This product is a non-automatic load break isolator from Schneider Electric’s Interpact INS series, with the official order code 31114.

It is designed for power isolation and maintenance safety in low-voltage distribution systems.

It is 3-pole, rated current 630A, rated voltage 690VAC, without short-circuit or overload protection, and is used only for isolation purposes.

  1. Desglose del modelo
Model PartSignificadoKey Description
CompactProduct platformSchneider compact distribution platform, suitable for limited panel space
INScódigo de serieInterpact INS series, non-automatic load break isolator, isolation only, no protection
630Marco / rated currentFrame size 630A, operational current 630A (AC-22A / AC-23A)
3 PoleNumber of poles3PAG (trifásico de tres hilos), no neutral pole, not suitable for neutral isolation in TN‑S / TT systems
31114Official order codeUnique code for standard version (black rotary handle, fixed mounting)
  1. Key Technical Specifications (Official Standard)
ArtículoEspecificaciónApplicable Standard
Product typeNon-automatic load break isolatorCEI 60947-3, EN 60947-3
Tensión nominalAC 690V, Ui 750VSuitable for 380/415/480V industrial systems
Corriente nominal630A (AC-22A / AC-23A)Continuous operation ≤ 630A, recommended duty ≤ 80% (≤ 504A)
Corriente soportada de corta duración11.5kA/3s, 20kA/1s, 4kA/30sWithstands short-circuit current only, no breaking capacity
Impulse withstand voltageUimp 8kVLightning and overvoltage protection
OperationManual rotary handle (black)Motor operation available (separate order)
MontajeFixed typeFront / rear connection, 35mm DIN rail or panel mount
Protección de ingresoIP20 body, IP55 with handleIndoor panels or outdoor enclosures
Resistencia mecánica10,000 operacionesExceeds standard industrial requirements
  1. Series Model List (630A Frame)
Modelo (Order Code)polacosTipoSolicitud
INS630 3P (31114)3PAGStandard isolatorIncoming, bus-coupler, equipment isolation (3-phase 3-wire)
INS630 4P (31115)4PAGStandard isolatorIsolation with neutral (3-phase 4-wire)
INS630 3P Changeover (31154)3PAGManual changeover switchMains / generator manual switching
INS630 4P Changeover (31155)4PAGManual changeover switch3-phase 4-wire dual power switching

Extended Current Ratings

Current3P Code4P CodeBreaking Characteristics
400A3111231113Same as INS630, current only
500A3111631117
630A3111431115This model
  1. Recommended Equivalent Models from Other Brands
MarcaSerieEquivalent ModelMatching ParametersNotas
LS ElectricoMeta-MEC ISIS630N-3P3PAG, 630A, 690V, isolatorEconomic version
TEJIDOOTOT630E033PAG, 630A, 690V, isolatorVisible break
siemens3KD3KD4630-0NE103PAG, 630A, 690V, isolatorMotor operation compatible
EatonNZMNZM3-XT6303PAG, 630A, 690V, isolatorEnhanced interlocking
Changshu SwitchCM1GCM1G-630/33003PAG, 630A, 690V, isolatorDomestic high cost‑performance
  1. Aplicaciones típicas (Isolation Only, No Protection)
  2. Industrial Plants
SolicitudReasonRecommendation
Production line main isolation630A suitable for ≤315kW three-phase loadsUsed in series with NSX630N circuit breaker
Large motor circuit isolationMotors above 200kW (fans, zapatillas, compresores)Complete protection with contactor & relé
Panel bus-coupler isolationDual power supply systemsMechanical interlock recommended
  1. Commercial & Public Buildings

Office / shopping mall incomer isolation with EZD630 breakers

Secondary distribution isolation in hospitals and schools

Infrastructure partial isolation (metro, airport utilities)

  1. Special Applications

Generator outlet isolation ≤500kVA

Capacitor bank isolation ≤300kvar

Construction site temporary power isolation

  1. Selección & Operation Guidelines
  2. Selection Rules
FactorCorrect SelectionRisk of Wrong Selection
FunciónIsolation only; must be used with a circuit breakerNo protection, equipment burnout
polacos3P for IT systems; 4P for TN‑S / TTRisk of electric shock without neutral isolation
CurrentTotal load ≤ 504A (80% duty)Overheating, reduced life
CortocircuitoSystem Isc ≤ 11.5kA/3sContact welding, failure to open
  1. Safety Rules
  2. Do NOT break under load — operate only at no-load or light load
  3. Use interlocks with upstream breakers
  4. Indoor dry environment (-25°C ~ +70°C); outdoor needs IP55 enclosure
  5. Accesorios: contactos auxiliares, motor operation, padlock attachment available
  6. Key Difference from Circuit Breaker
ArtículoCompact INS630 3PCompact NSX630N 3P
TipoLoad break isolatorMolded case circuit breaker (MCCB)
FunciónIsolation onlySobrecarga + protección contra cortocircuitos
Capacidad de rupturaNinguno, withstand onlyIcu = 50kA @ 415V
UsoManual isolation for maintenanceAutomatic protection during operation
ConexiónInstalled after breakerMain protection device

Schneider Compact INS630-3P (order code 31114) is a dedicated isolation device for safe maintenance in LV distribution systems.

It must be used with a circuit breaker.

If you require both protection and isolation, use NSX630N.

For economic alternatives, consider LS IS630N or Changshu CM1G.