Mitsubishi HG-KN43J-S100 Servo Motor - Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

Mitsubishi HG-KN43J-S100 Servo Motor - Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur

API/

Mitsubishi HG-KN43J-S100 Servo Motor

Série: HG-KN (Low-inertia compact, for MR-JE drive) | Puissance nominale: 400W / 0.4kW | Non-brake standard type HG: Prefix for Mitsubishi AC servo motor KN: HG-KN low-inertia compact series (MR-JE platform) 43: 400W specification J: Shaft with keyway, no built-in brake S100: 17-codeur absolu à bits (131072 impulsions/tour, compatible with MR-JE) Brake-equipped variant in the same ...

  • Détails du produit

Série: HG-KN (Low-inertia compact, for MR-JE drive) | Puissance nominale: 400W / 0.4kW | Non-brake standard type

HG: Préfixe pour Mitsubishi Servomoteur à courant alternatif

KN: HG-KN low-inertia compact series (MR-JE platform)

43: 400W specification

J.: Shaft with keyway, no built-in brake

S100: 17-codeur absolu à bits (131072 impulsions/tour, compatible avec MR-JE)

Brake-equipped variant in the same series: HG-KN43BJ-S100 (B = frein électromagnétique)

✅ Key Electrical Specifications

Puissance nominale: 400 W

Couple nominal: 1.3 N·m

Maximum Torque: 3.8 N·m

Vitesse nominale: 3000 tr/min

Vitesse maximale: 5000 tr/min

Tension d'alimentation: AC200V (single/three-phase 200–240V)

Courant nominal: 2.6 UN

Encodeur: 17-un peu absolu

Taille de bride: 60×60 mm

Diamètre de l'arbre: φ19mm

Classe de protection: IP65 (standard oil seal fitted)

Poids: Environ. 1.8 kilos

✅ Compatible Drives (MR-JE only)

MR-JE-40A (Impulsion / analog interface)

MR-JE-40B (SSCNETⅢ/H bus)

MR-JE-40C (CC-Link IE Field)

✅ Applications typiques

Lignes de convoyage, linear transfer modules, machines à graver, machines d'emballage, small CNC, point-to-point positioning mechanisms. Suitable for applications requiring fast start-stop response with low inertia.

✅ Spare & Notes de remplacement

Not compatible with MR-J4 / MR-JN drives; exclusive to MR-JE series

Domestic alternative references: Delta B3 400W, Inovance IS620 400W low-inertia models

Câbles: Câble d'alimentation + encoder cable, dedicated MR-JE connector, not directly interchangeable with MR-J4

MR-JE Alarm Code List (for HG-KN43J-S100)

Deux catégories: AL.xx Fault Alarms (machine stop) and E□.x Warnings (no stop). AL alarms require power cycle or software reset; warnings normally clear automatically once root cause is removed.

  1. AL Fault Alarms (Couramment utilisé)
Code d'alarmeAlarm NameCause première & Dépannage
AL.10Sous-tensionLow main circuit voltage; perte de phase, poor contact of contactor, insufficient power supply capacity, câblage lâche
AL.12RAM Memory ErrorInternal drive hardware failure; power cycle first. Repeated alarm → replace drive
AL.14Control Circuit ErrorInternal CPU / control board failure; replace drive if restart ineffective
AL.16Encoder Initial Communication Error 1Loose CN2 encoder cable / connector, EMI interference, encoder damage
AL.1EEncoder Initial Communication Error 2Encoder handshake failure on power-up; check cable, mise à la terre du blindage, motor encoder
AL.1FEncoder Initial Communication Error 3Mismatched encoder version / modèle; HG-KN is dedicated for MR-JE, do not mix other motors
AL.20Encoder Communication Error 1Encoder wire break, poor contact or heavy EMI during operation
AL.21Encoder Communication Error 2Hardware failure of encoder
AL.25Absolute Position LostDead encoder battery or disconnected battery wire; homing required after reset (frequent alarm for S100 absolute encoder)
AL.24Main Circuit FaultShort circuit on U/V/W, motor earth leakage, failed power transistor
AL.30Regeneration FaultDécélération rapide, grande inertie de charge; insufficient built-in regenerative resistor, broken resistor, incorrect PA02 parameter
AL.31SurvitesseActual speed exceeds limit; excessive electronic gear ratio, abnormal pulse command, défaut d'encodeur
AL.32SurintensitéU/V/W short circuit, motor insulation breakdown, damaged drive IGBT
AL.33SurtensionDC bus voltage>400V; voltage rise by regenerative energy during deceleration, excessive input voltage
AL.35Command Pulse Frequency ErrorPulse frequency out of drive limit, wrong pulse wiring mode (différentiel / collecteur ouvert)
AL.36SSCNET Communication Error (JE-B)Lâche / sharply bent fiber optic cable, duplicated station number, bus interference
AL.37Erreur de paramètreParameter out of range or conflicting parameter combination; restore factory settings for test
AL.39Sequence Program Error (Position Table)Wrong position table instruction or conflicting parameters
AL.45Main Circuit OverheatPoor drive heat dissipation, température ambiante élevée, blocked cooling fan
AL.46Surchauffe du moteurSurcharge, continuous stall, frein non desserré, mauvaise dissipation de la chaleur
AL.47Cooling Fan FaultFan stuck or damaged
AL.50Position Excessive DeviationLarge gap between command and actual position; mechanical jam, couple insuffisant, low gain
AL.51Vibration DetectedServo vibration / bruit anormal; excessive gain, mechanical resonance
AL.61Forced Stop AlarmEmergency stop EMG circuit open (hardware E-stop, arrêt immédiat)
AL.86Network Communication Error (JE-C CC-Link IE)Faulty Ethernet cable, wrong IP, switch fault, bus disconnection
  1. E Warnings (No Shutdown, Display E□.x)
Warning CodeWarning NameDescription
E6.1Forced Stop WarningEMG terminal open warning (not a hard fault; often masked in projects – short EMG on CN1/CN3 or mask by parameter)
E8.1Homing IncompleteAbsolute encoder without homing after power-up; operation allowed but origin reference lost
E9.1Battery WarningLow encoder battery voltage. Replace battery promptly to avoid AL.25
E0.1Software Positive LimitLSP software limit triggered
E0.2Software Negative LimitLSN software limit triggered
  1. Reset Rules
  2. AL faults: Remove fault condition then power off & on to reset; some alarms can be cleared via MR Configurator2 software
  3. E warnings: Clear automatically after condition recovered, power cycle usually unnecessary
  4. AL.25: Home return must be executed after alarm clearing
  5. High-Failure Reminders for HG-KN43J-S100

AL.25, E9.1: Absolute encoder battery related – most frequent faults

AL.16/1E/1F/20/21: CN2 encoder cable. Separate power cable and encoder cable routing; single-end shield grounding

AL.46: 400W motor is prone to overheat under heavy load or continuous low-speed operation

Mitsubishi MELSERVO Servo List (Moteur + Correspondance des lecteurs, 200V Mainstream, including HG-KN / MR-JE)

General Suffix Definition

B: Frein électromagnétique; J.: Shaft with keyway; S100: 17-codeur absolu à bits; S000: Codeur incrémental

Drive suffix: A = Pulse / analogique; B = SSCNETⅢ/H fiber; C = CC-Link IE Field; G = CC-Link IE TSN (MR-J5)

⚠️ Series incompatibility: MR-JE motor cannot run on MR-J4/J5; MR-J4 motor cannot directly run on MR-J5

  1. MR-JE Economy Series (matches your HG-KN43J-S100, widely used cost-effective model)

Matched Motors: HG-KN (Low Inertia), HG-SN (Inertie moyenne)

MR-JE Drives

MR-JE-10A / 10B / 10C —— 0.1kW

MR-JE-20A / 20B / 20C —— 0.2kW

MR-JE-40A / 40B / 40C —— 0.4kW (for your motor)

MR-JE-60A / 60B / 60C —— 0.6kW

MR-JE-70A / 70B / 70C —— 0.75kW

MR-JE-100A / 100B / 100C —— 1.0kW

MR-JE-200A / 200B / 200C —— 2.0kW

MR-JE-300A / 300B / 300C —— 3.0kW

HG-KN Motors (Low Inertia, 3000tr/min)

HG-KN13J-S100 (0.1kW), HG-KN23J-S100 (0.2kW), HG-KN43J-S100 (0.4kW), HG-KN63J-S100 (0.6kW), HG-KN73J-S100 (0.75kW), HG-KN102J-S100 (1.0kW), HG-KN202J-S100 (2.0kW), HG-KN302J-S100 (3.0kW)

Version frein: HG-KN□□BJ-S100

HG-SN Motors (Inertie moyenne, for fluctuating loads)

HG-SN102J-S100 (1.0kW), HG-SN202J-S100 (2.0kW), HG-SN302J-S100 (3.0kW)

Version frein: HG-SN□□BJ-S100

  1. MR-J4 High-Performance Series (Large installed base for legacy machines)

Matched Motors: HG-KR, HG-MR, HG-SR, HG-RR, HG-JR

MR-J4 Drives

MR-J4-10A/B/GF — 0.1kW

MR-J4-20A/B/GF — 0.2kW

MR-J4-40A/B/GF — 0.4kW

MR-J4-60A/B/GF — 0.6kW

MR-J4-70A/B/GF — 0.75kW

MR-J4-100A/B/GF — 1.0kW

MR-J4-200A/B/GF — 2.0kW

MR-J4-350A/B/GF — 3.5kW

MR-J4-500A/B/GF — 5.0kW

MR-J4-700A/B/GF — 7.0kW

Multi-axis drives: MR-J4W2-22B, MR-J4W2-44B (2-axe); MR-J4W3-222B (3-axe)

MR-J4 Motor Lineup

  1. HG-KR: Small low-inertia 50W~750W (HG-KR053, HG-KR13, HG-KR23, HG-KR43, HG-KR73)
  2. HG-MR: Ultra-low inertia for frequent start-stop 50W~750W (HG-MR053,13,23,43,73)
  3. HG-SR: Medium inertia 0.5~7kW (HG-SR52,102,152,202,352,502,702)
  4. HG-RR: Medium capacity ultra-low inertia 1~5kW (HG-RR103,153,203,353,503)
  5. HG-JR: Large low-inertia 0.5~55kW (Mainly for machine tools, impression, moulage par injection)
  6. MR-J5 New Flagship Series (CC-Link IE TSN, new project replacement for MR-J4)

Matched Motors: HK-KT (Faible inertie, replace HG-KR/KN), HK-RT (Inertie moyenne, replace HG-SR)

MR-J5 Drives

MR-J5-10A/B/G — 0.1kW

MR-J5-20A/B/G — 0.2kW

MR-J5-40A/B/G — 0.4kW

MR-J5-60A/B/G — 0.6kW

MR-J5-70A/B/G — 0.75kW

MR-J5-100A/B/G — 1.0kW

MR-J5-200A/B/G — 2.0kW

MR-J5-350A/B/G — 3.5kW

MR-J5-500A/B/G — 5.0kW

MR-J5-700A/B/G — 7.0kW

Multi-axis drives: MR-J5W2-G, MR-J5W3-G (2-axe / 3-axe, wiring saving)

MR-J5 Motors

HK-KT Low Inertia: HK-KT053W,13W,23W,43W,73W

HK-RT Medium Inertia: HK-RT103W,153W,203W,353W,503W,703W

  1. Discontinued Legacy Series (Des pièces de rechange & maintenance only, not recommended for new projects)
  2. MR-J3 + HF-KP / HF-SP (Largest legacy stock, suppression progressive)
  3. MR-E / MR-ES + HF-KN / HF-SN (Earlier economy type, incompatible with HG-KN)
  4. MR-J2S (Very old generation)
  5. Tableau récapitulatif de sélection rapide
Drive SeriesPositionnementMoteur assortiInterface de bus
MR-JEÉconomie, rentableHG-KN / HG-SNImpulsion / SSCNETⅢ/H / CC-Link IE Field
MR-J4General high-performance (legacy stock)HG-KR/MR/SR/RR/JRImpulsion / SSCNETⅢ/H / CC-Link IE Field
MR-J5New flagship for new projectsHK-KT / HK-RTImpulsion / SSCNETⅢ/H / CC-Link IE TSN
  1. Notes complémentaires
  2. 400V high-voltage versions: MR-J4(-4), MR-J5(-4), with corresponding high-voltage motors, generally used above 7kW
  3. Special types: LM linear motors, TM-RG/TM-RU torque direct-drive motors, selected separately
  4. Cable incompatibility: MR-JE, MR-J4, MR-J5 encoder connectors & pin assignments differ and cannot be swapped directly

Précédent:

Laisser une réponse

Laisser un message