Chint NXB63-1P/D10 is a disjoncteur miniature suitable for residential, industriel, and commercial scenarios. Il est principalement utilisé pour la protection contre les surcharges, protection contre les courts-circuits, and isolation of electrical circuits.
je. Analysis of Core Parameters
1. Signification du modèle
– **NXB-63**: Nom de la série, with a frame current of 63A, suitable for circuits with a rated current ≤ 63A.
– **1P**: Single-pole design, which only controls the live wire and occupies 1 module (18mm de largeur).
– **D10**: D-type tripping curve with a rated current of 10A. The D-type curve is applicable to **loads with high inrush current**, comme les moteurs, transformateurs, and solenoid valves. Its instantaneous tripping range is **10-20 times the rated current** (c'est-à-dire, rapid tripping occurs when the current is 100-200A), which can effectively avoid false tripping during motor startup.
2. Performances électriques
– **Rated Voltage**: C.A. 230 V (adapté aux circuits monophasés).
– **Breaking Capacity**: 6le (conforme à GB/T 10963.1 et CEI 60898-1 normes), capable of safely interrupting the circuit when the short-circuit current is ≤ 6kA.
– **Service Life**: Durée de vie mécanique de 20,000 operations and electrical life of 10,000 opérations, meeting the requirements of long-term use.
3. Certifications et normes
– Il a passé la certification CCC (Certification obligatoire en Chine) and complies with the CE standard (for some export models), ensuring product quality and safety.
II. Scénarios d'application et recommandations de sélection
1. Applications typiques
– **Power Equipment Protection**: Such as small motors (power ≤ 2.2kW; a 10A circuit breaker is suitable for approximately a 2.2kW three-phase motor or a 1.5kW single-phase motor), air-conditioning compressors, pompes à eau, etc..
– **Industrial Control Circuits**: Protecting equipment prone to surge currents, such as solenoid valves and transformers.
– **Residential Power Distribution**: Can be used for branches of high-power electrical appliances (par ex., fours, chauffe-eau électriques), but it should be noted that in single-phase circuits, it needs to be used with a neutral terminal block.
2. Notes de sélection
– **Load Current Matching**: Ensure that the normal operating current of the circuit is ≤ 10A, and the peak starting current of the motor does not exceed the tripping curve range (100-200UN).
– **Breaking Capacity Adaptation**: Select the breaking capacity according to the short-circuit current level at the installation location. If the short-circuit current may exceed 6kA, it is necessary to upgrade to the **NXB-63H series** (avec un pouvoir de coupure de 10kA).
– **Installation Compatibility**: The NXB-63 series is compatible with the DZ47 series in terms of DIN rail installation dimensions (18mm per pole). Cependant, the terminal design of the NXB series is more compact and can accommodate thicker wires (par ex., 4mm²).
III. Price and Market Supply
1. Gamme de prix
– The retail price per unit is approximately **5-20 RMB**, which varies depending on the procurement channel:
– Plateformes de commerce électronique (par ex., 1688, Lichuang Mall): Environ 5-6 RMB par unité.
– Offline distributors or brand flagship stores: Environ 15-20 RMB par unité.
– Discounts are available for bulk purchases (par ex., a box of 20 unités), et le prix unitaire peut être réduit à 4-5 RMB.
2. Inventory and Alternative Models
– **Inventory Status**: Dans 2025, the market supply is sufficient, and mainstream platforms have spot goods available.
– **Alternative Solutions**: Pour un pouvoir de coupure plus élevé, the **NXB-63H 1P D10** (with a breaking capacity of 10kA and a price of approximately 10-15 RMB par unité) peut être sélectionné; for leakage protection, it can be matched with the **NXBLE-63 series residual current circuit breaker** (par ex., 1P+N C10 30mA).
Iv. Installation and Usage Tips
1. Étapes d'installation
– Ensure operation is performed after power-off. Clip the circuit breaker onto the 35mm standard DIN rail and tighten the terminal blocks (it is recommended to use a screwdriver with a torque ≤ 0.5N·m).
– A single-pole circuit breaker only controls the live wire; the neutral wire must be connected through a neutral terminal block to prevent electrical appliances from being charged due to neutral wire disconnection.
2. Recommandations d'entretien
– Regularly check for signs of oxidation or overheating on the contacts, and operate the circuit breaker 2-3 times a year to maintain mechanical flexibility.
– Si des déclenchements fréquents se produisent, it is necessary to check whether the load is overloaded, or if there is a line short-circuit or ground fault.
3. Précautions de sécurité
– Replacing the circuit breaker while it is energized is strictly prohibited; the operation must be performed by a professional electrician.
– Avoid installation in humid environments; if outdoor use is required, a supporting waterproof distribution box must be used.
V. Comparaison avec les concurrents
| Modèle | Courbe de déclenchement | Capacité de coupure | Prix (RMB/Unit) | Scénarios d'application |
| Chint NXB63-1P/D10 | Type D | 6le | 5-20RMB | High inrush current loads (par ex., moteurs) |
| Schneider iC65N 1P D10 | Type D | 6le | 15-30RMB | High-end residences, precision equipment |
| Delixi CDB6-1P/D10 | Type D | 6le | 6-12RMB | Residential and small industrial scenarios |
Résumé
With its high cost-effectiveness, reliable D-type tripping protection, et une large compatibilité, the Chint NXB63-1P/D10 has become the preferred choice for power circuit protection. Pendant la sélection, the breaking capacity should be reasonably chosen based on load characteristics and short-circuit current, and attention should be paid to installation specifications to ensure safety. Pour la protection contre les fuites, it is recommended to use it with the NXBLE series residual current circuit breaker.