Ampèremètre CA de type pointeur Chint 6L2-A 100/5 A

Core Parameters and Application Scenarios Specification Parameterspole box electrical Measuring Range: Connected via a current transformer, the nominal range is 100A (the actual input signal is the 5A secondary current of the transformer). Précision: Classe 1.5, meeting the requirements of conventional industrial measurement. Dimensions hors tout: The mounting hole size is approximately 76mm × 76mm, approprié ...

  • Détails du produit
  1. Core Parameters and Application Scenarios
  2. Paramètres de spécificationpole box electrical

Plage de mesure: Connected via a current transformer, the nominal range is 100A (the actual input signal is the 5A secondary current of the transformer).

Précision: Classe 1.5, meeting the requirements of conventional industrial measurement.

Dimensions hors tout: The mounting hole size is approximately 76mm × 76mm, suitable for installation in standard distribution cabinets.

Environnement de travail: Temperature -5℃ ~ 40℃, humidité ≤ 90%, altitude ≤ 1000 mètres, applicable to indoor environments without strong corrosion.

  1. Applications typiques

Distribution d'énergie industrielle: Monitoring three-phase or single-phase currents of equipment such as motors and transformers, par ex., factory distribution cabinets and building distribution boxes.

Gestion de l'énergie: Cooperating with current transformers (such as Chint RCT series) to realize real-time current monitoring of power systems, supporting lines below 0.66kV.

Alimentation temporaire: Used as a basic current indicating tool in mobile distribution boxes at construction sites and temporary facilities.

  1. Supporting Equipment and Installation Points
  2. Selection of Current Transformer

Modèle recommandé: Chint RCT series annular transformers. The through-hole diameter should match the cable specifications (par ex., RCT-60 is suitable for 60mm wire diameter), with a current ratio of 100/5A and accuracy of Class 0.5.

Exigences de câblage: The secondary side (S1, S2) of the transformer must be connected in series with the ammeter, and the S2 terminal must be reliably grounded to avoid high-voltage hazards caused by open circuits.

  1. Étapes d'installation

Fixation mécanique: Embed the ammeter into the panel of the distribution cabinet, tighten the fixing nuts on the back, and ensure the dial is vertical and flat.

Connexion électrique:

– Connect transformer S1 to the “+” terminal of the ammeter, S2 to the “-” Terminal, and ground it.

– For a three-phase system, three transformers and three ammeters need to be connected separately, paying attention to phase consistency.

Polarity Verification: Before powering on, use a multimeter to check the on-off status of the transformer secondary circuit to ensure there is no short circuit or open circuit.

III. Canaux de prix et d’achat

  1. Cotation du marché

Price per Unit: 19.75 yuan to 39.33 yuan. Les achats en gros peuvent être négociés.

Supporting Cost: The RCT-60 transformer is approximately 50 yuans chacun, and the configuration depends on the number of cables.

  1. Suggestions d'achat

Platform Selection: Industrial product platforms (comme le centre commercial Lichuang) have transparent prices and sufficient spot goods. Plateformes de commerce électronique (Suning, Taobao) are suitable for small-batch purchases.

  1. Troubleshooting and Maintenance
  2. Handling of Common Problems

Pointer Not Moving:

– Check if the transformer secondary circuit is open and if the fuse is blown.

– Test whether there is current on the primary side of the transformer (par ex., using a clamp meter) to rule out faults on the load side.

Abnormal Reading:

– Confirm that the transformer turns ratio matches the ammeter range (par ex., a 100/5A transformer corresponds to the 100A scale).

– Clean the dial glass and pointer to avoid dust affecting observation.

  1. Entretien régulier

Inspection périodique: Clean the housing and terminals every quarter, and calibrate the accuracy every year (entrust a third-party institution if necessary).

Protection de l'environnement: Avoid use in high-temperature, humide, ou des environnements à fortes interférences électromagnétiques. Install a protective cover if necessary.

  1. Upgrade Schemes and Alternative Products
  2. Recommended Intelligent Digital Meters

PA/PZ666 Series: Supports RS485 communication, over-limit alarm, and data transmission, with an accuracy of Class 0.5. Suitable for scenarios requiring remote monitoring, au prix d'environ 60 ~ 120 yuan.

NXBLE Series Circuit Breaker Integration Scheme: Some residual current circuit breakers (such as NXBLE-63) have a built-in current display function, which can replace traditional pointer meters to realize integrated protection and monitoring.

  1. Model Replacement Instructions

– Si le “6L2A” mentioned by the user is an old model, it may correspond to the 6L2-A series. The parameters of the two are compatible and can be directly replaced.

– For high-precision requirements (such as laboratories), it is recommended to choose the 42L6-A series (accuracy Class 1.0), au prix d'environ 22 yuans par unité.

  1. Safety and Compliance Tips
  2. Certifications et normes

– The ammeter complies with the GB/T 13978-2008 standard, and the transformer complies with GB/T 20840.2. Certains modèles ont passé la certification CCC.

– Pour les scénarios d'exportation, models with CE and UL certifications should be selected (such as the international version of Chint RCT series).

  1. Spécifications de fonctionnement

– It is strictly forbidden to disassemble the ammeter when the primary side of the transformer is live; the upper-level power supply must be disconnected first.

– Disconnect the transformer secondary circuit before long-term shutdown to prevent residual magnetism from affecting accuracy.