Delta AH16AM10N-5A Digital Input DI Module - Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

Delta AH16AM10N-5A Digital Input DI Module - Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur

API/

Delta AH16AM10N-5A Digital Input DI Module

AH 16 SUIS 1 0 N 5A AH: AH500 high-end modular PLC series 16: Total des points d'E/S = 16 points AM: Digital Input module 1: Entrée DC24V 0: No output channels N: No output type 5A: Removable terminal block (JIS terminal) 📋 Core Technical Specifications Points: 16-point DC24V Digital Input (DEPUIS) Tension d'entrée: DC24V, Saisir ...

  • Détails du produit

AH 16 SUIS 1 0 N 5A

AH: AH500 high-end modular PLC série

16: Total des points d'E/S = 16 points

SUIS: Digital Input module

1: Entrée DC24V

0: No output channels

N: No output type

5UN: Removable terminal block (JIS terminal)

📋 Spécifications techniques de base

Points: 16-point DC24V Digital Input (DEPUIS)

Tension d'entrée: DC24V, Courant d'entrée: 5mA

Type d'entrée: NPN/PNP compatible (Sink/Source universal). No hardware rewiring required to switch between sink/source capteurs.

Fonctionnalité: Compatible échange à chaud, modules can be replaced without system power-off for convenient maintenance.

Status Indicator: Independent LED status indicator per channel

Consommation d'énergie: 0.1W, maximum. 1.9W for the module

Dimensions (H×L×P): 110 × 35 × 103 mm

Montage: AH500 local backplane / expansion backplane; numérique, analog and motion modules can be mixed on the same backplane.

Logiciel de programmation: FAISoft

📌 Product Features

  1. Remplacement à chaud: Modules can be installed/removed while the system remains powered on to minimize production downtime.
  2. Entrée universelle: Compatible with 2-wire / 3-wire proximity sensors, capteurs photoélectriques, interrupteurs de fin de course, pushbuttons and other 24V sensors.
  3. Removable Terminal Block: The terminal strip can be detached as a whole, simplifying wiring construction and on-site troubleshooting.
  4. High-integration AH500 Platform: Can be paired with AH-series CPUs, AH16ANxx output modules, AD/DA analog modules and EtherCAT motion modules for mixed expansion.

🏭 Typical Application Scenarios

Machines d'emballage, équipement textile, machines à imprimer, traitement de l'eau, automated production lines and machine tool I/O signal acquisition. Used to collect signals from limit switches, capteurs photoélectriques, détecteurs de proximité, valve feedback and pushbutton DI signals.

🔁 Cross-series Comparison & Sélection alternative

AH16AM10N-5A: 16-point DC24V DI with removable terminal block

AH32AM10N-5B: 32-point DC24V DI with DB37 connector

AH16AN01P-5A: 16-point PNP transistor DO output module (for matching use)

⚠️ Troubleshooting Guide

  1. Input LED not lit: Check DC24V power supply, S/S common terminal wiring of sensors and verify NPN/PNP matching.
  2. Flickering signals: Caused by unshielded sensor cables, voltage drop or loose terminals.
  3. Module not recognized: Poor backplane contact or mismatched module firmware version. Hot-swap function requires AH500 CPU firmware that supports hot swapping.

Delta AH16AM10N-5A Application Cases (AH500 16-point DI Module)

The AH16AM10N-5A is a DC24V digital input expansion module for the AH500 PLC system. Its core function is to acquire switching signals from field sensors, interrupteurs de fin de course, pushbuttons and valve feedback. Hot swap and NPN/PNP universal compatibility are key advantages for site selection. Below are 5 practical engineering cases.

Cas 1: 3D Printing Equipment (Classic Application of AH16AM10N-5A)

System Hardware List

AHCPU530-EN (AH500 CPU)

AHPS05-5A Power Supply + AHBP08M1 Backplane

AH16AM10N-5A ×1 (DI signal acquisition)

AH16AN01T-5A Transistor DO Output Module

AHMC20A DMCNET motion module, module de contrôle de la température

Signal Assignment for AH16AM10N-5A (16 Points)

  1. X0 ~ X3: Home position, positive/negative hard limit for 3 axes
  2. X4~X7: Print head abnormal temperature, filament break detection, low material sensor
  3. X8~X11: Safety door, arrêt d'urgence, reset and start pushbuttons
  4. X12~X15: Platform in-position, material bin presence, fan feedback, alarm reset

Points forts de la solution

NPN/PNP compatibility supports mixed use of photoelectric and proximity sensors from different brands.

Hot-swap capability allows equipment maintenance without full machine power-off.

Collected DI signals are sent to AH500 to realize axis linkage control together with the motion module.

But: Collect safety signals, position sensors and material detection switches as interlock conditions for motion control.

Cas 2: Food Packaging Machine / Machine verticale de formage-remplissage-scellage

Architecture du système

AH500 CPU + AH16AM10N-5A + AH16AN01P Output Module + Delta-Servo + DOP HMI

16-Point DI Assignment

Capteurs photoélectriques: Bag presence detection, material falling detection

Capteurs de proximité: Film feeding in-position, cutter home position, gripper home position

Switches: Safety door, arrêt d'urgence, manual/auto selector, boutons poussoirs marche/arrêt

Feedback signals: Solenoid valve action feedback, air pressure switch

Valeur de l'application

Packaging machines are equipped with large quantities of sensors. The removable terminal block enables batch wiring for high efficiency. Faulty modules can be hot-swapped during production to reduce downtime. DI signals implement interlock logic: cutter movement is disabled if the safety door is open.

Cas 3: Water Plant / Traitement des eaux usées (Automatisation des processus)

AH500 projects in Fujian and Jiangxi water plants deploy multiple AH16AM10N-5A modules to collect signals for pump rooms, chemical dosing rooms and filter tanks.

Collected Signals

Pump running feedback and fault dry-contact signals

Valve open / closed position feedback (electric butterfly valves)

High/low level float switches, differential pressure switches

Local control cabinet pushbuttons, manual/auto selector switches

Solution Features

Field signals are widely dispersed; extension cables for backplane can reach up to 100m.

Multiple AH16AM10N-5A modules expand DI points to acquire massive pump and valve status data.

Signals are transmitted via Ethernet from AH500 to DIAView SCADA for remote pump room monitoring.

Cas 4: Automotive Interior Assembly Line (Multi-station Automation)

Aperçu du projet: Dashboard assembly line with 26 workstations. AH500 acts as the main controller. Each workstation uses one AH16AM10N-5A to collect workstation sensor signals.

DI Acquisition Content

Pallet in-position, workpiece presence photoelectric sensors

Cylinder limit switches, fixture clamp/release feedback

Safety light curtain signals, arrêt d'urgence, workstation request signals

Avantages

NPN/PNP universal design allows mixed sensors from multiple suppliers without hardware modification. Module LED indicators speed up fault point location. Multiple AH16AM10N-5A modules expand I/O capacity, and one AH500 can control multiple assembly stations.

Cas 5: Warehouse Stacker / Palletizing Robot

Configuration matérielle

AH500 motion CPU + AH16AM10N-5A DI Module + AH-series motion modules

Signal Acquisition

Origin and overtravel limit for stacker travelling, lifting and fork axes

Cargo detection photoelectric sensor, fork occupancy detection

Circuit de sécurité: arrêt d'urgence, porte de sécurité, anti-collision sensor

Manual operation box pushbutton signals

Logique de contrôle

AH16AM10N-5A collects limit and safety signals as hardware interlock for motion commands. Servo motion output is immediately cut off once limits are triggered to prevent stacker rail collision.

✅ Common Advantages of AH16AM10N-5A in Projects

  1. NPN/PNP Universal: Mixed sensors from different brands in projects without rewiring.
  2. Remplacement à chaud: Maintain production equipment without shutdown, the core selling point of AH500 modules.
  3. Removable Terminals: Pre-wiring in control cabinets improves on-site installation and commissioning efficiency.
  4. 16 DI points per module with moderate capacity, ideal for I/O expansion of small & medium workstations and standalone machines. Additional modules can be mounted on AH backplanes for more points.

📌 Typical Configuration Reference (Standalone Machine Scheme)

AHCPU510-EN + AHPS05-5A + AHBP04M Backplane + AH16AM10N-5A + AH16AN01P-5A

Application: Standalone automation, machines-outils, machines d'emballage, special-purpose machinery

🔎 On-site Commissioning Tips for Project Deployment

  1. S/S common terminal of sensors: Connect 24V for NPN sensors, connect 0V for PNP sensors. No DIP switch adjustment required on AH16AM10N-5A.
  2. Use shielded cable with grounding for long sensor wiring to prevent DI signal flickering.
  3. Hot-swap function requires compatible firmware version of AH500 CPU. Old firmware needs upgrading to support live module replacement.

Delta AH500 Series Digital I/O Module Full List (Same Series as AH16AM10N-5A, All Hot-Swap Supported)

Suffix Explanation

5UN: Removable detachable terminal block (le plus courant, same terminal type as AH16AM10N-5A)

5B: DB37 pin connector

5C: IDC header

  1. Digital Input Modules AM (DEPUIS)
ModèlePointsSpécificationInterface
AH16AM10N-5A16 pointsDC24V DI, NPN/PNP compatibleRemovable terminal
AH16AM30N-5A16 pointsAC120~240V AC inputRemovable terminal
AH32AM10N-5A32 pointsDC24V DI, NPN/PNP compatibleRemovable terminal
AH32AM10N-5B32 pointsDC24V DI, NPN/PNP compatibleDB37 connector
AH32AM10N-5C32 pointsDC24V DI, NPN/PNP compatibleIDC header
AH64AM10N-5C64 pointsDC24V DI, NPN/PNP compatibleIDC header
AH16AR10N-5A16 pointsDC24V High-speed interrupt DIRemovable terminal
  1. Digital Output Modules AN (FAIRE)
ModèlePointsSpécificationInterface
AH16AN01R-5A16 pointsRelay output 2ARemovable terminal
AH16AN01T-5A16 pointsNPN transistor 0.5ARemovable terminal
AH16AN01P-5A16 pointsPNP transistor 0.5ARemovable terminal
AH16AN01S-5A16 pointsTRIAC AC outputRemovable terminal
AH32AN02T-5A32 pointsNPN transistor 0.1ARemovable terminal
AH32AN02T-5B32 pointsNPN transistor 0.1ADB37 connector
AH32AN02T-5C32 pointsNPN transistor 0.1AIDC header
AH32AN02P-5A32 pointsPNP transistor 0.1ARemovable terminal
AH32AN02P-5B32 pointsPNP transistor 0.1ADB37 connector
AH32AN02P-5C32 pointsPNP transistor 0.1AIDC header

III. Mixed I/O Modules AP (Integrated DI+DO)

ModèlePointsSpécificationInterface
AH16AP11R-5A8DI+8DODEPUIS:DC24V / FAIRE:Relay 2ARemovable terminal
AH16AP11T-5A8DI+8DODEPUIS:DC24V / FAIRE:NPN transistor 0.5ARemovable terminal
AH16AP11P-5A8DI+8DODEPUIS:DC24V / FAIRE:PNP transistor 0.5ARemovable terminal

Supporting AH500 Basic System Modules (Full PLC Assembly, Non-DIO)

CPU Units

AHCPU510-EN, AHCPU520-EN, AHCPU530-EN, AHCPU540-EN, AHCPU550-EN, AHCPU560-EN2 (High-end Redundant CPU)

Modules d'alimentation

AHPS05-5A (Standard Power Supply), AHPS15-5A (High-power Power Supply)

Backplanes (Locale / Expansion Backplane)

AHBP04M1, AHBP06M1, AHBP08M1 (Fond de panier standard)

AHBP04MR1-5A / AHBP06ER1-5A / AHBP08ER1-5A (Redundant Backplane)

Other A500 Special Modules (Analogique, Mouvement, Communication)

  1. Analog AIO: AH04AD, AH08AD, AH04DA, AH08DA, AH04PT, AH04TC RTD / Thermocouple Modules
  2. Compteur à grande vitesse: AH02HC-5A 2-channel high-speed counter
  3. Motion Module: AHMC20A (DMCNET motion)
  4. Module de communication: AH10SCM (Port série), AH10EN (Ethernet), AH10DNET DeviceNet

✅ Quick Selection Guide

  1. Standalone machines commonly use AH16AM10N-5A (DEPUIS) + AH16AN01P/T-5A (FAIRE)
  2. Large I/O quantity with DB37 wiring in control cabinets: select suffix 5B
  3. Centralized I/O cabinet with ribbon cable wiring: select suffix 5C IDC header
  4. AC sensor input: AH16AM30N-5A
  5. Mixed small amount DI+DO to save backplane slots: AH16AP series

Précédent:

Laisser une réponse

Laisser un message