)
Número de pedido.Nombre completo del modeloCaracterísticas especialesEscenarios aplicables
AG-3021AG-30213/2-way, G1/2, normalmente abierto, solenoid + pneumatic controlGeneral vacuum systems, medio & small vacuum suckers
AG-3011AG-30113/2-way, G1/4, normalmente abierto, solenoid + pneumatic controlMini vacuum systems for precise operation
AG-3031AG-30313/2-way, G3/4, normalmente abierto, solenoid + pneumatic controlLarge vacuum systems with high flow demand
AG-3020AG-30203/2-way, G1/2, normalmente cerrado, solenoid + pneumatic controlSafety-prioritized systems, maintain vacuum when power off
AG-3022AG-30223/2-way, G1/2, normalmente abierto, pure pneumatic control (no solenoid)Explosion-proof areas without electric control demand
AG-3023AG-30233/2-way, G1/2, normalmente abierto, with feedback signalHigh-automation systems for status monitoring
  1. Diagnóstico de fallas comunes & Soluciones de mantenimiento (Official Recommended)
Fenómeno de fallaPosibles causasPasos para solucionar problemasSoluciones de mantenimiento
Insufficient vacuum degree1. Aged/damaged seals1. Check scratches on sealing surface1. Replace polyurethane seals
2. Worn spool2. Measure control air pressure (≥3bar required)2. Grind or replace the spool
3. Insufficient control air pressure3. Inspect vacuum pipeline leakage3. Adjust control air pressure to standard value
Valve fails to switch1. Faulty solenoid coil1. Check coil power supply (CA 220 V/CC 24 V)1. Replace coil of the same model
2. Blocked control air circuit2. Dismantle air circuit to remove impurities2. Clean air circuit and install filter
3. Unreset manual operating lever3. Confirm manual lever is in automatic position3. Reset manual operating lever
Valve cannot open after power cut1. Fatigued return spring1. Check spring elasticity1. Replace return spring
2. Stuck spool2. Dismantle spool to remove foreign matters2. Clean spool and apply special vacuum grease
3. Excessively high vacuum pressure3. Verify vacuum pressure does not exceed rated maximum3. Adjust vacuum system pressure
Air leakage from valve1. Broken diaphragm1. Check cracks on diaphragm1. Replace Vulkollan diaphragm
2. Unsealed thread connection2. Confirm thread sealed with raw material tape/sealant2. Re-seal thread joints
3. Worn valve seat3. Inspect valve seat sealing surface3. Replace or grind valve seat
Valve inactive with normal control air pressure1. Aged inelastic diaphragm1. Check diaphragm elasticity1. Replace diaphragm
2. Blocked internal passage2. Dismantle valve body to clean internal passages2. Purge internal passages with compressed air
3. Wrong coil polarity3. Confirm correct positive and negative wiring of coil3. Adjust coil wiring polarity
  1. Casos de aplicación típicos

Caso 1 Electronic Industry: PCB Board Vacuum Conveying System

Customer Profile

A large-scale PCB manufacturer with annual output of 1 million square meters multi-layer circuit boards, requiring high-speed and high-precision conveying for 0.2-3mm thick PCB boards.

Desafíos principales

  1. Thin and flexible PCB boards are easy to be damaged by traditional mechanical clamps.
  2. Production line speed reaches 60m/min, requiring fast vacuum system response.
  3. Slight dust exists in working environment, stable vacuum performance is required.
  4. Vacuum pressure needs to be maintained after power off to prevent PCB falling.

Soluciones

Equipar 12 sets of AG-3021 vacuum valves matched with UNIVER vacuum suckers on both sides of conveying lines.

Adopt AG-3020 normally closed valves as standby to keep vacuum under power failure.

Install 5μm precision filters and automatic drainers to ensure clean air source.

Efectos de la aplicación

  1. PCB damage rate dropped from 5% a 0.3%, ahorrando sobre 2 million RMB annually.
  2. Vacuum response time less than 40ms, fully meeting high-speed production demands.
  3. Trouble-free continuous operation for 180 días, maintenance frequency reduced by 70%.
  4. Stable vacuum degree above 700mmHg ensures reliable PCB adsorption.

Caso 2 Industria del embalaje: High-speed Thermoforming Packaging Machine

Customer Profile

A food packaging enterprise producing 5 million packs of snack packages daily via thermoforming packaging machines.

Desafíos principales

  1. Packaging film thickness only 0.08-0.15mm requiring even vacuum suction.
  2. Packaging speed up to 120 packs per minute needing rapid vacuum switching.
  3. High ambient temperature up to 40℃ demands good high-temperature resistance of valves.
  4. Oil-free pollution is required to meet food industry hygiene standards.

Soluciones

Adopt standard AG-3021 matched with food-grade vacuum suckers.

Apply oil-free lubrication system equipped with oil mist separators.

Install temperature sensors to monitor valve operating temperature in real time.

Efectos de la aplicación

  1. Packaging film breakage rate decreased from 3.5% a 0.8%, ahorrando sobre 1.5 million RMB material cost yearly.
  2. Valve response time below 35ms satisfies high-speed packaging production.
  3. Passed FDA food-grade certification and meets food safety standards.
  4. Valve service life extended to 2 años, 50% longer than similar products.
  5. Compliance Certificates & Shipping Information
  6. Certificaciones

CE Certificate: Compliant with EU industrial electrical safety standard EN 60947-5-2

ISO 9001 Certificate: UNIVER quality management system certification

RoHS Certificate: Lead-free eco-friendly design complying with EU environmental directives

  1. Cumplimiento del transporte aéreo

Sin baterías de litio incorporadas, supercapacitors or hazardous substances

Classified as ordinary industrial pneumatic components, no special documents required for air and sea shipment

Package conforms to ISTA 2A standard for direct international transportation

  1. Origen: Manufactured in Milan, Italia, original imported with guaranteed quality

Precise Application Scenarios of UNIVER AG-3021 Vacuum Valve

Posicionamiento del producto: Italian UNIVER 3/2-way normally open vacuum solenoid valve with G1/2 port, specially used for vacuum adsorption circuit on-off control, suitable for medium-large flow and frequent switching.

Main Applicable Scenarios

  1. Automatic Manipulator Handling

Vacuum grabbing and transferring of steel plates, aluminum plates and stainless steel plates

Loading & unloading grabbing of cartons, plastic boxes and material containers

Vacuum adsorption and shifting of workpieces on assembly lines

  1. Packaging Machinery Industry

Vacuum circuit control for thermoforming machines

Negative pressure adsorption for vacuum labellers and film laminators

Food vacuum sealing machines, horizontal packing machines

Vacuum opening and feeding of express bags and packaging bags

  1. Printing & Paper Industry

Paper feeding and conveying for high-speed printing machines

Adsorption positioning of color boxes and corrugated boards

Vacuum fixing for die-cutting machines and paper pasting machines

  1. Woodworking Machinery

Vacuum plate fixing on CNC cutting machines and engraving machines

Negative pressure pressing for wooden doors and plate veneering

Plate positioning and clamping on furniture production lines

  1. Glass & Photovoltaic Industry

Vacuum grabbing and conveying of flat glass and tempered glass

Loading and unloading of photovoltaic glass and solar panels

Adsorption transferring of lenses and acrylic sheets

  1. 3C Electronic Industry

Vacuum conveying of PCB circuit boards

Material picking by adsorption for display panels, backlight panels and plastic housings

Vacuum positioning of battery cells and battery modules

  1. Logistics Sorting Industry

Vacuum diversion for automatic express sorting

Vacuum grabbing and stacking of materials

  1. Rubber & Plastic Industry

Vacuum control for plastic sheet and film stretching forming

Negative pressure shaping and adsorption conveying of rubber products

Applicable Working Conditions

  1. On-off matching for medium and small centralized vacuum generators
  2. 24-hour frequent start-stop vacuum systems on assembly lines
  3. General automatic equipment in clean air source and normal temperature workshops
  4. Safety working conditions requiring automatic vacuum breaking when normally open and power off

Inapplicable Working Conditions

  1. Severe environments with strong corrosion, heavy oil pollution and unfiltered dense dust
  2. High-temperature baking and hot air drying equipment above 50℃
  3. Ultra-high negative pressure precision micro vacuum testing equipment
  4. Underwater and damp immersion working conditions
  5. Flammable and explosive sites without explosion-proof modification

Complete Matching Coil Voltage Specifications for UNIVER AG-3021

Core Matching Information

AG-3021 adopts Type U2 electro-pilot valve; coils are separately optional accessories compatible with various standard industrial voltages.

Tipo de voltajeStandard RatingCoil ModelClasificación de potenciaEscenarios aplicables
DC Voltage12En DCDB-050111W.Mini equipment, battery-powered systems
24En DC (Recomendado)DB-050211W.Standard industrial automation voltage, compatible with PLC systems
48En DCDB-050311W.Special industrial equipment
Voltaje CA24V yDB-050710VirginiaLow-voltage safety systems
110V yDB-050810VirginiaNorth American & Japanese standard industrial voltage
230V y (European Standard)DB-050910VirginiaEuropean & Chinese standard industrial voltage
115V yDB-051010VirginiaSpecial application occasions

Key Technical Points

  1. Voltage Fluctuation Range: ±10% of rated voltage (in line with UNIVER solenoid valve standards)
  2. Modo de cableado: Standard DIN Type A connector; optional 90° upward connector, inline connector or 300mm loose cable
  3. Duty Cycle: 100% operación continua (ED=100%), suitable for 24-hour non-stop production lines
  4. Clase de protección: Coil body IP65, dustproof and waterproof for industrial use

Sugerencias de selección

  1. Prioritize 24V DC: Most widely used in industrial automation, compatible with PLC/DCS control systems with strong anti-interference performance.
  2. Notes for AC coils: 110V/230V AC coils shall be installed indoors in accordance with EN-60204-1 to ensure ventilation and heat dissipation.
  3. Special environments: Explosion-proof coils need customized order for hazardous areas.
  4. Installation Tip: Coils are connected to valve bodies via snap-fit structure for easy replacement without special tools.

Preguntas frecuentes

  1. Is the coil supplied together with the valve?

No. AG-3021 valve body and coil are sold separately; purchase coils according to actual control voltage.

  1. Are coils of different voltages interchangeable?

Sí. Coils with different voltage ratings can be replaced freely as long as they match Type U2 electro-pilot interface.

  1. Consequences of wrong voltage supply

Subtensión: Insufficient electromagnetic force leads to failed valve switching

Sobretensión: Coil overheating burnout and electro-pilot valve damage