Servoaccionamiento Yaskawa SGDV-5R4D01A - contactor,cortacircuitos,sensor,Codificador,SOCIEDAD ANÓNIMA,Convertidor

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

 Servoaccionamiento Yaskawa SGDV-5R4D01A - contactor,cortacircuitos,sensor,Codificador,SOCIEDAD ANÓNIMA,Convertidor

SOCIEDAD ANÓNIMA/

Servoaccionamiento Yaskawa SGDV-5R4D01A

400clase V, MECHATROLINK-II bus-type servo drive. Max compatible with Yaskawa Σ-V 1.5kW servo motors. Classic legacy Yaskawa servo, interrumpido; new units are no longer actively promoted. Desglose del modelo: SGDV-5R4D01A Field Definition SGDV -V series SERVOPACK servo unit 5R4 Rated continuous output current 5.4A D 3-phase 400V (380~480VAC) main power supply specification 1 Command interface: MECHATROLINK-II bus communication ...

  • Detalles del producto

400clase V, MECHATROLINK-II bus-type servo drive. Max compatible with Yaskawa Σ-V 1.5kW servomotores. Classic legacy Yaskawa servo, interrumpido; new units are no longer actively promoted.

  1. Desglose del modelo: SGDV-5R4D01A
CampoDefinición
SGDV-V series SERVOPACK servo unit
5R4Rated continuous output current 5.4A
D3-fase 400V (380~480VAC) main power supply specification
1Command interface: MECHATROLINK-II bus communication type
AEspecificación estándar, no optional modules
  1. Especificaciones eléctricas básicas

Main circuit power: 3-phase AC380~480V, +10%/-15%, 50/60Hz

Controlar la fuente de alimentación: CC 24 V

Corriente de salida continua: 5.4 Arms

Maximum instantaneous output current: 14 Arms

Compatible motor rated power: 1.5kilovatios (SGMGV / SGMSV 400V series motors)

Speed loop bandwidth: 1.6kilociclos, built-in vibration suppression, real-time adaptive tuning (Tuningless)

Regenerative resistor: Internal regenerative resistor equipped; external regenerative resistor available for heavy braking applications (terminals B1/B2. Remove B2-B3 shorting link)

Encoder feedback: Supports incremental encoder; full-closed loop optional module can be installed

Comunicación: MECHATROENLACE-II, rotary switch for station number setting

  1. Interfaz & Descripción de terminales
  2. CN1: Motor encoder cable connector
  3. CN3 / CN7: MECHATROLINK-II bus (IN/OUT, daisy-chain wiring)
  4. CN2: Safety terminal (Desconexión de par segura STO)
  5. Terminales del circuito principal: R/S/T 3-phase input; U/V/W motor connection; P/N DC bus; B1/B2/B3 regenerative resistor terminals
  6. Panel frontal: 7-visualización de segmentos + POWER/COM indicators, SW1 rotary switch (número de estación), SW2 DIP switch
  7. Aplicaciones típicas

Machine tool feed axes, maquinaria de embalaje, maquinas textiles, handling robots, maquinas de corte, multi-axis synchronous production lines, multi-axis MECHATROLINK-II bus control systems.

  1. Opciones de reemplazo (Discontinued Model Selection)
  2. Reemplazo de la misma serie (Compatible with original MECHATROLINK-II): SGDV-5R4D05A (optional variant, spare part replacement only)
  3. New-generation Σ7 series recommendation: SGD7S-120D10A (400V 1.5kW, MECHATROLINK III; different bus protocol, PLC program and cables require modification)
  4. Alternativas domésticas: Inovance IS650, HCFA X3 400V-class 1.5kW bus servo. Motor parameters and communication need re-commissioning.
  5. Instalación & Pautas de mantenimiento
  6. High voltage remains in capacitors after power-off. Espera al menos 5 minutes after power cut before opening the cover. Confirm the Charge lamp is extinguished.
  7. Vertically mount inside control cabinet; reserve ventilation space top and bottom to avoid overheating caused by dust accumulation.
  8. Motor power cable and encoder cable must be shielded with single-end grounding to reduce bus interference.
  9. Regenerative circuit: Use internal resistor for normal operation. For frequent emergency stop / high deceleration loads, connect external braking resistor and modify resistor rating in parameter Pn600.
  10. Alarmas comunes (SGDV Σ-V)

A.100: sobrecorriente / Heat sink overheat

A.400: Sobretensión (Excessive deceleration, insufficient regenerative resistance)

A.410: Subtensión del circuito principal

A.C90: Drive overheating

A.810 / A.820: MECHATROLINK-II communication fault. Check bus wiring, número de estación, resistencia de terminación.

A.020: Parameter corruption. Restore factory defaults and reconfigure motor parameters.

  1. Recommended Matching Motor

SGMGV-13D (400V, 1.5kilovatios, inercia media, most commonly matched motor)

SGDV-5R4D01A (MECHATROLINK-II Σ-V) Factory Parameter Backup List

motor emparejado: SGMGV-13D (400V 1.5kW). This checklist is used for spare part replacement, whole machine backup and fault recovery. Categorías: [Basic Core Parameters] [MECHATROLINK-II Bus Parameters] [Gain & Sintonización] [Regeneration / Parámetros de protección] [Codificador & Unit Settings] [Alarmas & Funciones]

Backup recommendation: Read online and save project file via SigmaWin+ software. Manual panel entry is only for paper backup.

  1. Parámetros de configuración básicos (Pn0xx)
Número de parámetro.Nombre del parámetroValor predeterminado de fábricaObservaciones
Pn000Control Mode Selectionn.0010MECHATROLINK-II bus position control
Pn001Código de motorAuto detected by motorAutomatically loaded on power-up for SGMGV-13D. Must reset when replacing motor
Pn002Encoder Type Selectionn.0000Codificador incremental; n.0001=Absolute encoder
Pn003Dirección de rotaciónn.0000CCW as positive direction
Pn004Servo ON At Power-upn.0000Servo ON command from host controller
Pn008Motor Rated Speed3000Rated motor speed r/min
Pn009Corriente nominal del motor4.4ACorriente nominal del motor
  1. MECHATROLINK-II Bus Communication Parameters (Pn8xx / interruptores)
Número de parámetro.Nombre del parámetroValor predeterminado de fábricaObservaciones
SW1 Rotary SwitchMECHATROLINK Station Number00~F, station address 1~16; hardware switch priority higher than parameters
Pn800MECHATROLINK Cycle Time0.5EMBus communication cycle, critical for multi-axis synchronization
Pn801Communication Watchdog Time50Communication timeout in ms. A.810 triggered upon timeout
Pn802Command Selectionn.0000MECHATROLINK position command
Pn810Resistencia de terminaciónn.0000Drive internal termination resistor OFF; set to n.0001 for last axis on bus
  1. Position Unit & Resolución del codificador (Pn2xx)
Número de parámetro.Nombre del parámetroValor predeterminado de fábricaObservaciones
Pn202Resolución del codificador104857617-bit encoder, 1048576 pulse/rev
Pn20EElectronic Gear Numerator1Electronic gear ratio numerator
Pn210Electronic Gear Denominator1Electronic gear ratio denominator; adjust according to mechanical setup
Pn212Positive Soft LimitNo limitMechanical soft limit, configure as required
Pn213Negative Soft LimitNo limit
  1. Regenerative Braking & Protection Limit Parameters (Pn6xx, Pn4xx)
Número de parámetro.Nombre del parámetroValor predeterminado de fábricaDescripción
pn600Capacidad de resistencia regenerativa40W.SGDV-5R4D01A resistencia regenerativa incorporada 40W; debe modificarse para resistencia externa
pn601Resistencia de resistencia regenerativa100peroResistencia de resistencia interna
pn400Límite de par positivo100%Par de salida máximo
PN401Límite de par negativo100%
PN408Umbral de advertencia de sobrecarga80%Preaviso de sobrecarga
pn501Desconexión de par segura STOn.0000Terminales STO activos
  1. Asignación de señales de E/S (Pn3xx, Terminal CN2)
Número de parámetro.Nombre del parámetroValor predeterminado de fábrica
pn300Señal de salida 1 Asignaciónn.0001Salida de alarma ALM
pn301Señal de salida 2 Asignaciónn.0004Servo listo para S-RDY
pn302Señal de salida 3 Asignaciónn.0005Posicionamiento de MONEDAS completado
pn310Lógica de señal de entradan.0000Lógica normalmente abierta
  1. Monitorear parámetros (Sólo lectura, respaldo para comparación de fallas)

Y000: Velocidad del motor

Y001: Corriente del motor

Un002: Voltaje del autobús

Un003: Factor de carga

Un00C: Estado de comunicación de MECHATROLINK

Y010: Código de alarma

  1. Historial de alarmas & Menú de funciones Fn (Parámetros no almacenables, referencia de registro)

fn000: Ver historial de alarmas

Fn005: Escribir parámetros en ROM (Obligatorio después de la modificación de parámetros!)

Fn006: Operación JOG del servo

Fn009: Inicialización de fábrica (Restore all parameters to factory default)

⚠️Importante: After Fn009 initialization, motor code Pn001 is cleared; motor identification must be re-run!

  1. Respaldo & Restore Procedures (Papel + Software Dual Backup)

1) Respaldo

  1. Encendido, Servo apagado; connect via SigmaWin+
  2. Read all parameters and save project file (.wpj)
  3. Record table parameters; log electronic gear ratio, station number and termination resistor status
  4. Export alarm history via Fn000

2) Restaurar (Replacement of SGDV-5R4D01A drive)

  1. Encendido, run Fn009 factory reset first
  2. Write Pn001 motor code, ciclo de energía
  3. Import backed-up full parameters
  4. Set MECHATROLINK station number and termination resistor
  5. Execute Fn005 to save parameters to ROM
  6. JOG test, confirm no alarms and normal bus communication
  7. Notas
  8. SGDV-5R4D01A is MECHATROLINK-II version. Do not confuse with pulse-type SGDV. Wrong Pn000 control mode will trigger A.810 communication alarm.
  9. 400V unit: DC24V control supply, 3-phase 380~480V main circuit. Power sequence: Aplique primero la alimentación de control de 24 V, luego alimentación del circuito principal.
  10. Para reemplazo de unidad: El número de estación rotativa SW1 tiene prioridad por hardware. La configuración del número de estación de software no tiene efecto.
  11. Cuando se instala una resistencia regenerativa externa, Pn600/Pn601 debe actualizarse. De lo contrario, puede producirse una alarma de sobretensión A.400 y dañar el circuito regenerativo..

Anterior:

Próximo:

Deja una respuesta