Yaskawa SGDV-5R4D01A Servo Drive - contactor,cortacircuitos,sensor,Codificador,SOCIEDAD ANÓNIMA,Convertidor

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

 Yaskawa SGDV-5R4D01A Servo Drive - contactor,cortacircuitos,sensor,Codificador,SOCIEDAD ANÓNIMA,Convertidor

SOCIEDAD ANÓNIMA/

Yaskawa SGDV-5R4D01A Servo Drive

400clase V, MECHATROLINK-II bus-type servo drive. Max compatible with Yaskawa Σ-V 1.5kW servo motors. Classic legacy Yaskawa servo, interrumpido; new units are no longer actively promoted. Desglose del modelo: SGDV-5R4D01A Field Definition SGDV -V series SERVOPACK servo unit 5R4 Rated continuous output current 5.4A D 3-phase 400V (380~480VAC) main power supply specification 1 Command interface: MECHATROLINK-II bus communication ...

  • Detalles del producto

400clase V, MECHATROLINK-II bus-type servo drive. Max compatible with Yaskawa Σ-V 1.5kW servomotores. Classic legacy Yaskawa servo, interrumpido; new units are no longer actively promoted.

  1. Desglose del modelo: SGDV-5R4D01A
CampoDefinición
SGDV-V series SERVOPACK servo unit
5R4Rated continuous output current 5.4A
D3-fase 400V (380~480VAC) main power supply specification
1Command interface: MECHATROLINK-II bus communication type
AEspecificación estándar, no optional modules
  1. Especificaciones eléctricas básicas

Main circuit power: 3-phase AC380~480V, +10%/-15%, 50/60Hz

Controlar la fuente de alimentación: CC 24 V

Corriente de salida continua: 5.4 Arms

Maximum instantaneous output current: 14 Arms

Compatible motor rated power: 1.5kilovatios (SGMGV / SGMSV 400V series motors)

Speed loop bandwidth: 1.6kilociclos, built-in vibration suppression, real-time adaptive tuning (Tuningless)

Regenerative resistor: Internal regenerative resistor equipped; external regenerative resistor available for heavy braking applications (terminals B1/B2. Remove B2-B3 shorting link)

Encoder feedback: Supports incremental encoder; full-closed loop optional module can be installed

Comunicación: MECHATROENLACE-II, rotary switch for station number setting

  1. Interfaz & Descripción de terminales
  2. CN1: Motor encoder cable connector
  3. CN3 / CN7: MECHATROLINK-II bus (IN/OUT, daisy-chain wiring)
  4. CN2: Safety terminal (STO Safe Torque Off)
  5. Terminales del circuito principal: R/S/T 3-phase input; U/V/W motor connection; P/N DC bus; B1/B2/B3 regenerative resistor terminals
  6. Panel frontal: 7-visualización de segmentos + POWER/COM indicators, SW1 rotary switch (station number), SW2 DIP switch
  7. Aplicaciones típicas

Machine tool feed axes, maquinaria de embalaje, maquinas textiles, handling robots, maquinas de corte, multi-axis synchronous production lines, multi-axis MECHATROLINK-II bus control systems.

  1. Opciones de reemplazo (Discontinued Model Selection)
  2. Same-series replacement (Compatible with original MECHATROLINK-II): SGDV-5R4D05A (optional variant, spare part replacement only)
  3. New-generation Σ7 series recommendation: SGD7S-120D10A (400V 1.5kW, MECHATROLINK III; different bus protocol, PLC program and cables require modification)
  4. Alternativas domésticas: Inovance IS650, HCFA X3 400V-class 1.5kW bus servo. Motor parameters and communication need re-commissioning.
  5. Instalación & Pautas de mantenimiento
  6. High voltage remains in capacitors after power-off. Espera al menos 5 minutes after power cut before opening the cover. Confirm the Charge lamp is extinguished.
  7. Vertically mount inside control cabinet; reserve ventilation space top and bottom to avoid overheating caused by dust accumulation.
  8. Motor power cable and encoder cable must be shielded with single-end grounding to reduce bus interference.
  9. Regenerative circuit: Use internal resistor for normal operation. For frequent emergency stop / high deceleration loads, connect external braking resistor and modify resistor rating in parameter Pn600.
  10. Common Alarms (SGDV Σ-V)

A.100: sobrecorriente / Heat sink overheat

A.400: Sobretensión (Excessive deceleration, insufficient regenerative resistance)

A.410: Main circuit undervoltage

A.C90: Drive overheating

A.810 / A.820: MECHATROLINK-II communication fault. Check bus wiring, station number, termination resistor.

A.020: Parameter corruption. Restore factory defaults and reconfigure motor parameters.

  1. Recommended Matching Motor

SGMGV-13D (400V, 1.5kilovatios, medium inertia, most commonly matched motor)

SGDV-5R4D01A (MECHATROLINK-II Σ-V) Factory Parameter Backup List

Matched motor: SGMGV-13D (400V 1.5kW). This checklist is used for spare part replacement, whole machine backup and fault recovery. Categories: [Basic Core Parameters] [MECHATROLINK-II Bus Parameters] [Gain & Tuning] [Regeneration / Parámetros de protección] [Codificador & Unit Settings] [Alarms & Funciones]

Backup recommendation: Read online and save project file via SigmaWin+ software. Manual panel entry is only for paper backup.

  1. Basic Setting Parameters (Pn0xx)
Parameter No.Nombre del parámetroValor predeterminado de fábricaObservaciones
Pn000Control Mode Selectionn.0010MECHATROLINK-II bus position control
Pn001Código de motorAuto detected by motorAutomatically loaded on power-up for SGMGV-13D. Must reset when replacing motor
Pn002Encoder Type Selectionn.0000Codificador incremental; n.0001=Absolute encoder
Pn003Dirección de rotaciónn.0000CCW as positive direction
Pn004Servo ON At Power-upn.0000Servo ON command from host controller
Pn008Motor Rated Speed3000Rated motor speed r/min
Pn009Motor Rated Current4.4ACorriente nominal del motor
  1. MECHATROLINK-II Bus Communication Parameters (Pn8xx / Switches)
Parameter No.Nombre del parámetroValor predeterminado de fábricaObservaciones
SW1 Rotary SwitchMECHATROLINK Station Number00~F, station address 1~16; hardware switch priority higher than parameters
Pn800MECHATROLINK Cycle Time0.5EMBus communication cycle, critical for multi-axis synchronization
Pn801Communication Watchdog Time50Communication timeout in ms. A.810 triggered upon timeout
Pn802Command Selectionn.0000MECHATROLINK position command
Pn810Termination Resistorn.0000Drive internal termination resistor OFF; set to n.0001 for last axis on bus
  1. Position Unit & Resolución del codificador (Pn2xx)
Parameter No.Nombre del parámetroValor predeterminado de fábricaObservaciones
Pn202Resolución del codificador104857617-bit encoder, 1048576 pulse/rev
Pn20EElectronic Gear Numerator1Electronic gear ratio numerator
Pn210Electronic Gear Denominator1Electronic gear ratio denominator; adjust according to mechanical setup
Pn212Positive Soft LimitNo limitMechanical soft limit, configure as required
Pn213Negative Soft LimitNo limit
  1. Regenerative Braking & Protection Limit Parameters (Pn6xx, Pn4xx)
Parameter No.Nombre del parámetroValor predeterminado de fábricaDescripción
Pn600Regenerative Resistor Capacity40W.SGDV-5R4D01A built-in regenerative resistor 40W; must modify for external resistor
Pn601Regenerative Resistor Resistance100peroInternal resistor resistance
Pn400Positive Torque Limit100%Maximum output torque
Pn401Negative Torque Limit100%
Pn408Overload Warning Threshold80%Overload pre-warning
Pn501STO Safe Torque Offn.0000STO terminals active
  1. I/O Signal Assignment (Pn3xx, CN2 Terminal)
Parameter No.Nombre del parámetroValor predeterminado de fábrica
Pn300Señal de salida 1 Assignmentn.0001ALM Alarm Output
Pn301Señal de salida 2 Assignmentn.0004S-RDY Servo Ready
Pn302Señal de salida 3 Assignmentn.0005COIN Positioning Complete
Pn310Input Signal Logicn.0000Normally Open Logic
  1. Monitor Parameters (Read-only, backup for fault comparison)

Un000: Motor Speed

Un001: Motor Current

Un002: Bus Voltage

Un003: Load Factor

Un00C: MECHATROLINK Communication Status

Un010: Alarm Code

  1. Alarm History & Function Menu Fn (Non-storable parameters, record reference)

Fn000: View Alarm History

Fn005: Write Parameters to ROM (Mandatory after parameter modification!)

Fn006: Servo JOG Operation

Fn009: Factory Initialization (Restore all parameters to factory default)

⚠️Important: After Fn009 initialization, motor code Pn001 is cleared; motor identification must be re-run!

  1. Respaldo & Restore Procedures (Papel + Software Dual Backup)

1) Respaldo

  1. Encendido, Servo apagado; connect via SigmaWin+
  2. Read all parameters and save project file (.wpj)
  3. Record table parameters; log electronic gear ratio, station number and termination resistor status
  4. Export alarm history via Fn000

2) Restaurar (Replacement of SGDV-5R4D01A drive)

  1. Encendido, run Fn009 factory reset first
  2. Write Pn001 motor code, ciclo de energía
  3. Import backed-up full parameters
  4. Set MECHATROLINK station number and termination resistor
  5. Execute Fn005 to save parameters to ROM
  6. JOG test, confirm no alarms and normal bus communication
  7. Notas
  8. SGDV-5R4D01A is MECHATROLINK-II version. Do not confuse with pulse-type SGDV. Wrong Pn000 control mode will trigger A.810 communication alarm.
  9. 400V unit: DC24V control supply, 3-phase 380~480V main circuit. Power sequence: Apply 24V control power first, then main circuit power.
  10. For drive replacement: SW1 rotary station number is hardware-prioritized. Software station number setting does not take effect.
  11. When external regenerative resistor is installed, Pn600/Pn601 must be updated. Otherwise A.400 overvoltage alarm may occur and damage regenerative circuit.

Anterior:

Próximo:

Deja una respuesta

Dejar un mensaje