ABB PDP22-FBP Series Module - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

 ABB PDP22-FBP Series Module - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

électrique/

ABB PDP22-FBP Series Module

ABB PDP22‑FBP.100 | PROFIBUS DP Fieldbus Interface Module ABB FBP series PROFIBUS DP/V1 fieldbus interface plug-in is used to connect FBP devices such as intelligent motor controllers (UMC) to PROFIBUS DP network. It supports high-speed communication up to 12 Mbps with IP65 protection grade, adapté aux environnements industriels difficiles. Model Code Explanation Code Segment Description ...

  • Détails du produit

ABB PDP22‑FBP.100 | PROFIBUS DP Fieldbus Interface Module

ABB FBP series PROFIBUS DP/V1 fieldbus interface plug-in is used to connect FBP devices such as intelligent motor controllers (UMC) to PROFIBUS DP network. It supports high-speed communication up to 12 Mbps with IP65 protection grade, adapté aux environnements industriels difficiles.

  1. Explication du code modèle
Segment de codeDescription
PDP22Série de produits: PROFIBUS DP fieldbus plug-in, applicable to FBP devices e.g. UMC intelligent motor controller
FBPType d'interface: FieldBusPlug, fieldbus plug-in, supports PROFIBUS DP/V1 protocol
100Specification Code: Standard version, max transmission rate 12 Mbit/s, 2-channel design
  1. Main Technical Specifications
CatégorieDetailed Parameters
MarqueABB (Suisse)
TaperPROFIBUS DP/V1 Fieldbus Interface Plug-in (FieldBusPlug)
Protocole de communicationPROFIBUS DP V0/V1, conforme à la CEI 61158
Transmission Rate9.6 kbit/s ~ 12 Mbit/s (configurable via configuration software)
Interface de communicationRS-485 differential signal, A-coded M12 connector
Channel Quantity2 chaînes
AlimentationDC 24V ±10%, typical power consumption ≤0.6 W
Courant nominal1 UN
Degré de protectionIP65 (for on-site installation)
Température de fonctionnement-20℃ ~ +60℃
Max Cable Length250 mètres (varies by transmission rate)
Dimension40 mm × 20 mm × 9 mm
PoidsEnviron. 10 g
CertificationsCE, cUL, CEI 61131-2 industrial control standard
Numéro de commande1SAJ240100R1013 (Officiel), 6296317 (Supplier)
  1. Full PDP22-FBP Series Model List
ModèleCore SpecificationTransmission RateDegré de protectionPrincipales caractéristiques
PDP22-FBP.100Modèle standard, 2 chaînes9.6 kbit/s ~ 12 Mbit/sIP65Basic PROFIBUS DP interface, matches UMC intelligent motor controller
PDP22-FBP.025Economic type, 1 canal9.6 kbit/s ~ 1.5 Mbit/sIP65For low-speed application, cost-optimized design
PDP22-FBP.050High-speed type, 2 chaînes9.6 kbit/s ~ 12 Mbit/sIP65Enhanced anti-interference, suitable for complex industrial sites
PDP22-FBP.200Multi-protocol type, 2 chaînes9.6 kbit/s ~ 12 Mbit/sIP65Compatible with PROFIBUS DP & PROFIBUS FMS
PDP22-FBP.500Redundant type, 4 chaînes9.6 kbit/s ~ 12 Mbit/sIP65Dual redundant design to improve system reliability
PDQ22-FBP.100Isolated type, 2 chaînes9.6 kbit/s ~ 12 Mbit/sIP65Electrical isolation design to avoid signal interference
  1. Équivalent & Modèles de remplacement
Type de remplacementModèleMarqueDescription de la différence
Same Series ReplacementPDP22-FBP.050ABBStronger anti-interference, entièrement compatible, prix légèrement plus élevé
Same Brand UpgradePDP22-FBP.200ABBMulti-protocol support including PROFIBUS FMS, wider application
Competitor Alternative3RK1901-1CB00SiemensPROFIBUS DP interface module for Siemens motor controllers, slight mounting size difference
Competitor Alternative1786-RPARockwellPROFIBUS DP module with compatible protocol, needs configuration adjustment
Competitor AlternativeX20BM11B&R.High-speed PROFIBUS DP module for B&R automation system
  1. Champ d'application & Industry Fields

Applications recommandées

  1. Intelligent Motor Control: Connect UMC motor controllers to PROFIBUS DP network for motor status monitoring and remote control
  2. Distributed I/O System: Act as communication bridge between field devices and control layer, ideal for MCC drawer-type cabinet
  3. Process Industry: Critical equipment control in oil refineries and chemical plants; support hot-swap without offline bus nodes
  4. Manufacturing Automation: Centralized monitoring and management of production line motors, pumps and fans
  5. Automatisation des bâtiments: Control network for HVAC and lighting systems in large commercial buildings
  6. Energy Industry: Data collection and transmission for photovoltaic and wind power station equipment

Not Recommended Scenarios

  1. Non-PROFIBUS DP networks: Not directly applicable to PROFINET, EtherCAT and other industrial Ethernet systems
  2. Ultra-long distance transmission: Over 250m distance requires additional signal amplifiers
  3. Severe electromagnetic interference environment: Use PDP22-FBP.050 enhanced version without extra shielding measures
  4. Non-FBP standard devices: Extra adapter is required for connection
  5. Common Fault Diagnosis & Solutions
Phénomène de défautCauses possiblesSolutions
Communication interruption1. Bus cable failure1. Check M12 connection and cable continuity
2. Unactivated terminating resistor2. Confirm 120惟 terminating resistor setting
3. Address conflict3. Assign exclusive PROFIBUS address
4. Unstable power supply4. Ensure 24V DC power within 卤10% tolerance
Abnormal LED indicator1. Bus power off1. Check bus and module power supply
2. Mismatched communication protocol2. Set protocol to PROFIBUS DP/V1 in configuration software
3. Module hardware failure3. Replace module and contact ABB technical support
Data transmission error1. Excessively high baud rate1. Reduce transmission rate for stable communication
2. Poor cable shielding2. Optimize shielding layer connection and grounding
3. Surrounding strong interference sources3. Keep away from frequency converters and high-power equipment
Unrecognizable module1. Improper installation1. Reinstall firmly in place
2. Device incompatibility2. Confirm device complies with FBP standard
3. Outdated firmware3. Upgrade module firmware to latest version
  1. Daily Maintenance Guidelines
  2. Inspection régulière: Check M12 connector tightness and corrosion every 3 mois
  3. Cleaning Maintenance: Remove surface dust with dry compressed air, avoid chemical detergents
  4. Gestion de l'alimentation: Keep 24V DC power stable within ±10% fluctuation range
  5. Hot-swap Operation: Follow official ABB operation specifications during drawer replacement to prevent module damage
  6. Mise à niveau du micrologiciel: Update firmware regularly via official ABB website for better performance and stability
  7. Network Monitoring: Real-time monitor communication status via PROFIBUS diagnostic tools to eliminate hidden troubles in advance
  8. Air Freight Compliance & Attestation

Air Shipment Approval: No built-in lithium battery or super capacitor, classified as general industrial electronic component, available for normal air transportation

Main Certifications: CE (conforme à la CEI 61158), cUL (conforme à UL 508), CEI 61131-2

HS Code: 85371090 (Network interface equipment for industrial control)

  1. Règles de sélection & Quick Memorization

Quick Selection Rules

Suffix number definition: 100=Standard, 025=Economic, 050=High-speed enhanced, 200=Multi-protocol, 500=Redundant

Différence de série: PDQ22 = Isolated type; PDP22 = Non-isolated type

Transmission rule: Max speed 12 Mbit/s; longer distance matches lower baud rate; 250 meters is the recommended maximum distance

Précédent:

Laisser une réponse