LS ÉLECTRIQUE (formerly LG Industrial Systems), K120SE series economical CPU module, fin de vie, only stock & second-hand spare parts available on the market. ✅ Model Definition K7M: MASTER-K120S CPU series DR: D = DC24V Input, R = Relay Output 14: Total I/O points =14 (8 Entrées + 6 Sorties) UE: K120SE economical version (Compare with standard ...

  • Détails du produit

LS ÉLECTRIQUE (formerly LG Industrial Systems), K120SE series economical CPU module, fin de vie, only stock & second-hand spare parts available on the market.

✅ Model Definition

K7M: MASTER-K120S CPU series

RD: D = DC24V Input, R = Relay Output

14: Total I/O points =14 (8 Entrées + 6 Sorties)

UE: K120SE economical version (Compare with standard U series, program memory: 2K étapes)

📋 Core Specifications

ArticleParamètre
AlimentationAC85~264V wide range, commonly AC220V
Entrée numérique8 points DC24V, compatible puits/source; Input filter 0~1000ms configurable, default 10ms; Adresse: P000~P007
Sortie numérique6-point relay contact output; Single contact rating: AC250V / DC110V, resistive load 2A; Adresse: P040~P045
Mémoire du programme2K steps for UE economical model; K7M-DR14U standard version:7K étapes
Vitesse d'exécutionBasic instruction: 0.4s per step
Compteur à grande vitesse4 chaînes; single-phase max.100kHz, two-phase 50kHz; supports 10s pulse capture (2 points)
Ports de communicationBuilt-in RS232C + RS485; connect HMI, host PC, multi-PLC 1:N network
Conservation des donnéesSupercapacitor, no battery; data retention approx. 20 days at ambient temperature
ExpansionCompatible with G7E digital modules, G7F analog modules (AD/DA/PT100)
Langage de programmationLadder Diagram LD, Logiciel de programmation: KGLWIN

🧩 Typical Application Scenarios

Small standalone machine control: convoyeurs, small presses, machines d'emballage, simple HVAC, flameproof mining switches, control cabinet accessories. Suitable for digital logic plus limited high-speed counting.

Relay output cannot generate pulse for positioning (DT/DRT transistor model required for positioning)

⚠️ Remarques importantes

  1. Relay output limitation: Contact mécanique, not suitable for frequent on/off operations; max ~1200 switching cycles/hour, frequent operation accelerates contact burnout.
  2. Modèle abandonné: Non recommandé pour les nouveaux projets. For replacement maintenance, verify program capacity first (UE=2K steps, standard DR14U=7K; program exceeding 2K cannot be downloaded directly).
  3. Communication: RS485 uses LS proprietary Cnet protocol, compatible with SCADA & touchscreen.
  4. Built-in DC24V sensor supply: The PLC provides 24VDC for sensors, limited capacity.

📌 K120SE Series Lineup

K7M-DR10UE: 6DI+4DO

K7M-DR14UE: 8DI+6DO

K7M-DR20UE:12DI+8DO

K7M-DR30UE:18DI+12DO

🔁 Alternative Selection

Remplacement domestique: Inovance H1U-0806MR, Xinje XC2-08R-E;

LS upgraded platform: XBC series (XBC-DR14E)

🛠 Common Troubleshooting

  1. PWR lamp off: Alimentation CA, blown internal 2A time-delay fuse
  2. RUN lamp off: erreur de programme, STOP mode via switch/host PC, watchdog overflow
  3. Aucune action de sortie: aged/burned relay contact (common on second-hand units), broken COM wiring
  4. Échec de communication: RS232/485 wiring polarity, numéro de station, débit en bauds, résistance de terminaison

Programming Software for LS K7M-DR14UE (MASTER-K120S)

✅ Official programming software: KGLWIN

XG5000 mentioned before is for XGB/XGT series, not compatible with K120S K7M, do not install the wrong software.

Version Info

Common stable release: KGLWIN 3.62, also 3.5, 3.7 disponible. Originally designed for Win98/XP. Win10/Win11 requires compatibility mode.

Languages: Ladder LD, Instruction List IL

Fonctions: Program edit, moniteur en ligne, I/O force, upload/download, comment, diagnostic de panne

Handheld programmer: KLD-150S (old portable unit for field commissioning)

Online Connection Method

Built-in RS232C programming port on PLC:

  1. Héritage: PC DB9 serial direct cable
  2. Modern PCs without native serial port: USB to RS232 adapter (CH340/PL2303 chip), select corresponding COM port inside KGLWIN

Note: Install driver for USB-serial adapter. Paramètres de communication: 9600 bauds, pas de parité, 8 bits de données,1 peu d'arrêt.

Software Comparison Table

Série APILogiciel de programmation
MASTER-K (K120S/K80S, K7M)KGLWIN
GLOFA-GMGMWIN
XGB / XGT (XBC, XGK etc.)XG5000

Pièges courants

  1. XG5000 cannot recognize K7M-DR14UE. Use XBC series if new replacement required.
  2. Running KGLWIN on Win10/11: XP compatibility mode + exécuter en tant qu'administrateur.
  3. Échec de communication: Check USB-serial driver, COM port number, débit en bauds, RS232 wiring.

Supported Operating Systems for KGLWIN (for K7M K120S PLC)

Officially supported OS (per manual): Fenêtres 95, Fenêtres 98, Fenêtres 2000, Windows XP (32-peu)

✅ Practical field operation (not official native support, run via compatibility mode)

  1. Windows7 (32bit /64bit) : Most stable modern OS, preferred for industrial commissioning
  2. Windows10 (64peu) : Require XP compatibility mode + exécuter en tant qu'administrateur. USB-RS232 driver is the main issue. LTSC version performs better than home edition.
  3. Windows11 (64peu) : Operable but unstable, occasional crash & serial communication anomaly, not recommended for primary commissioning.

❌ Unsupported

Mac OS, Linux (no native release; can run via virtual machine with XP/Win7)

Windows ARM edition (Surface ARM laptops, abnormal execution)

Windows S mode

⚙️ Configuration Steps for Win10/11

  1. Right-click KGLWIN.exe → Properties → Compatibility
  2. Check: Run this program in compatibility mode for: Windows XP (Service Pack3)
  3. Check: Run this program as an administrator
  4. Disable antivirus/Defender real-time protection to avoid serial port driver interception
  5. Communication depends on USB to RS232 (CH340/PL2303). Industrial-grade serial converter is preferred.

💡 Practical Engineering Suggestion

Maintenance for legacy K120S (K7M-DR14UE): Prepare Win7 32-bit industrial PC, highest online success rate.

If only Win10/11 available: Install XP on virtual machine, pass-through USB serial adapter to VM; much more stable than running KGLWIN directly on host OS.

Full Model List for LS MASTER-K120S (K7M) Processeur

Description de la série:

UE = economical type (2K program steps, AC220V power). K7M-DR14UE belongs to this group

U = standard type (7K program steps, AC220V)

U/DC = standard type DC24V power supply

RD: Sortie relais; DT: NPN Transistor Output; DRT: Mixed Relay + Transistor Output

  1. UE Economical Series (AC220V, 2K étapes)
ModèleE/S totalesSaisirSortirType de sortie
K7M-DR10UE10 points6DEPUIS4FAIRERelais
K7M-DR14UE14 points8DEPUIS6FAIRERelais
K7M-DR20UE20 points12DEPUIS8FAIRERelais
K7M-DR30UE30 points18DEPUIS12FAIRERelais
  1. U Standard Series (AC220V,7K étapes)
ModèleE/S totalesSaisirSortirType de sortie
K7M-DR10U10 points6DEPUIS4FAIRERelais
K7M-DR14U14 points8DEPUIS6FAIRERelais
K7M-DT10U10 points6DEPUIS4FAIRETransistor NPN
K7M-DT14U14 points8DEPUIS6FAIRETransistor NPN
K7M-DR20U20 points12DEPUIS8FAIRERelais
K7M-DT20U20 points12DEPUIS8FAIRETransistor NPN
K7M-DRT20U20 points12DEPUIS8FAIRE4Relay+4Transistor
K7M-DR30U30 points18DEPUIS12FAIRERelais
K7M-DT30U30 points18DEPUIS12FAIRETransistor NPN
K7M-DRT30U30 points18DEPUIS12FAIRE8Relay+4Transistor
K7M-DR40U40 points24DEPUIS16FAIRERelais
K7M-DT40U40 points24DEPUIS16FAIRETransistor NPN
K7M-DRT40U40 points24DEPUIS16FAIRE12Relay+4Transistor
K7M-DR60U60 points36DEPUIS24FAIRERelais
K7M-DT60U60 points36DEPUIS24FAIRETransistor NPN
K7M-DRT60U60 points36DEPUIS24FAIRE20Relay+4Transistor
  1. U/DC Standard DC Power Series (DC24V power,7K étapes)

K7M-DR10U/DC, K7M-DR14U/DC, K7M-DT10U/DC, K7M-DT14U/DC

K7M-DR20U/DC, K7M-DT20U/DC, K7M-DRT20U/DC

K7M-DR30U/DC, K7M-DT30U/DC, K7M-DRT30U/DC

K7M-DR40U/DC, K7M-DT40U/DC, K7M-DRT40U/DC

K7M-DR60U/DC, K7M-DT60U/DC, K7M-DRT60U/DC

  1. Modèles spéciaux

K7M-EL60A: Elevation dedicated K120S CPU

  1. K120S Expansion Modules G7E Series (matched with above CPU)

Modules numériques

G7E-DR10A (6DI+4DO Relay), G7E-DR20A (12DI+8DO Relay)

G7E-TR10A (10-point transistor output), G7E-RY08A (8-point relay output)

G7E-DC08A (8-point DC input), G7E-DR08A (4DI+4DO Relay)

Modules analogiques

G7F-AD2A 2-channel AI; G7F-DA2I 2-channel AO; G7F-ADHB 4-channel high-speed AD

G7F-RD2A RTD PT100; G7F-TC2A Thermocouple module

Communication Special Modules

G7L-CUEB, G7L-CUEC C-net communication module

⚠️ Replacement Reminder

  1. UE economical model only has 2K program steps, cannot directly replace U standard model (7K). Download error occurs when program exceeds 2K steps.
  2. DR relay output cannot send pulse for positioning; DT transistor model for pulse output; DRT mixed model handles both switch signal & impulsion.
  3. All K120S (K7M) abandonné. Programming software is KGLWIN, XG5000 not supported.

Engineering Application Cases for K7M-DR14UE

Condition préalable: Pure digital logic, limited high-speed counting; relay output without high-frequency positioning pulse; program capacity limit 2K steps. Suitable for small standalone machines & legacy equipment retrofit.

Cas 1: Flameproof Distribution Switch Control for Underground Mining (Classic Real Project)

Affectation des E/S: 8DEPUIS: Surcharge, fuite, verrouillage de porte, arrêt d'urgence, bouton de test, retour d'état; 6FAIRE: Close command, trip command, alarme de panne, run indicator, test output

Architecture du système: K7M-DR14UE本体, RS485 upload signal to surface HMI/host, remote collection & alarm for switch status

Logique: Leakage lockout, overload time-delay trip, verrouillage de porte (closing prohibited with cabinet open), fault latch; high-speed counter for pulse current signal

Selection reason: AC wide voltage 85~264V, noise immunity input filter; built-in RS485, compact size for flameproof enclosure; relay output drives intermediate relay for main circuit

Limitation: Only protection logic, no complex calculation, short program well within 2K step limit

Cas 2: Small Belt Conveyor / Assembly Line Standalone Control

Affectation des E/S: DEPUIS: Start button, arrêt, arrêt d'urgence, belt deviation sensor, material level, block feedback; FAIRE: Main contactor, buzzer alarm, run lamp, fault lamp, belt cleaner solenoid valve

Processus: Sequential belt start/stop, delay start/stop, fault shutdown + audible & alarme visuelle, deviation protection, auto start/stop based on material level; manuel / auto mode switch

Accessoires en option: Touch screen via RS232/485 for fault code viewing; multi-conveyor 1:N interlock via RS485 network

Important: Relay output suitable for contactor coil; Do NOT drive high-power load directly with PLC relay, add intermediate relay for isolation.

Cas3: Auxiliary Packaging Machine (Discharging, Material stopper, Cylinder sequence action)

Usage: Small packaging auxiliary station, material stopper cylinder, material detection, compte, auto stop when bin full

DEPUIS: Photoelectric sensor, low material detection, cylinder position magnetic switch, start/reset; FAIRE: Solenoid valve, voyant lumineux, alarme

Processus: Material detected → stopper cylinder extend → discharge → delay retract, finished product counting, auto stop at full bin; high-speed counter for product count

Limitation: Cannot control servo/stepper positioning (DR relay no pulse output); replace with DT transistor version if positioning required.

Cas4: Small HVAC / Air Handling Unit (Fresh air unit, simple constant temperature cabinet logic)

DEPUIS: Differential pressure switch, freeze protection switch, fan overload, manual-auto selector; FAIRE: Contacteur de ventilateur, motorized damper, alarme

Solution: CPU only for digital interlock; external G7F-RD2A/TC2A analog module for PT100 / thermocouple temperature sampling if PID needed

Logique: Ventilateur & damper interlock, freeze protection, differential pressure alarm, fault shutdown; RS485 connect to building SCADA for remote monitoring

Cas5: LV Cabinet / Control Cabinet Logic Monitoring Unit (Switchgear status acquisition)

DEPUIS: Circuit breaker on/off feedback, spring charged status, cabinet door limit, fault signal; FAIRE: Close circuit, alarme de panne, voyant lumineux

Fonction: Switchgear status collection, fault latch, remote upload. Widely used in legacy cabinet retrofit project, low-cost replacement for old relay logic

Avantage: AC220V power supply taken directly from cabinet control circuit, no extra DC supply required.

Cas6: Simple Elevating Platform / Material Hoist (Safety interlock control)

DEPUIS: Upper/lower limit, ultimate limit, arrêt d'urgence, verrouillage de porte, manual button; FAIRE: Up contactor, down contactor, alarme

Processus: Limiter la protection, emergency stop latch, lifting prohibited with door open; electrical interlock to prevent simultaneous activation of up & down contactor

⚠️Safety Notice: Lifting equipment requires independent safety relay. PLC logic only acts as auxiliary control and cannot serve as sole safety circuit.

K7M-DR14UE Specific Pitfalls & Conseils de sélection

  1. 2K step limitation: Complex process, many comments, multi-sequence steps may exceed capacity and cause download failure. Use K7M-DR14U (7K standard version) for complex projects.
  2. Sortie relais: Not suitable for frequent switching; select DT transistor model for high-speed solenoid valves.
  3. Communication: RS485 Cnet protocol for HMI & SCADA; KGLWIN software, XG5000 incompatible.
  4. Expansion: Add G7E digital modules, G7F analog modules if insufficient I/O points.

Applications non recommandées

Servomoteur / stepper motor positioning (no pulse output)

High-frequency solenoid valves (fast contact wear)

Mass analog signal + heavy PID calculation (easy program overflow under 2K steps)

New greenfield projects (abandonné, LS XBC series preferred)

Précédent: