CG4-A251-600-FS2 | Kraus & Naimer Blue Line Cam Switch 2-pole 4-position non-zero selector switch, rated 10A/440V AC/DC, central locking mounting, ideal for industrial control circuit switching Model Code Definition Code Segment Description CG4 Product Series: CG compact cam switch, Size S00 A251 Contact Configuration: 2-pole 4-position without zero position, 60° switching step, rigid silver contact ...

  • Détails du produit

CG4-A251-600-FS2 | Kraus & Naimer Blue Line Cam Switch

2-pole 4-position non-zero selector switch, rated 10A/440V AC/DC, central locking mounting, ideal for industrial control circuit switching

  1. Définition du code modèle
Segment de codeDescription
CG4Série de produits: CG compact cam switch, Size S00
A251Configuration des contacts: 2-pole 4-position without zero position, 60° switching step, rigid silver contact bridge
600Operating Angle: 3×60° (total 180°), 4 positions (1-4)
FS2Type de montage: Central locking, panel cutout 16/22mm, front protection grade IP66/IP67/IP69k
  1. Main Technical Specifications
ArticleSpécification
MarqueKraus & Naimer (Austria Blue Line)
TaperOff-load tap switch / Uniselector
Pôle & Position2 poteaux, 4 positions (no zero position)
Rated Insulation Voltage Ui440V CA/CC (CEI), 300V et (UL)
Rated Continuous Current Iu/Ith10UN (ambient 55°C, peak 60°C)
Rated Operational Current IeAC-15: 2.5UN (220-240V), 1.5UN (380-440V)
Puissance nominaleAC-3: 0.75kW (380-440V, 2P.), 2.2kW (380-440V, 3P.)
Switching Angle60° per step, total 180°
Méthode de montageCentral locking (FS2), panel hole 16/22mm
Type de borneBorne à vis, tightening torque 0.4Nm (3.5lb-in)
Cable SizeFil solide: 0.5-1.5mm²; Stranded wire: 0.75-1.5mm² (max 2.5mm² with cable lug)
Degré de protectionDevant: IP66/IP67/IP69k, Rear: IP20
CertificationsCEI 60947-3, DANS 60947-3, VDE 0660 Partie 107, UL 60947-4-1, UL 508
CouleurGrey / Noir
Numéro de commande.703584 (Conrad), 9004257056231 (EAN/GTIN)
  1. Full CG4 A2xx-600-FS2 Series List
ModèlePoteauxPositionsZero PositionPrincipales caractéristiques
CG4-A201-600-FS222OuiType de base, 2-position with zero
CG4-A220-600-FS213Non1-pole 3-position non-zero
CG4-A221-600-FS223Non2-pole 3-position non-zero
CG4-A231-600-FS214Non1-pole 4-position non-zero
CG4-A251-600-FS224Non2-pole 4-position non-zero (current model)
CG4-A250-600-FS224NonSimilar to A251, slight contact difference
CG4-A213-600-FS223Oui2-pole 3-position with zero, G251 handle
  1. Équivalent & Modèles de remplacement
Type de remplacementModèleMarqueRemarques
Same Series ReplacementCG4-A250-600-FS2Kraus & NaimerDifferent contact bridge design, fully function compatible
Same Brand UpgradeCG4-A251-600-FT2Kraus & NaimerFlange locking mounting, same performance
Competitor Alternative2002/2P4WABB2P4-position selector switch, compatible mounting dimension
Competitor Alternative3LD2102Siemens2-pole selector switch, 10Un courant nominal, IP65
  1. Champ d'application & Industry Usage

Applications recommandées

  1. Automatisation industrielle: PLC control circuit switching, equipment mode selection (Manual/Auto/Remote)
  2. Système d'alimentation: Tension & current measuring circuit switching, standby power selection
  3. Équipement mécanique: Machine tool speed shift control, conveyor direction control
  4. Building Electrical: Lighting zone control, air conditioner mode selection
  5. Marin & Offshore: Control circuit switching under harsh environment (IP69K protection)

Non-recommended Scenarios

  1. On-load switching: Not applicable for direct inductive load switching (par exemple. moteurs), use with contactors
  2. High frequent operation: Electrical service life approx. 50,000 cycles, not for high-speed frequent switching
  3. High voltage system: Max rated insulation voltage 440V, not for 690V and above systems
  4. Dépannage & Solutions
Phénomène de défautCauses possiblesSolutions
Switch cannot rotate1. Lock mechanism not released1. Unlock FS2 locking device completely
2. Internal mechanical jam2. Power off then inspect internal springs & contacts
3. Over-tight wiring3. Rewire and control torque ≤0.4Nm
Poor contact performance1. Contact oxidation1. Polish silver contacts gently with fine sandpaper
2. Contact wear2. Replace contact module or whole switch
3. Câblage lâche3. Retighten all terminals
Failed protection performance1. Aging sealing gasket1. Replace original sealing gasket
2. Improper installation2. Ensure close fitting between switch and panel
3. Oversized panel cutout3. Adjust panel hole within 16-22mm
Decreased rated current1. Excess ambient temperature1. Lower ambient temperature or enhance heat dissipation
2. Contaminated contacts2. Clean contacts and terminals
3. Undersized cables3. Use qualified cables (stranded ≥0.75mm²)
  1. Daily Maintenance Guidelines
  2. Periodic Inspection: Check locking structure and contact condition every 6 mois
  3. Cleaning: Remove dust by compressed air, avoid chemical detergent
  4. Torque Management: Strictly follow 0.4Nm tightening torque during wiring
  5. Ambient Control: Avoid long-term operation above 55°C
  6. Prévention des erreurs de fonctionnement: Keep locking mechanism functional to avoid accidental switching
  7. Air Freight Compliance & Attestation

Air Shipment Allowed: No built-in lithium battery / super capacitor, classified as general electrical component

Main Certificates: CE (conforme à la CEI 60947-3), UL 508, VDE 0660

HS Code: 85365080 (Electrical control switches & disjoncteurs)

Complete Model List of Kraus & Naimer Blue Line Cam Switches

  1. General Classification Overview

Kraus & Naimer Blue Line switches are divided into 4 categories by rated current and usage, covering full range 10A~2400A.

  1. Control Switch Series (10A~25A) | Catalog 120

2.1 CG Series Compact Control Switch (10A/20A, IP20)

Modèle de baseCourant nominalTailleCaractéristiquesModèles typiques
CG4/CG4-110UNS001μ/35μ gold-plated contact, double-break silver alloy bridgeCG4-A201-600-FS2, CG4-A251-600-FS2
CG610UNS0Standard control switch, finger-safe terminalsCG6-A201-600-FT2
CG710UNS0Special function, illuminated handle optionalCG7-A214-600-FT2
CG810UNS0Universal type, multi-mounting availableCG8-A220-600-FT4
CG910UNS0With lock mechanism, anti-misoperationCG9-A213-600-FS2
CG10/CG11/CG1210UNS0Multi-pole, maximum 4 poteauxCG12-A251-600-FS2
CG1620UNS1Higher current, heavy-duty controlCG16-A201-600-FT2

2.2 CH/CHR Series (10A~25A, Lockable Terminal)

Modèle de baseCourant nominalTailleCaractéristiquesModèles typiques
CH10/CHR1010UNS0CHR anti-loose terminal anti-vibrationCH10-A201-600-FT2
CH11/CHR1110UNS0Multi-pole, double-break designCHR11-A251-600-FS2
CH12/CHR1210UNS0Special cam for complex controlCH12-A213-600-FS2
CH16B/CHR16B16UNS1Higher current, finger protectionCH16B-A221-600E
CH20/CHR2020UNS1Heavy-duty for motor circuitsCH20-A251-600-FS2

2.3 CGD Series Mini Control Switch (5A Low Current)

Modèle de baseCourant nominalTailleCaractéristiquesModèles typiques
CGD4-15UNS00Ultra-compact, 35渭 gold-plated contactCGD4-1-A201-600-FT2
  1. Contrôle & Load Switch Series (10A~315A) | Catalog 100

3.1 CA Series Universal Control Switch (10A~25A)

Modèle de baseCourant nominalTailleCaractéristiquesModèles typiques
CA010UNS00Mini type for narrow spaceCA0-A201-600-FT2
CA210UNS0Standard double-break structureCA2-A201-600-FT2
CA410UNS0Multi-pole up to 4 poteauxCA4-A201-600-FT2
CA10/CA10B10UNS0Finger-safe anti-shock terminalCA10-A722-G001
CA20/CA20B20UNS1Heavy-duty controlCA20B-A221-600E
CA25/CA25B25UNS1Max current for motor controlCA25B-A251-600-FS2

3.2 CAD Series Self-cleaning Contact Switch (10A~16A)

Modèle de baseCourant nominalTailleCaractéristiquesModèles typiques
CAD510UNS0Mini self-clean cross contactCAD5-A201-600-FT2
CAD1110UNS0High contact stabilityCAD11-US5626-FT1
CAD1616UNS1Industrial heavy-duty applicationCAD16-A221-600E

3.3 C Series Load Switch / Isolator (10A~315A)

Modèle de baseCourant nominalTailleCaractéristiquesModèles typiques
C2626UNS1Basic load switchC26-A201-600-FT2
C3232UNS1Higher breaking capacityC32-A221-600E
C42/C4340UNS22P/3P optionalC43-A221-600E
C6363UNS2Heavy load switchC63-A251-600-FS2
C80/C80-680UNS36-pole optionalC80-6-A221-600E
C125/C125-6125UNS3Medium high currentC125-A251-600-FS2
C200-4200UNS44-pole for 3-phase 4-wireC200-4-A221-600E
C315/C316315UNS4Main power isolation switchC316-A251-600-FS2

3.4 CL Series Economic Load Switch (10A~20A)

Modèle de baseCourant nominalTailleCaractéristiquesModèles typiques
CL1010UNS0Cost-effective basic controlCL10-A201-600-FT2
CL2020UNS1Economic heavy-duty controlCL20-A221-600E
  1. High Current Isolator Series (350A~2400A) | Catalog 100

4.1 L Series High Current Isolator

Modèle de baseCourant nominalTailleCaractéristiquesModèles typiques
L350350UNS5Standard high current isolatorL350-A221-600E
L500500UNS5Medium large currentL500-A251-600-FS2
L630630UNS6Industrial main power supplyL630-A201-600-FT2
L800800UNS6Strong breaking performanceL800-A251-600-FS2
L1000/L11001000A/1100AS7Large industrial equipmentL1100-A221-600E
L14501450UNS7Ultra-large currentL1450-A251-600-FS2
L19001900UNS8Factory main power switchL1900-A221-600E
L24002400UNS8Max current for heavy industryL2400-A251-600-FS2
  1. Load Break Switch Series (16A~1250A) | Catalog 100

5.1 KF/KH/KG Series Load Break Switch

Modèle de baseCourant nominalTailleCaractéristiquesModèles typiques
KF16/KF2016A/20AS0/S1Basic load break switchKF20-T203/SGZ006E
KH32/KH4132A/41AS1/S2Pouvoir de coupure amélioréKH32-T203/SGZ006E
KG64/KG8064A/80AS2/S3Heavy load breakingKG80-T203/SGZ006E
KG100/KG125100A/125AS3/S4Medium high current breakingKG125-T203/SGZ006E
KG200/KG250200A/250AS4/S5Large equipment power controlKG250-T203/SGZ006E
KG400/KG630400A/630AS5/S6Factory branch power distributionKG630-T203/SGZ006E
KG800/KG1250800A/1250AS6/S7Large factory main circuit controlKG1250-T203/SGZ006E
  1. Règle de dénomination du modèle
Code SectionDéfinitionExemple
Code de sérieCG=Compact Control, CA=General Control, CAD=Self-cleaning Contact, CH=Lock Terminal, C=Load Switch, L=High Current IsolatorCG4, CA10, C63, L630
Contact CodeA=No zero position, B=With zero position; 2nd digit=pole number, last two digits=position numberA251=2P4P non-zero
Operating Angle600=3×60° total 180°, 620=Mixed angle600=4 positions
Mounting CodeFS2=Central locking, FT2=Flange locking, FS1=Front lockingFS2=Central lock mount
Handle CodeE=Standard handle, EAO=EAO compatible handle, G521=Rotary handleE=Standard handle