Phoenix MCR-C-UI-UI-DCI-2810913

Model Code Breakdown Explanation Code Segment Definition MCR Base series identifier: Modular Current/Voltage Converter, series of 3-way isolated signal conditioners C Dimension specification: Standard width (17.5mm), differs from MINI MCR series (6.2mm/12.5mm) UI Input type: Universal Input, supports 0–10V voltage & 4–20mA current signals UI Output type: Universal Output, supports 0–10V voltage & 4–20mA current ...

  • Détails du produit
  1. Model Code Breakdown Explanation
Segment de codeDéfinition
MCRBase series identifier: Modular Current/Voltage Converter, series of 3-way isolated signal conditioners
CDimension specification: Standard width (17.5mm), differs from MINI MCR series (6.2mm/12.5mm)
UIInput type: Universal Input, supports 0–10V voltage & 4–20mA current signals
UIOutput type: Universal Output, supports 0–10V voltage & 4–20mA current signals
DCIFunctional feature: DC Isolation; built-in DC/DC converter realizes 3-port isolation among Input / Sortir / Alimentation
2810913Unique order number: Officiel Phoenix part number for procurement & inventory management
  1. Core Specification Data Sheet

2.1 Basic Electrical Specifications

ParamètreValeurRemark
Isolation Type3-way isolation (Saisir / Sortir / Pouvoir)Withstand voltage test: In-Out:1.5kV AC; Power-Signal:1kV AC (50Hz, 60s)
Input Signal0–10V DC / 4–20mA DCMax.. input:30V / 50mA
Signal de sortie0–10V DC / 4–20mA DCMax.. sortir:15V / 30mA
Transmission Error≤0.1% FSHigh-precision signal conversion
Alimentation18–30V DCNominal 24V DC; No-load current <30mA
Consommation d'énergie≤900mWUnder rated operating condition
Cut-off Frequency30Hz3dB point, effectively suppress high-frequency interference
Step Response11MS (10%–90%)Fast signal tracking performance

2.2 Mécanique & Spécifications environnementales

ParamètreValeurRemark
Dimension globaleW17.5mm × H99mm × D114.5mmDIN rail mounting for space saving
MontageRail DIN standard de 35 mmArbitrary installation orientation available
TerminationPlug-in screw terminal (COMBICON)Longueur de dénudage:8mm, M3 screw thread
Cable SizeSolid/Flexible:0.2–2.5mm² (AWG24–14)Compatible with various industrial cables
Température de fonctionnement.-20°C ~ +65°CWide temperature range for industrial environment
Ingress RatingIP20Indoor cabinet installation only
Poids149.4g (with package)Lightweight for easy mounting

2.3 Attestation & Conformité

AttestationStandardRemark
CEDANS 61000-6-2 / DANS 61000-6-4EMC compliant
UL RecognizedUL 508Class I Div.2 Groups A-D; Class I Zone2 Group IIC
Eco-certificateEU RoHS / China RoHSEFUP-50 (50-year service life for environmental compliance)
HS Code85437090For customs clearance in international trade
  1. Full Series Part Number List (MCR-C-UI-UI-DCI Family)
Numéro de commande.ModèleCaractéristique spécialeApplication typique
2810913MCR-C-UI-UI-DCIVersion standard, factory preset 0–10V/0–10VGeneral industrial signal isolation & conversion
2810939MCR-C-UI-UI-DCI-NCNC = No CalibrationFixed application without on-site calibration
2811284MACX MCR-UI-UIUpgraded replacement modelNew generation with improved performance
2810915MCR-C-UI-UI-450-DCIHigh-load type, Max.. output load ≤450ΩLong-distance signal transmission & high-load occasions
2810941MCR-C-UI-UI-450-DCI-NCHigh-load without calibrationHigh-load fixed installation without trimming
  1. Cross-reference: Obsolete & Competitor Replacement List

4.1 Internal Phoenix Replacement

Ancien modèleModèle de remplacementPoints forts de la mise à niveau
MCR-C-UI-UI-DCI (2810913)MACX MCR-UI-UI (2811284)Narrower width(12.5mm), lower power draw, réponse plus rapide
MCR-C-UI-UI-450-DCIMACX MCR-UI-UI-450Identical function with compact footprint

4.2 Cross-brand Equivalent Comparison

Phoenix ModelSchneider EquivalentSiemens EquivalentDifférences fondamentales
MCR-C-UI-UI-DCI (2810913)FOXboro IMT25SITRANS P DS IIIPhoenix:3-way isolation,1.5kV withstand, rentable
1kV isolation,15ms response1.2kV isolation,12ms response
  1. Environnement d'application & Cas industriels

5.1 Applications recommandées

  1. Automatisation industrielle: Signal isolation between PLC and field sensors/actuators to eliminate ground loop interference
  2. Process Industry: Safe transmission of analog signals for chemical, pharmaceutique, nourriture & beverage in explosion-proof environment
  3. Nouvelle énergie: Pitch control monitoring for wind turbine, PV inverter signal acquisition, substation remote signaling renovation
  4. Transport ferroviaire: Signal isolation for train control & on-board equipment with superior EMC resistance
  5. Traitement de l'eau: PLC automation system for municipal water plant, safe integration of process sensor signals

5.2 Applications non recommandées

  1. Intrinsically Safe hazardous area (Select MCR-EX intrinsic safety series instead)
  2. Ultra-low temp (<-20°C) or ultra-high temp (>+65°C) environnement
  3. Special project requiring isolation voltage higher than 1.5kV
  4. High-frequency signal processing above 30Hz bandwidth

5.3 Cas d'application typiques

Cas 1: Automotive Production Line

Application: Signal isolation for welding robot controller & pressure transmitter

Issue: Severe EMI from welding current causes distorted sensor readings

Solution: Install MCR-C-UI-UI-DCI isolator, 1.5kV galvanic isolation, conversion error<0.1% to guarantee precise pressure control

Cas 2: Municipal Wastewater Treatment Plant

Application: Conversion & isolation between pH sensor and PLC analog input

Issue: Different equipment ground potential drift leads to unstable output

Solution: Adopt 3-port isolation to cut ground loop; convert 0–10V sensor signal to standard 4–20mA for up to 1000m long-distance cabling

  1. Conseils de sélection & Règles de référence rapide

Règles de sélection rapide

  1. Identification du modèle: MCR-C=standard size; UI=universal I/O; DCI=DC galvanic isolation
  2. Spécifications clés: 3-way isolation @1.5kV, 0–10V/4–20mA, 0.1%FS accuracy,11ms step response
  3. Option de mise à niveau: Compact space saving → MACX MCR series PN:2811284
  4. Application Rule: Ground loop trouble →3-port isolation; long cable run →4–20mA output
  5. Conformité des expéditions aériennes & CE Certification Summary

7.1 Conformité du transport aérien

Lithium Battery Check: No built-in lithium cell, classified as non-restricted goods without special shipping marking

Transport Classification: Complies with IATA DGR Class9, acceptable as general cargo

Emballage: Original factory carton preferred; ESD bag protection recommended

7.2 CE Certification Info

Normes applicables: EN61000-6-2 (Immunité), EN61000-6-4 (Émission)

DOC Download: EU Declaration of Conformity available on Phoenix official website (Doc No.:083097087_04_DoC_EU.pdf)

Valid Scope: All EU member states & regions accepting CE marking

  1. Guide de dépannage
Symptôme de panneRoot CauseRemède
Power LED off1. Missing power or reverse polarity1. Rewire DC supply with correct polarity
2. Supply out of 18–30V range2. Measure & adjust input to rated 24V DC
No output variation1. Improper input wiring1. Verify input wiring & signal type
2. Wrong DIP switch setting2. Reconfigure DIP switches
3. Load out of specification3. Voltage output ≥10kΩ; Current output ≤500Ω
Fluctuating output1. Input signal interfered1. Single-point grounding for shield cable
2. Excessive power supply ripple2. Add power filter
3. Poor module earthing3. Secure module chassis ground
Excessive conversion error1. Zero/Span drift1. Re-trim Zero & Span (±2% adjustable)
2. Ambient temp out of rated range2. Improve cabinet ventilation
3. Mismatched load impedance3. Adjust load to specified range

Phoenix MCR‑C‑UI‑UI‑DCI (2810913) On-site Installation Manual

  1. Safety Precaution (Mandatory Reading)

Classe de protection: IP20, indoor dry cabinet installation only

Tension de tenue: In-Out 1.5kV AC/60s; Power-Signal 1kV AC/60s, overvoltage withstand test prohibited

Protection ESD: Static-sensitive component; discharge body static by touching grounded metal before handling

Hazardous Area: Suitable for Zone2 / Class I Div.2 only; MCR‑EX IS series for Intrinsically Safe location

Alimentation:18–30V DC (Nominal 24V DC); reverse polarity will permanently damage unit, confirm polarity prior to power-up

  1. Déballage & Inspection

2.1 Liste de colisage

Isolation amplifier MCR‑C‑UI‑UI‑DCI (2810913) ×1

This installation manual ×1

Factory test certificate ×1

2.2 Visual Check

No housing crack, intact snap latch, non-deformed & rust-free terminals

Confirm model & part No.: MCR‑C‑UI‑UI‑DCI / 2810913

  1. Environnement d'installation & Clearance Requirement

3.1 Conditions ambiantes

Température de fonctionnement: -20°C ~ +65°C

Température de stockage: -25°C ~ +70°C

Humidité:10%~90% non-condensing

Min.30cm clearance away from strong EMI source (VFD, large motor, transformateur)

3.2 Mounting Spacing

Monter: Rail DIN standard de 35 mm (EN60715), any mounting direction allowed

Side gap between adjacent modules ≥5mm

Vertical top/bottom clearance ≥20mm for heat dissipation & entretien

Install at upper/middle cabinet position; avoid dusty bottom compartment

  1. Montage sur rail DIN & Dismount Steps

4.1 Montage

  1. Clean DIN rail from grease & burr, ensure reliable rail grounding
  2. Flip upward the orange top latch of module
  3. Hook upper notch onto top edge of DIN rail then press down module bottom
  4. Audible click sound confirms locked & fixed without wobble

4.2 Dismounting

  1. Cut off module power & all field signals first; no live removal allowed
  2. Lift orange release latch upward
  3. Lift module bottom upward to detach from DIN rail then take out
  4. Définition du terminal & Spécification de câblage

5.1 Terminal Pinout (Left to Right)

Numéro de broche.MarquageDéfinitionNote
1.1IN UVoltage Input (0–10V)Signal Positive
1.2IN ICurrent Input (4–20mA)Signal Positive
1.3GND 1Input CommonSignal Negative
2.1OUT UVoltage Output (0–10V)Signal Positive
2.2OUT ICurrent Output (4–20mA)Signal Positive
2.3GND 2Output CommonSignal Negative
3.124À DCPuissance positive18–30V DC
3.2GNDPouvoir négatifSupply Ground

5.2 Wiring Standard

Cable strip length:8mm (too long → short circuit; too short → poor contact)

Taille du conducteur: Solid/Flexible 0.2–2.5mm² (AWG24–14); ferrules required for stranded flexible wire

Screw torque:0.5~0.6N·m for M3 terminal, avoid over-tightening thread slip

Shield cable: Single-end cabinet grounding (transmitter end floating) to eliminate ground loop

5.3 Typical Wiring Examples

Ex1: 4–20mA Input →4–20mA Output (2-wire transmitter)

Émetteur + →1.2(IN I)

Transmitter − →1.3(GND1)

2.2(OUT I) →PLC AI+

2.3(GND2) →PLC AI−

3.1→24V DC+;3.2→24V DC−

Ex2:0–10V Input→0–10V Output (Voltage sensor)

Sensor +→1.1(IN U)

Sensor −→1.3(GND1)

2.1(OUT U)→PLC AI+

2.3(GND2)→PLC AI−

3.1→24V DC+;3.2→24V DC−

  1. DIP Switch Configuration (Factory preset for 2810913:0–10V/0–10V)

6.1 Switch Location (Side housing; remove cover to access)

S1: Input Configuration

S1‑1:OFF=0–10V; ON=4–20mA

S1‑2:OFF=Unipolar; ON=Bipolar(±5V/±10V)

S2: Output Configuration

S2‑1:OFF=0–10V; ON=4–20mA

S2‑2:OFF=Unipolar; ON=Bipolar(±5V/±10V)

6.2 Factory Default (2810913)

S1:OFF/OFF (Unipolar 0–10V Input)

S2:OFF/OFF (Unipolar 0–10V Output)

6.3 Setting Procedure

  1. Cut off power supply then remove 2 cross-head screws to open cover
  2. Toggle DIP switches as required with fully seated position
  3. Refit housing & tighten screws before power-on test
  4. Power-up & Mise en service

7.1 Pre-power Inspection (Mandatory)

Full wiring check: No cross-connection, short circuit or loose terminal

DC supply test: 24V DC ±10% measured across pin3.1 &3.2

Isolation test: No continuity between Input/Output/Power with multimeter continuity mode

7.2 Indication d'état LED

PWR(Vert): Steady ON=Normal Supply; OFF=Power fault/reverse polarity

RUN(Vert): Blinking=Running normally; Solid/OFF=Module malfunction

7.3 Étalonnage (Optional for high precision requirement)

Zero Adjustment: Feed zero input signal, trim ZERO potentiometer for zero output

Span Adjustment: Feed full-scale input, trim SPAN potentiometer for full-scale output

Précision: ≤0.1%FS, max temperature drift ≤±2%

  1. On-site Quick Troubleshooting

8.1 Power LED Dark

Cause: Reverse polarity, abnormal voltage, câblage lâche | Action: Correct polarity, measure voltage, retighten terminals

8.2 Signal de sortie zéro

Cause: Mauvais câblage, mismatched DIP setting, surcharge | Action: Rewire, reset switches, check load impedance

8.3 Unstable Swinging Output

Cause: Improper shield grounding, high supply ripple, nearby EMI | Action: Single-point ground, install power filter, relocate away from interference source

8.4 Out-of-spec Accuracy

Cause: Thermal drift, zero/span shift, mismatched load | Action: Recalibrate, improve ventilation, adjust load

  1. Entretien périodique

Every 6-month routine: Power off to clean terminal/housing, recheck screw torque & recalibrate accuracy

Forbidden operation: Hot plug/unplug, overvoltage/overtemperature running, unauthorized internal circuit disassembly

  1. Assistance technique & Alternative Part

Manufacturer Support: Phoenix Contact China

Remplacement de mise à niveau: MACX MCR‑UI‑UI (2811284):12.5mm largeur, consommation d'énergie réduite, faster response speed