Carlo Gavazzi VNY 4 NS/NT Conductive Level Sensor (Item No.: 481046)
| Segment de modèle | Description |
| VNY | Série de produits: Conductive level probe; VNY series features threaded connection with PBTP housing and non-insulated electrodes |
| 4 | Electrode quantity: 4 électrodes, supporting multi-level monitoring (Haut / Moyen / Faible / Ultra-low) |
| N.-É. | Type d'électrode: Non-Isolated, suitable for general conductive liquid measurement |
| NT | Connection type: Bornes à vis, convenient for field wiring |
| 481046 | Global unique item / order number, official Carlo Gavazzi part identifier |
- Full Core Technical Specifications
| Catégorie de paramètre | Caractéristiques | Remarques |
| Basic Info | Conductive level sensor for multi-point level control of conductive liquids | Must be used with amplifier relays (SV series, S195/196, ELA/ELC/ELD) |
| Numéro de commande. | 481046 (corresponds to model VNY 4 NS/NT) | Order strictly by this part number |
| Fabricant | Carlo Gavazzi | Well-known brand in industrial automation sensors |
| Electrode Configuration | 4 non-insulated electrodes, AISI316 stainless steel (DIN1.4401) | Diameter 5mm, standard length 100cm (field-cuttable) |
| Matériau du boîtier | PBTP engineering plastic | Corrosion-resistant for industrial environments |
| Type de montage | 1 1/2″ pipe thread (ISO 228/1-G1 1/2″) | Standard industrial pipeline mounting, fixed with VM15 nut |
| Méthode de connexion | Screw terminal connection (NT) | More suitable for vibrating environments than cable connection, entretien facile |
| Protection contre la pénétration | IP67 | Dust-tight and waterproof, submersible in liquid |
| Température de fonctionnement | 0°C ~ 90°C (32°F ~ 194°F) | Compatible with most industrial liquid temperature ranges |
| Température de stockage | -25°C ~ 100°C (-13°F ~ 212°F) | Adaptable to extreme transportation and storage conditions |
| Pression de service | 10 bar (@ 60°C) | Suitable for medium and high-pressure tank applications |
| Spécification du câble | No built-in cable (screw terminal type) | Customer-supplied cable recommended; shielded cable preferred to reduce interference |
| Certifications | Certifié CE (conforme à la CEI 529) | Meets EU industrial safety requirements |
| Dimensions | Electrode diameter 5mm, total length approx. 100cm | Electrode length can be cut on-site according to actual liquid level |
| Poids | Environ. 0.8kilos | Lightweight design for easy installation and maintenance |
- VNY Series Full Model List
| Item No. | Modèle | Electrode Qty | Electrode Type | Type de connexion | Matériau du boîtier | Mounting Thread | Fonctionnalités spéciales |
| 481046 | VNY 4 NS/NT | 4 | Non-Isolated (N.-É.) | Borne à vis (NT) | PBTP | 1 1/2″ | Multi-level control, general industrial use |
| 481043 | VNY 1 NS/NT | 1 | Non-Isolated (N.-É.) | Borne à vis (NT) | PBTP | 1 1/2″ | Single-point level detection, rentable |
| 481044 | VNY 2 NS/NT | 2 | Non-Isolated (N.-É.) | Borne à vis (NT) | PBTP | 1 1/2″ | Two-point high/low level control |
| 481045 | VNY 3 NS/NT | 3 | Non-Isolated (N.-É.) | Borne à vis (NT) | PBTP | 1 1/2″ | Three-point high/medium/low level control |
| 481047 | VNYI 4 IS/NT | 4 | Insulated (IS) | Borne à vis (NT) | PBTP | 1 1/2″ | PE insulated electrodes, anti-clinging liquid interference |
| 481042 | VNY 1 NS/CB | 1 | Non-Isolated (N.-É.) | Cable Connection (CB) | PBTP | 1 1/2″ | 2m fixed cable length, suitable for long-distance installation |
- Remplacement & Cross Reference
4.1 Same Brand Direct Replacement
| Modèle original | Modèle de remplacement | Replacement Description | Scénario d'application |
| VNY 4 NS/NT (481046) | VNYI 4 IS/NT | Upgraded insulated electrodes to avoid false triggering from liquid clinging | Viscous liquids and wall-adhering media (syrup, lubricating oil) |
| VNY 4 NS/NT (481046) | VNY 4 NS/CB | Changed to cable connection for heavy vibration environments | Level monitoring for vibrating equipment such as pump sets and compressors |
| VNY 4 NS/NT (481046) | VN 4 NS/CB | Cable type with PBTP housing and 1 1/2″ thread | General industrial environments, better cost performance |
4.2 Cross-Brand Equivalent Models
| Carlo Gavazzi | Schneider | Omron | Pepperl+Fuchs | Principales différences |
| VNY 4 NS/NT (481046) | XPSAK3711 | D4CC-4000 | FTL20-0020 | Carlo Gavazzi adopts superior AISI316 material with IP67 protection |
| Schneider higher integration; Omron more cost-competitive | ||||
| Field-cuttable electrode length for better adaptability | ||||
| Pepperl+Fuchs suitable for explosion-proof areas; Carlo Gavazzi for general industry |
- Application Industries & Cas typiques
Applications recommandées
- Process Industry: Tank level monitoring in chemical, petrochemical and pharmaceutical industries to prevent overflow and dry running
- Nourriture & Beverage: Raw material and finished tank level control for beer, beverage and dairy production lines
- Water Treatment: Level monitoring for sedimentation tanks and reaction tanks in waterworks and wastewater plants
- Energy Sector: Level protection for cooling and lubrication systems in power plants and substations
- Mechanical Manufacturing: Oil level monitoring for hydraulic and lubrication systems to avoid equipment damage
- Marine Industry: Level measurement for ship ballast tanks, fuel tanks and fresh water tanks
Cas d'application typiques
- Chemical Plant Acid & Alkali Tank Level Control System
Application Goal: Monitor high/low levels of three 100m³ acid and alkali tanks to prevent overflow and pump dry running
Avantages principaux: AISI316 corrosion-resistant electrodes; IP67 suitable for outdoor installation; 4-electrode enables multi-point level monitoring
System Configuration: VNY 4 NS/NT (481046) × 3 + ELA amplifier relay + PLC control system + HMI touch screen
Operation Effect: Level control accuracy ±1cm, false alarm rate reduced by 95%, maintenance cost cut by 60%
- Automobile Factory Hydraulic Station Oil Level Monitoring System
Application Goal: Monitor oil levels of 5 hydraulic stations to ensure stable operation and prevent oil shortage failure
Avantages principaux: Vibration-resistant screw terminal design; oil-resistant PBTP housing; field-cuttable electrodes adaptable to various tank heights
System Configuration: VNY 4 NS/NT (481046) × 5 + S196 amplifier + indicator light + buzzer
Operation Effect: Equipment failure rate reduced by 40%, maintenance cycle doubled
Not Recommended Applications
Non-conductive liquids: Such as pure oil, alcohol, acetone; not detectable by conductive sensors
Haute température >90°C: Adopt VPP series (up to 100°C) or high-temperature versions
Pression de travail >10 bar: Special high-pressure level sensor required
Strong corrosive media: Concentrated hydrochloric acid, concentrated sulfuric acid; use VPP series with PVDF electrodes or anti-corrosion coated models
- Installation & Wiring Guidelines
Exigences d'installation
- Mounting Position: Install on tank top or side, away from inlet ports and agitators; ensure vertical electrode immersion
- Electrode Cutting: Cut electrode length on-site according to actual liquid level; deburr the end after cutting for accuracy
- Sealing: Use suitable gaskets (PTFE recommended) for leak-tight installation to maintain IP67 protection
- Earthing Requirement: Conductive tank body can serve as common electrode; non-conductive tanks require separate common electrode grounding
- Exigence d'espacement: Keep ≥50mm between electrodes and between electrodes and tank wall to avoid signal interference
Core Terminal Definition
| Numéro de borne. | Fonction | Taper | Remarques |
| E1/E2/E3/E4 | Electrode 1–4 | Signal Input | Correspond to four level detection points; freely assign high/medium/low functions |
| COM | Common Terminal | Signal Reference | Connect to tank wall or separate common electrode to complete circuit |
| +V/-V | Alimentation | 24VCC | Requires matching amplifier relay; sensor itself needs no independent power supply |
| NO/NC/COM | Sortie relais | Switch Contact | Provided by amplifier relay for valve control or alarm output |
Points clés de la mise en service
- Electrode Setting: Define corresponding level heights for each electrode (par exemple. E1=Low, E2=Medium, E3=High, E4=Ultra-high)
- Sensitivity Adjustment: Adjust amplifier relay sensitivity to avoid false triggering caused by foam or clinging liquid
- Test de fonctionnement: Simulate level changes to verify accurate switching action and response time
- Insulation Check: For non-insulated type, ensure no short circuit between electrodes and tank wall; check insulation integrity for insulated type
- Environmental Adaptation Test: Verify long-term stability within rated temperature and pressure range
- Règles de sélection & Quick Reference
Lignes directrices de sélection
- Liquid Type: Choose VNY series for conductive liquids; use capacitive or ultrasonic sensors for non-conductive liquids
- Electrode Quantity: 1=single point, 2=high/low, 3=high/medium/low, 4=four-point full control
- Electrode Insulation: NS for normal liquids; IS insulated type for viscous wall-adhering media
- Type de connexion: NT screw terminal for vibration environments; CB cable type for long-distance installation
- Mounting Thread: 1 1/2″ for large tanks, 1″ for medium, 1/2″ for small containers
- Température & Pression: VNY for 0–90°C / 10 bar; VPP for higher temperature; special models for higher pressure
- Air Freight Compliance & Certifications
Air Freight Compliance: No lithium battery / supercapacitor. Pure mechanical and metallic structure, compliant with IATA DGR Class 9, shippable as standard general cargo.
Certifications:
– CE: Conforme à la CEI 529 ingress protection standard
– RoHS: EU RoHS compliant, free of hazardous heavy metals
– Material Certification: AISI316 stainless steel electrodes meet food-contact grade requirements for food & beverage industry
Environmental Compliance: Compliant with REACH regulations for global market access
- Achat & Logistics Information
| Purchase Item | Détails |
| MOQ | 1 unité |
| Lead Time | Standard 5–7 days; Express 2–3 days |
| Conditionnement | Individual carton with installation manual, sealing gasket and mounting nut |
| Garantie | 12 months from commissioning acceptance |
| Recommended Spares | Same model sensor, electrode extension joint (VD1), mounting nut (VM15) |
| Accessoires assortis | Carlo Gavazzi ELA/ELC/ELD amplifier relay, API, HMI touch screen |
Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires