  1. Model Segment Definition
SegmentSignificationRemarques
QS2000ECode de série de produits3M 2nd generation (QSII) enhanced cold shrink straight joint series, suitable for 18/30kV (24kV) medium voltage systems
jeCode de spécificationSuitable for single-core cables, conductor cross-section 50–150 mm², insulation outer diameter 21.3–35.0 mm
ABBSpecial adaptation markInterface customized for ABB switchgear/transformers, ensuring perfect compatibility with ABB equipment
Implied ParameterVoltage level / Structure18/30kV (24kV) système, single-core, cold shrink type, integrated stress control design
  1. Core Specification Parameters

Paramètres électriques

ParamètreValeurDescription
Tension nominale18/30 kV (Max. 36 kV)Suitable for medium voltage power systems, conforme à la CEI 60502 standard
Maximum System Voltage24 kVMeets requirements of IEEE 48-1990 standard
Applicable Cable TypeCopper wire shielded XLPE/EPR insulated single-core power cableDedicated for polymer insulated cables; not applicable to oil-impregnated paper insulated cables
Insulation Outer Diameter Range21.3–35.0 mmFits typical insulation outer diameter of 50–150 mm² single-core cables
Power Frequency Withstand Voltage65 kV / 1 minFactory test standard to ensure insulation reliability
Partial Discharge≤10 pCStandard performance index for medium voltage joints
Switching Impulse Withstand Voltage170 kVMeets system overvoltage protection requirements
Short-Circuit Current Withstand31.5 le / 1 sCompatible with short-circuit capacity of mainstream medium voltage systems

Mécanique & Paramètres environnementaux

ParamètreValeurDescription
Insulation MaterialHigh dielectric constant silicone rubberPermanent radial compression, excellent weather resistance and aging resistance
Protection contre la pénétrationIP68Fully dustproof and waterproof, suitable for underground/tunnel/humid environments
Température de fonctionnement-40℃ ~ +90℃Wide temperature range, adapts to extreme climatic conditions
Durée de vie mécanique≥30 yearsMaintenance-free design with long service life
Méthode d'installationCold shrink type (no heating tools required)Automatically shrinks by pulling out the support core rope for easy installation
PoidsEnviron. 0.9 kg/setComplete with all components, convenient for on-site installation
CouleurNoirStandard industrial color, dirt-resistant

Applicable Cable Parameters

ParamètreDomaine d'applicationRemarques
Conductor Cross-section1×50–150 mm²Suitable for mainstream medium voltage distribution cable cross-sections
Conductor MaterialCopper / AluminiumCompatible with two mainstream conductor materials, no special model required
Insulation Thickness10–15 mmStandard insulation thickness for 18/30kV cables
Shield TypeBraided copper wire shieldMatches typical shielding structure of single-core cables
Overall Cable Outer Diameter25–40 mmTypical outer diameter range for single-core cables

3.Liste des accessoires

Nom de l'accessoireQuantitéBut
QS2000E Cold Shrink Joint Body (with integrated stress control)1 pcCore component providing insulation and stress control
Silicone Rubber Insulation Tube2 pcsCable insulation restoration and end sealing
Stress Control Mastic1 setStress control at shield cut-off position, eliminating electric field concentration
Sealing Mastic1 setSeal both ends of the joint to prevent moisture ingress
Cleaning Kit (CC-2)1 setPre-clean cable surface to remove oil stains and impurities
Copper Mesh Grounding Wire2 pcsShield layer bridging and grounding connection
Constant Force Spring2 pcsShield layer connection, no welding or copper binding wire required
Installation Instruction Manual1 copyDetailed illustrated installation guidelines
Support Core Rope Pulling Tool1 pcAssist steady rope pulling during installation to avoid joint distortion
ABB Special Adaptation Bushing1 pcEnsure perfect interface matching with ABB equipment
  1. Concurrent & Comparaison entre marques
MarqueModèleDifférence principaleScénario d'application
Original 3M Standard TypeQS2000E-IWithout ABB special bushing, universal typeConnection with non-ABB equipment, general medium voltage systems
Original 3M Large Cross-section TypeQS2000E-IISuitable for 1×95–240 mm², insulation outer diameter 28.0–45.0 mmConnection of large cross-section single-core cables
Original ABBSOT Series Straight JointPrefabricated design, prix plus élevé, seamless compatibility with ABB equipmentABB system matching, high requirement for brand consistency
SchneiderCold Shrink Straight Joint SeriesDifferent stress control design, slight difference in installation proceduresSchneider system matching, industrial automation applications
Alternative nationaleChangyuan CYLS-30/1.1Price about 1/2–2/3 of 3M, performance meets national standardsBudget-sensitive projects, non-critical circuits
Alternative nationaleWalen WRS-30/1.1Performances à coût élevé, same applicable rangeGeneral distribution projects, bulk procurement
  1. Lignes directrices de sélection & Solutions de remplacement

5.1 Paramètres de sélection clés

Voltage Level Matching: Confirm system voltage is 18/30kV; not applicable for systems below 12kV or above 36kV.

Cable Specification Confirmation:

Conductor cross-section: Well compatible within 1×50–150 mm² range.

Insulation outer diameter: Must be within 21.3–35.0 mm with tolerance ≤±1mm, ensuring sufficient radial compression of cold shrink joint.

Shield type: Only applicable to copper wire shielded single-core cables; not for copper tape shielded or non-shielded cables.

Equipment Compatibility:

Connection with ABB switchgear/transformers: Select QS2000E-I-ABB; special bushing ensures reliable connection.

Connection with other brand equipment: Select standard QS2000E-I for higher universality.

Environnement d'installation:

Underground/tunnel/humid environment: IP68 protection grade fully applicable.

Outdoor direct burial: Additional protective sleeve required for enhanced mechanical protection.

Installation Tools: No heating tools required; only basic electrician tools and cleaning supplies, single-person installation available.

5.2 Solutions de remplacement recommandées

Scénario d'applicationRecommended Replacement ModelAvantages
Direct same-spec replacement3M QS2000E-I (Modèle standard)Original authentique, entièrement compatible, slightly lower price
Large cross-section upgrade3M QS2000E-IIFits 1×95–240 mm² cables, reserved for future capacity expansion
ABB equipment dedicated3M QS2000E-I-ABBSpecial adaptive bushing, perfect matching with ABB equipment
Optimisation des coûtsChangyuan CYLS-30/1.1High-quality domestic alternative, obvious price advantage, performance meets national standards
Performance upgrade3M QS3000 Series3rd generation cold shrink technology, lower partial discharge, une plus grande fiabilité

5.3 Précautions d'installation

  1. Cable Pre-treatment

Thoroughly clean cable surface with 3M CC-2 cleaning kit to remove oil stains and oxide layer.

Keep smooth transition at shield cut-off position to avoid tip discharge; professional tools are recommended.

Use matched compression terminals for conductor connection to ensure reliable contact.

  1. Procédure d'installation

Install stress control mastic and constant force springs first, then mount the cold shrink joint body.

Pull the core rope steadily at constant speed to avoid joint distortion and ensure close fitting with cable surface.

Install ABB special adaptive bushing to ensure good sealing at equipment interface.

  1. Safety Regulations

Installers must hold valid medium voltage cable construction qualification; confirm cable power off and fully grounded before construction.

Construction site shall be dry and clean; avoid installation in rainy or humid conditions.

  1. Quality Control

Perform insulation resistance test (≥1000 MΩ) and partial discharge test (≤10 pC) after installation.

Record installation date and test data for future maintenance and traceability.

  1. Product Features Summary
  2. Enhanced Cold Shrink Technology: QS2000E series adopts 2nd generation enhanced design with integrated stress control layer for superior insulation performance.
  3. Dedicated ABB Adaptation: Equipped with special bushing to ensure perfect interface compatibility with ABB switchgear/transformers and reduce installation risks.
  4. Installation facile: Cold shrink design requires no heating tools; single-person installation saves construction time and cost.
  5. Forte adaptabilité environnementale: Operating temperature -40℃~+90℃ with IP68 rating, suitable for various harsh working conditions.
  6. Maintenance-Free Design: Silicone rubber provides permanent radial compression without regular inspection, lowering operation and maintenance costs.
  7. Safe & Fiable: Passed strict factory tests with strong short-circuit current withstand capability to ensure safe system operation.