Carlo Gavazzi WM12-96.AV5.3.3.S - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

Carlo Gavazzi WM12-96.AV5.3.3.S - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

NouvellesActualités commerciales

Carlo Gavazzi WM12-96.AV5.3.3.S

Carlo Gavazzi WM12-96.AV5.3.3.S

Segment de modèleSignificationDescription détaillée
WM12-96Base Model96×96mm panel-mounted three-phase multifunction power indicator with built-in programming keypad
AV5Range Code380/660V L-L / 5(6)Et clim; VL-N: 185V ~ 460V; VL-L: 320V ~ 800V
3Type de système1/2/3-phase system, unbalanced load, with or without neutral line
3Power Supply Type18 to 60VDC power supply, fluctuation range: -15% à +10%
SFunction OptionWith RS485 serial output (X = without this function)
  1. Core Specification Parameters

2.1 Measurement Performance

ParamètreValeurRemarques
Classe de précisionCourant/Tension: ±0.5% FSAt 25°C±5°C, RH≤60%
Pouvoir: ±(1% FS + 1 Digit)
Fréquence: ±0.1%Hz
Measurement MethodTrue RMS (TRMS)Supports distorted sine wave measurement
Sampling Rate1700 samples/s @ 60Hz
Display Refresh Rate700MS
Measured VariablesSystem & phase values: W, Wdmd, var, Virginie, VAdmd, PF, V, UN, An, Hz3×3-digit LED display, 14mm digit height
Max value indication: Amax, Wdmd max

2.2 Spécifications électriques

ParamètreValeurRemarques
Rated InputActuel: 5(6)UNCurrent input must be connected via CT; direct connection prohibited
Tension: See model definition for AV5 range
Alimentation auxiliaire18 ~ 60VDC, Consommation d'énergie: 4W
Protection contre les surchargesContinu: 1.2×FS
500ms surge: Voltage 2×Un, Current 36A
Dielectric Strength4000ACC / 1min (Between measurement input and power/RS485)Conforme à la CEI 60664

2.3 Physique & Environmental Specifications

ParamètreValeurRemarques
Panel Dimension96×96mmStandard panel mounting size
Protection contre la pénétrationDevant: IP65 (NEMA4x/12); Terminaux: IP20
Température de fonctionnement-10°C ~ +50°CRH<90%, sans condensation
Température de stockage-30°C ~ +60°CRH<90%, sans condensation
Installation CategoryCategory IIIConforme à la CEI 60664
PoidsEnviron. 400g (with packaging)

2.4 Communication Specifications (S Option)

ParamètreValeurRemarques
Type d'interfaceRS422/RS485Multi-point bidirectional communication
Communication DistanceMax.. 1200m2-wire or 4-wire connection
Plage d'adresses1 ~ 255Keypad configurable
Data Format1 start bit, 8 bits de données, pas de parité, 1 peu d'arrêt
Baud Rate9600 bit/s
  1. Standard Accessories List
  2. WM12-96.AV5.3.3.S Main Unit (with built-in programming keypad)
  3. Mounting Fasteners (Clips / Screws)
  4. Multilingual Instruction Manual
  5. Terminal Identification Labels
  6. RS485 Communication Terminal Block (if S option is selected)
  7. Product Certification Documents (CE, cULus)
  8. Concurrent & Cross-Brand Replacement Comparison
MarqueModèlePrincipales différencesScénarios d'application
Carlo GavazziWM12-96.AV5.3.3.SBuilt-in keypad, 96脳96 panel, RS485, IP65Automatisation industrielle, Building Energy Management
Schneider ÉlectriquePM2000Graphic LCD, Modbus RTU/TCP, more measurement parametersHigh-end Energy Management System
Siemens7KM2112Integrated energy metering, Profibus-DP, higher accuracyProcess Industry, Smart Grid
ABBE200Conception compacte, plusieurs protocoles de communication, rentableAutomatisation des bâtiments, OEM Equipment
Carlo GavazziWM3-9632-bit 渭P, graphic display, advanced analytical functionsPower Quality Monitoring
  1. Lignes directrices de sélection & Solutions de remplacement

Selection Mnemonic

AV5 for high voltage / AV6 for low voltage; 3 for 3-phase system / 3 for DC power; S with communication / X without

Selection Decision Tree

  1. Niveau de tension: Select AV5 for above 380V; select AV6 for below 208V
  2. Type de système: 3 = Three-phase (Recommandé); others = Single-phase / Two-phase / ARON system
  3. Alimentation: 3 = 18-60VDC; A=24VAC; B=48VAC; C=115VAC; D=230VAC
  4. Communication: S = With RS485; X = Without communication
  5. Type de montage: WM12-96 = Panel Mount; WM12-DIN = DIN Rail Mount

Solutions de remplacement recommandées

Requirement ChangeModèle recommandéRaison
Montage sur rail DINWM12-DIN.AV5.3.3.SSaves panel space, suitable for control cabinet installation
Lower Voltage SystemWM12-96.AV6.3.3.SCompatible with 120/208V systems
No Communication NeededWM12-96.AV5.3.XCost reduction with unchanged basic display functions
Higher Functional DemandWM3-9632-bit processor, graphic display, power quality analysis
  1. Scénarios d'application & Customer Value
  2. Automatisation industrielle: Real-time monitoring of electrical parameters for motors, inverters and other equipment to prevent overload and faults.
  3. Building Energy Management: Monitor three-phase power distribution systems, optimize energy consumption and reduce operational costs.
  4. OEM Equipment Integration: Embedded as standard configuration in machine tools, machines d'emballage, etc., for equipment status monitoring.
  5. Centre de données: Monitor UPS output and distribution cabinet load to ensure stable power supply.
  6. Renewable Energy: Measure output parameters of photovoltaic inverters and wind turbines for energy efficiency evaluation.

Valeur fondamentale: With high-precision TRMS measurement and multi-parameter display, it helps users quickly identify electrical abnormalities, optimize energy consumption, extend equipment service life and reduce maintenance costs.

Carlo Gavazzi WM12-96.AV5.3.3.S End-of-Life Information

Key Conclusion: This model together with the entire WM12 series was officially discontinued in April 2020. The official replacement is the WM15 series, while the WM14 series can be used as a temporary transitional replacement.

  1. Official EOL Basis

Carlo Gavazzi officially released an announcement in April 2020:

With the launch of the new WM15, the WM12, WM14, and EM26 are discontinued.

As a 96×96mm panel-mounted three-phase multifunction power indicator in the WM12 series, WM12-96.AV5.3.3.S is included in this full-series discontinuation.

  1. EOL Timeline & Replacement Arrangement
Time NodeEventRemarques
Apr-20WM15 series launched; WM12 series officially discontinuedOfficial EOL (End of Life) Date
Before DiscontinuationWM14 series as upgraded replacement for WM12WM14-96AV533S is direct drop-in replacement for WM12-96.AV5.3.3.S
After April 2020WM15 series becomes final successor to WM12/WM14Une plus grande précision (Classe 1 kWh) and added functions such as harmonic analysis
  1. Key Information of Replacement Products
  2. Direct Drop-in Replacement:

WM14-96AV533S (WM14-96×96 400/660V 5AAC 18-60VDC SERIAL)

Identical 96×96mm panel size and mounting method

Same AV5 range: 380/660V L-L / 5(6)Et clim

Same 18-60VDC power supply and RS485 communication

  1. Final Upgraded Replacement: WM15 Series

Accuracy upgraded to Class 1 for active energy

Added harmonic distortion measurement

Supports single/two/three-phase and wild-leg systems

Optional pulse output, Modbus RTU or M-Bus communication

  1. Achat & Recommandations d'entretien
  2. Stock Status: Only limited second-hand or surplus stock available; brand new original units are nearly out of stock.
  3. Maintenance Support: Carlo Gavazzi generally provides 6 years of spare parts support for discontinued models.
  4. Model Migration: New projects are recommended to adopt the WM15 series directly; existing projects can use the WM14 series for transitional upgrading.

Replacement Analysis of WM12-96.AV5.3.3.S and WM12-96.AV5.3.3.X

Conclusion fondamentale: The two models are physically and hardware compatible and can be directly interchanged for installation; however, there is a key difference in communication functions. Their interchangeability depends on whether the system requires RS485 communication.

  1. Core Difference Comparison (Only One Distinction)
ModèleDifférence cléFunctional ImpactApplication Limitation
WM12-96.AV5.3.3.SWith RS485 serial communication (S=Serial)Supports communication with host computer/PLC via Modbus RTU protocol for remote monitoring and data acquisitionSuitable for automation systems requiring centralized monitoring
WM12-96.AV5.3.3.XWithout RS485 communication (X=No Serial)Only local LED display available; remote data reading not supportedSuitable for simple applications requiring only on-site parameter viewing

All other parameters are completely identical:

Modèle de base: WM12-96 (96×96mm panel mounting, with built-in programming keypad)

Range code: AV5 (380/660V L-L / 5(6)Et clim)

System type: 3 (1/2/3-phase system, unbalanced load)

Power supply type: 3 (18-60VDC power supply)

Identical measurement accuracy, electrical specifications, physical dimensions and ingress protection rating

  1. Interchangeability Feasibility Judgment

2.1 ✅ Applicable Interchange Scenarios (Bidirectional)

System does not require RS485 communication: The X model can directly replace the S model, saving cost while fully meeting on-site display requirements.

Temporary replacement only: Either model can be used as a temporary spare part for fault maintenance without affecting basic measurement and display functions.

New project design: Selection based on actual communication demand; hardware mounting dimensions and wiring are fully compatible.

2.2 ❌ Non-interchangeable Scenarios (Unidirectional Restriction)

Modèle originalTarget ModelReason for Non-interchangeabilitySolution
S (With Communication)X (Without Communication)The system relies on RS485 remote monitoring; communication will be interrupted after replacementKeep S model, or upgrade to communication-enabled WM15 series
X (Without Communication)S (With Communication)No communication wiring or host interface in the system; the communication function cannot be usedNo need for replacement, or upgrade after completing communication infrastructure
  1. Key Points for Replacement Operation

3.1 Installation physique

Exactly the same 96×96mm panel cutout size, direct plug-and-play replacement.

Consistent terminal definition; no modification required for main circuit and power wiring.

Same ingress protection level (Front IP65, Terminal IP20) with consistent environmental adaptability.

3.2 Function Configuration

The built-in programming keypad operates identically; original parameter settings can be copied directly.

Fully compatible in measurement parameters, display modes and alarm threshold configuration.

When replacing X with S, additional configuration of RS485 address (1-255) and communication parameters (9600bps, 8N1) est requis.

3.3 Arrêt & Recommandation de remplacement

Both models were officially discontinued in April 2020 together with the entire WM12 series.

Official final replacement: WM15 Series (Classe 1 higher accuracy, with additional harmonic analysis function).

Transitional replacement: WM14-96AV533S / WM14-96AV533X (retains the same panel size and functions).

  1. Sélection & Decision Summary

Communication demand is the key; S with comm, X without. Physically interchangeable, only reliable with function matching.

Replacement Decision Tree

  1. Is RS485 communication required?

Oui: Must choose S version or upgrade to communication-capable WM15 model

Non: Both S and X are acceptable; X is more cost-effective

  1. Does the system have existing communication infrastructure?

Oui: Prioritize S version to make full use of existing resources

Non: Choose X version to avoid redundant functions

Précédent:

Suivant:

Laisser une réponse

Laisser un message