Model SegmentDescription
ACS550ABB Standard General-Purpose Inverter Series
1Wall-mounted Installation, Power Range 1.1-160kW
290UNRated Output Current (Light Duty/Fans & Pumps Application)
4Voltage Class: 380-480V Three-phase AC
132kwHeavy Duty (HD) Rated Power (246UN, 150% Overload for 1 Minute)
160kwLight Duty (LD) Rated Power (290UN, 110% Overload for 1 Minute)

  • Détails du produit

Technical File for ABB ACS550-01-290A-4 (132-160kw)

  1. Interprétation du modèle
Model SegmentDescription
ACS550ABB Standard General-Purpose Inverter Série
1Wall-mounted Installation, Power Range 1.1-160kW
290UNRated Output Current (Light Duty/Fans & Pumps Application)
4Voltage Class: 380-480V Three-phase AC
132kwHeavy Duty (HD) Rated Power (246UN, 150% Overload for 1 Minute)
160kwLight Duty (LD) Rated Power (290UN, 110% Overload for 1 Minute)
  1. Paramètres électriques de base
Élément de paramètreLight Duty (LD)/Fans & PumpsHeavy Duty (HD)/Couple constant
Rated Power160kw132kw
Rated Output Current290UN246UN
Tension d'entrée380-480V, Triphasé, 50/60HZ (卤10%)Identique à gauche
Tension de sortie0 to Input Voltage, TriphaséIdentique à gauche
Output Frequency0-500HZIdentique à gauche
Capacité de surcharge110% of Rated Current for 1 Minute150% of Rated Current for 1 Minute
Power Factor0.98 (Output)Identique à gauche
EfficacitéEnviron 97%Identique à gauche
  1. Physical & Installation Parameters

Méthode de montage: Wall-mounted (IP21 Standard Protection)

Dimensions: R6 Size, Approximately 302mm (Largeur) × 400mm (Depth) × 860mm (Height)

Poids: Approximately 80kg

Cooling Method: Forced Air Cooling

Classe de protection: IP21 (Standard), IP54 Protection Kit Optional

  1. Control Characteristics
  2. Modes de contrôle:

V/f Scalar Control

Sensorless Vector Control (SVC), Enabling High Starting Torque (150% Torque at 0.5Hz)

  1. Speed Control Accuracy: ±0.5% of Rated Synchronous Speed (Sensorless Vector Control)
  2. Frequency Resolution: 0.01Hz for Digital Setting, 0.06Hz for Analog Setting
  3. Acceleration/Deceleration Time: Adjustable from 0.1 à 1800 Seconds
  4. Built-in Functions:

Built-in EMC Filter (Class C2)

Built-in Modbus RTU Communication Interface

Patented Swinging Choke for Optimized Harmonic Suppression

Built-in PID Controller, Suitable for Closed-loop Process Control

Energy-saving Calculator, Real-time Display of Energy Savings

  1. Scénarios d'application

Light Duty Applications: Fans, Water Pumps, Cooling Towers, Ventilation Systems (160kw, 290UN)

Heavy Duty Applications: Conveyor Belts, Mixers, Compressors, Crushers (132kw, 246UN)

Applicable Industries: General Industrial Sectors such as HVAC, Water Treatment, Fabrication, Mining, Building Materials, etc..

  1. Key Function Highlights
  2. Harmonic Suppression: Built-in Swinging Choke, Compliant with IEEE 519 Standard, Reducing Grid Harmonic Interference
  3. Adaptabilité environnementale:

Température de fonctionnement: -10℃ à +40℃ (Derating Required for 40-50℃)

Humidité: 5-95% RH, No Condensation

Altitude: ≤1000m (1% Derating per 100m Above 1000m)

  1. Fonctions de protection:

Surintensité, Surcharge, Surtension, Sous-tension, Overheating Protection

Motor Overheating Protection (PTC/PID)

Short-circuit Protection, Earth Fault Protection

Phase Loss Protection, Motor Stall Protection

  1. Replacement & Upgrade Solutions
  2. Direct Replacement Models:

ABB ACS580-01-290A-4 (Next-generation Standard Inverter with Enhanced Functions)

Schneider ATV61HD160N4 (160kw, Heavy Duty)

Siemens MM440-250A (132kw, Heavy Duty) / MM440-290A (160kw, Light Duty)

  1. Upgrade Suggestion: The ACS580 Series Offers Higher Efficiency, Richer Communication Protocols, and More Comprehensive Safety Functions
  2. Installation & Points clés de l'entretien
  3. Exigences d'installation:

Vertical Mounting, Minimum 150mm Clearance on Left & Right Sides, 200mm on Top, 100mm at Bottom

Clean, Dry Environment Free of Corrosive Gases

Reliable Earthing Required (Earthing Resistance ≤4Ω)

  1. Spécifications de câblage:

Main Circuit Cables: Copper Core Cables for Both Input & Output, Cross-sectional Area ≥95mm² (Adjust According to Cable Length)

Circuit de contrôle: Shielded Cables, Routed Separately from Main Circuit (≥100mm Separation)

  1. Cycle d'entretien:

Daily: Check Operating Status, Cooling Fans, Clean Air Filters (Every 3-6 Months)

Annual: Inspect Main Circuit Terminal Tightness, Capacitor Condition, Insulation Testing

5-Year: Recommended Replacement of Cooling Fans and Electrolytic Capacitors

  1. Common Fault Codes & Troubleshooting
Fault CodeSignificationTroubleshooting Method
FA001SurintensitéCheck Motor Load, Isolation, Output Cables; Adjust Acceleration Time
FA002SurtensionCheck Grid Voltage; Adjust Deceleration Time; Install Brake Resistor
FA003Sous-tensionCheck Input Voltage; Verify Power Supply Stability
FA004OverheatingClean Heat Dissipation Channels; Inspect Fans; Reduce Ambient Temperature
FA005Motor OverloadReduce Load; Check Motor Parameter Settings; Extend Acceleration Time
  1. Ordering & Accessories

Standard Configuration: Inverter Unit, Operation Panel (ACS-CP-D), Installation Manual, Warranty Card

Accessoires en option:

Remote Operation Panel (ACS-CP-D) and Extension Cable

Brake Unit & Brake Resistor (Suitable for Frequent Start/Stop or Rapid Deceleration)

Input/Output Reactors (Enhanced Harmonic Suppression)

IP54 Protection Kit

Communication Extension Modules (Profibus DP, DeviceNet, EtherNet/IP, etc.)

Comparison & Analysis of ABB ACS550-01-290A-4 vs. ACS550-01-290A-5

  1. Core Finding: Model Validity Statement

Important Conclusion: The modelACS550-01-290A-5does not exist in the official ABB ACS550 product lineup. The standard voltage class suffixes for ABB ACS550 inverters are only three types:

2 = 208-240V Three-phase AC

4 = 380-480V Three-phase AC (The Model Mentioned by the User)

6 = 500-600V Three-phase AC

It is inferred that the user may have confused the suffix “4” (380-480V) with other series, or mistyped “6” (500-600V) as “5”. The following content will focus on comparing ACS550-01-290A-4 (380-480V) with ACS550-01-290A-6 (500-600V, the correct high-voltage version), while explaining the non-existence of the suffix “5”.

  1. Complete Model Interpretation
Model SegmentACS550-01-290A-4ACS550-01-290A-6Description
ACS550Standard General-Purpose Inverter SeriesStandard General-Purpose Inverter SeriesIdentical
1Wall-mounted Installation, Power Range 1.1-160kWWall-mounted Installation, Power Range 1.1-160kWIdentical
290UNRated Output Current (Light Duty/Fans & Pumps Application)Rated Output Current (Light Duty/Fans & Pumps Application)Identical
4月6日Voltage Class: 4=380-480V, 6=500-600VVoltage Class: 4=380-480V, 6=500-600VCore Difference
Light Duty Power160kw (290UN, 110% Overload for 1 Minute)160kw (290UN, 110% Overload for 1 Minute)Identical
Heavy Duty Power132kw (246UN, 150% Overload for 1 Minute)132kw (246UN, 150% Overload for 1 Minute)Identical
  1. Detailed Comparison Between ACS550-01-290A-4 and ACS550-01-290A-6 (Correct High-voltage Version)

3.1 Core Differences in Electrical Parameters

Élément de paramètreACS550-01-290A-4 (380-480V)ACS550-01-290A-6 (500-600V)Impact
Plage de tension d'entrée380-480V Three-phase, 50/60HZ (10%)500-600V Three-phase, 50/60HZ (卤10%)Adapts to Different Grid Systems
Output Voltage Range0 to Input Voltage, Triphasé0 to Input Voltage, TriphaséMust Match Motor Rated Voltage
Rated Power160kw (LD) / 132kw (HD)160kw (LD) / 132kw (HD)Identical (Same Current, Higher Voltage)
Courant nominal290UN (LD) / 246UN (HD)290UN (LD) / 246UN (HD)Identical
Power Factor0.98 (Output)0.98 (Output)Identical
EfficacitéEnviron 97%Environ 97%Identical
Maximum Output Frequency0-500HZ0-500HZIdentical

3.2 Physical & Application Differences

ItemACS550-01-290A-4ACS550-01-290A-6Description
DimensionsR6: 302mm*400mm*860mmR6: 302mm*400mm*860mmIdentical (Same Size for Same Current Class)
PoidsApproximately 80kgApproximately 80kgIdentical
Classe de protectionIP21 Standard, IP54 OptionalIP21 Standard, IP54 OptionalIdentical
Cooling MethodForced Air CoolingForced Air CoolingIdentical
Applicable Motors380-480V Three-phase Asynchronous Motors500-600V Three-phase Asynchronous MotorsMotor Voltage Must Match
Applications typiquesGeneral Industry, CVC, Water TreatmentHeavy Industry, Mining, Special Grid RegionsAdapts to Regional Grid Standards
EMC FilterBuilt-in Class C2 FilterBuilt-in Class C2 FilterIdentical
Communication FunctionsBuilt-in Modbus RTUBuilt-in Modbus RTUIdentical

3.3 Key Functional & Protection Differences

FonctionACS550-01-290A-4ACS550-01-290A-6Remarques
Modes de contrôleV/f Scalar Control, Sensorless Vector Control (SVC)V/f Scalar Control, Sensorless Vector Control (SVC)Identical
Starting Torque150% Rated Torque at 0.5Hz150% Rated Torque at 0.5HzIdentical
Fonctions de protectionSurintensité, Surcharge, Surtension, Sous-tension, Overheating, Short-circuit, Earth Fault, etc..Surintensité, Surcharge, Surtension, Sous-tension, Overheating, Short-circuit, Earth Fault, etc..Identical, but Protection Thresholds Adapt to Corresponding Voltage Classes
Harmonic SuppressionBuilt-in Swinging ChokeBuilt-in Swinging ChokeIdentical, Compliant with IEEE 519 Standard
  1. Recommandations de sélection
  2. Confirm Voltage Class: Select the correct suffix (2/4/6) according to on-site grid and motor rated voltage. Avoid using the non-standard suffix “5”.
  3. Correspondance de puissance: Choose 160kW for light-duty applications (les fans & pompes) and 132kW for heavy-duty applications (constant torque), corresponding to currents of 290A and 246A respectively.
  4. Replacement Options: For higher voltage or function upgrades, consider:

Correct voltage model in the same series: ACS550-01-290A-6 (500-600V)

Next-generation product: ACS580-01-290A-4 (380-480V) or ACS580-01-290A-6 (500-600V), which provide higher efficiency, richer communication protocols and more comprehensive safety functions.

  1. Résumé

The model ACS550-01-290A-5 is invalid in the ABB ACS550 series, and the official only provides three voltage suffixes: 2, 4, et 6. What the user actually needs may be:

Standard 380-480V version: ACS550-01-290A-4 (132-160kw)

High-voltage 500-600V version: ACS550-01-290A-6 (132-160kw)

The core difference between the two models lies only in the input/output voltage class, while other functional parameters (actuel, power, control mode, protection functions, etc.) are completely identical. During model selection, strict matching with on-site grid and motor parameters is required.

Modèletechnical specificationsunitquantityunit price
PLC CPUManufacturer: Siemens
Modèle: ST60
Protection degree: IP20
Voltage: 24V
6ES7288-1ST60-0AA1/0AA0
pcs1 ¥1,350.00
PLC CPUManufacturer: Siemens
Modèle: SR30
Protection degree: IP20
Voltage: 24V
pcs1 ¥750.00
Digital input/ouputManufacturer: Siemens EM DR32
Taper: Digital I/O Module
Input: 16 CC, 24V
Output: 16 relays 2A
6ES7288-2DR32-0AA0
pcs1 ¥755.00
Digital input/ouputManufacturer: Siemens
Modèle: Siemens, DE16
Input: 16 entrées numériques, 24V
Poids: 0.2kg
6ES7288-2DE16-0AA0
pcs1 ¥530.00
Analog input/Output moduleManufacturer: Siemens
Modèle: EM AM03
Input: 2 input analog channels
Output: 1 output analog channel
6ES7288-3AM03-0AA0
pcs1 ¥620.00
Communication moduleManufacturer: Siemens
Modèle: EM DP01 profibus DP slave module
Speed: 9.6 KB to 12 Mo
Interface: PROFIBUS-DP/MPI
6ES7288-7DP01-0AA0
pcs1 ¥1,142.00
Analog input/Output moduleManufacturer: Siemens
Modèle: EM AM06
Input/output: 4 entrées analogiques, 2 sorties analogiques
Poids: 0.2kg
Signal type: 0…10 V, 0…5 V, 0/4…20mA
6ES7288-3AM06-0AA0
pcs1 ¥922.00
Digital input/ouputManufacturer: Siemens, EM DT32
Input/output: 16 entrées numériques, 16 digital outputs
Poids: 0.2kg
Signal type: 0…10 V, 0…5 V, 0/4…20mA
Voltage input: 20-28V
6ES7288-2DT32-0AA0
pcs1 ¥942.00
Smart analog moduleManufacturer: Siemens,
Modèle: SM AE08 analog input module
Number of inputs: 8
Taper: 0 … 10V, 0/4-20mA
6ES7288-3AE08-0AA0
pcs1 ¥965.00
Smart analog moduleManufacturer: Siemens,
Modèle: EM AE04
Number of inputs: 4
Taper: 0/4-20mA, 0-10V
6ES7288-3AE04-0AA0
pcs1 ¥512.00
PLC CPUManufacturer: ABB,
Modèle: PM5630
Operating voltage: 24VCC
Ethernet port x 2
PM5630-2ETH
pcs1 ¥8,850.00
Digital input/outputManufacturer: ABB
Modèle: DC532
Operating voltage: 24V
16 digital transistor inputs
pcs1 ¥2,750.00
Analog input/output moduleManufacturer: ABB
Modèle: AX521 D1
Number of inputs: 4
Input type: Current, Voltage
1SAP250100R0001
pcs1 ¥4,688.00
Communication moduleManufacturer: ABB
Modèle: CM582-DP
Taper: DP Profibus Serial
Baud rate: 12000kbps
1SAP172200R0001
pcs1 ¥3,325.00
Analog inputManufacturer: Siemens,
Modèle: EM AE04
Number of inputs: 4
Taper: 0/4-20mA, 0-10V
pcs1 ¥512.00
Processor moduleManufacturer: ABB
Modèle: PM573-ETH
Voltage: 24V
Connections: Ethernet, RS232, RS485,RS422
1SAP130300R0271
pcs1 ¥7,100.00
Terminal base slot coverManufacturer: ABB
Modèle: TA524
AC500 base
1SAP180600R0001
pcs1 ¥840.00
Digital input moduleManufacturer: ABB
Modèle: DI562
Number of inputs: 16 transistor digital ,
Input type: Sink/source
Voltage: 24 CA/CC
1TNE968902R2102
pcs1 ¥2,540.00
Digital output moduleManufacturer: ABB
Modèle: DO573
Number of outputs: 16
Output type: Relais
pcs1 ¥1,981.00
Аnalog input moduleManufacturer: ABB
Modèle: AI561
Number of inputs and outputs: 4 AI, U,je
Connection type: Plug-in,
1TNE968902R1101
pcs1 ¥1,230.00
Media converterSpécification: 1GBps
Wavelength: TX1550nm, 1310nm
Distance: Not less than 30km
Connector: SC
pcs10 ¥-
PROFIBUS
Bus Connector
Manufacturer: Siemens
Modèle: 6ES7972-0BA12-0XA0
Connection: RS485 bus connection
Country of manufacture: Allemagne
pcs5 ¥210.00
RS485
Repeater
Manufacturer: Siemens
Modèle: 6ES7972-0AA02-0XA0
Connection: RS 485 repeater for PROFIBUS
Country of manufacture: Allemagne
Poids: 0.2kg