M18 Flush-mount Inductive Proximity Switch (2-wire AC/DC universal, Normalement ouvert NON)
- Explication du code modèle
XS6: Usage général inductive proximity sensor of XS6 series
18: M18 threaded cylinder
B: Standard sensing distance
1: Normalement ouvert (NON)
M.: 2-wire AC/DC universal
UN: Cable outlet
L2: 2-meter fixed cable
- Électricité de base & Spécifications mécaniques
| Article | Paramètre |
| Nominal Sensing Distance Sn | 8 mm, flush mounting (shielded type) |
| Tension d'alimentation | 24…240 V AC/DC (50/60Hz) |
| Type de sortie | 2-fil, Normalement ouvert (NON) |
| Courant de charge | CC: 5~200mA; CA: 5~300mA |
| Body Length | 62 mm; Thread M18×1 |
| Matériau du boîtier | Nickel-plated brass; Sensing face PPS |
| Câble | 2m de câble fixe |
| Classe de protection | IP68 / IP69K, double insulation |
| Température de fonctionnement | -25℃ ~ +70℃ |
| Fréquence de commutation | 1kHz |
| Detected Object | Metallic conductors (optimal for ferromagnetic metals) |
- Directives d'installation
- Montage encastré (Shielded Type): The sensor can be fully embedded inside a metal mounting seat without false triggering caused by side metal.
- Mounting hole M18, supplied with double lock nuts.
- Minimum spacing between adjacent sensors of the same model ≥3×Sn (≥24mm) to prevent mutual interference.
- Target metal plate thickness ≥1mm, area ≥30×30mm for stable detection.
- Instructions de câblage
2-wire design, non polarisé (AC/DC universel):
Connect two wires in series between power supply and load.
When metal approaches the sensing face → switch turns ON (NO contact closed).
Note: 2-wire sensors carry standby leakage current. False actuation may occur with low-power loads (high-resistance relay coils). Load calculation is required during selection.
- Scénarios d'application typiques
Metal detection on conveyor lines, machine tool limit positioning, material presence detection, hydraulic/cylinder position feedback, food processing washdown equipment (IP69K for high-pressure cleaning), machines d'emballage.
- Alternative / Equivalent Models within the Series
XS618B1MBL2: 2-wire Normally Closed NC, autres paramètres identiques
XS618B1PAM12: 3-wire PNP Normally Open, M12 connector type
XS618B1NAM12: 3-wire NPN Normally Open, M12 connector type
- Dépannage courant
- Aucune sortie: Verify supply voltage within 24~240V; confirm metal target enters the 8mm sensing range; inspect cable for breakage.
- Faux déclenchement: For flush mounting, ensure mounting metal does not cling to the sensing face; check interference from neighboring sensors.
- Cannot turn off: Too small load; leakage current of 2-wire sensor keeps relay energized. Replace with 3-wire PNP/NPN version.
Operating Principle of Flush-mount Inductive Proximity Switches (such as XS618B1MAL2)
Basic Principle
Inductive proximity switches work based on the eddy current effect, with a high-frequency oscillating coil as the core component.
- Internal circuit generates a high-frequency alternating magnetic field, radiating outward from the front sensing face.
- Lorsqu'une cible métallique s'approche de la face de détection, the alternating magnetic field induces eddy currents on the metal surface.
- Eddy currents generate a reverse magnetic field to counteract the original oscillating magnetic field of the sensor.
- The amplitude of the oscillation circuit attenuates; detection circuit identifies this change and outputs switching signal (MARCHE/ARRÊT).
✅ Core difference between Flush-mount (Shielded) and Non-flush (Unshielded): A metal shielding ring surrounds the coil
Structural Features of Flush-mount (Shielded Type)
A metal shielding layer wraps the sides of the sensing coil for flush-mount sensors:
Restricts magnetic field to directly in front of the sensor, nearly no magnetic field on lateral sides.
Donc, it can be fully screwed into metal mounting brackets with sensor end face flush to mounting surface and no false triggering from surrounding metal.
Trade-off: Under identical specifications, sensing distance is shorter than non-flush type (Sn=8mm for XS618B1MAL2 flush model).
Non-flush type: Magnetic field exists on sides; cannot be embedded in metal seat, otherwise continuous triggering occurs, with longer sensing distance.
Signal Output Flow (2-wire NO model XS618B1MAL2)
- Power on → internal oscillator starts oscillation.
- No metal nearby → stable oscillation, switch open (NON Normalement Ouvert).
- Metal approaches and reaches rated sensing distance Sn → oscillation attenuates, detection circuit actuates and the 2-wire circuit conducts.
- Metal moves away → oscillation recovers, switch opens.
Caractéristiques clés
- Only detects metal: Plastique, wood and glass cannot produce eddy currents and will not be detected. Ferromagnetic metals (acier, iron) deliver optimal sensing distance; effective distance attenuates for non-ferrous metals such as copper and aluminum.
- Vitesse de réponse rapide, suitable for high-speed counting and position detection.
- Flush mounting resists side metal interference, preferred for machine tools, conveyor metal frame installations.
- 2-wire version carries leakage current; load selection needs attention.
Simple Comparison Table
| Taper | Structure | Fonction de montage | Distance de détection |
| Flush-mount (Shielded) | Coil with metal shielding ring | Can be flush embedded into metal holes | Shorter |
| Non affleurant (Unshielded) | No side shielding | Cannot embed into metal; front clearance required | Longer |
Common Application Scenarios of Inductive Proximity Switches
Fonctionnalités principales: Detect metal only, non-contact, pas d'usure mécanique, resistant to dust and oil; Flush type (XS618B1MAL2) suitable for flush installation on metal frames
- Détection de position / Limite de voyage (Le plus courant)
- Retour d'information sur la position du cylindre: Detect extended/retracted end position of cylinder piston rod to confirm completion of cylinder action, standard fitting for pneumatic automation; M18 flush sensors widely used on cylinder mounting seats.
- Machine tool travel limit: Soft limit and hard overtravel protection for CNC machine slides and worktables; turret and tool magazine positioning, tool change confirmation; fixture clamping verification to judge workpiece seating status.
- Soupape, baffle and safety door status detection: Detect closure of metal safety gates for safety interlock; equipment startup prohibited when door open.
- Robot positioning: Homing and station in-place detection for robotic arms.
- Compte, Speed Measurement & Rotational Speed Monitoring
- Metal workpiece counting on conveyor lines: Count metal parts, vis, metal caps and metal pallets on production lines for output statistics.
- Rotational speed / line speed acquisition: Gear tooth disc fitted on motor shaft; proximity sensor detects gear teeth pulses, PLC collects pulses to calculate rotation speed and line speed, widely used for conveyors and reducer spindle monitoring.
- Material break / shortage detection: Monitor feeding of metal rods to confirm material delivery and breakage.
- Convoyage & Tri Logistique
- Detect arrival of metal workpieces on belt conveyors to trigger cylinder actions for transfer and sorting;
- Metal pallet presence detection and rack positioning in automated warehouses;
- Jam monitoring: Alarm for material accumulation and blockage.
- Conditionnement & Machines alimentaires (Suitable for XS618B1MAL2 with IP68/IP69K)
Detection of cans, metal caps and aluminum foil seals to verify cap presence;
Trigger filling when metal containers arrive at filling stations;
High-pressure washdown capability; flush sensors preferred for food & beverage cleaning lines.
- Fabrication automobile
Workpiece positioning at welding stations and fixture clamping confirmation for welded car bodies;
Gear position detection for gearboxes and presence check of wheel hubs;
Stable performance under welding slag and heavy dust; inductive sensors outperform photoelectric sensors in contaminated environments.
- Hydraulique & Machines de construction
Hydraulic cylinder position detection and metal float liquid level monitoring;
Position feedback for machinery doors and buckets;
Adapt to heavy vibration and oily harsh environments.
- Other Segmented Applications
- Équipement d'estampage: Mold closure detection and safety interlock;
- Équipement électronique: Metal component detection on SMT lines;
- Pompe & ventilateur: Shaft stall monitoring via gear tooth speed measurement.
Conseils de sélection (For XS618B1MAL2)
✅ Flush-mount (Shielded Type): Can be installed flush within metal mounting seats, free from false triggering by surrounding metal; preferred for machine frames and cylinder mounts.
⚠️ Limitation: Only identifies metal, plastique, paper and non-metallic workpieces cannot be detected; effective sensing distance shortens for copper and aluminum.
⚠️ 2-wire models (par exemple. XS618B1MAL2) have leakage current, which may cause false pull-in of small-load relays.
Télémécanique XS618B1 Series Full Model List (M18 Flush Mount, Sn=8mm)
Unified Base Specification: XS618B1 = XS6 series, M18 threaded, flush shielded type, nominal sensing distance 8mm, boîtier en laiton nickelé, IP68/IP69K, -25~+70℃
Règle de codage du modèle: XS618B1 + Output Code + Type de prise + Length/Connector
M = 2-wire AC/DC; P=PNP; N=NPN
A=Normally Open NO; B=Normally Closed NC
L2=2m cable; L5=5m cable; M12=M12 circular connector; AU20=1/2″UNF connector
- 2-wire AC/DC (Branch of XS618B1MAL2, 24~240 V CA/CC)
| Modèle | Sortir | Câblage | Outlet | Remarques |
| XS618B1MAL2 | NON | 2-fil | 2m de câble | Modèle de référence, Body L=62mm |
| XS618B1MBL2 | Caroline du Nord | 2-fil | 2m de câble | Same specs as MAL2 |
| XS618B1MAU20 | NON | 2-fil | 1/2″UNF connector | American thread connector, L=73mm |
| XS618B1MBU20 | Caroline du Nord | 2-fil | 1/2″UNF connector | Normally closed version with American connector |
- 3-wire DC PNP (12~48VDC, most common for PLC)
| Modèle | Sortir | Câblage | Outlet | Remarques |
| XS618B1PAL2 | NON | 3-wire PNP | 2m de câble | L=62mm |
| XS618B1PBL2 | Caroline du Nord | 3-wire PNP | 2m de câble | L=62mm |
| XS618B1PAL5 | NON | 3-wire PNP | 5m de câble | Long cable version |
| XS618B1PBL5 | Caroline du Nord | 3-wire PNP | 5m de câble | Long cable normally closed |
| XS618B1PAM12 | NON | 3-wire PNP | Connecteur M12 à 4 broches | L=74mm |
| XS618B1PBM12 | Caroline du Nord | 3-wire PNP | Connecteur M12 à 4 broches | L=74mm |
- 3-wire DC NPN (12~48VDC, for NPN-type PLC)
| Modèle | Sortir | Câblage | Outlet | Remarques |
| XS618B1NAL2 | NON | 3-wire NPN | 2m de câble | 62mm body |
| XS618B1NBL2 | Caroline du Nord | 3-wire NPN | 2m de câble | 62mm body |
| XS618B1NAM12 | NON | 3-wire NPN | Connecteur M12 | 74mm body |
| XS618B1NBM12 | Caroline du Nord | 3-wire NPN | Connecteur M12 | 74mm body |
- ATEX Dust Explosion-proof Versions (Explosive Atmosphere)
| Modèle | Sortir | Câblage | Outlet | Remarques |
| XS618B1PAL10EX | NON | PNP | 10m de câble | ATEX dust hazardous area |
| XS618B1PBL10EX | Caroline du Nord | PNP | 10m de câble | ATEX dust hazardous area |
Guide de sélection rapide
- 2-wire models starting with M (XS618B1MAL2): Universal AC/DC, no polarity distinction; ⚠️ leakage current exists, prone to false relay pull-in for tiny loads, adapté aux charges lourdes.
- 3-wire P/N prefix: DC12~48V, PNP/NPN, protection contre les courts-circuits, standard PLC selection, preferred replacement for 2-wire sensors.
- Suffix L2/L5: Fixed cable; M12/AU20: Detachable connector for easier maintenance.
- A=NO Normally Open, B=NC Normally Closed: When metal approaches, NO closes and NC opens.
Extended M18 Flush Models in the Same Series (Longer Sn, Non-B1)
XS618B4PAL2: Flush mount, Sn12mm, PNP NON, 2m de câble
Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur