PNOZ m B0 Base Unit, Numéro de commande. 772100
Famille de produits: PNOZmulti 2 modulaire safety controller (PNOZ m2), configurable multi-function safety relay / compact safety API
- Définition du code modèle
PNOZ: CHAMPIGNON safety relay series identifier
m: Multi, modular configurable system
B0: Unité de base 0, entry-level host without onboard fieldbus
772100: Unique material order number
- Spécifications techniques de base
- Alimentation: 24 À DC
- Onboard Inputs: 8 safe digital inputs
- Sorties intégrées:
4 safe semiconductor outputs (OSSD)
- Communication: No integrated fieldbus interface (only B1/B2 models come with Profinet/EtherCAT onboard)
- Programmation: Configured via PNOZmulti Configurator, program downloaded over USB port
- Performances de sécurité: PL e / SIL 3 (per EN ISO 13849 & CEI 61508)
- Température de fonctionnement: -10℃ ~ +55℃
- Montage: Montage sur rail DIN
- Évaluation du boîtier: IP20 (pour installation en armoire uniquement)
- Stockage du programme: carte SD; program can be copied to another identical unit directly via card swapping
- Fonctions & Applications typiques
Monitoring emergency stop pushbuttons, safety gate switches, safety light curtains, tapis de sécurité, two-hand control stations
Safety logic: AND/OR operations, time delay, verrouillage, safety counter, sélection des modes (automatique/manuel)
Target Equipment: Machines-outils, machines d'emballage, lignes de production automatisées, systèmes de convoyeurs, robot peripheral safety protection
Key Feature: Modular architecture; I/O expansion modules can be added later.
Note: PNOZ m B0 has no built-in bus interface and only supports local I/O. For fieldbus communication, select PNOZ m B1 (772100, Profinet) or PNOZ m B2 (772102, EtherCAT).
- Composants correspondants
Modules d'extension (PNOZmulti 2 série, mounted on the right side of 772100)
Extension d'entrée numérique: 772110
Relay output expansion: 772120
Semiconductor output expansion: 772121
Logiciel
PNOZmulti Configurator (free download from PILZ official website; supports PNOZmulti Classic and PNOZmulti 2)
Migration du programme
Programs can be copied directly via SD card; identique 772100 units run the program immediately after card insertion. Migration to B1/B2 bus versions requires hardware reconfiguration inside the software.
- On-Site Troubleshooting Guide
- No POWER LED: Check 24 V DC polarity, fusibles, terminal wiring and power supply ripple
- Constant ERR LED: Program configuration error, corrupted SD card or hardware fault; read diagnostic data via software
- No response from safety inputs: Check dual-channel wiring continuity, courts-circuits, contact polarity and input filter parameters
- OSSD semiconductor outputs fail to energize: Safety logic conditions not met, output overload or short circuit; verify load status
- Cross-Model Alternatives & Competitor Products
In-Series Upgrade
PNOZ m B1 (772101): Profinet interface
PNOZ m B2 (772102): EtherCAT FSoE interface
Équivalents multimarques
Schneider Electric XPSM series
Siemens F30 safety relay modules
IFM safety controllers
Domestic Replacements
Configurable safety controllers certified up to PL e / SIL 3.
Limitation: Different software, certification and terminal definitions; projects cannot be migrated directly and require full reconfiguration.
PNOZmulti 2 (PNOZ m2) Liste complète des modèles (Numéro de commande. 7721xx)
Base Units (Gauche: modules de bus; Droite: I/O expansion modules)
| Modèle | Numéro de commande. | Description de la clé | Max.. Modules d'extension |
| PNOZ m B0 | 772100 | Entry model without onboard bus; 8DEPUIS + 4OSSD; USB + carte SD; cette unité | Jusqu'à 6 safety I/O modules on the right |
| PNOZ m B0.1 | 772104 | Compact successor to PNOZmulti Mini; seulement 1 expansion module allowed | Max.. 1 I/O module |
| PNOZ m B1 | 772101 | Dual Profinet + Modbus TCP ports; large project capacity | 12 safety modules + 6 standard modules |
| PNOZ m B1 Burner | 772103 | B1 version dedicated for burner control with certified burner function blocks | Same as B1 |
| PNOZ m B2 | 772102 | Native EtherCAT FSoE onboard | Same as B1 |
| PNOZ m C0 | 772105 | Standalone non-expandable unit; 8DEPUIS + 4OSSD; no expansion capability | 0 modules d'extension |
Right-Side Safe I/O Expansion Modules (PNOZ m EF, PL e / SIL3)
Digital I/O Modules
| Modèle | Numéro de commande. | Configuration des E/S |
| PNOZ m EF 16DI | 772140 | 16 safe digital inputs |
| PNOZ m EF 8DI4DO | 772142 | 8DEPUIS + 4 OSSD semiconductor safety outputs |
| PNOZ m EF 8DI2DOT | 772144 | 8DEPUIS + 2 transistor outputs with test pulses (for press machines) |
| PNOZ m EF 4DI4DOR | 772143 | 4DEPUIS + 4 relay safety outputs (AUCUN contact) |
| PNOZ m EF 4DI4DORD | 772145 | 4DEPUIS + 4 sorties relais (NON + Contacts NF) |
| PNOZ m EF 2DOR | 772146 | 2 independent relay safety outputs |
Safe Analog Input Module
|PNOZ m EF 4AI|772160|4-channel safe analog input (0–10 V / 4–20 mA)|
Motion Monitoring Modules (Safe axis control)
| Modèle | Numéro de commande. | Nombre d'axes |
| PNOZ m EF 1MM | 772170 | 1-axis speed / position monitoring |
| PNOZ m EF 1MM2DO | 772172 | 1 axe + 2 OSSD safety outputs |
| PNOZ m EF 2MM | 772171 | Dual-axis synchronous & speed monitoring |
Right-Side Standard Non-Safe I/O Modules (PNOZ m ES, only supported by B1/B2)
| Modèle | Numéro de commande. | Configuration des E/S |
| PNOZ m ES 16DI | 772182 | 16 standard digital inputs |
| PNOZ m ES 14DO | 772181 | 14 standard semiconductor outputs |
Left-Side Communication & Link Modules
Fieldbus Modules
| Modèle | Numéro de commande. | Type d'autobus |
| PNOZ m ES Profinet | 772138 | Profinet IO (your previously referenced part number) |
| PNOZ m ES EtherCAT | 772132 | EtherCAT |
| PNOZ m ES ETH | 772130 | Standard Ethernet TCP/IP |
| PNOZ m ES Profibus | 772131 | Profibus-DP |
| PNOZ m ES CANopen | 772133 | CANopen |
| PNOZ m ES CC-Link | 772134 | CC-Lien |
| PNOZ m ES Powerlink | 772135 | Ethernet Powerlink |
| PNOZ m ES EtherNet/IP | 772136 | EtherNet/IP |
Safety Interlink Modules (Multi-controller networking)
|PNOZ m EF Multi Link|772120|Interlink multiple PNOZ m2 controllers (cuivre / fibre optic)|
|PNOZ m EF PDP Link|772121|Connect distributed PDP67 remote I/O|
|PNOZ m EF SafetyNET|772122|SafetyNET p safety Ethernet networking (maximum. 16 unités)|
|PNOZ m EF FSoE|772123|EtherCAT FSoE safety communication extension|
Preconfigured Complete Packages
PNOZ m2p: 772100 + 772144 (standard press machine configuration)
PNOZ m2p ETH: 772100 + 772130 + 772144 (press version with Ethernet)
Des pièces de rechange & Accessoires
- Program SD card (not included with base unit; commandé séparément)
- Bornes enfichables: Spring-clamp terminal 783542; borne à vis 793542
- Inter-module jumpers: 779260
Expansion Rules (Critique)
- PNOZ m B0 (772100): Max.. 6 EF safety modules on the right; ES standard I/O modules are NOT supported; seulement 1 bus/link module on the left.
- PNOZ m B1/B2: Max.. 12 EF safety modules + jusqu'à 6 ES standard I/O modules on the right.
- PNOZ m B0.1 (772104): Seulement 1 I/O module allowed; no multi-module cascading.
Application Scenarios for PNOZ m B0 (772100)
- General Safety Monitoring (Most Common Use Case)
It monitors and executes safety logic for these protection devices:
- Dual-channel E-Stop pushbuttons
- Interrupteurs pour barrières de sécurité (PSEN series)
- Barrières immatérielles de sécurité & laser scanners
- Safety mats and safety edges
- Two-hand control buttons (press machine dedicated logic)
- 3-position enabling switches (teach pendant)
- Mode selector switches (auto/manual/jog interlock)
- Reset buttons and muting functions
Supported logic: AND/OR, time delay, verrouillage, edge detection.
The OSSD outputs cut off main contactors or servo enable signals, fully complying with EN ISO 13849 normes de sécurité des machines.
- Industry-Specific Deployments
(1) Machines-outils & Press Equipment
Équipement: Presses mécaniques, hydraulic presses, presses plieuses, cisailles
Monitored signals: Two-hand stations, safety gates, rideaux lumineux, slider position (avec 772170 motion module)
Fonctions de sécurité: Single-stroke operation, anti-repeat stroke, verrouillage, delayed safe stop; pre-certified press function blocks available
Exigence: PL e Category 4; ideal for retrofits replacing multiple discrete safety relays.
(2) Machines d'emballage
Machines: Vertical form-fill-seal machines, horizontal packing machines, case erectors, palettiseurs
Monitored points: Guard doors, feed opening light curtains, Arrêt d'urgence, material muting
Benefit: Consolidate multiple safety door controls into one controller, reduce cabinet wiring and simplify fault diagnosis.
(3) Assembly Workstations & Robot Cells
Applications: Standalone robot cells, conveyor stations, fixation & postes d'essais
Protection: Fence safety gates, laser area scanners, teach pendant enable switches, multi-zone safety interlocking
Mise à niveau facultative: Installer 772138 Profinet module on the left to transmit safety status and fault codes to the main PLC and HMI for remote diagnostics.
(4) Manutention des matériaux & Automatisation de la logistique
Équipement: Convoyeurs à bande, lignes à rouleaux, transfer lifts, systèmes de tri
Use case: Multiple E-stops along the line, access door interlocks, sectional safe stop; distinguish local shutdown from global emergency stop.
(5) Caoutchouc & Plastiques / Injection Molding Machines
Injection moulders and extruders: Guard door interlocks, hopper protection, mould area light curtains, mould safety interlock and safety time delay.
(6) Thermal Processing / Furnace Systems (DANS 298 Conforme)
Small heating furnaces: Monitor air pressure, flame signals, safety valve interlocks and burner safety chains.
Note: Multi-burner large furnace systems should select the B1 Burner variant.
- Two Standard Engineering Configurations
Mode 1: Standalone Base Unit (No Expansion Modules)
8 safe DI + 4 OSSD onboard I/O.
Best for small standalone machines: 1~2 safety gates + 1 rideau lumineux + E-stop with simple logic, économiser de l'espace dans l'armoire.
Mode 2: With Right-Side EF Expansion Modules (Max.. 6 Modules)
Expandable for:
Extra digital inputs / sorties relais
Safe analog modules (température & pressure safety monitoring)
Safe motion control modules (vitesse, position and safe speed limitation)
Suitable for medium-sized machines with multiple guard points and axis safety monitoring.
- Rénovation & Machine Modernisation Projects
Perfect for legacy equipment upgrades:
Replace dozens of discrete safety relays with one controller, simplify wiring and reduce troubleshooting time.
Logic is software-configured; the built-in LCD directly pinpoints fault locations, cutting spare part varieties.
Program backup via SD card; replacement units run immediately after card insertion.
- Selection Boundaries (When NOT to choose 772100)
- Large production lines with high I/O count and demand for standard non-safety I/O → Choose PNOZ m B1 (772101)
- Native EtherCAT FSoE bus required → Choose PNOZ m B2 (772102)
- Minimal safety points with zero expansion needed → Compact PNOZ m C0 (772105)
- Multi-burner furnace systems → PNOZ m B1 Burner
- Bus Communication Solution: 772100 + 772138
Install the PNOZ m ES Profinet (772138) module on the left slot of PNOZ m B0:
Hardwired local safety cut-off remains fully independent. Safety status, fault codes and I/O states are uploaded to the main PLC via Profinet.
The PLC only performs monitoring; safety shutdown never relies on fieldbus communication, fully complying with functional safety regulations.
Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur




















NH42-63-318x560.png)