400clase V, MECHATROLINK-II bus-type servo drive. Max compatible with Yaskawa Σ-V 1.5kW servomotores. Classic legacy Yaskawa servo, interrumpido; new units are no longer actively promoted.
- Desglose del modelo: SGDV-5R4D01A
| Campo | Definición |
| SGDV | -V series SERVOPACK servo unit |
| 5R4 | Rated continuous output current 5.4A |
| D | 3-fase 400V (380~480VAC) main power supply specification |
| 1 | Command interface: MECHATROLINK-II bus communication type |
| A | Especificación estándar, no optional modules |
- Especificaciones eléctricas básicas
Main circuit power: 3-phase AC380~480V, +10%/-15%, 50/60Hz
Controlar la fuente de alimentación: CC 24 V
Corriente de salida continua: 5.4 Arms
Maximum instantaneous output current: 14 Arms
Compatible motor rated power: 1.5kilovatios (SGMGV / SGMSV 400V series motors)
Speed loop bandwidth: 1.6kilociclos, built-in vibration suppression, real-time adaptive tuning (Tuningless)
Regenerative resistor: Internal regenerative resistor equipped; external regenerative resistor available for heavy braking applications (terminals B1/B2. Remove B2-B3 shorting link)
Encoder feedback: Supports incremental encoder; full-closed loop optional module can be installed
Comunicación: MECHATROENLACE-II, rotary switch for station number setting
- Interfaz & Descripción de terminales
- CN1: Motor encoder cable connector
- CN3 / CN7: MECHATROLINK-II bus (IN/OUT, daisy-chain wiring)
- CN2: Safety terminal (Desconexión de par segura STO)
- Terminales del circuito principal: R/S/T 3-phase input; U/V/W motor connection; P/N DC bus; B1/B2/B3 regenerative resistor terminals
- Panel frontal: 7-visualización de segmentos + POWER/COM indicators, SW1 rotary switch (número de estación), SW2 DIP switch
- Aplicaciones típicas
Machine tool feed axes, maquinaria de embalaje, maquinas textiles, handling robots, maquinas de corte, multi-axis synchronous production lines, multi-axis MECHATROLINK-II bus control systems.
- Opciones de reemplazo (Discontinued Model Selection)
- Reemplazo de la misma serie (Compatible with original MECHATROLINK-II): SGDV-5R4D05A (optional variant, spare part replacement only)
- New-generation Σ7 series recommendation: SGD7S-120D10A (400V 1.5kW, MECHATROLINK III; different bus protocol, PLC program and cables require modification)
- Alternativas domésticas: Inovance IS650, HCFA X3 400V-class 1.5kW bus servo. Motor parameters and communication need re-commissioning.
- Instalación & Pautas de mantenimiento
- High voltage remains in capacitors after power-off. Espera al menos 5 minutes after power cut before opening the cover. Confirm the Charge lamp is extinguished.
- Vertically mount inside control cabinet; reserve ventilation space top and bottom to avoid overheating caused by dust accumulation.
- Motor power cable and encoder cable must be shielded with single-end grounding to reduce bus interference.
- Regenerative circuit: Use internal resistor for normal operation. For frequent emergency stop / high deceleration loads, connect external braking resistor and modify resistor rating in parameter Pn600.
- Alarmas comunes (SGDV Σ-V)
A.100: sobrecorriente / Heat sink overheat
A.400: Sobretensión (Excessive deceleration, insufficient regenerative resistance)
A.410: Subtensión del circuito principal
A.C90: Drive overheating
A.810 / A.820: MECHATROLINK-II communication fault. Check bus wiring, número de estación, resistencia de terminación.
A.020: Parameter corruption. Restore factory defaults and reconfigure motor parameters.
- Recommended Matching Motor
SGMGV-13D (400V, 1.5kilovatios, inercia media, most commonly matched motor)
SGDV-5R4D01A (MECHATROLINK-II Σ-V) Factory Parameter Backup List
motor emparejado: SGMGV-13D (400V 1.5kW). This checklist is used for spare part replacement, whole machine backup and fault recovery. Categorías: [Basic Core Parameters] [MECHATROLINK-II Bus Parameters] [Gain & Sintonización] [Regeneration / Parámetros de protección] [Codificador & Unit Settings] [Alarmas & Funciones]
Backup recommendation: Read online and save project file via SigmaWin+ software. Manual panel entry is only for paper backup.
- Parámetros de configuración básicos (Pn0xx)
| Número de parámetro. | Nombre del parámetro | Valor predeterminado de fábrica | Observaciones |
| Pn000 | Control Mode Selection | n.0010 | MECHATROLINK-II bus position control |
| Pn001 | Código de motor | Auto detected by motor | Automatically loaded on power-up for SGMGV-13D. Must reset when replacing motor |
| Pn002 | Encoder Type Selection | n.0000 | Codificador incremental; n.0001=Absolute encoder |
| Pn003 | Dirección de rotación | n.0000 | CCW as positive direction |
| Pn004 | Servo ON At Power-up | n.0000 | Servo ON command from host controller |
| Pn008 | Motor Rated Speed | 3000 | Rated motor speed r/min |
| Pn009 | Corriente nominal del motor | 4.4A | Corriente nominal del motor |
- MECHATROLINK-II Bus Communication Parameters (Pn8xx / interruptores)
| Número de parámetro. | Nombre del parámetro | Valor predeterminado de fábrica | Observaciones |
| SW1 Rotary Switch | MECHATROLINK Station Number | 0 | 0~F, station address 1~16; hardware switch priority higher than parameters |
| Pn800 | MECHATROLINK Cycle Time | 0.5EM | Bus communication cycle, critical for multi-axis synchronization |
| Pn801 | Communication Watchdog Time | 50 | Communication timeout in ms. A.810 triggered upon timeout |
| Pn802 | Command Selection | n.0000 | MECHATROLINK position command |
| Pn810 | Resistencia de terminación | n.0000 | Drive internal termination resistor OFF; set to n.0001 for last axis on bus |
- Position Unit & Resolución del codificador (Pn2xx)
| Número de parámetro. | Nombre del parámetro | Valor predeterminado de fábrica | Observaciones |
| Pn202 | Resolución del codificador | 1048576 | 17-bit encoder, 1048576 pulse/rev |
| Pn20E | Electronic Gear Numerator | 1 | Electronic gear ratio numerator |
| Pn210 | Electronic Gear Denominator | 1 | Electronic gear ratio denominator; adjust according to mechanical setup |
| Pn212 | Positive Soft Limit | No limit | Mechanical soft limit, configure as required |
| Pn213 | Negative Soft Limit | No limit |
- Regenerative Braking & Protection Limit Parameters (Pn6xx, Pn4xx)
| Número de parámetro. | Nombre del parámetro | Valor predeterminado de fábrica | Descripción |
| pn600 | Capacidad de resistencia regenerativa | 40W. | SGDV-5R4D01A resistencia regenerativa incorporada 40W; debe modificarse para resistencia externa |
| pn601 | Resistencia de resistencia regenerativa | 100pero | Resistencia de resistencia interna |
| pn400 | Límite de par positivo | 100% | Par de salida máximo |
| PN401 | Límite de par negativo | 100% | |
| PN408 | Umbral de advertencia de sobrecarga | 80% | Preaviso de sobrecarga |
| pn501 | Desconexión de par segura STO | n.0000 | Terminales STO activos |
- Asignación de señales de E/S (Pn3xx, Terminal CN2)
| Número de parámetro. | Nombre del parámetro | Valor predeterminado de fábrica | |
| pn300 | Señal de salida 1 Asignación | n.0001 | Salida de alarma ALM |
| pn301 | Señal de salida 2 Asignación | n.0004 | Servo listo para S-RDY |
| pn302 | Señal de salida 3 Asignación | n.0005 | Posicionamiento de MONEDAS completado |
| pn310 | Lógica de señal de entrada | n.0000 | Lógica normalmente abierta |
- Monitorear parámetros (Sólo lectura, respaldo para comparación de fallas)
Y000: Velocidad del motor
Y001: Corriente del motor
Un002: Voltaje del autobús
Un003: Factor de carga
Un00C: Estado de comunicación de MECHATROLINK
Y010: Código de alarma
- Historial de alarmas & Menú de funciones Fn (Parámetros no almacenables, referencia de registro)
fn000: Ver historial de alarmas
Fn005: Escribir parámetros en ROM (Obligatorio después de la modificación de parámetros!)
Fn006: Operación JOG del servo
Fn009: Inicialización de fábrica (Restore all parameters to factory default)
⚠️Importante: After Fn009 initialization, motor code Pn001 is cleared; motor identification must be re-run!
- Respaldo & Restore Procedures (Papel + Software Dual Backup)
1) Respaldo
- Encendido, Servo apagado; connect via SigmaWin+
- Read all parameters and save project file (.wpj)
- Record table parameters; log electronic gear ratio, station number and termination resistor status
- Export alarm history via Fn000
2) Restaurar (Replacement of SGDV-5R4D01A drive)
- Encendido, run Fn009 factory reset first
- Write Pn001 motor code, ciclo de energía
- Import backed-up full parameters
- Set MECHATROLINK station number and termination resistor
- Execute Fn005 to save parameters to ROM
- JOG test, confirm no alarms and normal bus communication
- Notas
- SGDV-5R4D01A is MECHATROLINK-II version. Do not confuse with pulse-type SGDV. Wrong Pn000 control mode will trigger A.810 communication alarm.
- 400V unit: DC24V control supply, 3-phase 380~480V main circuit. Power sequence: Aplique primero la alimentación de control de 24 V, luego alimentación del circuito principal.
- Para reemplazo de unidad: El número de estación rotativa SW1 tiene prioridad por hardware. La configuración del número de estación de software no tiene efecto.
- Cuando se instala una resistencia regenerativa externa, Pn600/Pn601 debe actualizarse. De lo contrario, puede producirse una alarma de sobretensión A.400 y dañar el circuito regenerativo..
contactor,cortacircuitos,sensor,Codificador,SOCIEDAD ANÓNIMA,Convertidor