Schneider ATV310HU75N4E Variable Frequency Drive - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

Schneider ATV310HU75N4E Variable Frequency Drive - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

électrique/

Schneider ATV310HU75N4E Variable Frequency Drive

Model Code Definition Code Segment Description ATV Base series code: Altivar Variable Speed Drive, Schneider’s VFD product line 310 Series designation: Economy Altivar 310 série, cost-effective drives for general industrial applications H Load rating: Robuste, designed for continuous heavy-load operation with higher rated output current U75 Power rating: 7.5 kW (10 HP), matched for ...

  • Détails du produit

Définition du code modèle

Segment de codeDescription
VTTBase series code: Altivar Variable Speed Drive, Schneider’s VFD product line
310Series designation: Economy Altivar 310 série, cost-effective drives for general industrial applications
HLoad rating: Robuste, designed for continuous heavy-load operation with higher rated output current
U75Puissance nominale: 7.5 kW (10 HP), matched for 7.5kW three-phase asynchronous motors
N4Power supply specification: 3-phase 380–460 V AC, 50/60 Hz; permissible voltage variation: -15% ~ +10%
EConfiguration option: Standard version without built-in EMC filter; models with integrated filter end with suffix A
  1. Spécifications techniques de base

2.1 Spécifications électriques

ArticleValeurRemark
Puissance nominale7.5kW(10HP) Robuste / 11kW(15HP) Service normalDual rating design for diverse working conditions
Tension d'entrée nominale3-phase 380–460 V ACOperating range:323–528 V AC
Courant de sortie nominal17 UN (HD) / 24 UN (ND)Full rating up to 55°C; 2.2% derating per °C above 55°C up to 60°C
Plage de fréquence de sortie0.1~500 HzMinimum 0.1Hz under sensorless vector control
Mode de contrôleContrôle vectoriel sans capteur / Contrôle V/FAutomatic torque boost for various asynchronous motors
Instant Overload Torque170~200% of rated torqueSustain for 2 seconds for shock load applications
Unité de freinage intégréeStandard equippedPre-installed on models ≥7.5kW for fast braking requirements
Communication PortRS485 (Modbus RTU)RJ45 terminal on front panel for remote monitoring
Classe de protectionIP20Cabinet indoor mounting only

2.2 Mécanique & Spécifications environnementales

ArticleValeurRemark
Dimension globale(L×H×P)210×380×170 mmCompact footprint to save cabinet space
Type de montageWall / Panel mountingVertical installation to secure unobstructed cooling airflow
Température de fonctionnement-10℃ ~ +55℃ (full rating)2.2% power derating per ℃ between 55℃~60℃
Température de stockage-25℃ ~ +70℃Keep away from damp and corrosive gas atmosphere
Ambient Humidity5%~95 % (sans condensation)Dehumidifier recommended inside control cabinet
Méthode de refroidissementForced air cooling with built-in fanFan with thermal protection and auto fault alarm
Poids netApprox.7.8 kgEasy transportation and field installation

2.3 Attestation & Conformité

AttestationNorme applicableRemark
CEDANS 61800-5-1 / DANS 61000-6-2/4Sécurité & EMC compliance standard
UL RecognizedUL 508CNorth American standard for industrial control equipment
Eco ComplianceEU RoHS / China RoHSRestriction des substances dangereuses
HS Customs Code85044099Used for customs clearance in international trade
  1. Full Heavy-Duty Model List of ATV310 Series
Numéro de pièce.Description du modèlePuissance nominaleCaractéristique spécialeApplication typique
ATV310HU75N4E7.5kW Usage intensif7.5kW /10HPWithout built-in EMC filterGeneral industrial fans & pompes
ATV310HU75N4A7.5kW Usage intensif7.5kW /10HPWith built-in EMC filterSites with strict EMC requirements
ATV310H037N4E0.37kW Usage intensif0.37kW /0.5HPSans filtre CEMPetites machines, bandes transporteuses
ATV310H075N4E0.75kW Usage intensif0.75kW /1HPSans filtre CEMMini fans & pompes à eau
ATV310H15N4E1.5kW Usage intensif1.5kW /2HPSans filtre CEMConditionnement & machines textiles
ATV310H22N4E2.2kW Usage intensif2.2kW /3HPSans filtre CEMMatériel de manutention, compresseurs
ATV310H30N4E3.0kW Usage intensif3.0kW /4HPSans filtre CEMAgitators, petites pompes à eau
ATV310H40N4E4.0kW Usage intensif4.0kW /5.5HPSans filtre CEMTours de refroidissement, ventilation systems
ATV310H55N4E5.5kW Usage intensif5.5kW /7.5HPSans filtre CEMMedium-sized fans & process pumps
ATV310HD11N4E11kW Usage intensif11kW /15HPSans filtre CEMLarge compressors, industrial pumps
  1. Cross Reference: Internal Upgrade & Équivalent concurrent

4.1 Remplacement interne Schneider

Modèle obsolèteModèle de remplacementUpgrade Advantages
ATV303HU75N4ATV310HU75N4E/AWider operating temp (-10~55℃), unité de freinage intégrée, anti-corrosion coating, more compact dimension
ATV310HU75N4EATV310HU75N4AAdd integrated EMC filter to satisfy stricter EMC regulations

4.2 Cross-brand Alternative Comparison

Modèle SchneiderSiemens EquivalentABB EquivalentKey Differentiation
ATV310HU75N4EMM440-7.5kWACS510-7.5kWSchneider: Dual power rating, full capacity @55℃, built-in brake unit, cost competitive
150% overload for 3s160% overload for 1minSiemens: Higher vector control precision; ABB: Richer communication options
  1. Champ d'application & Industrial Cases

5.1 Applications recommandées

  1. Industrial Pumps & Ventilateurs: Systèmes CVC, raw & wastewater treatment plants; 30~50% energy saving achievable
  2. Manutention des matériaux: Convoyeurs, palans, cranes for smooth soft start and variable speed regulation
  3. Textile Equipment: Bobineuses, looms, impression & dyeing machines for constant tension control
  4. Machines d'emballage: Remplissage, labeling and sealing equipment to boost production efficiency & product quality
  5. Compresseurs: Air & compresseurs de réfrigération; soft start reduces grid surge and extends motor service life
  6. Équipement de mélange: Chemical reactors & food blenders for mixing of fluids with variable viscosity

5.2 Applications non recommandées

  1. Precision speed control for synchronous motors: Select ATV340 series with encoder-feedback vector drive
  2. High altitude installation (>1000m): Mandatory power derating by 1% per additional 100m elevation
  3. Corrosive gas environment: Add external anti-corrosion enclosure or specify ATV320 anti-corrosion variant
  4. IP rating higher than IP20: Choose ATV320 IP54 protected models

5.3 Cas d'application typiques

Case1: Aeration System for Municipal Wastewater Plant

Application: Variable speed control of 7.5kW submersible aerator based on real-time dissolved oxygen value

Original Issue: Direct-on-line start leads to short motor lifespan, high power consumption and severe grid disturbance

Solution: Install ATV310HU75N4E for soft start; 40% power saving, double motor service life and reduced maintenance cost

Case2: Textile Spool Winding Machine

Application: Constant tension control for uniform yarn winding

Original Issue: Big tension fluctuation causes high yarn breakage rate and unstable finished quality

Solution: Adopt sensorless vector control to adjust output torque dynamically; tension tolerance controlled within ±5% and 15% improvement on finished product yield

  1. Lignes directrices de sélection & Règles de référence rapide

Règles de sélection rapide

  1. Code Identification: ATV310=core series; H=Heavy Duty; U75=7.5kW; N4=3-phase 380V; E=No EMC filter
  2. Key Specs Recap: 17Un courant nominal, 170~200% overload torque, integrated brake unit, Modbus RTU communication
  3. Option de mise à niveau: Suffix A = built-in EMC filter; high-performance demand → ATV340 series
  4. Application Rule: Continuous heavy load → H version; light load → D version; strict EMC → A suffix model
  5. Air Shipment & CE Compliance Specification

7.1 Air Transport Regulation

Lithium Battery Check: No built-in lithium cells, classified as non-restricted cargo without special air shipping marks

Shipping Standard: Complies with IATA DGR Class9, allowed for general cargo transportation

Emballage: Original factory carton preferred; anti-shock foam padding recommended to avoid transit damage

7.2 CE Certification Details

Applied Standards: DANS 61800-5-1(Sécurité), DANS 61000-6-2(Immunité), DANS 61000-6-4(Émission)

DOC Download: EU Declaration of Conformity available on Schneider official website (Doc No.:ATV310_CE_DOC.pdf)

Valid Territory: All EU member states and regions recognizing CE marking

  1. On-site Troubleshooting Guide
Code d'erreur & DescriptionRoot CauseCorrective Action
CF Overcurrent Fault1. Motor winding short or earth fault1. Insulate motor cable & winding
2. Too short acceleration ramp2. Extend acceleration time (Paramètre 202)
3. Excessive mechanical overload3. Reduce load or upgrade to higher power drive
OH Overheat Fault1. Excessive ambient temperature1. Improve cabinet cooling & reduce surrounding temp
2. Failed cooling fan2. Inspect/replace faulty fan
3. Poor cabinet ventilation3. Reserve ≥10cm clearance around drive
PF Power Supply Fault1. Abnormal input voltage (phase loss/low voltage)1. Measure three-phase incoming voltage & séquence de phases
2. Severe mains fluctuation2. Add line reactor or stabilizer
3. Loose input terminal wiring3. Retighten terminals at 2.5~3.0 N·m torque
SC Output Short-circuit1. Short on output terminals1. Check output terminal insulation
2. Damaged motor cable insulation2. Replace defective power cable
3. Internal drive hardware damage3. Contact Schneider after-sales service
FL Underload Alarm1. Disconnection between motor and mechanical load1. Check mechanical coupling between motor & charger
2. Insufficient load2. Adjust underload protection threshold (Parameter404)
3. Incorrect parameter setting3. Verify entered motor nameplate parameters
  1. Installation & Wiring Specification for Field Use

9.1 Exigences d'installation

  1. Position de montage: Middle/upper zone inside control cabinet, avoid dusty bottom area; vertical mounting only
  2. Autorisation: ≥10cm left/right spacing, ≥15cm top/bottom spacing for smooth heat dissipation
  3. Earthing Rule: Reliable PE connection; earth resistance ≤4Ω; ground conductor ≥6mm² copper cable

9.2 Main Power Circuit Wiring

Marquage des bornesDéfinitionWiring Standard
L1/L2/L33-phase AC Input≥6mm² copper cable, couple de serrage:2.5~3.0 N·m
U/V/WMotor Output Terminals≥6mm² copper cable, couple de serrage:2.5~3.0 N·m
PA/PBExternal Brake Resistor Connection(Facultatif)≥4mm² copper cable, couple de serrage:2.0~2.5 N·m
PEProtective Earth≥6mm² copper cable, couple de serrage:3.0~3.5 N·m

9.3 Câblage du circuit de commande

  1. Digital Input DI1~DI6: PNP/NPN switchable for limit switches & sensor signals
  2. Analog Input AI1: 0~10V /4~20mA for speed reference or process feedback signal
  3. Analog Output AO1:0~10V/4~20mA for output frequency, current or torque monitoring
  4. Communication: RS485 Modbus RTU for data exchange with PLC & IHM

Précédent:

Laisser une réponse

Laisser un message