AIRTAC 6SV210-08 5/2-Way Single-Solenoid Solenoid Valve

Complete ordering example: 6SV210-08B (B=DC24V, plug-in coil, PT thread) Model Code Decoding Field Description 6SV Series: New‑generation internal‑pilot‑exhaust solenoid valve, compatible with manifold sub‑base for valve island assembly 2 200 valve body size 10 5/2-chemin, single‑solenoid (retour à ressort); energize for shifting, de‑energize for automatic spring reset ‑08 Port size PT1/4 (2‑thread); P/A/B ports PT1/4, R/S exhaust ...

  • Détails du produit

Complete ordering example: 6SV210-08B (B=DC24V, plug-in coil, PT thread)

  1. Décodage du code modèle
ChampDescription
6SVSérie: New‑generation internal‑pilot‑exhaust électrovanne, compatible with manifold sub‑base for valve island assembly
2200 valve body size
105/2-chemin, single‑solenoid (retour à ressort); energize for shifting, de‑energize for automatic spring reset
‑08Port size PT1/4 (2‑thread); P/A/B ports PT1/4, R/S exhaust ports PT1/8

Suffix voltage code: A=AC220V; B=DC24V; C=AC110V; E=AC24V; F=DC12V

Electrical connection: Blank=plug-in; I=cable-out; D=DIN socket; M=M8 M12 connector; Fil: Blank=PT, G=G thread, T=NPT

  1. Électricité de base & Pneumatic Specifications
ArticleParamètre
Type de vanne5/2-chemin, internal pilot operated, retour à ressort, internal pilot exhaust (pilot air does not leak from coil side for dust resistance)
Pression de service0.15‑0.8 MPa; Proof pressure 1.2 MPa
Ambiant & medium temperature‑5 ~ +50℃, clean dry compressed air, oil‑free compatible
Flow capacity≈1080 L/min; Effective orifice Cv≈1.15, higher than legacy 4V210‑08 (850 L/min)
Consommation électrique de la bobineDC24V low‑power approx. 1.2W (legacy 4V: 2.8W)
Max switching frequency5 cycles/sec
Matériau du corpsExtruded aluminum alloy, NBR seals; Lubrication‑free
PortsP.(inlet)/A/B(working): PT1/4; R/S exhaust: PT1/8
MontageDirect body‑mount via screws; compatible with 6SV200M manifold sub‑base for valve island

III. 6SV210-08 VS 4V210-08 Comparison

Article6SV210‑08 (Nouvelle génération)4V210‑08 (Legacy Classic)
Pilot exhaustInternal exhaust, pilot air discharged through main R/S ports; no vent hole on coil housing, superior dust resistanceExternal exhaust; pilot air vents via small holes on coil housing, prone to dust ingress
Consommation d'énergie1.2W @ DC24V2.8W @ DC24V
Débit1080 L/min850 L/min
Electrical optionsPlug-in / Cable‑out / DEPUIS / M8 (4 types)Plug-in, DEPUIS (2 types)
Valve island footprintValve island assembly approx. 32% plus petitLarger overall dimension
InterchangeabilitéMounting hole pattern NOT compatible with 4V210‑08; cannot fit 4V‑series manifold; dedicated 6SV200M sub‑base requiredFor 4V‑200 series manifold bases

⚠️Selection pitfall: Not a direct drop-in replacement for 4V210-08. For valve-island retrofitting, use only 6SV200M manifold. Tube fittings remain interchangeable for standalone body-ported installation.

  1. Port Identification & Commande manuelle

P.: Compressed air supply; A/B: Cylinder ports; R., S: Exhaust ports. Mufflers or exhaust throttles must be fitted.

Side-mounted manual override: Non-locking momentary push-button. Press to shift, release for reset. Used for pre-wiring manual cylinder test; do NOT hold continuously.

  1. Règles d'installation & Hard Restrictions (Red Lines)
  2. Do not drop, strike or impact the pilot coil head. Pilot assembly is precision-built; impact causes spool sticking and internal leakage.
  3. Coil fastening screw M2.5 torque: 0.4-0.45 N·m. Avoid over-torque to prevent thread stripping.
  4. Compressed-air filtration is mandatory. Heavy moisture/oil contamination drastically shortens seal service life. Use only dry compressed air as working medium.
  5. Single-solenoid type: Spring-reset on de-energization. Avoid continuous coil energization, which accelerates coil aging.
  6. Avoid heavy EMI and heavy-dust environments. Even with internal pilot exhaust, mufflers are still recommended on exhaust ports.
  7. Dépannage typique
SymptômeCause premièreRemède
No shifting upon energizationMismatched coil voltage; burnt‑out coil; clogged pilot orifice; supply pressure below 0.15 MPaVerify coil voltage; measure coil resistance; check air supply; clear pilot passage
Fail to reset after de‑energizationSpring jam; debris‑stuck spool; overpressureDisassemble & clean spool; verify operating pressure; improve air filtration
Persistent leakage at A/B portsWorn spool seals; particulate contamination trapped inside valve cavityClean or replace valve assembly
Excessive coil heatingOver‑voltage; continuous long‑duration energization; wrong coil specificationDuty‑cycle control; verify supply voltage

VII. Scénarios d'application typiques

Automation assembly lines, machines d'emballage, auxiliary pneumatic circuits for injection-molding machines, machine-tool pneumatic clamps, conveyor-line cylinder control. Ideal for valve-island cluster applications requiring low power consumption, high dust resistance and enhanced flow performance.

AIRTAC 6SV210-08 Bill-of-Material Breakdown

ComposantMaterial Specification
Valve bodyExtruded 6061‑series aluminum alloy, hard anodized finish, high mechanical strength & résistance à la corrosion
Spool / SleeveHardened aluminum alloy, precision‑honed bore for low friction
Scellés (Joints toriques, spool seals)NBR nitrile butadiene rubber, optimized for compressed‑air service; operating range ‑5~+50℃, lubrication‑free
Return springStainless spring steel
Pilot housingFlame‑retardant PA engineering plastic
Coil windingEnameled copper wire; coil housing: black flame‑retardant plastic with epoxy potting sealing
Thread portsIntegral machined aluminum PT1/4 threads on valve body
FastenersM2.5 pilot mounting screw: zinc‑plated carbon steel

Notes complémentaires

  1. Medium limitation: Designed exclusively for dry compressed air. Not suitable for water, steam or highly corrosive gas. NBR is incompatible with ketones and ester-based organic solvents.
  2. Matching 6SV200M manifold sub-base: Extruded aluminum alloy + NBR gasket.
  3. Comparison vs legacy 4V210-08: Both use aluminum valve bodies. The 6SV series adopts optimized extrusion process for larger flow area, plus redesigned pilot housing to realize internal pilot exhaust.

AIRTAC Mainstream Solenoid Valve List & Référence équivalente multimarque

⚠️Important notice: This is functional-equivalent reference only, NOT physical drop-in replacement. Thread size, mounting footprint, manifold compatibility, coil power and Cv flow must be double-checked. Imported and domestic valve manifolds are mostly non-interchangeable; only working conditions are matched.

  1. AIRTAC Solenoid Series Overview
SérieValve FunctionPrincipales fonctionnalitésModèles typiques
4Série V (Legacy, external pilot exhaust)5/2‑way /5/3‑wayExternal pilot exhaust, widely deployed in existing equipment; 4VM manifold base4V110‑06, 4V210‑08, 4V310‑10, 4V410‑15
6SV Series (Nouveau, internal pilot exhaust)5/2‑way /5/3‑wayInternal pilot exhaust, faible puissance, improved dust resistance. Dedicated 6SV200M manifold; incompatible with 4V manifolds6SV110‑06, 6SV210‑08, 6SV310‑10
5Série V (Valve‑island dedicated)5/2‑way /5/3‑wayLow‑power, collective exhaust, high‑density valve island; 5V manifold5V110‑06, 5V210‑08, 5V310‑10
7SV Series (High‑flow)5/2‑way /5/3‑wayDébit élevé, réponse rapide, manifold‑mountable7SV210‑08, 7SV310‑10
3Série V (3/2-chemin)3/2-chemin (single‑acting cylinder)Normally‑Closed NC / Normally‑Open NO; single‑acting cylinder & contrôle du vide3V110‑M5, 3V210‑06, 3V310‑08
4STV/6STV3/2-cheminInternal‑pilot‑exhaust 3/2‑way valve, replacement for legacy 3V series6STV210‑08

Suffix coding rule:

10=Single-solenoid spring-return; 20=Double-solenoid latching; 30C=Closed-center; 30E=Exhaust-center; 30P=Pressure-center

B=DC24V; A=AC220V; F=DC12V; C=AC110V; E=AC24V

  1. Functional Equivalent Cross-Reference Table

1) 5/2-Way Single-Solenoid (Le plus courant)

AIRTAC ModelTaille du portSMC Equivalent ReferenceFESTO Equivalent ReferenceDomestic Equivalent (E‑MC / JELPC)
4V110‑06PT1/8SY3120‑5LZD‑M5VUVG‑S10‑M52‑AT‑G18RV5121‑06 / J4V110‑06
4V210‑08PT1/4SY5120‑5LZD‑01VUVG‑S14‑M52‑AT‑G14RV5221‑08 / J4V210‑08
6SV210‑08 (New internal‑exhaust)PT1/4SY5140‑5LOZ‑01 (internal pilot exhaust)VUVG‑S14‑P53C‑MD‑G14RV5231‑08 (internal‑exhaust low‑power)
4V310‑10PT3/8SY7120‑5LZD‑02VUVG‑S18‑M52‑AT‑G38RV5321‑10 / J4V310‑10
4V410‑15TP1/2SY9120‑5LZD‑03VUVS‑L30‑M52‑AD‑G12RV5421‑15

2) 5/2-Way Double-Solenoid

AIRTAC ModelTaille du portSMC ReferenceFESTO ReferenceDomestic Reference
4V220‑08PT1/4SY5220‑5LZD‑01VUVG‑S14‑B52‑AT‑G14RV5222‑08
6SV220‑08PT1/4SY5240‑5LOZ‑01VUVG‑S14‑P52C‑MD‑G14RV5232‑08

3) 5/3-Way Solenoid Valves (Closed-C / Exhaust-E / Pressure-P Center)

AIRTAC ModelTaille du portSMC ReferenceFESTO ReferenceDomestic Reference
4V230C‑08PT1/4SY5320‑5LZD‑01VUVG‑S14‑T52‑AT‑G14RV5223C‑08
6SV230C‑08PT1/4SY5340‑5LOZ‑01VUVG‑S14‑P53C‑MD‑G14RV5233C‑08

4) 3/2-Way for Single-Acting Actuators

AIRTAC ModelTaille du portSMC ReferenceFESTO ReferenceDomestic Reference
3V210‑08‑NCPT1/4VT310‑5G‑02VUVG‑S14‑A3‑AT‑G14R3V210‑08‑NC

III. Critical Replacement Risk Notes (Selection Pitfalls)

  1. 6SV cannot directly reuse 4V-series manifold bases. 6SV uses internal pilot exhaust; dedicated `6SV200M` manifold required. Legacy 4V uses `4VM` manifold. Mismatched mounting hole pattern causes air leakage if forced assembly.
  2. Internal-exhaust vs external-exhaust:

4V: External pilot exhaust. Vent openings on coil housing; higher risk of spool jamming in dusty environments.

6SV /5V: Internal pilot exhaust. Pilot waste air discharged via main R/S exhaust ports; no vent openings on coil, better for heavy-dust equipment.

  1. Consommation électrique de la bobine:

Legacy 4V DC24V ≈2.8W; 6SV DC24V only 1.2W. PLC output drive capacity must be recalculated for large-scale valve islands.

  1. Physical mounting: SMC SY-series and FESTO VUVG valve islands feature completely different mounting footprints from AIRTAC. Cannot mix-mount on one shared manifold. Replace the whole manifold assembly for functional migration.
  2. 5/3-vanne de voie: Maintain identical center-position function during replacement (C=Closed-center; E=Exhaust-center; P=Pressure-center). Mismatched center function will lead to abnormal machine motion logic.
  3. BOM Full Ordering Examples (for 6SV210-08)

6SV210-08-B: Single-solenoid DC24V, plug-in coil, PT thread (most-used)

6SV210-08B-I: Cable-out coil version

6SV210-08B-D: DIN socket coil version

Matching manifold base: 6SV200M-02 (2-station valve-island sub-base)