ifm IS-3002-BPKG Rectangular Inductive Proximity Sensor - Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

 ifm IS-3002-BPKG Rectangular Inductive Proximity Sensor - Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur

Capteur/

ifm IS-3002-BPKG Rectangular Inductive Proximity Sensor

(Order designation; core part number: IS5001) Derivatives of the same series: IS5035: IS-3002-BPKG/AS (M8 connector version) IS5068: IS-3002-BPKG/0,3M/AS-610 (0.3m short cable + Connecteur M8) Basic Specifications Type: rectangular inductive proximity sensor, flush mount Rated sensing distance: 2 mm Sortie: 3-wire DC, PNP normally open (NON) Dimensions: 27.8 × 10.2 × 16 mm, ultra-thin rectangular housing ...

  • Détails du produit

(Order designation; core part number: IS5001)

Derivatives of the same series:

IS5035: IS-3002-BPKG/AS (M8 connector version)

IS5068: IS-3002-BPKG/0,3M/AS-610 (0.3m short cable + Connecteur M8)

Spécifications de base

Taper: rectangular inductive proximity sensor, flush mount

Rated sensing distance: 2 mm

Sortir: 3-wire DC, PNP normally open (NON)

Dimensions: 27.8 × 10.2 × 16 mm, ultra-thin rectangular housing for confined installation spaces

Données électriques

Tension d'alimentation: C.C 10 ~ 30 V

Courant à vide: <15mA

Max.. courant de charge: 200 mA

Fréquence de commutation: 800 Hz

Voltage drop: ≤2,5 V

Fonctions de protection: reverse polarity, protection contre les courts-circuits et les surcharges

Hystérèse: 1~15 % of Sr (distance de détection nominale)

Correction factor: steel=1; stainless steel=0.7; brass=0.4; aluminium=0.3; copper=0.2

Environnemental & Données mécaniques

Indice de protection: IP67

Température de fonctionnement: -25 ℃ ~ +80 ℃

Matériau du boîtier: PBT

Max.. couple de serrage: <0.5 N·m (use flat washers)

Indication d'état: yellow LED

Connexion (standard IS5001): 2 m fixed PVC cable, 3×0.14 mm²

NE (Brun): L+ positive supply

CE (Bleu): 0V ground

BK (Noir): Sortie de signal PNP

Key Application Keywords

Jig positioning, cylinder end-position detection, conveyor line counting, machine tool limit monitoring, metal detection in narrow spaces, material handling position feedback, signal acquisition for automated machinery

Sélection & Notes de remplacement

  1. Suffix definition: no suffix = 2m fixed cable; `/AS` = M8 3-pin straight connector; `/0,3M` = short lead
  2. Domestic equivalent replacement: rectangular inductive proximity sensor with identical size, 2mm flush-shielded, Sortie PNP NO
  3. Installation note: flush mount; sensing face can be embedded into metal brackets without reduction of rated sensing distance.

Guide de dépannage

Aucune sortie: first check 24V power supply and polarity; verify no reverse wiring

Unstable signal: check voltage drop, gap between sensor and metal target, nearby strong magnetic interference and mounting clearance

LED does not light up: missing power supply or internal short circuit

  1. NPN Version with Identical Mechanical Outline (IS Series, 27.8×10.2×16, flush 2mm, 3-wire DC)

Remarque: IS series is originally PNP dominant; NPN models carry suffix BOKG

IS5002: IS-3002-BOKG, NPN normally open, 2m PVC cable; fully interchangeable with IS5001 with identical mounting holes

IS5036: IS-3002-BOKG/AS, NPN NON, M8 3-pin straight connector (counterpart of IS5035)

IS5069: IS-3002-BOKG/0,3M/AS-610, 0.3m short cable + Connecteur M8 (counterpart of IS5068)

Câblage: BN=L+, BU=0V, BK=NPN output; supply 10~30V DC. All other parameters (switching frequency, plage de température, IP67, protection) match IS5001 completely.

III. Domestic Replacement List (Recommandé, pin-to-pin compatible, 2mm flush-shielded)

Selection criteria: 27.8×10.2×16 outline, flush shielded, 2mm distance de détection, DC10–30V, IP67, switching frequency ≥800Hz

  1. Sodron SN08Y-02BPA (PNP NON) / SN08Y-02BNA (NPN NON)

On-site Installation Guidelines

  1. Couple de serrage

Boîtier en plastique PBT; tightening torque must be below 0.5 N·m to prevent cracking; use thin flat washers to disperse clamping force.

  1. Acheminement des câbles & câblage

Standard 2m PVC cable (3×0.14 mm²);

Brown = +24V, Blue = 0V, Black = PNP signal;

Avoid routing alongside power cables and servo motor wires to prevent EMI interference. Use shielded cable or signal filters for long-distance wiring.

Built-in short-circuit & protection contre l'inversion de polarité; avoid hot-plugging under power.

  1. Adéquation environnementale

Classé IP67; résistant au liquide de coupe, cooling water and dust. Not suitable for continuous immersion or strong corrosive solvents (acetone, strong acid/alkali).

Plage de température ambiante: -25~+80 ℃; add heat insulation if installed near heating blocks or injection mould slides.

  1. Gap adjustment

Recommended working gap: 0.5~1.2 mm (leave safety margin). Do not operate continuously at the maximum 2mm gap; vibration will cause signal dropout.

Yellow LED lights up when metal is detected; use the LED for quick commissioning.

  1. Switching frequency limit

Fréquence nominale: 800 Hz (maximum 800 pulses per second). For field application, limit the frequency to ≤400 Hz. Not recommended for high-speed pulse counting or high-frequency vibration detection.

  1. Important Limitation

This is a standard position sensor, NOT a safety-rated device. Do not connect it to safety circuits, safety gates or emergency stop protection loops.

Only detects ferrous/non-ferrous metals; no response to plastic, film or wood.

Tableau de comparaison: IS5001 Ultra-Thin Rectangular vs Standard Cylindrical Proximity Sensors

ArticleIS5001 IS-3002-BPKG Ultra-Thin RectangularStandard M8/M12 Cylindrical Inductive Sensor (par exemple. ifm IE5001)
Dimensions27.8×10.2×16 mm, ultra-flatCylindrical M8/M12/M18; requires radial installation space
MontageFlush shielded; fits narrow slots, cylinder side faces and gripper gapsFlush / non-flush options; threaded body requires radial clearance
Distance de détectionFixé 2 mmM8:1.5~2 mm; M12:4 mm; M18:8 mm; multiple range options
Fréquence de commutation800 HzM8 typically 2000 Hz; M12 approx 1000 Hz; wider high-frequency options
Fixing methodSide-mounted with screwsThreaded screw-in + lock nut; installation plus rapide
AvantagesUltra-thin body, ideal for space-critical locations; flush mounting prevents collision damageWide model range, flexible sensing distances, universal spare parts, fast commissioning, broad price options
InconvénientsLong body despite thin thickness; short 2mm sensing range; higher price than M8 typesRadial protrusion; prone to collision on slim cylinders and compact grippers
Applications typiquesSlim cylinders, finger grippers, narrow-slot jigs, small tool magazine positionsGeneral limit detection, comptage sur convoyeur, machinery with ample mounting space
ProtectionIP67Mostly IP67
SortirPNP NON (NPN version IS5002 available with same outline)PNP/NPN, NON/NF; full output options
Side Metal ImmunityFlush-shielded (can be embedded in metal brackets); keep ≥5mm clearance from side metalFlush types can be embedded; non-flush types require large metal clearance

Guide de sélection rapide

✅ Choose IS5001: Mounting space is extremely tight; M8 cylinder cannot fit; only 2mm metal position feedback is needed

✅ Choose M8 cylindrical: Sufficient space, higher response frequency, quick threaded installation and universal spare parts are prioritized

✅ Choose M12/M18: Distance de détection plus longue (4mm / 8mm) est requis

Commissioning Toolkit (Utilisation sur le terrain)

24Alimentation V CC & multimètre (for output voltage measurement)

Thin flat washers + tournevis dynamométrique (to control torque below 0.5 N·m)

Acier & aluminium test pieces (pre-test signal attenuation on non-ferrous metals)

Précédent:

Laisser une réponse

Laisser un message