Phoenix Contact PTTB 2 Bornier Rail DIN - Contacteur,disjoncteur,onduleur solaire,compteur électrique,capteur,Encodeur,API

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

 Phoenix Contact PTTB 2 Bornier Rail DIN - Contacteur,disjoncteur,onduleur solaire,compteur électrique,capteur,Encodeur,API

électrique/

Phoenix Contact PTTB 2 Bornier Rail DIN

Phoenix Contact DoubleLevel Pushin DINRail Terminal Block, Numéro de commande: 3210567 Basic Information Series: PTTB 2.5 (CLIPLINE complete PT Pushin Series) Taper: Doublelevel feedthrough terminal block, 2 independent potentials, 4 points de connexion (2 per level) Connection Technology: Pushin toolfree connection. Solid conductors or stranded conductors with wire ferrules can be inserted directly. For bare stranded conductors, ...

  • Détails du produit

Contact Phénix DoubleLevel Pushin DINRail Bornier, Numéro de commande: 3210567

Informations de base

Série: PTTB 2.5 (CLIPLINE complete PT Pushin Series)

Taper: Doublelevel feedthrough terminal block, 2 independent potentials, 4 points de connexion (2 per level)

Connection Technology: Pushin toolfree connection. Solid conductors or stranded conductors with wire ferrules can be inserted directly. For bare stranded conductors, press the orange actuator lever before inserting wires.

Montage: DIN rail NS35/7.5, NS35/15

Largeur: 5.2 mm, grey; Insulation material PA, UL94V0 flame retardant

Wire stripping length: 810 mm

Spécifications électriques

ParamètreValeur
Rated voltage Un500 V
Courant nominal In22 UN (2.5 mm²)
Max.. permissible current26 UN (4 mm² solid conductor)
Conductor cross‑section0.14‑4 mm² / AWG26‑12
Tension assignée de tenue aux chocs6 kV, Over‑voltage Category III, Degré de pollution3
Température de fonctionnement-60℃ ~ +110℃

Principales fonctionnalités

  1. Doublelevel independent circuits. Two signal/power circuits within one 5.2 mmwide unit, économiser de l'espace dans l'armoire. Frontside wiring for easy operation in confined cabinet spaces.
  2. Builtin test jacks: test ports in doublefunction shaft plus extra external test connection. Multimeter probes can be applied without disconnecting wiring.
  3. Certifications: UL, cULus, VDE, ATEX/IECEx for hazardous areas, DIN EN 455452 for railway, DNV marine certification. Suitable for railway equipment, machinerie, process automation and explosive hazardous areas.
  4. Part of CLIPLINE complete system, compatible with system jumpers, marker strips and end partitions.

Commercial Data

Numéro de commande: 3210567

Emballage standard: 50 pcs per pack

Poids unitaire: environ. 11 g

Domestic Equivalent Reference

Caractéristiques: 5.2 mm doublelevel pushin terminal block, 2 electricallyisolated potentials, 0.144 mm², 22 UN, DINrail mount

Innovation: ITB2.52D

Weidmüller: A2T 2.5

DINKLE: DK2.52P

Note: Lors du remplacement, verify currentcarrying capacity, stripping length, jumper compatibility and certifications for explosionproof / railway projects.

PTTB 2,53210567

Numéro de commande: 3210567|Product: Doublelevel electricallyisolated pushin DINrail terminal block|CLIPLINE complete PT Pushin series

  1. Spécifications mécaniques
ArticleSpécification
Levels / Connection points2 niveaux, 4 bornes, full electrical isolation between upper and lower levels
Rail compatibilityNS35‑7.5 / NS35‑15 standard DIN rail
Unit width5.2 mm
Matériau isolantPA polyamide, UL94‑V0 flame rating
Longueur de dénudage8‑10 mm
Poids unitaire≈11 g
Méthode de connexionPush‑in connection; direct insertion for solid conductors / stranded conductors with ferrules; press orange actuator lever for bare stranded conductors
Conductor range0.14‑4 mm², AWG26‑12
Pack quantity50 pcs
  1. Spécifications électriques (IEC 6094771)
ArticleValeur
Rated voltage Un500 V CA
Courant nominal In22 UN (2.5 mm²)
Max.. permissible current26 UN (4 mm² solid conductor)
Tension assignée de tenue aux chocs6 kV, Over‑voltage Category III, Degré de pollution3
Température de fonctionnement-60℃ ~ +110℃ (operational)
Touch‑safe protectionFinger‑ and back‑of‑hand safe protection per DIN EN 50274
  1. Builtin Functions & Compatibilité des accessoires
  2. Dual test points: test ports in doublefunction shaft plus separate external test jacks. Multimeter probes can measure signals without wire disassembly.
  3. Compatibilité du système: fully interoperable with CLIPLINE complete system accessories: jumpers, end partitions, ZB marker strips, separator partitions.
  4. Certifications: UL/cULus, VDE, IECEx, DIN EN455452 railway, DNV marine, RoHS.
  5. Applications typiques: cabinet I/O signal wiring, distribution d'énergie, railway equipment, process automation hazardousarea cabinets, marine equipment.
  6. Comparaison: PTTB 2.5 (3210567) vs PT2.5TWIN

Frequently confused doublelevel pushin terminal blocks

Article de comparaisonPTTB 2.5 (3210567)PT 2.5‑TWIN (3211062)
Potential relationFully‑isolated two independent circuitsSupérieur & lower levels internally connected, single potential (1‑to‑2 branching)
Connection terminals4 independent terminals4 bornes, upper‑lower levels electrically connected
Application purposeTwo isolated signals / two independent power circuitsOne input branched to two outputs
Largeur5.2 mm5.2 mm
Notation22 A /500 V22 A /500 V

⚠️Selection Pitfall: Using TWIN (commonpotential) to substitute PTTB (isolated doublelevel) will result in shortcircuit upon poweron. Always verify potential relationship in projects.

  1. Selection Notes for Domestic Replacements

Reference models: Inovance ITB2.52D; Weidmüller A2T2.5; DINKLE DK2.52P

Mandatory confirmation: doublelevel electrical isolation, NOT TWIN commonpotential type

Vérifier: conductor range 0.144 mm², 22 A rating, 5.2 mm width, test jacks, leveractuated operating structure

For railway / explosionproof projects: domestic substitutes must satisfy corresponding certification requirements; mechanical dimension match alone is not sufficient.

  1. Installation & Directives d'entretien
  2. Do NOT forceinsert bare stranded conductors without ferrules. Always depress the orange lever before inserting bare flexible wires, otherwise internal spring damage and excessive contact resistance with overheating risk may occur.
  3. Jumpers shall only be applied within the same level. Crosslevel jumpering is prohibited; use dedicated jump wires for crosslevel connections.
  4. Use standard 2.3 mm multimeter probes. Oversized probes may damage test jacks.

Application Scenarios of PTTB 2,53210567 (Doublelevel Isolated Pushin Terminal Block)

Core characteristics: 5.2 mm width, electricallyisolated two independent circuits, 4 points de connexion, Pushin toolfree wiring, builtin test jacks; 22 UN / 500 V; certified for railway, ATEX/IECEx hazardousarea, marine DNV applications.

⚠️Reminder: It is NOT a TWIN commonpotential terminal. Upper and lower levels are electrically separated for two independent circuits, NOT for 1to2 branching.

  1. Industrial Automation Control Cabinet (Most Common Use)
  2. PLC I/O Signal Circuits

One single terminal block handles two DI/DO signals to save DINrail space. Upper level connects to PLC side; lower level connects to field sensors / actionneurs. Builtin test jacks allow multimeter measurement without disconnection during commissioning. Ideal for highdensity wiring in robot, conditionnement, injectionmolding and machinetool cabinets.

  1. Two independent control power distribution

Within one unit: one channel for 24 V control power, the other for isolated signal power, preventing interference between different power circuits. Used for smallsize solenoid valves and indicator light loops.

  1. Isolated inputoutput transfer

Two fullyisolated circuits for internal cabinet signal transfer, where signal grounds must be separated.

  1. RollingStock & Railway Vehicles (Certificationcritical Application)

Qualified with DIN EN455452 railway fireprotection and EN50155 vibrationshock standards. Large température de fonctionnement 60 ~ +110 ℃, haute résistance aux vibrations.

  1. Onboard cabinet: door control, airconditioning, éclairage, passengerinformation systems. Compact cabinet requires highdensity wiring.
  2. Locomotive / EMU control panels: transfer of two isolated signals and power circuits. Springclamp connection avoids screwloosening under vibration.

Prefer original Phoenix unit for railway projects. Domestic alternatives must pass firesafety and vibration certifications; mechanical dimension matching is insufficient.

  1. Industrie de transformation / HazardousArea Cabinets (ATEX/IECEx)
  2. Chemical and pharmaceutical explosionproof cabinets: isolated transfer for intrinsicallysafe and nonintrinsicallysafe signals. Doublelevel isolation prevents crosscircuit interference, complying with hazardousarea wiring requirements.
  3. Transmitter signal wiring: one channel for 420 mA analog signal, the other for isolated alarm loop. Saves cabinet installation space.
  4. Marin & Offshore Equipment (DNV Marine Approval)

Control cabinets on vessels and deck enclosures. Vibrationresistant, widetemperature, humiditytolerant. Used for two independent signal / power circuit transfer.

  1. Autres applications industrielles
  2. Automatisation des bâtiments / HVAC Control Cabinets: DDC controller wiring for two independent sensor signals (température, humidité). Optimized for compact smallsize cabinets.
  3. NewEnergy Equipment (Energystorage, smallscale PV cabinets): Lowvoltage controlloop wiring for isolated 24 V signal channels.
  4. Testbenches & équipement de laboratoire: Two independent test circuits with convenient probeaccess test jacks to improve commissioning efficiency.

✅ Typical Correct Wiring Examples

  1. Upper level: Circuit A (24V+ /24V); Lower level: Circuit B (separate isolated 24V+ /24V), circuits fully independent.
  2. Upper level: DI input signal; Lower level: DO output signal, isolated signal transfer.

❌ Forbidden Practices

  1. Do NOT use as PT2.5TWIN (commonpotential 1to2 splitter). PTTB upperlower levels are insulated with no internal continuity. For oneinputtwooutput branching, select Order No. 3211062.
  2. Crosslevel jumpers are prohibited. Jumpers can only connect terminals on the same level.

Guide de sélection

Choose PTTB2.53210567: Two circuits require full electrical isolation.

Choose PT 2.5TWIN3211062: One signal to be branched into two outputs, upperlower levels internally connected.

Précédent:

Laisser une réponse

Laisser un message