Nom complet du produit: MFH-3-1/4-S, Order No.7959, Tiger Classic Series 3/2-way Normally Closed Single Solenoid Électrovanne
⚠️ Valve body does NOT include solenoid coil; la bobine doit être commandée séparément
✅ Key Specifications
| Article | Paramètre |
| Fonction de la vanne | 3/2-chemin, normalement fermé, single stable, retour à ressort |
| Ports | Main ports: G1/4; Pilot port 12 & pilot exhaust port 82: M5 |
| Nominal Flow Rate | 800 l/min |
| Diamètre nominal | 7 mm |
| Pression de fonctionnement | -0.95 ~ 10 bar (vacuum ~1.0 MPa) |
| Pilot Pressure | 1 ~ 8 bar (external pilot supply) |
| Switching Time | 10 MS (energize) / 29 MS (de-energize) |
| Classe de protection | IP65 (with matched coil) |
| Logement | Aluminium moulé sous pression; Joint: NBR nitrile rubber |
| Poids | 320 g |
| Température ambiante | -5 ~ +40℃; Température moyenne -10 ~ +60℃ |
| Moyen | Compressed air ISO 8573-1:2010 [7:4:4], oil lubrication permitted |
| Commande manuelle | Detenting manual pushbutton |
| Montage | Montage sur rail / through-hole mounting, any mounting orientation |
| Certifications | c UL us Recognized, RoHS |
📌 Model Code Explanation
MFH: Tiger Classic series solenoid valve
3: 3/2-vanne de voie
1/4: Main port thread G1/4
S: External pilot supply version
🛠️ Application Scenarios
Single-acting cylinder control, vacuum circuit, air blow-off/shutoff, machines d'emballage, machine tool pneumatic circuits, air switches for automated production lines.
External pilot: Cannot be driven directly by low-pressure vacuum. Pilot supply must be independently supplied with ≥1bar control air.
🔁 Same Series Reference (Numéro de commande)
7958: MFH-3-1/8-S (G1/8)
7959: MFH-3-1/4-S (G1/4)
7960: MFH-3-1/2-S (G1/2)
⚠️ Sélection & Notes d'entretien
- Solenoid coil must be purchased separately (par exemple. MSFW series, AC220V / DC24V). Valve body comes without coil;
- External pilot structure, independent pilot air supply, works reliably even when main circuit is under negative pressure;
- Poppet valve design with soft seal: excellent sealing performance, but vulnerable to wear if medium contains heavy dust;
- Second-hand inspection focus: manual button operation, air tightness test (pressurize port 1: no output at port 2 when de-energized, air output at port 2 when energized).
FAIRE LA FÊTE 7959 (MFH-3-1/4-S) Cas de candidature
Core advantage: External pilot 3/2-way normally closed poppet valve, compatible with vacuum in main circuit, high flow rate 800L/min; independent pilot air supply via M5 port ≥1bar. This is the biggest difference from standard internal-pilot MFH valves.
Cas 1: Packaging Machine|Single-acting Clamping Cylinder Control (Le plus courant)
Équipement: Horizontal form-fill-seal machine, vertical bagging machine, carton folding machine
Circuit: 7959 → Single-acting spring return clamping cylinder
Bobine alimentée: Valve shifts, compressed air enters cylinder cap end, workpiece clamped;
Bobine hors tension: Valve resets, cylinder chamber exhausts, spring releases workpiece.
Raisons de la sélection
- G1/4 high flow, fast clamping response; detent manual button allows manual clamping test during commissioning;
- Soft seal poppet valve, low leakage after long frequent cycling;
- PAL rail manifold mountable, multiple valves mounted side-by-side for centralized air supply and exhaust.
Note: Pilot air shall be taken from a separate clean air source, not shared with main cylinder air supply.
Cas 2: Prise sous vide & Place Circuit (Representative Application of This Valve)
Équipement: PCB mounter, carton feeding manipulator, plastic part handling suction cup module
Circuit: Vacuum generator → 7959 valve → Vacuum suction cup
Hors tension: Valve closed, suction cup disconnected from vacuum source, suction cup vented to atmosphere, pièce libérée;
Énergisé: Valve opens, vacuum connected to suction cup, workpiece picked up.
✅ Key point: External pilot version allows vacuum in main circuit. Internal-pilot MFH cannot be directly used for vacuum circuits (negative pressure in main circuit causes unreliable shifting). This is the core value of 7959 (suffix -S).
Note: M5 pilot port must be continuously supplied with ≥1bar clean compressed air. Vacuum cannot be used as pilot supply.
Cas 3: Machine Tool|Chip Blow-off & Workpiece Ejection
Équipement: CNC lathe, machining center, stamping machine workpiece blow-off, material bin air separation
Circuit: Main air supply G1/4 → 7959 → Air nozzle
Énergisé: High-flow air jet blows away metal chips or eject finished workpieces out of station;
Hors tension: Air supply cut off, nozzle pressure relieved.
Raisons de la sélection: 800L/min high flow for high intensity short pulse blowing; poppet valve tolerates minor dust for machine tool cutting environment; IP65 allows mounting outside machine cabinet.
Cas 4: Caoutchouc & Plastics Industry|Single-acting Lifting/Ejection Mechanism
Équipement: Injection molding machine mold ejection, rubber molding machine demolding, hot pressing tool lifting
Circuit: 7959 driving large bore single-acting spring return cylinder for mold ejection.
Caractéristiques: Die-cast aluminum housing tolerates oil contamination and elevated temperature in mold environment; valves can be assembled on manifold rail;
Safety merit: Automatic spring reset upon power loss, mold retracts automatically for safety redundancy.
Cas 5: Conveyor Line|Pilot Control for Pneumatic Valves (Used as Pilot Valve)
Équipement: Sorting conveyor, pallet stopper, large bore pneumatic shut-off valve
Circuit: PLC drives 7959; 7959 outputs pneumatic signal to actuate large-size main pneumatic valve.
Scénario: Main valve has huge flow capacity and cannot be directly driven by small solenoid valves; 7959 serves as secondary pilot valve to provide control air signal.
Avantages: 10réponse rapide de Mme, stable pilot output, suitable for 2-stage control of large pneumatic circuits.
Cas 6: Rénovation & Replacement for Legacy Equipment (Spare Part Application)
Many imported automated production lines manufactured from 1990s to 2010 adopt Tiger Classic poppet valves. Damaged MFH-3-1/4-S (7959) peut être directement remplacé.
Industry status: This classic legacy spare part. Specified on drawings of many packaging, machines d'impression et textiles. Supports through-hole mounting or PAL rail mounting; no hole modification required during replacement.
Common Risk Reminders Across All Cases
- Valve body without coil, MSFW coil must be ordered separately (DC24V most popular);
- -S = external pilot, M5 pilot port pressure ≥1bar, pilot air filtration ≥40μm; insufficient pilot pressure causes no shifting or intermittent misfiring;
- Medium must be filtered; dust particles scratch poppet seal and cause internal leakage;
- In vacuum applications, main circuit negative pressure cannot be used for pilot supply; independent positive pressure air source required for pilot.
Industry Summary List
Machines d'emballage: Carton machine, horizontal packaging machine, heat sealer (serrage, vacuum material pick-up)
Machine-outil & Metal Working: Chip blow-off, workpiece ejection
Caoutchouc & Plastics Injection: Mold single-acting ejection
Automatisation de la logistique: Suction cup handling, sorting stopper
Impression & Textile: Fabric clamping, paper stack air separation
Legacy imported equipment maintenance & remplacement (Tiger Classic valve)
Working Principle of MFH-3-1/4-S (Faire la fête 7959)
Répartition du modèle: 3/2-chemin, normalement fermé, single-solenoid spring return, external pilot (-S) poppet solenoid valve
Important: This is an external pilot valve. The solenoid coil only controls pilot air and does NOT directly actuate the main spool, completely different from direct-acting solenoid valves.
- Définition du port (3/2-way Valve)
Port 1: Main air supply inlet (G1/4)
Port 2: Working output port → Connect to cylinder / suction cup / ajutage
Port 3: Port d'échappement (main circuit exhaust)
Port 12: Pilot supply port M5 (external pilot dedicated, must be supplied ≥1bar clean compressed air)
Port 82: Pilot exhaust port M5
Definition of 3/2-way: 3 air ports, 2 working states (de-energized / énergique)
- Two Operating States
✅ State 1: Coil De-energized (Home Position, Normalement fermé)
- Main poppet is pressed against main valve seat by return spring force;
- Circuit principal: Port1 (main supply) ↔ Port2 disconnected; Port2 ↔ Port3 (échappement) connected;
- Pilot circuit: Pilot control chamber exhausted via port82, no pressure inside pilot chamber;
- Résultat:
For single-acting cylinder: Cylinder exhausts and retracts by spring;
For vacuum suction cup: Suction cup vented to atmosphere, pièce libérée.
✅ State 2: Coil Energized (Shifted Position)
- Solenoid coil pulls armature → opens small internal pilot slide valve;
- Compressed air from external pilot supply (port12) enters control chamber of main poppet;
- Pressure from pilot air generates thrust to overcome return spring and shift main poppet;
- Main circuit switching: Port1 ↔ Port2 connected; Port2 ↔ Port3 exhaust port blocked;
- Résultat:
Compressed air flows from port1 to port2 to actuate actuators;
Vacuum circuit: Port2 connected to vacuum source, negative pressure generated at suction cup for workpiece pick-up.
After de-energization, pressure inside control chamber discharges through port82 pilot exhaust port, spring pushes main poppet back to home position, returning to normally closed state.
- Fonctionnalité de base: Principle of External Pilot (-S) (Clé)
Internal pilot valve: Pilot air is tapped from main supply port 1. If main circuit is under vacuum (negative pressure), no positive pressure available at port1 to generate thrust to shift poppet, cannot be used for vacuum circuits.
External pilot (-S): Pilot air is independently supplied from port12, fully isolated from main circuit (port1/2/3).
Main circuit port1 can carry compressed air or vacuum negative pressure. As long as port12 pilot supply maintains ≥1bar positive pressure, reliable valve shifting is guaranteed.
👉 This is the fundamental reason why 7959 can be used in vacuum suction cup circuits.
- Structure Overview (Poppet Valve)
It is a poppet valve, not slide valve: Sealing is achieved by pressing rubber seal against valve seat.
Avantages: Excellent sealing performance, low leakage;
Inconvénients: Sensitive to dust in medium; solid particles may scratch sealing surface and cause internal leakage.
- Manual Override Mechanism
The valve body is equipped with detenting manual pushbutton:
Press and rotate to lock, mechanically actuate pilot spool. Manual shifting available without power or coil energization, used for commissioning, air test and maintenance.
- Concise Principle Comparison Table
| Article | MFH-3-1/4-S (7959 External Pilot) | Standard Internal-pilot MFH Valve |
| Pilot Air Source | Independent supply via M5 port12 | Tapped from main supply port1 |
| Main Circuit Medium | Air comprimé / vacuum available | Compressed air only (positive pressure) |
| Vacuum Circuit Application | ✅ Pris en charge | ❌ Non pris en charge |
| Pilot Pressure Requirement | 1~8bar | Depends on main supply pressure |
Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur
























NH42-63-318x560.png)



